Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION DENSITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Freeze-out temperature and density in heavy-ion collisions at liquid-gas phase transition

The study of properties of hot nuclei and the search for liquid-gas phase transition in nuclei have been the subjects of many investigations in recent decades. We present a short and limited review of the theoretical and experimental status of determining the temperature and density of the disassembling nucleus from ratios of the yields of emitted fragments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Visible core spectroscopy at Wendelstein 7-X

This paper presents an overview of recent hardware extensions and data analysis developments to the Wendelstein 7-X visible core spectroscopy systems. These include upgrades to prepare the in-vessel components for long-pulse operation, nine additional spectrometers, a new line of sight array for passive spectroscopy, and a coherence imaging charge exchange spectroscopy diagnostic. Progress in data analysis includes ion temperatures and densities from multiple impurity species, a statistical comparison with x-ray crystal spectrometer measurements, neutral density measurements from thermal passive Balmer-alpha emission, and a Bayesian analysis of active hydrogen emission, which is able to infer electron density and main ion temperature profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing charge neutralization for a magnetic sector SIMS instrument in negative mode

Successful self-adjusted charge compensation was demonstrated for a CAMECA magnetic-sector secondary ion mass spectrometer applied in negative mode. Operation with the normal-incidence electron gun (NEG) potential positively biased relative to a sample potential enables substantial broadening of the Cs primary-ion-current density range available for analysis of insulators. The decrease of the negative NEG potential by 30 V allows the highest value of primary current density used for the analysis of a silica sample to increase by a factor of more than 6. By applying the improved charge neutralization technique, accurate Na depth profiles for SiO{sub 2} samples were obtained within detection limits of {approx}3 Multiplication-Sign 10{sup 15} atoms/cm{sup 3}.

42 ENGINEERING↗

Ionosphere

Electron density and temperature, ion composition and density, and effects of solar corpuscular radiation in ionosphere - satellite drag measurements

ELECTRON TEMPERATURE↗

Spacecraft observations of the interaction of active comets with the solar wind

Six spacecraft encountered two comets during 1985 and 1986, obtaining a wealth of data relative to the plasma processes at work in the interaction of an active comet with the solar wind. A review of what space plasma scientists have learned from these data and of their interpretations is presented. The interaction process begins millions of kilometers from the nucleus where the solar wind first picks up cometary ions that slow down the wind and causes the interplanetary magnetic field to pile up and drape around the comet's ionosphere. Thus the geometry of a comet's plasma tail is defined by this draped field. At Halley the Giotto spacecraft noted a well-defined boundary separating the mixture of solar wind and cometary plasmas and the interplanetary magnetic field from the free-field, almost pure cometary plasma in the inner coma. Additional unexpected features in the inner coma were a flux of fast 'granddaughter' ions and high densities of negative ions. Further details covering pickup ions and plasma waves, mass loading, bow shock, energetic particles, the cometosheath, the ionopause, the plasma tail, and the field-free region are provided.

Neugebauer, M.↗

Ion-temperature- and density-gradient-driven instabilities and turbulence in Wendelstein 7-X close to the stability threshold

Electrostatic gyrokinetic instabilities and turbulence in the Wendelstein 7-X stellarator are studied. Particular attention is paid to the ion-temperature-gradient (ITG) instability and its character close to marginal stability [Floquet-type turbulence (Zocco et al., Phys. Rev. E, vol. 106, 2022, p. L013202) with no electron temperature gradient]. The flux tube version of the δƒ code stella (Barnes et al., J. Comput. Phys., vol. 391, 2019, pp. 365–380) is used to run linear and nonlinear gyrokinetic simulations with kinetic electrons. The nature of the dominant instability depends on the wavelength perpendicular to the magnetic field, and the results are conveniently displayed in stability diagrams that take this dependence into account. This approach highlights the presence of universal instabilities, which are less unstable but have longer wavelengths than other modes. A quasi-linear estimate of the heat flux suggests they are relevant for transport. Close to the stability threshold, the linear eigenmodes and turbulence form highly extended structures along the computational domain if the magnetic shear is small. Numerical experiments and diagnostics are undertaken to assess the resulting radial localisation of the turbulence, which affects the interaction of the latter with zonal flows. Increasing the amplitude of the magnetic shear (e.g.through current drive) has a stabilising effect on the turbulence and, thus, reduces the nonlinear energy transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation and diagnostics of pulsed intense ion beams with an energy density of 10 J/cm{sup 2}

The paper presents the results of a study on transportation and focusing of a pulsed ion beam at gigawatt power level, generated by a diode with explosive-emission cathode. The experiments were carried out with the TEMP-4M accelerator operating in double-pulse mode: the first pulse is of negative polarity (500 ns, 100-150 kV), and this is followed by a second pulse of positive polarity (120 ns, 200-250 kV). To reduce the beam divergence, we modified the construction of the diode. The width of the anode was increased compared to that of the cathode. We studied different configurations of planar and focusing strip diodes. It was found that the divergence of the ion beam formed by a planar strip diode, after construction modification, does not exceed 3° (half-angle). Modification to the construction of a focusing diode made it possible to reduce the beam divergence from 8° to 4°-5°, as well as to increase the energy density at the focus up to 10-12 J/cm{sup 2}, and decrease the shot to shot variation in the energy density from 10%-15% to 5%-6%. When measuring the ion beam energy density above the ablation threshold of the target material (3.5-4 J/cm{sup 2}), we used a metal mesh with 50% transparency to lower the energy density. The influence of the metal mesh on beam transport has been studied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coupling constant corrections in a holographic model of heavy ion collisions with nonzero baryon number density

Sufficiently energetic collisions of heavy ions result in the formation of a droplet of a strongly coupled liquid state of QCD matter known as quark-gluon plasma. By using gauge-gravity duality (holography), a model of a rapidly hydrodynamizing and thermal- izing process like this can be constructed by colliding sheets of energy density moving at the speed of light and tracking the subsequent evolution. In this work, we consider the dual gravitational description of such collisions in the most general bulk theory with a four-derivative gravitational action containing a dynamical metric and a gauge field in five dimensions. Introducing the bulk gauge field enables the analysis of collisions of sheets which carry nonzero “baryon” number density in addition to energy density. Introducing the four-derivative terms enables consideration of such collisions in a gauge theory with finite gauge coupling, working perturbatively in the inverse coupling. While the dynamics of energy and momentum in the presence of perturbative inverse-coupling corrections has been analyzed previously, here we are able to determine the effect of such finite coupling corrections on the dynamics of the density of a conserved global charge, which we take as a model for the dynamics of nonzero baryon number density. In accordance with expectations, as the coupling is reduced we observe that after the collisions less baryon density ends up stopped at mid-rapidity and more of it ends up moving near the lightcone.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of plasma density fluctuations by a heavy ion beam probe diagnostic with multiple cell array detector on the tokamak ISTTOK

The heavy ion beam probe (HIBP) diagnostic permits the measurements of electron density and plasma potential as well as their fluctuations. The use of a multiple cell array detector (MCAD) spreads the HIBP capabilities to make simultaneous measurements across the plasma column. Two sets of current-to-voltage converters with respective bandwidths of 400 kHz and 4 MHz have been tested. This upgrade of the MCAD electronics has allowed the observation of quasicoherent fluctuations in bulk plasma at frequencies between 100 and 200 kHz. The localization and frequency of bulk plasma fluctuations correlate with the magnetohydranamic activity of the plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of microwave driver coupling design on plasma density at Testbench for Ion sources Plasma Studies, a 2.45 GHz Electron Cyclotron Resonance Plasma Reactor

A comparative study of two microwave driver systems (preliminary and optimized) for a 2.45 GHz hydrogen Electron Cyclotron Resonance plasma generator has been conducted. The influence on plasma behavior and parameters of stationary electric field distribution in vacuum, i.e., just before breakdown, along all the microwave excitation system is analyzed. 3D simulations of resonant stationary electric field distributions, 2D simulations of external magnetic field mapping, experimental measurements of incoming and reflected power, and electron temperature and density along the plasma chamber axis have been carried out. By using these tools, an optimized set of plasma chamber and microwave coupler has been designed paying special attention to the optimization of stationary electric field value in the center of the plasma chamber. This system shows a strong stability on plasma behavior allowing a wider range of operational parameters and even sustaining low density plasma formation without external magnetic field. In addition, the optimized system shows the capability to produce values of plasma density four times higher than the preliminary as a consequence of a deeper penetration of the magnetic resonance surface in relative high electric field zone by keeping plasma stability. The increment of the amount of resonance surface embedded in the plasma under high electric field is suggested as a key factor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Global model analysis of negative ion generation in low-pressure inductively coupled hydrogen plasmas with bi-Maxwellian electron energy distributions

A global model was developed to investigate the densities of negative ions and the other species in a low-pressure inductively coupled hydrogen plasma with a bi-Maxwellian electron energy distribution. Compared to a Maxwellian plasma, bi-Maxwellian plasmas have higher populations of low-energy electrons and highly vibrationally excited hydrogen molecules that are generated efficiently by high-energy electrons. This leads to a higher reaction rate of the dissociative electron attachment responsible for negative ion production. The model indicated that the bi-Maxwellian electron energy distribution at low pressures is favorable for the creation of negative ions. In addition, the electron temperature, electron density, and negative ion density calculated using the model were compared with the experimental data. In the low-pressure regime, the model results of the bi-Maxwellian electron energy distributions agreed well quantitatively with the experimental measurements, unlike those of the assumed Maxwellian electron energy distributions that had discrepancies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Meteoric Magnesium Ions in the Martian Atmosphere

From a thorough modeling of the altitude profile of meteoritic ionization in the Martian atmosphere we deduce that a persistent layer of magnesium ions should exist around an altitude of 70 km. Based on current estimates of the meteoroid mass flux density, a peak ion density of about 10(exp 4) ions/cm is predicted. Allowing for the uncertainties in all of the model parameters, this value is probably within an order of magnitude of the correct density. Of these parameters, the peak density is most sensitive to the meteoroid mass flux density which directly determines the ablated line density into a source function for Mg. Unlike the terrestrial case, where the metallic ion production is dominated by charge-exchange of the deposited neutral Mg with the ambient ions, Mg+ in the Martian atmosphere is produced predominantly by photoionization. The low ultraviolet absorption of the Martian atmosphere makes Mars an excellent laboratory in which to study meteoric ablation. Resonance lines not seen in the spectra of terrestrial meteors may be visible to a surface observatory in the Martian highlands.

Pesnell, William Dean↗

Negative ions in the ionospheres of planetary bodies without atmospheres

It is noted that negative ions may be formed in the ionospheres of Mercury, the moon, and Jupiter's satellites with densities of a few percent of the ionospheric electron density. Negative ions result from three mechanisms at the planetary surface: charge inversion during energetic proton scattering, with simultaneous secondary negative ion emission, and micrometeorite impacts. The density and distribution of negative ions around planetary bodies depends primarily on the negative ion lifetimes determined through photodetachment by solar radiation.

Wekhof, A.↗

On Ba(+) production in the CRIT 2 experiment

Analysis of partical data from the CRIT 2 experiment, studying Alfven's critical ionization velocity (CIV) effect, shows that the density of newly created ions (presumably Ba(+) from the shaped-charge beam) is consistent with the increase in total plasma density measured by the independent RF plasma probe on board (Swenson et al., 1990) at the most active time period. We model this ion production using the measured electron flux data and the neutral barium model of Stenbaek-Nielsen et al. (1990a). To identify the main source mechanisms which may contribute most to the barium ionization, a simple model for the barium ion density at the payload location is developed based on Liouvilles theorem. We estimate that the electron impact ionization is responsible for 90% of the barium ion production observed by CRIT 2 in the first release and up to 45% in the second release. By employing a two-state approximation calculation (Rapp and Francis, 1962), the Ba-O(+) charge exchange cross section is found to range from about 2.0 X 10(exp -17) sq cm at a velocity of 4 km/s to 2.0 X 10(exp -15) sq cm at a velocity of 20 km/s. This result suggests that the Ba-O(+) charge exchange is probably dominant among all the non-CIV ionization processes. By considering the charge exchange process in our density model, the barrium ion densities are calculated for the two releases on CRIT II. The comparison between the model results and the observed data is found to be resonably consistent if the cross sections, as calculated above, are multiplied by 0.3 for the first release and 1.0 for the second release. Our result suggests that the charge exchange process could be the most important non-CIV ionization mechanism in the CRIT II experiment and it should be considered carefully case by case in CIV experiments.

Liou, K.↗

Thirty-centimeter-diameter ion milling source

A 30-cm beam diameter ion source has been designed and fabricated for micromachining and sputtering applications. An argon ion current density of 1 mA/cu cm at 500 eV ion energy was selected as a design operating condition. The completed ion source met the design criteria at this operating condition with a uniform and well-collimated beam having an average variation in current density of + or - 5% over the center of 20 cm of the beam. This ion source has a multipole magnetic field that employs permanent magnets between permeable pole pieces. Langmuir probe surveys of the source plasma support the design concepts of a multipole field and a circumferential cathode to enhance plasma uniformity.

Robinson, R. S.↗