Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat pump”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Solar one - The Delaware solar house and results obtained during the first year of operation

The design of a system which uses CdS/Cu2S solar cells to convert solar energy into electricity and heat, and which uses a heat pump for auxiliary heating and air conditioning is discussed. Salt hydrates are used for heat storage, while air serves as the heat transfer medium. The operational parameters and economic aspects of the system are examined, and preliminary test results are analyzed.

Boeer, K. W.↗

Preliminary design package for solar heating and cooling systems

Summarized preliminary design information on activities associated with the development, delivery and support of solar heating and cooling systems is given. These systems are for single family dwellings and commercial applications. The heating/cooling system use a reversible vapor compression heat pump that is driven in the cooling mode by a Rankine power loop, and in the heating mode by a variable speed electric motor. The heating/cooling systems differ from the heating-only systems in the arrangement of the heat pump subsystem and the addition of a cooling tower to provide the heat sink for cooling mode operation.

Source record↗

Solar heated two level residence--Akron, Ohio

Report describes 1 year evaluation of solar heating and hot water system which satisfied 24 percent of energy requirements. System uses flat plate solar collectors with air as heat transport medium. Rock storage bin stores collected energy; air to liquid heat pump supplies backup heat.

Source record↗

Modeling of Heat and Mass Transfer in a TEC-Driven Lyophilizer

Dewatering of wet waste during space exploration missions is important for crew safety as it stabilizes the waste. It may also be used to recover water and serve as a preconditioning step for waste compaction. A thermoelectric cooler (TEC)-driven lyophilizer is under development at NASA Ames Research Center for this purpose. It has three major components: (i) an evaporator section where water vapor sublimes from the frozen waste, (ii) a condenser section where this water vapor deposits as ice, and (iii) a TEC section which serves as a heat pump to transfer heat from the condenser to the evaporator. This paper analyses the heat and mass transfer processes in the lyophilizer in an effort to understand the ice formation behavior in the condenser. The analysis is supported by experimental observations of ice formation patterns in two different condenser units.

Yuan, Zeng-Guang↗

Innovative Multi-Environment, Multimode Thermal Control System

Innovative multi-environment multimode thermal management architecture has been described that is capable of meeting widely varying thermal control requirements of various exploration mission scenarios currently under consideration. The proposed system is capable of operating in a single-phase or two-phase mode rejecting heat to the colder environment, operating in a two-phase mode with heat pump for rejecting heat to a warm environment, as well as using evaporative phasechange cooling for the mission phases where the radiator is incapable of rejecting the required heat. A single fluid loop can be used internal and external to the spacecraft for the acquisition, transport and rejection of heat by the selection of a working fluid that meets NASA safety requirements. Such a system may not be optimal for each individual mode of operation but its ability to function in multiple modes may permit global optimization of the thermal control system. The architecture also allows flexibility in partitioning of components between the various Constellation modules to take advantage of operational requirements in various modes consistent with the mission needs. Preliminary design calculations using R-134 as working fluid show the concept to be feasible to meet the heat rejection requirements that are representative of the Crew Exploration Vehicle and Lunar Access Module for nominal cases. More detailed analyses to establish performance under various modes and environmental conditions are underway.

Singh, Bhim S.↗

Microscale Regenerative Heat Exchanger

The device described herein is designed primarily for use as a regenerative heat exchanger in a miniature Stirling engine or Stirling-cycle heat pump. A regenerative heat exchanger (sometimes called, simply, a "regenerator" in the Stirling-engine art) is basically a thermal capacitor: Its role in the Stirling cycle is to alternately accept heat from, then deliver heat to, an oscillating flow of a working fluid between compression and expansion volumes, without introducing an excessive pressure drop. These volumes are at different temperatures, and conduction of heat between these volumes is undesirable because it reduces the energy-conversion efficiency of the Stirling cycle.

Moran, Matthew E.↗

Spacesuit Evaporator-Absorber-Radiator (SEAR)

For decades advanced spacesuit developers have pursued a regenerable, robust non-venting system for heat rejection. Toward this end, this paper investigates linking together two previously developed technologies, namely NASA's Spacesuit Water Membrane Evaporator (SWME), and Creare's lithium chloride Heat Pump Radiator (HPR). Heat from a liquid cooled garment is transported to SWME that provides cooling through evaporation. The SEAR is evacuated at the onset of operations and thereafter, the water vapor absorption rate of the HPR maintains a low pressure environment for the SWME to evaporate effectively. This water vapor captured by solid LiCl in the HPR with a high enthalpy of absorption, results in sufficient temperature lift to reject most of the heat to space by radiation. After the sortie, the HPR would be heated up in a regenerator to drive off and recover the absorbed evaporant. A one-fourth scale prototype was built and tested in vacuum conditions at a sink temperature of 250 K. The HPR was able to stably reject 60 W over a 7-hour period. A conceptual design of a full-scale radiator is proposed. Excess heat rejection above 240 W would be accomplished through venting of the evaporant. Loop closure rates were predicted for various exploration environment scenarios.

Bue, Grant C.↗

Cascade Distiller System Performance Testing Interim Results

The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

Callahan, Michael R.↗

High Performance Residential Housing Units at U.S. Coast Guard Base Kodiak: Preprint

The United States Coast Guard (USCG) constructs residential housing throughout the country using a basic template that must meet the minimum Leadership in Energy and Environmental Design (LEED) Silver criteria or better for the units. In Kodiak, Alaska, USCG is procuring between 24 and 100 residential multi-family housing units. Priorities for the Kodiak project were to reduce overall energyconsumption by at least 20% over existing units, improve envelope construction, and evaluate space heating options. USCG is challenged with maintaining similar existing units that have complicated residential diesel boilers. Additionally, fuel and material costs are high in Kodiak. While USCG has worked to optimize the performance of the housing units with principles of improved buildingenvelope, the engineers realize there are still opportunities for improvement, especially within the heating, ventilation, and air conditioning (HVAC) system and different envelope measures. USCG staff also desires to balance higher upfront project costs for significantly reduced life-cycle costs of the residential units that have an expected lifetime of 50 or more years. To answer thesequestions, this analysis used the residential modeling tool BEoptE+ to examine potential energy- saving opportunities for the climate. The results suggest criteria for achieving optimized housing performance at the lowest cost. USCG will integrate the criteria into their procurement process. To achieve greater than 50% energy savings, USCG will need to specify full 2x 6 wood stud R-21 insulationwith two 2 inches of exterior foam, R-38 ceiling insulation or even wall insulation in the crawl space, and R-49 fiberglass batts in a the vented attic. The air barrier should be improved to ensure a tight envelope with minimal infiltration to the goal of 2.0 ACH50. With the implementation of an air source heat pump for space heating requirements, the combination of HVAC and envelope savings inthe residential unit can save up to 58% in source energy over existing residential units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance, Cost, and Financial Parameters of Geothermal District Heating Systems for Market Penetration Modeling under Various Scenarios

Geothermal district heating (GDH) systems have limited penetration in the U.S., with an estimated installed capacity of only 100 MWth for a total of 21 sites. We see higher deployment in other regions, for example, in Europe with an installed capacity of more than 4,700 MWth for 257 GDH sites. The U.S. Department of Energy Geothermal Vision (GeoVision) Study is currently looking at the potential to increase the deployment in the U.S. and to understand the impact of this increased deployment. This paper reviews 31 performance, cost, and financial parameters as input for numerical simulations describing GDH system deployment in support of the GeoVision effort. The focus is on GDH systems using hydrothermal and Enhanced Geothermal System resources in the U.S.; ground-source heat pumps and heat-to-electricity conversion technology were excluded. Parameters investigated include 1) capital and operation and maintenance costs for both subsurface and surface equipment; 2) performance factors such as resource recovery factors, well flow rates, and system efficiencies; and 3) financial parameters such as inflation, interest, and tax rates. Current values as well as potential future improved values under various scenarios are presented. Sources of data considered include academic and popular literature, software tools such as GETEM and GEOPHIRES, industry interviews, and analysis conducted by other task forces for the GeoVision Study, e.g., on the drilling costs and reservoir performance.

15 GEOTHERMAL ENERGY↗

Heating and cooling devices, systems and related method

Embodiments disclosed herein relate to devices, systems, and methods for cooling and/or heating a medium as well as cooling and/or heating an environment containing the medium. More specifically, at least one embodiment includes a heat pump that may heat and/or cool a medium and, in some instances, may transfer heat from one location to another location.

42 ENGINEERING↗

Thermoelastic cooling

A cooling system based on thermoelastic effect is provided. The system comprises a heat sink, a refrigerated space and a regenerator coupled to the refrigerated space and to the heat sink to pump heat from the refrigerated space to the heat sink. The regenerator comprises solid thermoelastic refrigerant materials capable of absorbing or releasing heat.

Cui, Jun↗

Compact thermoelastic cooling system

A compact cooling system based on thermoelastic effect is provided. In one embodiment, the system comprises a pair of rollers serving as a heat sink, stress applicator and belt drive, a cold reservoir and a solid refrigerant belt coupled to the cold reservoir and to the heat sinks to pump heat from the cold reservoir to the heat sink. The refrigerant belt comprises solid thermoelastic materials capable of thermoelastic effect. The refrigerant material is mechanically compressed when entering the gap of the roller and subsequently released after passing through. When compressed the refrigerant material transforms to martensite phase and releases heat to the roller and neighboring materials. After released by the rollers, the refrigerant material transforms back to austenite and absorbs heat from the ambient atmosphere.

42 ENGINEERING↗

Heating and cooling devices, systems and related method

Embodiments disclosed herein relate to devices, systems, and methods for cooling and/or heating a medium as well as cooling and/or heating an environment containing the medium. More specifically, at least one embodiment includes a heat pump that may heat and/or cool a medium and, in some instances, may transfer heat from one location to another location.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermoelastic cooling

A cooling system based on thermoelastic effect is provided. The system comprises a heat sink, a refrigerated space and a regenerator coupled to the refrigerated space and to the heat sink to pump heat from the refrigerated space to the heat sink. The regenerator comprises solid thermoelastic refrigerant materials capable of absorbing or releasing heat.

42 ENGINEERING↗

Heating and cooling devices, systems and related method

Embodiments disclosed herein relate to devices, systems, and methods for cooling and/or heating a medium as well as cooling and/or heating an environment containing the medium. More specifically, at least one embodiment includes a heat pump that may heat and/or cool a medium and, in some instances, may transfer heat from one location to another location.

Kariya, Harumichi Arthur↗

Energy dataset of Frontier supercomputer for waste heat recovery

The Hewlett Packard Enterprise–Cray EX Frontier is the world’s first and fastest exascale supercomputer, hosted at the Oak Ridge Leadership Computing Facility in Tennessee, United States. Frontier is a significant electricity consumer, drawing 8–30 MW; this massive energy demand produces significant waste heat, requiring extensive cooling measures. Although harnessing this waste heat for campus heating is a sustainability goal at Oak Ridge National Laboratory (ORNL), the 30 °C–38 °C waste heat temperature poses compatibility issues with standard HVAC systems. Heat pump systems, prevalent in residential settings and some industries, can efficiently upgrade low-quality heat to usable energy for buildings. Thus, heat pump technology powered by renewable electricity offers an efficient, cost-effective solution for substantial waste heat recovery. However, a major challenge is the absence of benchmark data on high-performance computing (HPC) heat generation and waste heat profiles. This paper reports power demand and waste heat measurements from an ORNL HPC data centre, aiming to guide future research on optimizing waste heat recovery in large-scale data centres, especially those of HPC calibre.

97 MATHEMATICS AND COMPUTING↗

Evaluation of the Impacts of Heat Exchanger Operation on Quality of Water Used as Heat Source and Sink

To help inform future decisions about the subsequent uses of water that has served as a heat source and sink in the heat exchanger component of a geothermal heat pump system, ORNL performed an independent assessment of data characterizing the quality of water that had passed through a heat exchanger supporting a geothermal heat pump in a school building. Water supply to the heat exchanger is treated drinking water from a public water supply system that derives its water from a groundwater source. Water analyses and bacteriological measurements collected from heat exchanger and inflow and outflow lines were supplied to ORNL for review. Data were compared with regulatory standards and inflow and outflow data were compared to identify changes occurring in the water resulting from its passage through the heat exchanger. Review of the data identified no conditions that would prevent the use of heat exchange outflow water for water supply. Water quality conforms with applicable regulatory standards. There were no discernible differences between inflow and outflow water quality for any parameters other than water temperature and formation of heterotrophic bacterial biofilms. Changes in water temperature are an expected result of the operation of the heat exchanger system and do not by themselves affect the suitability of the water for human consumption. Bacterial biofilm formation can be affected by water temperature, but the data did not show a consistent or statistically significant relationship between temperature parameters and biofilm formation, and the observations of biofilms formed in the heat exchanger water lines do not affect the suitability of the outflow water for water supply. Legionella, a bacterial genus that has been associated with outbreaks of waterborne pathogenic disease, was detected in one biofilm sample, and the water company is performing follow-up testing to assess the significance of this detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗