Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Chapter 3: Commercial and Industrial Lighting Controls Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

This Commercial and Industrial Lighting Controls Evaluation Protocol (the protocol) describes methods to account for energy savings resulting from programmatic installation of lighting control equipment in large populations of commercial, industrial, government, institutional, and other nonresidential facilities. This protocol does not address savings resulting from changes in codes and standards, or from education and training activities. When lighting controls are installed in conjunction with a lighting retrofit project, the lighting control savings must be calculated parametrically with the lighting retrofit project so savings are not double counted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy efficient fluid powered linear actuator with variable area and concentric chambers

Hydraulic actuation systems having concentric chambers, variable displacements and energy recovery capabilities include cylinders with pistons disposed inside of barrels. When operating in energy consuming modes, high speed valves pressurize extension chambers or retraction chambers to provide enough force to meet or counteract an opposite load force. When operating in energy recovery modes, high speed valves return a working fluid from extension chambers or retraction chambers, which are pressurized by a load, to an accumulator for later use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving the energy efficiency of room air conditioners in China: Costs and benefits

China is the world's largest consumer of room air conditioners, and it contributes about a quarter of global space cooling CO 2 emissions. We model the costs and benefits of recently proposed new room air conditioner minimum energy performance standards (MEPS) in China. Our results suggest that newly proposed MEPS brings accumulative CO 2 emissions reductions of 12.8% between 2019 and 2050, and accumulative bill saving of 2620 billion RMB to China's consumers. The benefits of the proposed MEPS decrease with longer MEPS revision intervals and increase with shorter intervals—indicating that the intervals should be balanced to maximize benefits while accommodating constraints due to air conditioner manufacturer design cycles. We also model potential nationwide benefits from higher MEPS. Across two increasingly aggressive MEPS scenarios, China's room air conditioner electricity consumption and CO 2 emissions in 2050 are both reduced by 15–53% compared to the proposed MEPS. The highest-efficiency scenario (reaching MEPS of annual performance factor 5.4 in 2025) provides the largest long-term national benefits. These results could inform development of a Chinese regulatory regime that effectively updates room air conditioner MEPS. Because China is the world's largest manufacturer of room air conditioners, the economic, energy, and emissions benefits resulting from higher Chinese MEPS could also have a global reach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Round Trip Energy Efficiency of NASA Glenn Regenerative Fuel Cell System

NASA Glenn Research Center (GRC) has recently demonstrated a Polymer Electrolyte Membrane (PEM) based hydrogen/oxygen regenerative fuel cell system (RFCS) that operated for a charge/discharge cycle with round trip efficiency (RTE) greater than 50 percent. The regenerative fuel cell system (RFCS) demonstrated closed loop energy storage over a pressure range of 90 to 190 psig. In charge mode, a constant electrical power profile of 7.1 kWe was absorbed by the RFCS and stored as pressurized hydrogen and oxygen gas. In discharge mode, the system delivered 3 to 4 kWe of electrical power along with product water. Fuel cell and electrolyzer power profiles and polarization performance are documented in this paper. Individual cell performance and the variation of cell voltages within the electrochemical stacks are also reported. Fuel cell efficiency, electrolyzer efficiency, and the system RTE were calculated from the test data and are included below.

Garcia, Christopher P.↗

Towards Finding Energy Efficient Paths for Hybrid Airships in the Atmosphere of Venus

This paper presents a solution to the motion planning problem for an autonomous airship under superrotation winds of the Venusian atmosphere. The airship uses both buoyancy and aerodynamic lift to control its altitude. In addition, solar panels distributed over the aircraft provide energy to the propellers and allow for battery recharging. Our approach uses a sampling-based planner that relies on Dubins’ Airplane paths deformed under the influence of the winds to create a tree of kinematically feasible trajectories. We use the battery state to prune energetically unfeasible trajectories and we propose a cost function that accounts for the energy expenditure of the propulsive system and that considers battery charging by using the Economics notion of opportunity cost. The method is illustrated through a series of simulations that show how the vehicle takes longer and high-altitude paths to minimize the use of energy and favor battery recharge. Our results also show that naive trajectories are not feasible in terms of energy, justifying the need for more efficient solutions.

Bernardo Martinez R. Jr↗

Cost-Benefit Analysis for Energy Efficient Refrigerators and Freezers in Uganda

Refrigeration appliances and equipment available on the market are manufactured with a wide range of energy performance. The goal of this report is to perform a cost-benefit analysis, providing policy recommendations to develop standards and labels for refrigerators in Uganda: in particular, an analysis of the cost-effectiveness of adopting the UNEP U4E MRG for refrigerators given the local context in Uganda.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retro-Commissioning Sensor Suitcase for Energy Efficiency

This project will enable Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) to work with industry partner, GreenPath Energy Solutions, joint developers of the Suitcase, to enhance the capabilities and usability of the Retro-Commissioning Sensor Suitcase (hereinafter the Sensor Suitcase or Suitcase), assisting GreenPath to take the Suitcase to market and rapidly expand their market share. The proposed project will specifically focus on 1) adding sensors types to extend the data collection capability and support more building and equipment performance metrics and identification of even more energy saving opportunities, 2) developing algorithms to identify recommendations for the new energy savings opportunities from item 1 and to prototype software modifications implementing them, 3) validating the use of vibration sensors to detect the operating state of a broader set of packaged HVAC equipment (additional capacities, different numbers of stages, etc.) than tested in initial development and modifying the state algorithm and software code, as needed, 4) improving cost-effectiveness in manufacturing the Sensor Suitcase, and 5) additional field testing of the technology in real buildings to more comprehensively validate Suitcase performance and to guide refinement of its capabilities. Project results will position GreenPath, and potential future licensees, to implement the new capabilities developed in this project in GreenPath’s RCx Building Suitcase, increasing its functionality and the savings resulting from its use. These enhancements will increase the value of the Suitcase to users and increase the potential market for its use and impacts in that impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FEMP Energy Efficiency and Indoor Environmental Quality Assessment Guide

The purpose of this document is to provide a thorough guidance when preparing for an energy and indoor environmental quality (IEQ) assessment. It provides step-by-step instructions, detailed insights, and practical examples for the various phases of an energy and IEQ assessment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Requirements for Acquisition Professionals

Federal agencies are required to purchase products as certified by EPA or designated by DOE’s Federal Energy Management Program (FEMP). The two programs cover different products, sizes and applications. These requirements also have an associated FAR clause, FAR 52.223-15. They apply to both energy-consuming products and services that use energy-consuming products.

Ackerman, Allison↗

Consumer Guide to Energy-Efficient Windows

Learn how ENERGYSTAR-qualified windows can improve indoor comfort while saving money on heating and cooling costs. This fact sheet from Energy Saver includes information on ENERGY STAR standards for windows, replacing old windows, and considerations when purchasing windows.

windows, Energy Saver↗

Opportunity Assessment for U.S. Industry: Energy-Efficient Cooling Technologies in Mexico

Mexico's rapidly expanding room air conditioner (AC) market presents a strategic opportunity for U.S. manufacturers to strengthen North American supply chains while addressing critical energy infrastructure challenges. With demand for room AC units in residential and commercial buildings projected to drive a 26 GW increase in Mexico’s peak electrical load by 2050, high-efficiency air conditioning systems offer both substantial market opportunities and essential grid stability benefits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Energy Efficiency by Developing Components for Distributed Cooling and Heating Based on Thermal Comfort Modeling (General Motors LLC Final Project Report)

On November 3, 2009, General Motors (GM) accepted U.S. Department of Energy (DOE) Cooperative Agreement award number DE-EE0000014 from the National Energy Technology Laboratory (NETL). GM was selected to execute a three-year cost shared research and development project on Solid State Energy Conversion for Vehicular Heating, Ventilation & Air Conditioning (HVAC) and for Waste Heat Recovery. The primary objective of this project was to develop a distributed automotive HVAC system that provides thermal comfort equivalent to current state-of-the-art centralized systems while using significantly less energy. To satisfy this objective, the team identified the following goals: • Reduce by at least 30% of the “billions of gallons” the fuel used in cooling mode to maintain occupant comfort through the localized use of thermoelectric (TE) technology while maintaining occupant comfort and safety. • Develop TE HVAC components with a coefficient of performance (COP) greater than 1.3 for cooling and greater than 2.3 for heating, then integrate and test these components as part of a reliable distributed HVAC system in a conventional vehicle (an eAssist Buick Lacrosse) and an extended range electric vehicle (a Chevrolet Volt). • Update the UCB Thermal Comfort model to predict the response of vehicle occupants to localized heating and cooling based on human subject testing, and develop associated computer-aided engineering (CAE) tools to support the integration of distributed HVAC components into future vehicle designs. A secondary objective of the project was to improve the efficiency of thermoelectric generators for converting engine waste heat into electricity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy-Efficient Adaptive Cruise Control Using Eco-Driving Algorithm

SwRI Eco-Driving Algorithm – Objectives and Method – Required Information Streams and Velocity Profile Realization ▪ Impact on Energy Consumption – Study 1 – NEXTCAR II • Individual (ego/eco) vehicle on Blanco Road, San Antonio, TX – Study 2 – DOE EEMS • Entire Urban Corridor – N High Street, Columbus, OH

Bhagdikar, Piyush↗

Chicago Energy Efficiency Planning and Analysis and Integrated Retrofit Strategy Validation in Single-Family Homes

In June 2020, the project team comprised of Elevate and the National Renewable Energy Laboratory (NREL), with advisory roles from the City of Chicago and Commonwealth Edison, initiated a three-year project with the U.S. Department of Energy to inform communitywide energy planning at a local scale and validate advanced retrofit packages that achieve at least 50% energy savings in existing homes. The project team has characterized Chicago’s single-family and 2-4 unit housing stock and energy use using the ResStock™ modeling tool, and with that information developed advanced whole home energy retrofit packages for single family and 2-4 unit homes that can reduce energy use by at least 50% and support climate, air quality, and other goals. This report presents an analysis of the technical potential of applying these retrofit packages at a City-wide scale, and a roadmap for rapidly scaling up retrofit programs to improve Chicago’s housing stock and target investments in the neighborhoods that need it most. The main goals of the analysis are to: 1) develop a Chicago-specific single-family and 2-4 unit building retrofit prioritization strategy; 2) identify opportunities for beneficial electrification in communities and home types that stand to benefit most; and 3) assess costs and savings potential for retrofit investments at a household and city scale, in terms of energy use, bill impacts, carbon emissions, and other outcomes.

14 SOLAR ENERGY↗

Revitalizing Canton City Schools: A Sustainable and Cost-Effective Energy Efficiency Plan

The primary objective of this project was to focus on conducting the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Level 2 Energy Audits of all the schools/school facilities in the portfolio, and on developing a comprehensive Strategic Plan for implementing energy improvements. The overall aim of budget period 1 (BP1) was to implement Energy Audits and the Strategic Plan to provide a clear pathway to prioritize energy improvements as well as allow the district to access private sector funding (if needed) and/or tax credits and realize high-impact health and safety benefits for Budget Period 2.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗