Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Building-Wide, Adaptive Energy Management Systems for High-Performance Buildings: Final CRADA Report

Development and field demonstration of the minimum ratio policy for occupancy-driven, predictive control of outdoor air ventilation. Technology transfer of Argonne’s methods for occupancy estimation and forecasting and for M&V to BuildingIQ for their deployment. Selection of CO2 sensing as the currently best-available technology for occupancy-driven controls. Accelerated restart capability for the commercial BuildingIQ system using horizon shifting strategies applied to receding horizon optimal control problems. Empirical-based evidence of 30% chilled water energy savings and 22% total HVAC energy savings achievable with the BuildingIQ system operating in the APS Office Building on-site at Argonne.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Report for Project titled High Thermal Conductivity Polymer Composites for Low-Cost Heat Exchangers

Heat exchangers (HXs) are critical components in a wide range of heat transfer applications, from HVAC (Heating Ventilation and Cooling) to automobiles to manufacturing plants. They require materials capable of transferring heat at high rates while also minimizing thermal expansion over the usage temperature range. Conventionally, metals are used for applications where effective and efficient heat exchange is required, since many metals exhibit thermal conductivity over 100 W/m K. While metal HXs are constantly being improved, they still have some inherent drawbacks due to their metal construction, in particular corrosion. Polymeric material can offer solution to such durability issues and allow designs that cannot be afforded by metal construction either due to complexity or cost. A major drawback of polymeric material is their low thermal conductivity (0.1-0.5? W/mK) that would lead to large system size. Recent improvements in the area of filled polymers have highlighted the possibility to greatly improve the thermal conductivity of polymeric materials while retaining their inherent manufacturing advantage, and have been applied to heat sink applications. Therefore, the objective of this project was to develop a robust review of materials for the manufacturing of industrial and commercial non-metallic heat exchangers. This review consisted of material identification, literature evaluation, as well as empirical and model characterization, resulting in a database of relevant material properties and characteristics to provide guidance for future heat exchanger development.

36 MATERIALS SCIENCE↗

Solar Living House Final Technical Report

The Solar Living House is a high-performance solar-powered dwelling designed by a team of faculty and students from the University of Florida, in collaboration with Santa Fe College, the National University of Singapore, and Alachua Habitat for Humanity. The project was designed in accordance with the Solar Decathlon 2015, a research, design, education, and outreach program developed by the U.S. Department of Energy (DOE). The Solar Living House is fundamentally a house for living, centered on people and the activities of daily life while quietly introducing advanced design, construction, and engineering technologies. The 993 square-foot two-bedroom one-bath home was designed to embrace and frame an exterior courtyard space. This courtyard acts as an extension of the interior living spaces, maximizing the spatial potentials of a modest building footprint and introducing natural light into the primary living spaces of the house. Research Outcomes: The Solar Living House advances work on high-performance buildings through three principal technological innovations: wet/dry modular construction, a building automation system, and solar dehumidification systems. Wet / Dry Modular Construction: The house is designed as a series of five modules, including one that is designated as the “wet core.” The wet core consolidates the mechanical systems and bathroom into a single module to reduce plumbing runs, efficiency losses, and on-site construction time. The other four modules are designed to eliminate interior load bearing walls to allow for maximum flexibility in the reconfiguring of the space over time. The modules are designed to meet the structural challenges of both Florida’s hurricanes and California’s earthquakes. Building Automation System: The house is equipped with an integrated building automation system, allowing the houses environmental systems, lights, security systems, and smoke detectors to be programmed, monitored, and controlled through any mobile or computing device. These systems allow for more precise calibrations of temperature/humidity/lighting to correspond with user needs and preferences, minimizing energy losses with economical night- or day-time setbacks. Solar Dehumidification System: The most significant technological innovation in the Solar Living House is the solar thermal dehumidification system. This system generates hot water through two rooftop-mounted evacuated tube solar thermal collectors. The hot water is used to continually dry a regenerative solid desiccant material, typically white silica gel. The solid desiccant is used to adsorb moisture and humidity from the air without additional mechanical cooling. This strategy allows humidity to be modulated independently of air temperature, providing greater thermal comfort and reducing the opportunity for the growth of mold spores within the house while also reducing the overall energy consumption of the HVAC system. Economic Feasibility: The team set aggressive goals for affordability, targeting a construction cost of $138,710. An independent professional cost estimator determined the overall project costs, as designed, would be $333,799, or $336.15 per square foot of finished floor area. This is more than 2.4 times the target construction cost. By comparison, the average construction cost for a home in the United States in 2015 was $289,415, or $103.29 per square foot of finished floor area. Following work on the Solar Living House, team leaders incorporated many of its objectives into a net-zero energy home on a site in Gainesville, Florida. This site-built home avoided many of the constraints and complications of modular construction necessitated by the Solar Decathlon, allowing it to be built for a much more modest budget. This two-bedroom two bath 1,800 square foot home was constructed for $135.39 per square foot, including active photovoltaic solar systems, careful attention to continuous air barriers, increased insulation levels, and permanent site constructions. This project suggest that high-performance buildings can be realized for more modest budgets. Public Benefits: Work on the Solar Living House and Solar Decathlon 2015 offered our student team unparalleled learning opportunities. Because of the duration of the project, a number of students participated at different points in their education, from first year undergraduates all the way through to advanced graduate students. The opportunity for collaboration with students and faculty from the National University of Singapore was also extraordinary, allowing for a sharing of technical knowledge and cultural exchange. The wider public has benefited from this work as its findings have been shared through public presentations and publications. It serves as a useful stepping stone along the path towards affordable, high-performance buildings.

14 SOLAR ENERGY↗

Using EMIS to Identify Top Opportunities for Commercial Building Efficiency

Energy Management and Information Systems (EMIS) comprise a broad family of tools and services to manage commercial building energy use. These technologies offer a mix of capabilities to store, display, and analyze energy use and system data, and in some cases, provide control. EMIS technologies enable 10–20 percent site energy savings in best practice implementations. Energy Information System (EIS) and Fault Detection and Diagnosis (FDD) systems are two key technologies in the EMIS family. Energy Information Systems are broadly defined as the web-based software, data acquisition hardware, and communication systems used to analyze and display building energy performance. At a minimum, an EIS provides daily, hourly or sub-hourly interval meter data at the whole-building level, with graphical and analytical capability. Fault Detection and Diagnosis systems automatically identify heating, ventilation, and air-conditioning (HVAC) system or equipment-level performances issues, and in some cases are able to isolate the root causes of the problem. They use computer algorithms to continuously analyze system-level operational data to detect faults and diagnose their causes. Many FDD tools integrate the trend log data from a Building Automation System (BAS) but otherwise are stand-alone software packages; other types of FDD tools are implemented as “on-board” equipment-embedded diagnostics. (This document focuses on the former.) Analysis approaches adopted in FDD technologies span a variety of techniques from rule-based methods to process history-based approaches. FDD tools automate investigations that can be conducted via manual data inspection by someone with expert knowledge, thereby expanding accessibility and breath of analysis opportunity, and also reducing complexity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Variable Refrigerant Flow Systems Performance on Oak Ridge National Laboratory s Flexible Research Platform: Part 1 Cooling Season Analysis

This report provides second-year cooling season test results for the multi-year project titled “Evaluation of Variable Refrigeration Flow (VRF) System on Oak Ridge National Laboratory (ORNL)’s Flexible Research Platform (FRP).” The purpose of the second-year project was to (1) evaluate the full- and partload performance of VRF systems compared with an existing baseline heating, ventilation, and airconditioning (HVAC) system, which is a conventional rooftop unit (RTU) variable-air-volume (VAV) system with electric resistance heating and (2) use hourly building energy simulation to evaluate the energy savings potential of using VRF systems in major US cities. The second-year project performance period was from July 2015 through June 2016.

47 OTHER INSTRUMENTATION↗

Evaluation of Variable Refrigerant Flow Systems Performance on Oak Ridge National Laboratory s Flexible Research Platform: Part 2 Heating Season Analysis

The performance of two HVAC systems was evaluated using ORNL’s FRP, which is a two-story, 3,200 ft2 (297.3 m2) multi-zone unoccupied building that represents a typical low-rise, small office building common in the US existing building stock. The FRP is equipped with a conventional 12.5 ton (44 kW) RTU-VAV reheat system as the baseline system. For this study, a 12 ton (42 kW) VRF with a dedicated outdoor air system (DOAS) was installed to be compared with the baseline RTU system.

47 OTHER INSTRUMENTATION↗

Keys to the House: Unlocking Residential Savings With Program Models for Home Energy Upgrades

After more than 40 years of effort, energy efficiency program administrators and associated contractors still find it challenging to penetrate the home retrofit market, especially at levels commensurate with state and federal goals for energy savings and emissions reductions. Residential retrofit programs further have not coalesced around a reliably successful model. They still vary in design, implementation and performance, and they remain among the more difficult and costly options for acquiring savings in the residential sector. If programs are to contribute fully to meeting resource and policy objectives, administrators need to understand what program elements are key to acquiring residential savings as cost effectively as possible. To that end, the U.S. Department of Energy (DOE) sponsored a comprehensive review and analysis of home energy upgrade programs with proven track records, focusing on those with robustly verified savings and constituting good examples for replication. The study team reviewed evaluations for the period 2010 to 2014 for 134 programs that are funded by customers of investor-owned utilities. All are programs that promote multi-measure retrofits or major system upgrades. We paid particular attention to useful design and implementation features, costs, and savings for nearly 30 programs with rigorous evaluations of performance. This meta-analysis describes program models and implementation strategies for (1) direct install retrofits; (2) heating, ventilating and air-conditioning (HVAC) replacement and early retirement; and (3) comprehensive, whole-home retrofits. We analyze costs and impacts of these program models, in terms of both energy savings and emissions avoided. These program models can be useful guides as states consider expanding their strategies for acquiring energy savings as a resource and for emissions reductions. We also discuss the challenges of using evaluations to create program models that can be confidently applied in multiple jurisdictions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chapter 16: Retrocommissioning Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

Retrocommissioning (RCx) is a systematic process for optimizing energy performance in existing buildings. It specifically focuses on improving the control of energy-using equipment (e.g., heating, ventilation, and air conditioning [HVAC] equipment and lighting) and typically does not involve equipment replacement. Field results have shown proper RCx can achieve energy savings ranging from 5 percent to 20 percent, with a typical payback of two years or less (Thorne 2003). The method presented in this protocol provides direction regarding: (1) how to account for each measure's specific characteristics and (2) how to choose the most appropriate savings verification approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing the Performance and Dynamic Control of Energy-Efficient Cellular Shades in the PNNL Lab Homes

This report describes the experimental design and results of testing the energy performance of Hunter Douglas double-cell cellular shades under various control schemes in the Pacific Northwest National Laboratory’s (PNNL) Lab Homes. The results of both heating and cooling season experiments are presented, where testing is designed to assess the heating, ventilation, and air conditioning (HVAC) savings resulting from the thermal insulating properties as well as the automated and dynamic control strategies of shading devices. Control schemes tested include common “connected home” strategies where controls are integrated and coordinated between the window shading device, building thermostats, and external sensors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stasis PCM Test Results

A phase change material product distributed by Stasis Group, designed to reduce the cooling energy requirements of multi-story commercial buildings, was tested in a side-by-side comparison at FLEXLAB® (LBNL, 2018), a calibrated test facility for low energy building technology solutions. The product was installed according to Stasis recommendations in the ceiling plenum of a 600 ft 2 cell representative of an office space, while an identical cell was operated in the same conditions, except for the night-time pre-cooling sequence and without the product, to gather baseline data. The cells were operated to replicate summer conditions of a candidate office building for retrofit. For the tests conducted at FLEXLAB, two Phase Change Material (PCM) compositions were tested, with the second product having an upgraded composition for thermal performance and upgraded packaging that was used to meet with fire safety requirements for a plenum application. Two rounds of tests were performed, which were designed to collect data for both core (designated as Round 1) and perimeter (Round 2) office space conditions. Following the analysis of the data collected during Round 1, the experimental design was modified to better represent the thermal conditions of a typical office space in relation to the PCM performance. A new product was also brought in for testing in Round 2, which had an improved operational temperature range and packaging properties. In Round 1, multiple tests were conducted to evaluate the performance of the product under different conditions of internal loads, temperature setpoints, pre-cooling strategies and temperature control strategies. In Round 2, the internal conditions were kept constant, while the test conditions only differ in the amount of PCM installed in the test cell plenum and the length of the nighttime pre-cooling sequence. The performance benefits of PCM are generally two-fold: the material may reduce peak cooling energy use during daytime hours (a peak demand energy use benefit) and may allow for energy savings with pre-cooling at night through night flush HVAC controls when night time outside air temperatures are lower, and fan energy use for cooling is more efficient than the use of daytime compressor-based cooling. The focus of this research project was mainly on quantifying the energy savings potential of the latter case although some effects on peak reduction were noted. Between the cell with PCM and nighttime precooling and the reference cell without PCM or precooling, a reduction in cooling load during occupied hours was noted between 7.6 kWh (or 22% of occupied hours cooling load) and 12.5 kWh (or 33% of occupied pg. 7 hours cooling load). Future work can further evaluate the peak cooling load reduction benefits of this product in more detail. This report highlights the results of Round 2, which reflect the performance of the modified PCM product when operated in suitable conditions. The results of Round 1, along with an analysis of the experimental data to identify the factors that prevented the product from performing as desired are presented in Appendix B.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochromic Window Demonstration at the John E. Moss Federal Building, 650 Capitol Mall, Sacramento, California

Dynamic windows have the potential to provide real-time optimization of perimeter zone energy use, peak demand, comfort, amenity, and cost criteria on a seasonal or even minute-to- minute basis in response to weather, occupant or regional grid demands. Electrochromic (EC) windows, a type of dynamic window, have the ability to adjust their tint dynamically in response to a small applied voltage. In previous studies, they have shown potential to reduce heating, ventilation and air conditioning (HVAC) energy consumption and increase occupant satisfaction. This technology is available in the U.S. as a commercial product from multiple vendors with high-capacity manufacturing facilities, and could be broadly deployed if successful in a pilot test. This Green Proving Ground (GPG) program study examines the energy and comfort performance of EC windows in south-facing perimeter zones of a typical U.S. General Services Administration GSA office building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

State-of-the-Art Analysis of Nearly Zero Energy Buildings

The IEA HPT Annex 49 "Design and integration of heat pumps for Nearly Zero Energy Buildings" deals with the design and integration of heat pumps as core component of the HVAC system for Nearly or Net Zero energy buildings (NZEB).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BuildingIQ Technology Field Validation

This document describes a field validation and verification of the BuildingIQ Predictive Energy Optimization (PEO) technology based on a five-site study. BuildingIQ describes its PEO technology as a software-as-a-service (SaaS) platform that optimizes commercial building HVAC control for system efficiency, occupant comfort, and cost. It is targeted for use in large, complex buildings, and integrates with the building automation system (BAS) to conduct supervisory control. The PEO algorithm defines optimal space air temperature setpoints that are automatically implemented at the variable air volume (VAV) terminal units when possible, or through supply air temperature and duct static pressure setpoints at the air handling unit (AHU) level. The optimization is built upon a learned predictive model that provides a 24-hour ahead forecast of the building’s power profile, using weather forecasts and historical operational data; this model is updated every 4 to 6 hours. Demand-responsive load reductions may also be implemented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrochromic Window Demonstration at the 911 Federal Building, 911 Northeast 11th Avenue, Portland, Oregon

Switchable electrochromic (EC) windows are part of a new class of dynamic, energy-efficient technologies that enable real-time, active load management in response to weather conditions and the unique operating conditions of individual buildings. Owners can now specify a solid-state technology that reacts to various stimuli like the skin of a living entity. The technology can be controlled to address multiple criteria to achieve a more optimal energy-efficient and comfortable indoor environment than one with static or manually operated technologies. Inputs can include data on outdoor solar conditions, utility rates, occupancy status, heating, ventilation, and air conditioning (HVAC), or operating emergency or security mode. The outputs then dictate how the EC window is controlled, whether as a self-contained autonomous unit that achieves specific zonal objectives or as a part of an integrated system designed to address whole building, campus and grid-related goals. Since windows typically have a 30-year life, these dynamic qualities enable the building to be adaptable and more resilient as the environmental, operating and economic context evolves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

VOLTTRON-enabled Home Energy Management System

Home Energy Management Systems (HEMS) consist of software and hardware systems that provide communication, control, and management among different electronic devices, such as heating, ventilation, and air-conditioning (HVAC) systems. HEMS are a growing market sector in the era of smart grids and smart homes. HEMS can help both homeowners and utilities save money and energy by monitoring and controlling smart devices in a house. Based on the Department of Energy (DOE) Building Energy Data Book, 41% of the energy consumed in the United States is used by buildings (see Figure 1). This shows the importance of saving energy in the building sector. This report introduces two approaches that existing HEMS vendors can use to leverage VOLTTRON as their control and interoperability engine. The goal of this project is to make open-source, user-friendly HEMS available to the market so that everyone can benefit from them. The HEMS introduced as a result of this study should satisfy HEMS specifications such as device monitoring and control, seamless communication between devices, DR, intelligence, data management, and security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pascua Yaqui Tribe Energy Audit (Final Report)

The Pascua Yaqui Tribe has the goal of reducing energy use and costs in its government facilities and housing. In a proactive effort to meet the Tribe's needs an energy audit was performed to accomplish the following goals: Develop an energy efficiency implementation strategy. Prepare an energy audit to identify cost-effective energy efficiency opportunities. Plan and conduct a level II energy audit in tribal government buildings and tribal housing. The audit encompassed four tribal government buildings and a group of residential structures. The purpose of this project was to assess the various facilities energy use in order to inform a means to lower annual consumption. An evaluation of each facility's historical energy and major energy-consuming equipment was performed, and energy conservation measures (ECM's) were identified. An average of 4 ECM's where recommended for each facility. If each facility's recommended ECM's are implemented, the average calculated yearly benefits to the government and residential buildings would result in a 48.3% reduction in electrical energy/costs savings and a 14.4% reduction in natural gas energy/costs savings. Recommended projects for implementation include: Interior Lighting Upgrade, Exterior Lighting Upgrade, Solar Pool Covers, Retro-Commissioning, Low Volt Fixtures, Plug Load Management System, Occupancy Sensor Control, and Solar PV for government/casino buildings and appliance, window, HVAC, Weather Stripping, and water heaters replacement in residences.

03 NATURAL GAS↗

ALDCP Student Team 7/25/19 Briefing [Slides]

This set of slides documents the activities of the Associate Laboratory Directorate for Capital Projects (ALDCP) student team during the week of July 25, 2019. It summarizes the involvement of the group in the Smart Lab project, and the individual progress of separate projects, including the Life-Cycle Cost Analysis (LCCA) Calculator and Tests, the HVAC Renovation, and the Renovation Feasibility Study, with accomplishments and barriers for each.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Incentive-Based Control and Coordination of Distributed Energy Resources

Higher penetration of renewable generation will increase the demand for adequate (and cost-effective) controllable resources on the grid that can mitigate and contain contingencies locally before they cause a network-wide collapse. This report details a scalable hierarchical control strategy for coordinating a vast number of heterogeneous distributed energy resources (DERs) in order to provide three ancillary grid services: frequency response, regulation, and ramping reserve. The control architecture consists of 1) a Distribution Reliability Coordinator (DRC), which allocates resource responses based on their declared flexibility, 2) aggregator controllers, which control a collection of DERs, and finally, 3) DER controllers at the individual devices. Test results are provided showing scalable performance on thousands of simulated residential DERs (air conditioners and water heaters) as well as results of a hardware-in-the-loop demonstration of commercial HVAC and microgrid equipment providing real responses in coordination with a grid simulation. Technology commercialization barriers and strategy is also discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗