Cryogenic line insulation made from prefabricated polyurethane shells

Prefabricated polyurethane foam insulation is inexpensive and easily installed on cryogenic lines. Insulation sections are semicircular half shells. Pair of half shells is placed to surround cryogenic line. Cylindrically-shaped knit sock is pulled over insulation then covered with polyurethane resin to seal system.

Lerma, G.↗

PPO foam - Liquid hydrogen insulation

An extensive fabrication and test program is described which has demonstrated the integrity of PPO (polyphenylene oxide) foam as an internal insulation. PPO is shown to be capable of withstanding multiple reuses on such cryogenic-fueled launch vehicles as the Space Shuttle. The major advantages of this internal insulation is the absence of a pressure load on the insulation, reduced handling damage, and minimization of cyclic thermal stresses by a 'warm' bond line.

Yates, G. B.↗

Evaluation of low cost/high temperature insulation, July 1974 - June 1975

Six fiber products and six insulation blankets comprising silica, alumina, zirconia, mullite, and mixed ceramic systems were subjected to furnace exposures up to 500 hours at temperatures of 1000 to 1600 C and evaluated for chemical and dimensional stability and for changes in thermal conductivity. Alumina, zirconia, and mullite fibers were fabricated into reusable surface insulation (RSI) tile by water-felting and reimpregnation with ethyl silicate. Specimens were exposed to 25 thermal cycles at 1200 C and 1400 C and a pressure of 10 and 32 torr, respectively. Production costs for 930 sq m (10,000 sq ft) of blanket insulation and of alumina RSI tile were developed.

Strauss, E. L.↗

Current from a dilute plasma measured through holes in insulators

The current collected from a plasma through holes in insulated electrodes was measured. Holes of 0.051- and 2.54-cm diameters in Kapton H film and plasma number densities of 100 and 10,000 electrons/cu cm were used. The current collected by bare electrodes, that is, electrodes with no surrounding insulation, is also presented. For all the samples the current at a given voltage was a function of the surrounding insulator area rather than of the hole size or the underlying electrode size. In addition, at the low plasma density the I-V characteristic showed very steep rises for voltages below 1 kV. In one case the current jumped by a factor of approximately 70 to 200 V. Results are given for positive biases to 10 kV. For negative biases, sparking prevented testing most samples to the 10-kV limit.

Grier, N. T.↗

Modal analysis and dynamic stresses for acoustically excited shuttle insulation tiles

Improvements and extensions to the RESIST computer program developed for determining the normalized modal stress response of shuttle insulation tiles are described. The new version of RESIST can accommodate primary structure panels with closed-cell stringers, in addition to the capability for treating open-cell stringers. In addition, the present version of RESIST numerically solves vibration problems several times faster than its predecessor. A new digital computer program, titled ARREST (Acoustic Response of Reusable Shuttle Tiles) is also described. Starting with modal information contained on output tapes from RESIST computer runs, ARREST determines RMS stresses, deflections and accelerations of shuttle panels with reusable surface insulation tiles. Both programs are applicable to stringer stiffened structural panels with or without reusable surface insulation titles.

Ojalvo, I. U.↗

Theoretical transducer properties of piezoelectric insulator FET transducers

An oriented piezoelectric film incorporated in the insulator region of a silicon insulated-gate field-effect transistor (FET) results in a sensitive high-frequency strain transducer. Theory governing the transducer properties of the piezoelectric insulator FET transducer is presented. Equations are developed which relate the drain current of the device to induced polarizations of the piezoelectric layer. The highest frequency of surface strains to which the FET transducer can respond is determined by the FET frequency response - ultimately by the channel transit time. This frequency can extend to the GHz range. The low-frequency response to applied strain is determined by the dielectric relaxation frequency of the piezoelectric layer.

Greeneich, E. W.↗

Metal-thin film insulator-semiconductor solar cells

The characteristics of a specific M-I-S structure are analyzed for various assumed roles of the thin-film insulating layer. It is shown that the behavior of an ideal Schottky barrier is obtained in the case where the insulating layer does not hinder transport and no localized states are present (or, if present, their population is dictated by the metal Fermi level). The cell is a majority carrier device; by using the insulating layer to control transport, it becomes a minority carrier cell.

Fonash, S. J.↗

Thermal performance of a modularized replaceable multilayer insulation system for a cryogenic stage

A rugged modularized MLI system for a 2.23-meter-diameter (87.6-in.-diam) liquid hydrogen tank was designed, fabricated, and tested under simulated near-earth and deep-space environments. The two blankets of the system were each composed of 17 double-aluminized Mylar radiation shields separated by silk net. The unit area weight of the installed system was 1.54 kg/sqm (0.32 lb/sq ft). The overall average heat transferred into the insulated tank was 22.7 and 0.98 watts (77.4 and 3.3 Btu/hr) during simulated near-earth and deep-space testing, respectively. The near-earth result was only 2.6 times that predicted for an undisturbed insulation system (i.e., no seams or penetrations). Tests indicate that this insulation concept could be useful for a cryogenic space tug or orbit transfer vehicle application.

Knoll, R. H.↗

Solid rocket motor internal insulation

Internal insulation in a solid rocket motor is defined as a layer of heat barrier material placed between the internal surface of the case propellant. The primary purpose is to prevent the case from reaching temperatures that endanger its structural integrity. Secondary functions of the insulation are listed and guidelines for avoiding critical problems in the development of internal insulation for rocket motors are presented.

Twichell, S. E.↗

Insulation end life determination for completed form-wound generators

Tests were conducted to predict remaining electrical insulation life of a polyimide-epoxy insulated 60 kW form-wound homopolar inductor generator following completion of 23,130 hours of turbo-generator endurance tests. The generator stator was sectioned to provide five sections, designated statorettes, and to permit 33 coil dielectric measurements on each section. Thermal aging tests were conducted on each section at select elevated temperatures to establish an Arrhenius life-temperature plot for end-life prediction and product or application use. The statorette fabrication technique is considered novel and provides means to establish insulation life-temperature profiles on completed electromagnetic components of rotating machines.

Penn, W. B.↗

Rain erosion considerations for launch vehicle insulation systems

In recent years the Delta launch vehicle has incorporated the capability to be launched through rain. This capability was developed to eliminate a design constraint which could result in a costly launch delay. This paper presents the methodology developed to implement rain erosion protection for the insulated exterior vehicle surfaces. The effect of the interaction between insulation material rain erosion resistance, rainstorm models, surface geometry and trajectory variations is examined. It is concluded that rain erosion can significantly impact the performance of launch vehicle insulation systems and should be considered in their design.

Daniels, D. J.↗

Evacuated load-bearing high performance insulation study

A light weight, vacuum jacketed, load bearing cryogenic insulation system was developed and tested on a 1.17-m (46-in.) spherical test tank. The vacuum jacket consists of 0.08 mm (0.003 in.) thick 321 stainless steel formed into a wedge design that allows elastic jacket movements as the tank shrinks (cools) or expands (warms up or is pressurized). Hollow glass spheres, approximately 80 micrometers in diameter with a bulk density of 0.069 g/cc (4.3 lb cubic foot), provide the insulating qualities and one atmosphere load bearing capability required. The design, fabrication, and test effort developed the manufacturing methods and engineering data needed to scale the system to other tank sizes, shapes, and applications. The program demonstrated that thin wall jackets can be formed and welded to maintain the required vacuum level of .013 Pa yet flex elastically for multiple reuses. No significant shifting or breakage of the microspheres occurred after 13 simulated Space Tug flight cycles on the test tank and a hundred 1 atmosphere load cycles in a flat plate calorimeter. The test data were then scaled to the Space Tug LO2 and LH2 tanks, and weight, thermal performance, payload performance, and costs were compared with a helium purged multilayer insulation system.

Parmley, R. T.↗

Thermal Performance of a Customized Multilayer Insulation (MLI). Design and Fabrication of Test Facility Hardware

The design, fabrication, and assembly of hardware for testing the performance of a customized multilayer insulation are discussed. System components described include the thermal payload simulator, the modified cryoshroud, and a tank back pressure control device designed to maintain a constant liquid boiling point during the thermal evaluation of the multilayer insulation. The thermal payload simulator will provide a constant temperature surface in the range of 20.5 to 417K (37 to 750R) for the insulated tank to view. The cryoshroud was modified to establish a low temperature black body cavity while limiting liquid hydrogen usage to a minimum feasible rate.

Leonhard, K. E.↗

Thermal performance of gaseous-helium-purged tank-mounted multilayer insulation system during ground-hold and space-hold thermal cycling and exposure to water vapor

An experimental investigation was conducted to determine (1) the ground-hold and space-hold thermal performance of a multilayer insulation (MLI) system mounted on a spherical, liquid-hydrogen propellant tank and (2) the degradation to the space-hold thermal performance of the insulation system that resulted from both thermal cycling and exposure to moisture. The propellant tank had a diameter of 1.39 meters (4.57ft). The MLI consisted of two blankets of insulation; each blanket contained 15 double-aluminized Mylar radiation shields separated by double silk net spacers. Nineteen tests simulating basic cryogenic spacecraft thermal (environmental) conditions were conducted. These tests typically included initial helium purge, liquid-hydrogen fill and ground-hold, ascent, space-hold, and repressurization. No significant degradation of the space-hold thermal performance due to thermal cycling was noted.

Sumner, I. E.↗

Ignitability of some insulation and building materials

A variety of insulation and building materials were evaluated for ignitability, using a screening test method developed at the University of San Francisco. Ignitability tended to be greater with the more efficient insulation materials because the insulating qualities resulted in a more rapid rise in temperature at the exposed surface. The use of a noncombustible facing material is recommended to provide protection from surface ignition.

Hilado, C. J.↗

Environmental effects on space shuttle reusable surface insulation coated with reaction cured glass

Sample titles of the space shuttle reusable surface insulation was subjected alternately to simulated mission heating and either real or simulated environmental exposure for up to 34 cycles. The coating cracked as a result of exposure to high temperature and moisture conditions, and insulation with cracked coatings absorbed significant quantities of water in the launch-pad environment. Cracking was a complex function of time, temperature, and moisture exposure. Cracked coatings remained adherent to the insulation for up to 24 cycles past initial cracking.

Ransone, P. O.↗

Effects of carbon/graphite fiber contamination on high voltage electrical insulation

The contamination mechanics and resulting failure modes of high voltage electrical insulation due to carbon/graphite fibers were examined. The high voltage insulation vulnerability to carbon/graphite fiber induced failure was evaluated using a contamination system which consisted of a fiber chopper, dispersal chamber, a contamination chamber, and air ducts and suction blower. Tests were conducted to evaluate the effects of fiber length, weathering, and wetness on the insulator's resistance to carbon/graphite fibers. The ability of nuclear, fossil, and hydro power generating stations to maintain normal power generation when the surrounding environment is contaminated by an accidental carbon fiber release was investigated. The vulnerability assessment included only the power plant generating equipment and its associated controls, instrumentation, and auxiliary and support systems.

Garrity, T.↗

Description of the manufacturing challenges in producing the high-temperature reusable surface insulation for the thermal protection system of the Space Shuttle

The paper describes the high-temperature reusable surface insulation for the thermal protection system of the Space Shuttle. This system protects the Space Shuttle Orbiter on reentry and it is an externally attached, rigidized, fibrous silica, machined into 15 x 20 cm tiles. The tiles constitute the High-Temperature Reusable Surface Insulation (HRSI) system, and are used on over 70 percent of the exterior surface where peak temperatures range from 400 to 1260 C. Carbon-carbon leading edges are used in areas where peak temperatures exceed 1650 C, and a Nomex felt flexible insulation system is used in regions below 400 C. Approximately 32,000 tiles are used in the HRSI system, and due to vehicle configuration and aerodynamic requirements no two tiles are alike.

Forsberg, K.↗