Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Modeling of Transport Processes in Liquid-Metal Fusion Blankets: Past, Present, and Future

The successful development of robust breeding blanket systems will strongly rely on computational tools for predicting the complex behavior of the electrically conducting liquid-metal (LM) breeder flowing in the complex-shaped blanket ducts in the presence of a strong plasma-confining magnetic field, volumetric heating, and tritium generation. Associated transport processes involve magnetohydrodynamic (MHD) flows, heat transfer, corrosion, and tritium transport. This paper is an overview of past and present efforts in the development, application, and verification and validation (V&V) of such computational tools. As a result of the ongoing campaign on V&V of computer codes for LM blankets, the international fusion community has identified several candidates that promise to become real blanket design and analysis tools in the near future. Among them are HIMAG, MHD-UCAS, COMSOL Multiphysics, ANSYS FLUENT, ANSYS CFX, and OpenFOAM. The progress, over the last decade, in the application of such codes in blanket studies is tremendous. This is illustrated with two examples for a dual-coolant lead-lithium (DCLL) blanket: (1) integrated computer modeling for the recently designed DCLL blanket in the United States and (2) application of the code MHD-UCAS to the analysis of PbLi flows and heat transfer in a generic DCLL blanket prototype at high Hartmann (Ha ~ 10 4 ) and Grashof numbers (Gr ~ 10 12 ). Here, this paper also presents an approach to the development of a new integrated computational tool called the virtual dual-coolant lead-lithium (VDCLL) blanket, which elaborates the existing U.S. MHD code HIMAG.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance evaluation of finned tube heat exchanger using curved wavy delta winglet vortex generators with circular perforations

Vortex generation is recognized as an effective passive approach to improve the heat transfer rate in fin and tube heat exchangers (FTHEs). The current study proposed innovative designs of curved wavy delta winglet vortex generators (CWDWVGs), both without and with circular perforations, to improve the heat transfer efficiency of FTHEs. There is potential to increase heat transfer performance further through various CWDWVG designs. Here, this study explores seven unique CWDWVG configurations, from 1-wave to 7-wave. A 3-D computational numerical model is utilized to evaluate the Thermo-hydraulic performance of FTHEs fitted with these different CWDWVG configurations across Reynolds numbers from 400 to 2000. This comparative analysis of the Thermo-hydraulic performance of FTHEs featuring four parallel circular tube layouts assesses configurations both with and without vortex generators (VGs) and various hole configurations. The evaluation of Thermo-hydraulic performance involves different parameters, including the London area goodness factor (LAGF), Colburn factor (j), friction factor (f), pressure drop (?P), and Nusselt number (Nu). Results demonstrate that the various CWDWVG configurations and the number of holes in them substantially affect the efficiency, as evaluated by the dimensionless Performance Evaluation Criteria (PEC). Notably, the 7-wave CWDWVGs surpassed other configurations, and integrating circular punched perforations further improved the thermal-hydraulic performance of FTHE. Specifically, the 7-wave CWDWVGs without holes demonstrated superior performance over other configurations, showing a significant increase in Nusselt number by 75.18% and 85.16% at Reynolds numbers of 2000 and 400, respectively, alongside an increase in pressure drop by 216.38% to 224.96%. Meanwhile, the 7-wave CWDWVGs with eight holes, in comparison to those without holes, exhibited a Nusselt number increase of 0.85%, a pressure drop decrease of 7.31%, and a reduction in the friction factor by 5.82%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Exchanger Performance Impacts on Optimum Cost Conditions in Thermoelectric Energy Recovery Designs

Cost is just as important as power density or efficiency for the adoption of waste heat recovery thermoelectric generators (TEG). Prior work [1] has shown that the system design that minimizes cost (e.g., the $/W value) can be close to the designs that maximize the system’s efficiency or power density, however, it is important to understand the relationship between those designs to optimize TEG performance-cost compromises. Expanding on recent work [1, 2, 3] the impact of heat exchanger conditions on the optimum TEG fill factors and cost scaling of a waste heat recovery thermoelectric generator with a detailed treatment of the hot side exhaust heat exchanger has been investigated further. The effect of the heat lost to the environment and updated relationships between the hot-side and cold-side conductances [4] that maximize power output are considered. The optimum fill factor to minimize TEG energy recovery system costs is strongly dependent on the heat leakage fraction, σ, the mass flow rate of the exhaust, the hot-side heat exchanger effectiveness, heat exchanger UAh, and heat flux. These relationships are explored and characterized for typical exhaust gas-flow conditions to show the inherent design complexities. The heat exchanger costs often dominate the TEG cost equation and it is critical to fully understand the tradeoff between heat exchanger performance, optimum TEG fill factors, and cost to establish potentially optimum design points within the cost-performance design space. This work will explore the design tradeoffs and relationships within the cost-efficiency-power density design space for a typical thermoelectric energy recovery system application. The interplay between optimum TEG fill factors and heat exchanger design can impact system footprint, volume, and mass in weight-sensitive applications. Less-effective, low-cost heat exchangers may outperform higher cost alternatives from a market adoption perspective. This shift of emphasis acknowledging the interdependence of optimum TEG fill factors and heat exchanger performance has significant implications on thermoelectric waste heat recovery systems designs and their operation. In addition, preferred TEG design regimes exist that accommodate reasonable compromises in TE performance and cost. This effort highlights how the optimum fill factor–heat exchanger performance relations couple to these optimum TEG performance-cost domains based on TEG-system-level analyses and provides a focus for future system research and development efforts.

Energy recovery↗

High Efficiency Waste Heat Harvesting Using Novel Thermal Oscillators

The aim of this project was to enable practical energy generation from waste heat using pyroelectric (PE) materials with unprecedented efficiency. This aim was accomplished by engineering novel heat switches that overcome the current roadblock to pyroelectric energy harvesting. The heat switches produce a sustain temporal temperature differences from a constant flux heat source. Pyroelectric materials produce transient voltages in response to this generated temperature oscillation. The project solved the inability to generate sustained temperature cycles by utilizing LCEs to achieve passive thermal switching, or EDH of thermal fluid to actively bridging/de-bridging between heat source and pyroelectric layer.

30 DIRECT ENERGY CONVERSION↗

Physical mechanisms of heat, momentum and turbulence fluxes

In a qualitative way, the physical mechanisms which generate fluxes of heat, momentum, and turbulence in the atmosphere are discussed. This material is presented to acquaint people with the Earth science aspects of turbulence as important processes in the atmosphere. To attempt to describe turbulent fluxes of heat, momentum, and moisture in precise mathematical detail becomes an intractable problem. It is burdened by an eighth order set of equations involving more variables than equations. It is a closure problem which requires complicated assumptions that are not necessarily always satisfied, variable boundary conditions, and sparse observational data. Therefore, we must approach the problem in a simplified manner to obtain any kind of solution involving the variables of shear, stress, and heat, moisture, and momentum fluxes. There are other problems, of course, in which the inclusion of the planetary boundary layer is extremely important. Air pollution studies, air-sea exchanges, mesoscale models, and so on, must account for the planetary layer in very specific terms. Some of the physical mechanisms that are involved in generating fluxes are described.

Theon, John S.↗

Radiative Heating Rates Computed With Clouds Derived From Satellite‐Based Passive and Active Sensors and their Effects on Generation of Available Potential Energy

Radiative heating rates computed with cloud properties derived from passive and active sensors are investigated. Zonal monthly radiative heating rate anomalies computed using both active and passive sensors show that larger variability in longwave cooling exists near the tropical tropopause and near the top of the boundary layer between ~50°N to ~50°S. Aerosol variability contributes to increases in shortwave heating rate variability. When zonal monthly mean cloud effects on the radiative heating rate computed with both active and passive sensors and those computed with passive sensor only are compared, the latter shows cooling and heating peaks corresponding to cloud top and base height ranges used for separating cloud types. The difference of these two sets of cloud radiative effect on heating rates in the middle to upper troposphere is larger than the radiative heating rate uncertainty estimated based on the difference of two active sensor radiative heating rate profile data products. In addition, radiative heating rate contribution to generation of eddy available potential energy is also investigated. Although radiation contribution to generation of eddy available potential energy averaged over a year and the entire globe is small, radiation increases the eddy available potential energy in the northern hemisphere during summer. Two key elements that longwave radiation contribute to the generation of eddy potential energy are (1) longitudinal temperature gradient in the atmosphere associated with land and ocean surface temperatures contrasts and absorption of longwave radiation emitted by the surface and (2) cooling near the cloud top of stratocumulus clouds.

Kato, Seiji↗

Molten salt thermal energy storage for utility peaking loads

This paper considers the use of thermal energy storage (TES) in molten salts to increase the capacity of power plants. Five existing fossil and nuclear electric utility plants were selected as representative of current technology. A review of system load diagrams indicated that TES to meet loads over 95% of peak was a reasonable goal. Alternate TES heat exchanger locations were evaluated, showing that the stored energy should be used either for feedwater heating or to generate steam for an auxiliary power cycle. Specific salts for each concept are recommended. Design layouts were prepared for one plant, and it was shown that a TES tube/shell heat exchanger system could provide about 7% peaking capability at lower cost than adding steam generation capacity. Promising alternate heat exchanger concepts were also identified.

Ferrara, A.↗

Cyber-Attack Detection and Accommodation for the Energy Delivery System

The goals of this project were to create a software system with a suite of key algorithms for cyber-attack detection and accommodation providing domain layer protection for critical power generation assets. Example assets included gas and steam turbines, heat recovery steam generators, and electrical generators. The aggressive algorithm goals were aimed at reducing the false positive rates in threat detection to <1% using learnings from many evolving disciplines (power turbine and generator physics, power system modeling, modern control theory, system identification, machine learning, deep learning, mathematics and data science). Additional goals for the algorithms involved localizing threats on-the-fly to know in which monitoring node the effects of attacks are present, and then providing accommodation to keep the system running uninterrupted much of the time in the presence of the attack. Accommodation had a performance goal of providing resiliency when up to 50% of monitoring nodes are in an attack state.

cybersecurity, cyber-physical↗

Scoping Thermal Response Calculations of RNS Waste During Transport to and Disposal at the WIPP

Sandia National Laboratories (SNL) was contracted by the United States Department of Energy Environmental Management (DOE-EM), Los Alamos Field Office to perform mechanical and thermal scoping calculations as part of a study seeking to understand the ignitability risk of the Remediated Nitrate Salts (RNS) waste drums during transportation from the Waste Control Specialists (WCS) facility to Waste Isolation Pilot Plant (WIPP) and permanent disposal of the waste at WIPP. The scoping thermal simulations described in this report pertain to thermal calculations performed with a packaging system consisting of one Standard Waste Box (SWB) loaded with drums placed inside a Standard Large Box 2 (SLB2). During transportation, the SLB2 is inside Transuranic Package Transporter Model III (TRUPACT-III), which provides the third layer of the packaging. Once at the WIPP, it is assumed the SLB2 is extracted from the TRUPACT-III and maintained above ground, and then subsequently placed underground for permanent disposal. In these proposed configurations, the space between the SLB2 and the SWB is always filled by a layer of insulation consisting of air-filled glass microbubbles except for the bottom which rests directly on the SLB2. The thermal scoping calculations described in this report specifically address whether the introduction of external heat inputs, combined with the contributions from the internally generated radiolytic decay heat and chemical reactions, lead to an unstable thermal state during the time of its movement and placement in the permanent disposal location. The external heat inputs are of two forms: 1) ambient thermal irradiation (e.g., solar and ambient storage/disposal temperatures) and 2) accident-induced fire. Three scoping calculation scenarios were derived as representative, conservative scenarios: 1A) TRUPACT-III transient transportation, 1B) SLB2 48-hour outdoor storage with solar radiation, and 2) fully-engulfing fire during SLB2 handling or emplacement following a steady-state analysis in a 38 °C environment. All the simulated scenarios are conservative relative to the operational conditions expected for handling the waste package during transportation and placement in the WIPP underground disposal unit. The predictions obtained from simulating the three exposure scenarios revealed that adding the SLB2 and the air-filled glass microbubbles to the transport and storage/disposal configurations provides additional thermal protection of the drums beyond what the SWB provides alone, both during long-term above ground insolation and underground during a fire accident. Under the current transportation/storage/disposal concepts, the degree of protection provided by the packaging concept is sufficient to prevent the waste from being ignitable. The simulation results demonstrate that there is adequate margin to safely transport and place the RNS waste from WCS to the WIPP under the current operational concept.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method of Attaching Strain Gauges to Various Materials

A method is provided to bond strain gauges to various materials. First, a tape with an adhesive backing is placed across the inside of the fixture frame. The strain gauge is flatly placed against the adhesive backing and coated with a thin, uniform layer of adhesive. The tape is then removed from the fixture frame and placed, strain gauge side down, on the material to be tested. If the material is a high reluctance material, the induction heating source is placed on the tape. If the material is a low reluctance material, a plate with a ferric side and a rubber side is placed, ferric side down, onto the tape. The induction heating source is then placed upon the rubber side. If the material is an insulator material, a ferric plate is placed on the tape. The induction heating source is then placed on the ferric plate. The inductive heating source then generates frequenty from 60 to 70 kilocycles to inductively heat either low reluctance material, ferric side, of ferric plate and provides incidental pressure of approximately five pounds per square inch to the tape for two minutes, thoroughly curing the adhesive. The induction heating source, and, if necessary, the plate or ferric plate, are then removed from the tape after one minute. The tape is then removed from the bonded strain gauge.

Schott, Timothy D.↗

Freeze Tolerant Radiator for an Advanced EMU

During an Extravehicular Activity (EVA), the astronaut s metabolic heat and the heat produced by the Portable Life Support Unit (PLSS) must be rejected. This heat load is currently rejected by a sublimator, which vents up to eight pounds of water each EVA. However, for advanced space missions of the future, water venting to space needs to be minimized because resupply impacts from earth will be prohibitive. If this heat load could be radiated to space from the PLSS, which has enough surface area to radiate most of the heat, the amount of water now vented could be greatly reduced. Unfortunately, a radiator rejects heat at a relatively constant rate, but the astronauts generate a variable heat load depending on how hard they are working. Without a way to vary the heat removal rate, the astronaut would experience cold discomfort or even frostbite. A proven method allowing a radiator to be turned-down is to sequentially allow tubes that carry the heat transfer fluid to the radiator to freeze. A drawback of current freezable radiators using this method is that they are far to heavy for use on a PLSS, because they use heavy construction to prevent the tubes from bursting as they freeze and thaw. This creates the need for a large radiator to reject most of the heat but with a lightweight tube that doesn t burst as it freezes and thaws. The new freezable radiator for the Extravehicular Mobility Unit (EMU) has features to accommodate the expansion of the radiator fluid when it freezes, and still have the high tube to fin conductance needed to minimize the number and weight of the tubes. Radiator fluid candidates are water and a propylene glycol-water mixture. This design maintains all materials within their elastic limits so that large volume changes can be achieved without breaking the tube. This concept couples this elastic expansion with an extremely lightweight, extremely high conductivity carbon fiber fin that can carry the heat needed to thaw a frozen tube. By using most of the exposed surface area of the PLSS as a radiator, the system can reject about 75% of the highest heat load, and reduce the loss of water through sublimation by a factor of four. The proposed radiator and a small water tank can be no heavier than the current system.

Copeland, Robert J.↗

Progress and opportunities in corrosion mitigation in heat transfer fluids for next-generation concentrating solar power

Concentrating solar power (CSP) systems have gained considerable eminence in converting solar thermal energy into electrical power in recent years. According to the U.S. Department of Energy's Gen3 roadmap, the CSP system should operate > 700 °C, as its efficiency depends directly on the operating temperature of the heat transfer fluids (HTFs). A significant challenge, however, is the corrosion of containment materials by the HTFs that is exacerbated at the higher temperatures. A comprehensive review of the high temperature stable HTFs, their properties, corrosion mechanisms on different alloys, and corrosion mitigation measures is of much importance for directing a concerted research and development in the field, which forms the motivation for this compendium. First, molten salt HTFs and their thermophysical properties, along with liquid metals, are introduced. Corrosion of structural materials in different HTFs including molten salts, liquid metals, and supercritical carbon-di-oxide at various temperatures and the corrosion mechanisms are comprehensively reviewed. In addition, several corrosion mitigation methods are discussed. Finally, future directions for HTFs and corrosion mitigation methods in molten salts are proposed. As a result, the holistic review presented here will serve as the foundation for further research addressing relevant challenges and enabling the promise of achieving cost-competitive CSP.

14 SOLAR ENERGY↗

Heat cascading regenerative sorption heat pump

A simple heat cascading regenerative sorption heat pump process with rejected or waste heat from a higher temperature chemisorption circuit (HTCC) powering a lower temperature physisorption circuit (LTPC) which provides a 30% total improvement over simple regenerative physisorption compression heat pumps when ammonia is both the chemisorbate and physisorbate, and a total improvement of 50% or more for LTPC having two pressure stages. The HTCC contains ammonia and a chemisorbent therefor contained in a plurality of canisters, a condenser-evaporator-radiator system, and a heater, operatively connected together. The LTPC contains ammonia and a physisorbent therefor contained in a plurality of compressors, a condenser-evaporator-radiator system, operatively connected together. A closed heat transfer circuit (CHTC) is provided which contains a flowing heat transfer liquid (FHTL) in thermal communication with each canister and each compressor for cascading heat from the HTCC to the LTPC. Heat is regenerated within the LTPC by transferring heat from one compressor to another. In one embodiment the regeneration is performed by another CHTC containing another FHTL in thermal communication with each compressor. In another embodiment the HTCC powers a lower temperature ammonia water absorption circuit (LTAWAC) which contains a generator-absorber system containing the absorbent, and a condenser-evaporator-radiator system, operatively connected together. The absorbent is water or an absorbent aqueous solution. A CHTC is provided which contains a FHTL in thermal communication with the generator for cascading heat from the HTCC to the LTAWAC. Heat is regenerated within the LTAWAC by transferring heat from the generator to the absorber. The chemical composition of the chemisorbent is different than the chemical composition of the physisorbent, and the absorbent. The chemical composition of the FHTL is different than the chemisorbent, the physisorbent, the absorbent, and ammonia.

Jones, Jack A.↗

Analysis and Evaluation of Thermally Annealed Pyrolytic Graphite Heat Spreader for Power Modules

Next generation power modules demand increased heat extraction capability along with reduced weight and volume. In this paper, thermally annealed pyrolytic graphite (TPG) is analyzed and compared with conventional materials used in power modules for thermal management. Fundamental properties of TPG are explained and compared with commonly used materials in power module heat spreaders and substrates. The encapsulated TPG based heat spreader is manufactured and compared with bulk copper in simulation and experimental based analysis. The results show that encapsulated TPG based heat spreader achieves more than 50% reduction in thermal resistance along with 48% reduction in weight in the heat spreader layer.

Gurpinar, Emre↗

Evaluation of ceria as a surrogate material for UO 2 in experiments on fuel cracking driven by resistive heating

A variety of normal operation and accident scenarios can generate thermal stresses large enough to cause cracking in light-water reactor (LWR) fuel pellets. Cracking of fuel pellets can lead to reduced heat removal, larger centerline temperatures, and localized stress in cladding all of which impact fuel performance. Furthermore, pellet cracking also contributes to a temperature reduction in the pellet since the pellet fragments tend to move towards the heat sink (cladding), and the heat flow remains predominantly radial despite the presence of cracks. It is important to understand the temperature profile on the pellet before and after cracking to improve cracking models in fuel performance codes However, in-reactor observation and measurement of cracking is very challenging owing to the harsh environment and design of fuel rods. Recently, an experimental pellet cracking test stand was developed for separate effects testing of normal operations and accident temperature conditions, using thermal imaging to capture the pellet surface temperature for evaluation of thermal stresses and optical imaging to capture the evolution of cracking in real time. Cracking experiments were initially performed using ceria (CeO 2 ) as a surrogate fuel material, which is useful for developing and demonstrating the experimental approaches but is also valuable in its own right for cracking model development and validation. A combination of induction and resistance heating was used for volumetric heat generation in the pellet creating a thermal gradient. The material properties of CeO 2 and UO 2 are reviewed and compared for use in model development. Simulations of the experiment were performed to evaluate the behavior of the surrogate (CeO 2 ) fuel in BISON. The measured temperature profiles from BISON models match reasonably well with the observed experiments for the ceria pellets before cracking. The findings from this work will help improve confidence in fracture models used for fuel pellets under similar in-reactor conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Making coal relevant for small scale applications: Modular gasification for syngas/engine CHP applications in challenging environments

Small-scale coal gasification technology, coupled to a reciprocating engine generator, has the potential for making coal a cost competitive resource for meeting the flexible energy needs and resiliency requirements of utilities across the United States. To maintain grid stability and reliability, electrical generation must be regulated to match the load at the proper voltage and frequency. With the expansion of intermittent sources into the grid, such as wind and solar, frequency and voltage regulation become increasingly important and challenging. This work presents the results of a Front End Engineering Design (FEED) effort to detail the engineering and preliminary economics of a small-scale, air blown, fixed-bed gasification process, operating at near-atmospheric pressure, with gas cleanup to provide syngas and pyrolysis liquid fuels for use in reciprocating engine generators for combined heat and power at the University of Alaska Fairbanks. A very detailed assessment of capital and operating costs allows the evaluation of a levelized cost of electricity of 208.06 $/MWh, which can be reduced through the selling of by-products (steam for heating purposes and pyrolysis liquids to be used for power generation in an existing diesel engine). Here, a combined sensitivity analysis, based on the Monte Carlo approach, has been carried out to evaluate the effects of the uncertainties (capital and operating costs and plant annual availability) on the LCOE.

01 COAL, LIGNITE, AND PEAT↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

Development of IR radiation simulator for spacecraft thermal testing

The aim was to simulate, in a ground test, the solar radiation environment to which the Ofeq satellite would be exposed in orbit. The solar simulator usually used is very expensive, as are its operation and maintenance, therefore an infrared (IR) simulator was used; its development involved the creation of uniform IR fluxes onto the irregular geometry of a spacecraft. The tests were carried out on a thermal model of the satellite and the model was verified in a solar simulator test at a European space center. Heat flux mapping software was developed to plan the positioning of the heating elements which generated the IR fluxes and a system was built for heat flux and temperature monitoring and control. A special heat flux sensor was developed to measure the energy absorbed by the satellite surfaces; its calibration had to be independent of wavelength, so that the measurements obtained at IR wavelengths would be equivalent to the actual solar radiation effects. The results of the verification experiment are presented; their conformity with predicted values indicates that the technique developed is a suitable tool for satellite design verification.

Shimrony, Yoram↗