Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Dispersion and absorption of longitudinal electro-kinetic wave in ion-implanted GaN semiconductor plasmas

An analytical study on propagation characteristics of longitudinal electro-kinetic (LEK) waves is presented. Based on multi-fluid model of plasma, we have derived a dispersion relation for LEK waves in colloid laden GaN semiconductor plasmas. It is assumed that ions are implanted to form colloids in the GaN sample. The colloids are continuously bombarded by the plasma particles and stick on them, but they acquire a net negative charge due to relatively higher mobility of electrons. It is found from the dispersion relation that the presence of charged colloids not only modifies the existing modes but also supports new novel modes of LEKWs. It is hoped that the study would enhance understanding on dispersion and absorption of LEKWs and help in singling out the appropriate configurations in which GaN crystal would be better suited for fabrication of microwave devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fracture dynamics in implanted silicon

Crack propagation in implanted silicon for thin layer transfer is experimentally studied. The crack propagation velocity as a function of split temperature is measured using a designed optical setup. Interferometric measurement of the gap opening is performed dynamically and shows an oscillatory crack “wake” with a typical wavelength in the centimetre range. The dynamics of this motion is modelled using beam elasticity and thermodynamics. The modelling demonstrates the key role of external atmospheric pressure during crack propagation. A quantification of the amount of gas trapped inside pre-existing microcracks and released during the fracture is made possible, with results consistent with previous studies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of nitrogen-related defects on visible light photocatalytic response in N{sup +} implanted TiO{sub 2}: A first-principles study

It was found that the visible-light responsiveness of a nitrogen ion-implanted TiO{sub 2} photocatalyst was attributable to the predominant chemical states of nitrogen, depending on the local nitrogen concentration near the surface. In the present study, we examined the effects of conceivable nitrogen-related defects on the visible light responsiveness, based on electronic structures calculated from first principles. Possible chemical states were proposed by comparing previously reported experiments with the present theoretical N-K X-ray absorption spectra. The theoretically predicted visible light absorption spectra and carrier trap states due to the bandgap states associated with the defects well explained the relationship between the catalytic reactivity and the proposed chemical states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TEM investigation of the surface layer structure [111]{sub B2} of the single NiTi crystal modified by the Si-ion beam implantation

The study was carried on for the single NiTi crystals subjected to the Si-ion beam implantation. Using the transmission electron microscopy technique (TEM), the surface layer structure [111]{sub B2} was examined for the treated material. The modified near-surface sublayers were found to have different composition. Thus the uppermost sublayer contained mostly oxides; the lower-lying modified sublayer material was in an amorphous state and the thin underlying sublayer had a defect structure.

36 MATERIALS SCIENCE↗

Sol-gel synthesis and characterization of SiO{sub 2}/PEG hybrid materials containing quercetin as implants with antioxidant properties

In the present work, Silica/Polyethylene glycol (PEG) hybrid nanocomposites containing an antioxidant agent, the quercetin, were synthesized via sol-gel to be used as implants with antioxidant properties. Fourier transform infrared (FT-IR) analysis proved that a modification of both polymer and quercetin occurs due to synthesis process. Scanning electron microscope (SEM) showed that the proposed materials were hybrid nanocomposites. The bioactivity was ascertained by soaking the samples in a simulated body fluid (SBF).

36 MATERIALS SCIENCE↗

Measuring sub-surface spatially varying thermal conductivity of silicon implanted with krypton

The thermal properties of semiconductors following exposure to ion irradiation are of great interest for the cooling of electronic devices; however, gradients in composition and structure due to irradiation often make the measurement difficult. Furthermore, the nature of spatial variations in thermal resistances due to spatially varying ion irradiation damage is not well understood. In this work, we develop an advancement in the analysis of time-domain thermoreflectance to account for spatially varying thermal conductivity in a material resulting from a spatial distribution of defects. We then use this method to measure the near-surface (≲1 μm) thermal conductivity of silicon wafers irradiated with Kr + ions, which has an approximate Gaussian distribution centered 260 nm into the sample. Our numerical analysis presented here allows for the spatial gradient of thermal conductivity to be extracted via what is fundamentally a volumetric measurement technique. We validate our findings via transmission electron microscopy, which is able to confirm the spatial variation of the sub-surface silicon structure, and provide additional insight into the local structure resulting from the effects of ion bombardment. Thermal measurements found the ion stopping region to have a nearly 50x reduction in thermal conductivity as compared to pristine silicon, while TEM showed the region was not fully amorphized. Our results suggest this drastic reduction in silicon thermal conductivity is primarily driven by structural defects in crystalline regions along with boundary scattering between amorphous and crystalline regions, with a negligible contribution being due to implanted krypton ions themselves.

36 MATERIALS SCIENCE↗

Polarization rotation in a ferroelectric BaTiO 3 film through low-energy He-implantation

Domain engineering in ferroelectric thin films is crucial for next-generation microelectronic and photonic technologies. Here, a method is demonstrated to precisely control domain configurations in BaTiO 3 thin films through low-energy He ion implantation. The approach transforms a mixed ferroelectric domain state with significant in-plane polarization into a uniform out-of-plane tetragonal phase by selectively modifying the strain state in the film’s top region. This structural transition significantly improves domain homogeneity and reduces polarization imprint, leading to symmetric ferroelectric switching characteristics. The demonstrated ability to manipulate ferroelectric domains post-growth enables tailored functional properties without compromising the coherently strained bottom interface. The method’s compatibility with semiconductor processing and ability to selectively modify specific regions make it particularly promising for practical implementation in integrated devices. This work establishes a versatile approach for strain-mediated domain engineering that could be extended to a wide range of ferroelectric systems, providing new opportunities for memory, sensing, and photonic applications where precise control of polarization states is essential.

36 MATERIALS SCIENCE↗

Enhanced Electrical Activation in In-Implanted Si 0.35 Ge 0.65 by C Co-Doping

In this report, we have achieved a significant increase in the electrically active dopant fraction in Indium (In)-implanted Si 0.35 Ge 0.65 , by co-doping with the isovalent element Carbon (C). Electrical measurements have been correlated with X-ray absorption spectroscopy to determine the electrical properties and the In atom lattice location. With C+In co-doping, the solid solubility of In in Si 0.35 Ge 0.65 was at least tripled from between 0.02 and 0.06 at% to between 0.2 and 0.6 at% as a result of C–In pair formation, which suppressed In metal precipitation. A dramatic improvement of electrical properties was thus attained in the co-doped samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deterministic nanoscale quantum spin-defect implantation and diffraction strain imaging

Abstract Local crystallographic features negatively affect quantum spin defects by changing the local electrostatic environment, often resulting in degraded or varied qubit optical and coherence properties. Few tools exist that enable the deterministic synthesis and study of such intricate systems on the nano-scale, making defect-to-defect strain environment quantification difficult. In this paper, we highlight state-of-the-art capabilities from the U.S. Department of Energy’s Nanoscale Science Research Centers that directly address these shortcomings. Specifically, we demonstrate how complementary capabilities of nano-implantation and nano-diffraction can be used to demonstrate the quantum relevant, spatially deterministic creation of neutral divacancy centers in 4H silicon carbide, while investigating and characterizing these systems on the ≤ 25 nm scale with strain sensitivities on the order of 1 × 10 − 6 , relevant to defect formation dynamics. This work lays the foundation for ongoing studies into the dynamics and deterministic formation of low strain homogeneous quantum relevant spin defects in the solid state.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multi-beam RF Accelerators for Ion Implantation

We report on the development of a radio frequency (RF) linear accelerator (linac) for multiple-ion beams that is made from stacks of low cost wafers. The accelerator lattice is comprised of RF-acceleration gaps and electrostatic quadrupole focusing elements that are fabricated on 4' wafers made from printed circuit board or silicon. We demonstrate ion acceleration with an effective gradient of about 0.5MVm-1 with an array of 3 × 3 beams. The total ion beam energies achieved to date are in the 10 keV range with total ion currents in tests with noble gases of ~0.1mA. We discuss scaling of the ion energy (by adding acceleration modules) and ion currents (with more beams) for applications of this multi-beam RF linac technology to ion implantation and surface modification of materials.

Seidl, Peter A.↗

Survival, growth and tag retention of juvenile European eel ( Anguilla anguilla L.) with implanted 12 mm passive integrated transponder tags and acoustic tags

To evaluate the efficiency of tagging juvenile European eels with implanted 12 mm passive integrated transponder (PIT) tags or Eel/Lamprey acoustic transmitters (ELATs), the authors studied tag retention, survival and growth of eels (7–25 g). Experimental eels were obtained from an eel farm, tagged and then released in a series of shallow dug-out ponds with a surface area of c. 200 m 2 . Tagged and control eels were distributed evenly, with 50 tagged and 50 control eels in each of four ponds, giving a total of 200 tagged and 200 control eels mixed. After 76 days, the ponds were drained, and eels were sampled and measured. A total of 344 eels (86%) were recaptured, indicating high survival. Tag retention was 99% as only one of the recaptured PIT-tagged eels had lost the tag and none of the ELAT tagged. The results demonstrated that tagging juvenile eels >16 cm with these small tags is indeed feasible. The growth of tagged and control fish was differentiated but generally low in length and negative in mass but did not differ between the three groups.

54 ENVIRONMENTAL SCIENCES↗

Technologies for Prolonging Cardiac Implantable Electronic Device Longevity

Prolonged longevity of cardiac implantable electronic devices (CIEDs) is needed not only as a passive response to match the prolonging life expectancy of patient recipients, but will also actively prolong their life expectancy by avoiding/deferring the risks (and costs) associated with device replacement. CIEDs are still exclusively powered by nonrechargeable primary batteries, and energy exhaustion is the dominant and an inevitable cause of device replacement. The longevity of a CIED is thus determined by the attrition rate of its finite energy reserve. The energy available from a battery depends on its capacity (total amount of electric charge), chemistry (anode, cathode, and electrolyte), and internal architecture (stacked plate, folded plate, and spiral wound). The energy uses of a CIED vary and include a background current for running electronic circuitry, periodic radiofrequency telemetry, high‐voltage capacitor reformation, constant ventricular pacing, and sporadic shocks for the cardiac resynchronization therapy defibrillators. The energy use by a CIED is primarily determined by the patient recipient's clinical needs, but the energy stored in the device battery is entirely under the manufacturer's control. A larger battery capacity generally results in a longer‐lasting device, but improved battery chemistry and architecture may allow more space‐efficient designs. Armed with the necessary technical knowledge, healthcare professionals and purchasers will be empowered to make judicious selection on device models and maximize the utilization of all their energy‐saving features, to prolong device longevity for the benefits of their patients and healthcare systems.

LAU, ERNEST W.↗

Response of an implantable MOSFET dosimeter to {sup 192}Ir HDR radiation

New in vivo dosimetry methods would be useful for clinical HDR brachytherapy. An implantable MOSFET Dose Verification System designed by Sicel Technologies, Inc. was examined for use with {sup 192}Ir HDR applications. This investigation demonstrated that varying the dose rate from 22 to 84 cGy/min did not change detector response. The detectors exhibited a higher sensitivity to {sup 192}Ir energies than {sup 60}Co energies. A nonlinear accumulated dose effect was characterized by three third-order polynomials fit to data from detectors placed at three different distances from the source. The detectors were found to have minimal rotational angular dependence. A strong longitudinal angular dependence was found when the detector's copper coil and electronics assembly were aligned between the MOSFETs and incident radiation. This orientation showed a 16% decrease in response relative to other orientations tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of an implantable MOSFET dosimeter designed for use with hypofractionated external beam treatments and its applications for breast and prostate treatments

Purpose: An implantable metal-oxide semiconductor field effect transistors-based dosimeter has recently been developed for the in vivo monitoring of hypofractionated radiotherapy. This DVS-HFT dosimeter is designed for fraction sizes of 340-950 cGy and can also be used for bis in die fraction monitoring. The current work reports on the testing and evaluation of this dosimeter, including both its basic characteristics as well as its performance during simulated clinical treatment plans. Methods: The authors tested the dose rate dependence of this dosimeter (300 MU/min versus 600 MU/min), the treatment time dependence (4 min per treatment versus up to 60 min per treatment), and the dose and energy dependence (6 and 18 MV irradiations of 700-900 cGy per fraction). Additionally, they irradiated the detectors in-phantom with breast and prostate hypofractionated treatments. Results: The detectors showed no significant dose rate, treatment time, energy, or dose dependence. Furthermore, the detectors were found to perform within manufacturer tolerances for all hypofractionated treatments examined, accurately reporting the measured dose (average disagreement of - 0.65%). Conclusions: These dosimeters appear well suited for in vivo monitoring of hypofractionated radiotherapy doses, and thereby, have the potential to improve patient care.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-145: Effects of Temporary Tachytherapy Inhibition Magnet On MOSFET Dose Measurements of Cardiovascular Implantable Electronic Devices (CIED) in Radiation Therapy Patients

Purpose: To determine the effects of temporary tachytherapy inhibition magnet on MOSFET dose measurements of cardiovascular implantable electronic devices (CIED) in radiation therapy patients. Methods: Infield and peripheral MOSFET dose measurements with 6MV photon beams were performed to evaluate dose to a CIED in the presence of a doughnut shaped temporary tachytherapy inhibition magnet. Infield measurements were done to quantify the effects of the magnetic field alone and shielding by the magnet. MOSFETs were placed inside a 20×20cm{sup 2} field at a depth of 3cm in the isocentre plane in the presence and absence of the magnet. Peripheral dose measurements were done to determine the impact of the magnet on dose to the CIED in a clinical setting. These measurements were performed at the centre, under the rim and half way between a 10×10cm{sup 2} field edge and the magnet with MOSFETS placed at the surface, 0.5cm and 1cm depths in the presence and absence of the magnet. Results: Infield measurements showed that effects of magnetic field on the MOSFET readings were within the 2% MOSFET dose measurement uncertainty; a 20% attenuation of dose under the magnet rim was observed. Peripheral dose measurements at the centre of the magnet show an 8% increase in surface dose and a 6% decrease in dose at 1cm depth. Dose under the magnet rim was reduced by approximately 68%, 45% and 25% for MOSFET placed at 0.0, 0.5 and 1.0cm bolus depths, respectively. Conclusions: The magnetic field has an insignificant effect on MOSFET dose measurements. Dose to the central region of CIED represented by centre of the magnet doughnut increases at the surface, and decreases at depths due to low energy scattering contributions from the magnet. Dose under the magnet rim, representing CIED edges, decreased significantly due to shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement of registration accuracy in accelerated partial breast irradiation using the point-based rigid-body registration algorithm for patients with implanted fiducial markers

Purpose: To investigate image-registration errors when using fiducial markers with a manual method and the point-based rigid-body registration (PRBR) algorithm in accelerated partial breast irradiation (APBI) patients, with accompanying fiducial deviations. Methods: Twenty-two consecutive patients were enrolled in a prospective trial examining 10-fraction APBI. Titanium clips were implanted intraoperatively around the seroma in all patients. For image-registration, the positions of the clips in daily kV x-ray images were matched to those in the planning digitally reconstructed radiographs. Fiducial and gravity registration errors (FREs and GREs, respectively), representing resulting misalignments of the edge and center of the target, respectively, were compared between the manual and algorithm-based methods. Results: In total, 218 fractions were evaluated. Although the mean FRE/GRE values for the manual and algorithm-based methods were within 3 mm (2.3/1.7 and 1.3/0.4 mm, respectively), the percentages of fractions where FRE/GRE exceeded 3 mm using the manual and algorithm-based methods were 18.8%/7.3% and 0%/0%, respectively. Manual registration resulted in 18.6% of patients with fractions of FRE/GRE exceeding 5 mm. The patients with larger clip deviation had significantly more fractions showing large FRE/GRE using manual registration. Conclusions: For image-registration using fiducial markers in APBI, the manual registration results in more fractions with considerable registration error due to loss of fiducial objectivity resulting from their deviation. The authors recommend the PRBR algorithm as a safe and effective strategy for accurate, image-guided registration and PTV margin reduction.

60 APPLIED LIFE SCIENCES↗

A DLTS study of 4H-SiC-based p-n junctions fabricated by boron implantation

Deep-level transient spectroscopy (DLTS) has been used to study p-n junctions fabricated by implantation of boron into epitaxial 4H-SiC films with n-type conductivity and the donor concentration (8-9) Multiplication-Sign 10{sup 14} cm{sup -3}. A DLTS signal anomalous in sign is observed; this signal is related to recharging of deep compensating boron-involved centers in the n-type region near the metallurgical boundary of the p-n junction.

36 MATERIALS SCIENCE↗