Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERCONNECTIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Experimental Validation of a 40kW, 480V Point-to-Point DC Interlinks for Controller-Agnostic, Interoperable Networked Microgrids

This paper presents the experimental validation of point-to-point dc-interlinks for interconnecting two solar-based, laboratory-scale AC microgrids. DC interlinks provide a solution to numerous technical and operational challenges encountered in networked microgrids, including precise power flow control, stable and fast synchronization, enhanced stability, and improved voltage and frequency regulation. By decoupling microgrids through power converters, dc-interlinks enable power exchange among microgrids that can be owned by different entities (such as communities, utilities, or universities) and managed by diverse microgrid controller vendors. This characteristic makes this dc-interlinks a promising solution for networking real-world microgrids. The presented point-to-point dc interlink utilizes two four-quadrant converters: a 40kW 3-phase ac/dc regulating the dc-link voltage to 800V, and a 3-phase dc/ac controlling power flow. These converters, connected via a 20-foot dc cable, interconnect two ac microgrids operating at 480V, each featuring energy storage, photovoltaic generation, and load emulation. Experimental validation employs commercially available off-the-shelf (COTS) converters and real-world data from solar-powered microgrids in Adjuntas, Puerto Rico. To the authors’ knowledge, this work provides the first at-scale experimental validation of dc-interlinks for networked ac microgrids using COTS inverters, demonstrating their practicality and effectiveness in addressing real-world operational challenges.

Ferrari Maglia, Max [ORNL]↗

Graph Laplacian Spectrum and Primary Frequency Regulation: Preprint

We present a framework based on spectral graph theory that captures the interplay among network topology, system inertia, and generator and load damping in determining overall power grid behavior and performance. Specifically, we show that the impact of network topology on a power system can be quantified through the network Laplacian eigenvalues, and such eigenvalues determine the grid robustness against low frequency disturbances. Moreover, we can explicitly decompose the frequency signal along scaled Laplacian eigenvectors when damping-intertia ratios are uniform across buses. The insight revealed by this framework suggests why load-side participation in frequency regulation not only makes the system respond faster, but also helps lower the system nadir after disturbance. Finally, by presenting a new controller specifically tailored to suppress high frequency disturbances, we demonstrate that our results can provide useful guidelines in the controller design for load-side primary frequency regulation. We simulate the improved controller on the IEEE 39-bus New England interconnection system to illustrate its robustness against high frequency oscillation compared to both the conventional droop control and a recent controller design.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Factorization Machine Learning for Disaggregation of Transmission Load Profiles with High Penetration of Behind-the-Meter Solar

The ever-growing high penetration of ubiquitously distributed energy resources, especially behind-the-meter solar (BTM) generations, has significant impacts on nodal load (i.e., net injection) profiles and consequently caused imperative operational challenges to system operators such as regional transmission organizations (RTOs). Illustrated by real-world nodal data and examples at PJM Interconnection, this paper first discusses the application and necessity of effectively extracting daily nodal load profiles in a non-intrusive manner. More importantly, a novel bi-level architecture, including Factorization Machines (FM) learning procedure has been proposed to effectively disaggregate not only one node but every node in an RTO service territory. Specifically, FM leaning is adopted to capture the interconnections between related features to better utilize the correlation between buses in the same region and between a single bus and the zonal load. The proposed bi-level technique is numerically validated using real-world, minute-level, normalized, and anonymized nodal data at PJM service territory.

behind the meter solar, load disaggregation, load ↗

Effects of Encapsulant Properties on the Thermo-Mechanical Reliability of Double-Side Cooled Power Modules for Traction Inverters

Double-side cooled power modules are being developed for next-generation traction inverters due to their better heat extraction, lower profile, and lower parasitic inductances. However, due to their rigid structure, they cause reliability concerns arising from high thermo-mechanical stresses at the interconnection joints in the module. In this work, a materials-based approach using rigid encapsulants is presented for reducing thermo-mechanical fatigue. Finite-element thermo- mechanical simulations were performed to examine the effects of the elastic modulus and coefficient of thermal expansion of epoxy- based encapsulants on the bond deformation inside a double-side cooled power module. It was found that a rigid encapsulant with a high modulus of 6.0 GPa or above and a coefficient of thermal expansion around 20 ppm/oC would improve the thermo- mechanical reliability of double-side cooled power modules by decreasing the permanent bond deformation inside the modules by 50-60%.

ADVANCED PROPULSION SYSTEMS↗

Partitioning of Large-Scale Power Electronics-Based Power Systems for Small-Signal Stability Analysis

The nodal admittance matrix (NAM)-based approach is suitable for analyzing the small-signal stability of large-scale power electronics-based power systems (PEPSs) as it preserves the system structure by utilizing the admittance matrix. Previously, NAM-based area partition has been proposed, which divides the system into various subareas and interconnections for easier analysis of the low-dimension matrix compared to the entire system-based high-dimension matrix. However, no partition algorithm has been presented for the NAM-based area partition method. This paper focuses on implementing the spectral partitioning algorithm for partitioning large-scale PEPSs into a low-dimension matrix to reduce the computation complexity of the analysis. These spectral components facilitate data transformation into a new space, enabling the application of traditional clustering methods like k-means. To evaluate the performance of the partitioning method, the subareas and interconnections obtained from the spectral clustering algorithm are incorporated into the NAM-based area partition method for a large system with 140 buses. The computational times of the original method, where the NAM-based criterion is directly applied to the entire system, are compared with those of the NAM-based partition method in MATLAB. PSCAD simulations of the whole system and the obtained subareas are conducted to validate the effectiveness of the proposed algorithm.

Nupur, Nupur↗

Packaging of an 8-kV Silicon Carbide Diode Module with Double-Side Cooling and Sintered-Silver Joints

Packaging innovations are needed for medium-voltage wide bandgap power semiconductor modules to enable their adaptation in grid applications. A unique challenge for packaging medium-voltage power modules is managing the trade-off between insulation demand and heat dissipation. The focus of this work was on developing a packaging innovation that improves the module heat dissipation and offers more flexibility to its insulation design. Two strategies were explored for the packaging of an 8-kV SiC diode rectifier module:(1) double-side cooling and (2) sintered-silver bonding. Double-side cooling was realized by using short metal posts rather than long and thin wire bonds for device interconnection, forming a low-profile package with devices sandwiched between two insulated metal substrates. Sintered-silver bonding enabled the devices to function reliably at over 250 °C. Simulations of the packaged module showed a low interconnect inductance of 2.67 nH and a 50% less heat transfer coefficient required to cool the chips. Prototypes of the module were fabricated, and preliminary electrical testing results validated the package design.

27 ARPA - Advanced Research Projects Agency-Energy↗

Energy Storage for Frequency Control in High Photovoltaic Power Grids

Frequency stability of power systems becomes more vulnerable with the increase of solar photovoltaic (PV). Energy storage provides an option to mitigate high PV impact. Using the United States Eastern Interconnection (EI) and Texas Interconnection (ERCOT) power grid models, this paper investigates the capabilities of using energy storage to improve frequency stability of high PV power grids. The study result helps to identify the potential and impact factors in utilizing energy storage to regulate frequency in high renewable power grids.

14 SOLAR ENERGY↗

A Novel Resilience-Oriented Cellular Grid Formation Approach for Distribution Systems with Behind-the-Meter Distributed Energy Resources

This paper presents a resilience-oriented cellular grid formation approach to achieve scalable and reconfigurable community microgrid operations for distribution systems with behind-the-meter distributed energy resources. A set of interconnected solar photovoltaics, energy storage systems, and load is termed as a cell, implying a subset of the grid that can operate independently using its own resources. Cells are identified such that each cell inherently has sufficient energy resources to black start and can provide a certain level of backup power for its load under the loss of utility power supply. The proposed cell formation approach builds on a unique self-organizing map-based method (SomRes) to quantify a system's resilience. Using SomRes and a non-dominated sorting-based genetic algorithm (NSGA-II), a fast and efficient cell formation algorithm is developed to identify cells in a distribution system that are resilient against extreme events. The efficacy of the proposed approach is demonstrated on a numerical model of a real distribution feeder in Colorado, United States.

distributed energy resource↗

Effective Tooling for Linked Data Publishing in Scientific Research

Challenges that make it difficult to find, share, and combine published data, such as data heterogeneity and resource discovery, have led to increased adoption of semantic data standards and data publishing technologies. To make data more accessible, interconnected and discoverable, some domains are being encouraged to publish their data as Linked Data. Consequently, this trend greatly increases the amount of data that semantic web tools are required to process, store, and interconnect. In attempting to process and manipulate large data sets, tools–ranging from simple text editors to modern triplestores– eventually breakdown upon reaching undefined thresholds. This paper offers a systematic approach that data publishers can use to categorize suitable tools to meet their data publishing needs. We present a real-world use case, the Resource Discovery for Extreme Scale Collaboration (RDESC), which features a scientific dataset(maximum size of 1.4 billion triples) used to evaluate a toolbox for data publishing in climate research. This paper also introduces a semantic data publishing software suite developed for the RDESC project.

Purohit, Sumit↗

Fault Contribution of Grid-Following and Grid-Forming Inverters Considering Generic Inverter Controls and Ride-through Requirements

Gradual transformation of the synchronous generator (SG)-dominated power systems to inverter-based resource (IBR)-dominated power systems is bringing new challenges regarding power system protection. Increasing IBR’s penetration will reduce the reliability of protection coordination, originally developed for SG-dominated power systems, potentially leading to less accurate calculation or even mis-operation. Thus, new protection schemes compatible with IBR-dominated power systems should be established. Prior to establishing the protection schemes, research on the fault contribution of generic IBR models should be conducted considering interconnection requirements. This paper conducts fault current contribution analysis of generic grid-following (GFL) and grid-forming (GFM) inverters considering interconnection requirements using an electromagnetic transient (EMT) simulation tool. To do this, EMT-based generic GFL models have been developed with the ride-through requirements from IEEE-1547 standards. In addition, the major functions of the generic models are explained. Then, the fault current analysis was conducted using GFL and GFM inverters in a single-inverter-infinite-bus system and a modified IEEE 34-node system considering different grid, fault, inverter control parameters.

Kim, Jinho [BATTELLE (PACIFIC NW LAB)]↗

Model-less Source Location for Forced Oscillation based on Synchrophasor and Moving Fast Fourier Transformation

Forced oscillations in power systems occur when the grid is driven by an external and periodic force. To quickly detect and locate the source of the forced oscillation is critical in terms of ensuring the reliability of an interconnected power grid. This paper explores the electromechanical wave propagation theory and the Fast Fourier Transformation to analyze the forced oscillations. It proposes a model-less, adaptive, fast, and accurate source location algorithm. The proposed algorithm is extensively evaluated through simulation data from a 70k-bus U.S. Eastern Interconnection test system and field-collected synchrophasor data from the distribution-level wide-area monitoring system, FNET/GridEye. The evaluation results demonstrate the correctness and effectiveness of the proposed model-less forced oscillation source location algorithm.

Wang, Weikang↗

Experimental Evaluation of Grid Support Enabled PV Inverter Response to Abnormal Grid Conditions

As revised interconnection standards for grid-tied photovoltaic (PV) inverters address new advanced grid support functions (GSFs), there is increasing interest in inverter performance in the case of abnormal grid conditions. The growth of GSF-enabled inverters has outpaced the industry standards that define their operation, although recently published updates to UL1741 Supplement SA define test conditions for GSFs such as volt-var control, frequency-watt control, and voltage/frequency ride-through, among others. This paper describes the results of a comparative experimental evaluation on four commercially available, three-phase PV inverters in the 24.0-39.8 kVA power range on their GSF capability and its effect on abnormal grid condition response. The evaluation examined the impact particular GSF implementations have on run-on times during islanding conditions, peak voltages in load rejection overvoltage scenarios, and peak currents during single-phase and three-phase fault events for individual inverters. Testing results indicated a wide variance in the performance of GSF enabled inverters to various test cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Estimation, Minimization, and Validation of Commutation Loop Inductance for a 135-kW SiC EV Traction Inverter

With growing interests in low inductance SiC based power module packaging, it is vital to focus on system level design aspects to facilitate easy integration of the modules and reap system level benefits. To effectively utilize the low inductance modules, busbar and interconnects should also be designed with low stray inductances. A wholistic investigation of the flux path and flux cancellations in the module-busbar assembly which as differentially coupled series inductors is thus mandatory for a system level design. This work presents a busbar design which can be adopted to effectively integrate the CREE’s low inductance 1.2 kV/1.7 kV SiC power modules. The paper also proposes a novel measurement technique to measure the inductance of the modulebusbar assembly as a whole rather than deducing it from individual components. The inductance of the overall commutation loop of the inverter which encompasses the SiC power module, interconnects and PCB busbar have been estimated using finite element analysis (FEA). Furthermore, insights gained from FEA provided the guidelines to decide on the placement of the decoupling capacitors in the busbar to minimize the overall commutation loop inductance from 12.8 nH to 7.4 nH which resulted in significant reduction in the device voltage overshoot. The simulation results have been validated through measurements using an impedance analyzer with less than 5% difference between extracted loop inductance from FEA and measurements. The bus bar design study and the measurement technique discussed in this paper, can be easily extended to other power module packages. Finally, the 135 kW inverter has been compared to a similar highpower inverter utilizing a laminated busbar to highlight the performance of the former.

42 ENGINEERING↗

Tunnel Junction Development Using Hydride Vapor Phase Epitaxy

We demonstrate for the first time III-V tunnel junctions grown using hydride vapor phase epitaxy (HVPE) with peak tunneling currents >8 A/cm 2 , sufficient for operation of a multijunction device to several hundred suns of concentration. Multijunction solar cells rely on tunneling interconnects between subcells to enable series connection with minimal voltage loss, but tunnel junctions have never been shown using the HVPE growth method. HVPE has recently reemerged as a low-cost growth method for high-quality III-V materials and devices, including the growth of high-efficiency III-V solar cells. We previously showed single-junction GaAs solar cells with conversion efficiencies of ~24% with a path forward to equal or exceed the practical efficiency limits of crystalline Si. Moving to a multijunction device structure will allow for even higher efficiencies with minimal impact on cost, necessitating the development of tunnel interconnects. Here in this paper, we demonstrate the performance of both isolated HVPE-grown tunnel junctions, as well as single-junction GaAs solar cell structures with a tunnel junction incorporated into the contact region. We observe no degradation in device performance compared to a structure without the added junction.

14 SOLAR ENERGY↗

A Practical Approach to Inertia Assessment: Analyzing New York's Grid Response to Real Events

The non-uniform distribution of inverter-based resources (IBRs) such as solar and wind energy leads to the formation of weakly coupled regions within the broader interconnection. This highlights the urgency of investigating regional dynamics. This paper proposes a practical framework for estimating regional inertia using actual event measurements from the New York (NY) region. The regional frequency is determined using measurement data from frequency disturbance recorders (FDRs) deployed across NY. The rate-of-change of frequency (RoCoF) is estimated using a hybrid methodology that combines the benefits of both moving and non-moving window techniques. By utilizing the power mismatch value and the estimated RoCoF, various inertia metrics such as regional RoCoF, inertia arrival time, and inertia percentage relative to the interconnection inertia are calculated. The identified confirmed-events that took place between 2017–2022 in NY are used in the study. This assessment of inertia using real event data reveals the true behavior of the grid under stress. The results indicate that as the generation mix in NY evolves with the rise of IBRs, both the RoCoF levels and the regional inertia undergo significant changes.

Dulal, Saurav [University of Tennessee, Knoxville ↗

Regional Inertia Estimation Using Actual Event Measurements: Florida Case

As inverter-based resources’ integration in power grids increases, their uneven distribution across the electrical network leads to the formation of local regions that are weakly coupled to the larger interconnection. This signifies the necessity of regional frequency dynamics investigation and analyzing various inertia metrics. This paper presents a practical methodology for estimating regional rate-of-change of frequency (RoCoF) using actual event recordings, which is then used to evaluate regional inertia. Florida (FL) is selected as the region of interest due to its distinct regional frequency dynamics and the rising levels of solar generation. We identify and analyze confirmed events from 2017 to 2024 that occurred in FL. The results indicate that FL contributes about 14% to the total inertia of the US Eastern Interconnection, which approximately matches its share of generation capacity. Results also highlight seasonal fluctuations in energy generation, which play a significant role in influencing inertia and thus the RoCoF levels. This emphasizes the importance of estimating regional inertia to enhance grid operations for a future that focuses on distributed generation.

Dulal, Saurav [University of Tennessee, Knoxville ↗

Spectral Clustering-Based Partitioning of Large-Scale Power Electronics-Based Power Systems for Small-Signal Stability Analysis

The nodal admittance matrix (NAM)-based approach is well-suited for small-signal stability analysis of large-scale power electronics-based power systems (PEPSs), as it preserves the system structure through its admittance matrix. Previous studies have explored partitioning such systems into subareas and interconnections to reduce computational burden; however, they lacked a formal algorithmic procedure for determining feasible partitions. While several grid partitioning methods, such as those based on graph theory or machine learning, exist in the literature, they cannot be directly applied to NAM-based analysis due to differing objectives and constraints. Here, this paper addresses this gap by presenting a systematic, step-by-step procedure for applying a spectral partitioning algorithm that yields a division of the system into subareas suitable for NAM-based analysis. The computational complexity of the proposed method is also derived to demonstrate its efficiency and justify the practicality of the resulting subarea decomposition. The performance of the partitioning method is evaluated by applying the spectral clustering-derived subareas and interconnections to the NAM-based partitioning approach on a 140-bus system. Computational times for the full-system and partitioned NAM analyses are compared using MATLAB. Additionally, PSCAD simulations of the complete system and partitioned subareas are carried out to verify the effectiveness of the proposed method.

Nupur [Univ. of Tennessee, Knoxville, TN (United S↗

Impedance-Based Prediction of SSR-Generated Harmonics in Doubly-Fed Induction Generators

Doubly-fed induction generators (DFIGs) are prone to subsynchronous resonance (SSR) with series-compensated transmission lines and experiencing SSR-generated harmonics of wide-ranging magnitudes. This paper presents a large-signal impedance-based approach for the prediction of the magnitude of SSR-generated harmonics in DFIGs. Note that the large-signal impedance of a network shows variation in its impedance response with the magnitude of perturbation at its terminals. It is discovered in this paper that the impedance of a series-compen- sated transmission line starts changing with the magnitude of SSR because of the metal-oxide varistor-based protection of series capacitors in the line. The changing line impedance halts the growth of the SSR beyond a certain point, where the DFIG forms a limit-cycle mode and emits harmonics at the SSR frequency. The discovered role of the protection of series capacitors in SSR not only enables the prediction of SSR-generated harmonics but also can be used for the timely detection of an SSR event to avoid system disruption and sudden loss of bulk generation. The large- signal impedance-based prediction of SSR-generated harmonics in DFIG-based wind and hydro generators is demonstrated using numerical simulations of a 2.5-MVA, 690-V DFIG supplying to a series-compensated transmission line.

24 POWER TRANSMISSION AND DISTRIBUTION↗