Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy Systems Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Engineering model system study for a regenerative fuel cell: Study report

Key design issues of the regenerative fuel cell system concept were studied and a design definition of an alkaline electrolyte based engineering model system or low Earth orbit missions was completed. Definition of key design issues for a regenerative fuel cell system include gaseous reactant storage, shared heat exchangers and high pressure pumps. A power flow diagram for the 75 kW initial space station and the impact of different regenerative fuel cell modular sizes on the total 5 year to orbit weight and volume are determined. System characteristics, an isometric drawing, component sizes and mass and energy balances are determined for the 10 kW engineering model system. An open loop regenerative fuel cell concept is considered for integration of the energy storage system with the life support system of the space station. Technical problems and their solutions, pacing technologies and required developments and demonstrations for the regenerative fuel cell system are defined.

Chang, B. J.↗

Accelerating progress toward operational excellence of fossil energy plants with CO2 capture

To address challenges in attaining operational excellence for clean energy plants, the National Energy Technology Laboratory has launched a world-class facility for Advanced Virtual Energy Simulation Training And Research (AVESTARTM). The AVESTAR Center brings together state-of-the-art, real-time, high-fidelity dynamic simulators with operator training systems and 3D virtual immersive training systems into an integrated energy plant and control room environment. This paper will highlight the AVESTAR Center simulators, facilities, and comprehensive training, education, and research programs focused on the operation and control of an integrated gasification combined cycle power plant (IGCC) with carbon dioxide capture.

97 MATHEMATICS AND COMPUTING↗

Advancing Construction through the Buildings Workforce: Preprint

Buildings are America's energy hogs, consuming over 70 percent of all electricity and over 50 percent of all natural gas produced across the country. Achieving a clean energy future requires us to reinvent how buildings manage energy resources and how consumers demand it. The U.S. Department of Energy is investing in a range of technological advancements that are paving the way to a future where buildings are no longer simply energy consumers, but rather are part of an integrated system that help manage energy resources in a way that supports the electricity grid. This paradigm shift presents an opportunity to increase the efficiency of the built environment, but will only be realized if we build a knowledgeable workforce to design, construct, and operate these high-performance buildings in step with the rate of technological advancement.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Integrated Design of a Robust System for Inertial Fusion Energy

For inertial fusion energy (IFE) to be successful, designs need to work robustly including both target physics and engineering considerations. For a power plant to be reliable and have a high operating capacity factor, the integrated design of the target, driver, target fabrication, target injection system, and chamber all need to work together in way that is robust and repeatable to expected variations. One of the lesson’s learned from our experience at NIF is that designs that are sensitive have not performed as expected – even in single shot mode. The lesson’s learned from NIF should be folded into creating integrated designs for IFE and for evaluating the tradeoffs between the different parts of the IFE system. To do so, we propose using the NIF 1.3 MJ yield shot/design (N210808) as a starting point of a study of the feasibility of indirect drive designs for IFE. If the hohlraum inefficiency precludes indirect drive, the study would include direct drive or fast ignition versions of this design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cost and Performance Baseline for Fossil Energy Plants - Volume 3: Low Rank Coal and Natural Gas to Electricity

The Cost and Performance Baseline for Fossil Energy Plants - Volume 3: Low Rank Coal and Natural Gas to Electricity contains three separate reports including 28 cases: integrated gasification combined cycle plants (Volume 3a), combustion plants (Volume 3b), and natural gas combined cycle plants (Volume 3c). This study establishes performance and cost data for fossil energy power systems, specifically integrated gasification combined cycle (IGCC), combustion, and natural gas combined cycle (NGCC) plants all with and without carbon capture and sequestration. Most of the coal fired plants are studied using both Rosebud Montana Powder River Basin Coal (PRB) at a Montana site at an elevation of 3,400 feet and North Dakota Lignite (NDL) at a mine-mouth North Dakota site at an elevation of 1,900 feet. NGCC plants are also studied at both locations. The analyses were performed on a consistent technical and economic basis that accurately reflects current market conditions for coal-fueled plants

01 COAL, LIGNITE, AND PEAT↗

CloudZero Phase 2 Technical Report

Expand upon the successful Phase 1 net zero cloud test proof of concept by moving actual OT systems to the cloud and proving cloud feasibility to support various OT technologies such as IoT, Machine Learning, etc. Explore threat analysis when these technologies are moved to the cloud. A detailed analysis in NREL ARIES Cyber Range will be used to conduct deeper analysis of cloud suitability to support OT and net zero system operations in a higher fidelity representative environment. Outputs will identify, quantify, and document the results and cyber security risks associated with the move of these OT technologies in a formal delivered report. Programmatic Benefits: Identify cloud integration challenges for energy systems characterize the cloud threat space, contribute to policy and standards discussions, empower the sector to change their cloud culture where appropriate.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems Integration

The fact sheet summarizes the goals and activities of the DOE Solar Energy Technologies Program efforts within its photovoltaics subprogram.

systems integration, grid integration, solar, sola↗

A Hybrid Heavy Duty Diesel Power System for Off-Road Applications—Concept Validation

A multiyear power system R&D program was completed with the objective of developing an off-road hybrid heavy duty diesel engine with front end accessory drive-integrated energy storage. This system was validated to deliver 10.5–25.6% reduction in fuel consumption over current Tier 4 Final-based 18L diesel engines, over various off-road machine application cycles. The power system consisted of a downsized heavy-duty diesel 13L engine containing advanced combustion technologies, capable of elevated peak cylinder pressures and thermal efficiencies, thermal barrier coatings, exhaust waste heat recovery via SuperTurbo™ turbocompounding, and hybrid energy assisting and recovery through both mechanical and electrical systems. Following the concept definition, design, and analysis phases of the program, the final phase focused on building and validating the performance and efficiency in laboratory tests. While aspects of the system such as start/stop and reduced off-road cooling package energy losses were only analytically evaluated, the main 13L concept engine with full hybrid system was successfully built and tested in steady-state and in transient certification and real-world application cycles. Extensive simulations in Caterpillar's DYNASTY™ software environment utilized the validation test data to assess performance more fully and confidently over varied cycles and strategies. An average fuel consumption reduction of 17.9% was realized, and the majority (~13%) of the benefit stemmed from the core concept 13L engine. In conclusion, a total cost of ownership analysis provides context to commercial viability and where adoption focus should be placed.

33 ADVANCED PROPULSION SYSTEMS↗

AVESTAR Center: Dynamic simulation-based collaboration toward achieving opertional excellence for IGCC plants with crbon capture

To address challenges in attaining operational excellence for clean energy plants, the National Energy Technology Laboratory has launched a world-class facility for Advanced Virtual Energy Simulation Training And Research (AVESTAR(TM)). The AVESTAR Center brings together state-of-the-art, real-time, high-fidelity dynamic simulators with operator training systems and 3D virtual immersive training systems into an integrated energy plant and control room environment. This paper will highlight the AVESTAR Center simulators, facilities, and comprehensive training, education, and research programs focused on the operation and control of an integrated gasification combined cycle power plant (IGCC) with carbon dioxide capture.

20 FOSSIL-FUELED POWER PLANTS↗

Energy loss analysis of an integrated space power distribution system

The results of studies related to conceptual topologies of an integrated utility-like space power system are described. The system topologies are comparatively analyzed by considering their transmission energy losses as functions of mainly distribution voltage level and load composition. The analysis is expedited by use of a Distribution System Analysis and Simulation (DSAS) software. This recently developed computer program by the Electric Power Research Institute (EPRI) uses improved load models to solve the power flow within the system. However, present shortcomings of the software with regard to space applications, and incompletely defined characteristics of a space power system make the results applicable to only the fundamental trends of energy losses of the topologies studied. Accountability, such as included, for the effects of the various parameters on the system performance can constitute part of a planning tool for a space power distribution system.

Kankam, M. David↗

Energy loss analysis of an integrated space power distribution system

The results of studies related to conceptual topologies of an integrated utility-like space power system are described. The system topologies are comparatively analyzed by considering their transmission energy losses as functions of mainly distribution voltage level and load composition. The analysis is expedited by use of a Distribution System Analysis and Simulation (DSAS) software. This recently developed computer program by the Electric Power Research Institute (EPRI) uses improved load models to solve the power flow within the system. However, present shortcomings of the software with regard to space applications, and incompletely defined characteristics of a space power system make the results applicable to only the fundamental trends of energy losses of the topologies studied. Accountability, such as included, for the effects of the various parameters on the system performance can constitute part of a planning tool for a space power distribution system.

Kankam, M. D.↗

Assessing the benefits of capacity payment, feed‐in‐tariff and time‐of‐use programme on long‐term renewable energy sources integration

Recently, demand response programmes (DRPs) have captured great attention in electric power systems. DRPs such as time‐of‐use (ToU) programme can be efficiently employed in the power system planning to reform the long‐term behaviour of the load demands. The composite generation expansion planning (GEP) and transmission expansion planning (TEP) known as composite GEP–TEP is of high significance in power systems to meet the future load demand of the system and also integrate renewable energy sources (RESs). In this regard, this study presents a dynamic optimisation framework for the composite GEP–TEP problem taking into consideration the ToU programme and also, the incentive‐based and supportive programmes. Accordingly, the performances of the capacity payment and feed‐in tariff mechanisms and the ToU programme in integrating RESs and reducing the total cost have been evaluated in this study. The problem has been formulated and solved as a standard two‐stage mixed‐integer linear programming model aimed at minimising the total costs. In this model, the ToU programme is applied and the results are fed into the expansion planning problem as the input. The proposed framework is simulated on the IEEE Reliability Test System to verify the effectiveness of the model and discuss the results obtained from implementing the mentioned mechanisms to support the RESs integration.

Javadi, Mohammad Sadegh↗

Comparing the economic performance of ice storage and batteries for buildings with on-site PV through model predictive control and optimal sizing

Integrating renewable energy and energy storage systems provides a way of operating the electrical grid system more energy efficiently and stably. Thermal storage and batteries are the most common devices for integration. However, it is not clear which integrated storage system performs better in terms of overall economics. Ice storage has low initial and maintenance costs, but there is an efficiency penalty for charging of storage and it can only shift electrical loads associated with building cooling requirements. A battery's round-trip efficiency, on the contrary, is quite consistent and batteries can be used to shift both HVAC and non-HVAC loads. However, batteries have greater initial costs and a shorter life. Finally, this research presents a tool, using model predictive control and optimal sizing, and provides a case study for comparing life-cycle economics of battery and ice storage systems for commercial buildings that have chillers for cooling and an on-site photovoltaic system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Modeling and Parametric Study of a Dual Purpose Underground Thermal Battery

Buildings’ thermal energy systems for providing space heating/cooling consume a considerable amount of electricity nationwide. Integrating thermal energy storage with buildings’ thermal systems has the potential to shave the peak electric demand and to overcome the mismatch between the intermittent renewable power and the fluctuating daily demand for electricity. A novel dual-purpose underground thermal battery (DPUTB) has been developed to provide diurnal thermal energy storage in conjunction with a dual-source heat pump (DSHP)system. A two-dimensional numerical model is developed to simulate the transient performance of the DPUTB. This model has similar accuracy as a detailed three-dimensional model developed with commercial heat transfer and fluid dynamics simulation program but with 1000 times faster computational speed. A parametric study is performed to identify a design of the DPUTB that can provide 14 kWh thermal storage capacity for each charging and discharging cycle. A system simulation has been developed to assess the performance of the designed DPUTB when it is integrated with a DSHP for conditioning a typical residential building in summer and winter. Simulation results indicate that the DPUTB can meet all the design requirements in both summer and winter with the simple rule-based control strategy and the overall integrated DPUTB and DSHP system can shift the electric load for meeting the thermal demand from the peak hours to off-peak hours during a day, which would result in considerable energy cost savings if a Time of Use electricity tariff is applicable.

25 ENERGY STORAGE↗

Systems and methods for advanced grid integration of distributed generators and energy resources

A circuit for a smart photovoltaic (PV) inverter system and the smart PV inverter system are described. The circuit includes one or more strings coupled to an electrical load. Each of the one or more strings further includes one or more string members coupled in series, where each of the one or more string members comprises a voltage source and an inverter. The circuit also includes a controller to receive an output from an operator controller and control the strings, where the controller is configured to control the strings by providing a function command to a first string member of each of the one or more strings based on the output from the operator controller. The voltage source may also receive an output from an energy output device. Further, the inverter may be configured to convert the output of energy output device into an energy source of electrical load.

Bhowmik, Shibashis↗

Understanding Impacts of Data Integrity Attacks on Transactive Control Systems

With the rapid growth of internet-connected smart devices capable of exchanging energy price information and adaptively controlling energy consumption of connected loads, the role of transactive control is expected to become more prominent in the modern grid. Transactive control systems integrate the wholesale and retail energy markets, and enable active participation of end users, thereby playing a key role in managing the rising number of distributed assets in the smart grid. The use of internet for the communication of data between the controllers at the building, distribution, and transmission levels makes the system susceptible to cyber-attacks. A skilled adversary can potentially manipulate the exchanged data with the intention of inflicting damage to the system. In this paper, four categories of metrics are put forth for evaluating the performance of the system when under data integrity attacks. A model for scaling-based data integrity attack has been described, and co-simulations have been performed on a 240 bus WECC transmission system model with detailed modeling of distribution systems at specific buses. Our results show that scaling-based data integrity attacks can have non-trivial impacts on the operational, financial, and comfort aspects of the transactive control system.

Smart grid, transactive control system, Buildings-↗

Nuclear-Renewable Energy Systems Secondary Product Market Analysis Study

In order to properly create a program surrounding the development of any technological concept it is necessary to fully understand the market in which it is being developed. In the case of Integrated Nuclear-Renewable Hybrid Energy Systems (HES), there are two economic markets in which it must be able to participate in: the electricity market and the secondary product market associated with the specific system. The purpose of the present report is to characterize the secondary product market in the U.S. and to provide recommendations for further developing the HES program. While HESs have been discussed in depth in many other reports, it is helpful to discuss them briefly in the present work [REF]. The concept of the HES can be deduced to a system, featuring a combination of a nuclear power plant, a renewable energy source, and an industrial manufacturing plant . The system is designed in a fashion that allows it either to produce electricity or to manufacture a secondary product as needed. The primary benefit of this concept lies in its ability to maximize economic performance of the integrated system and to manufacture products in a carbon-free manner. A secondary benefit is the enhanced supply-side flexibility gained by allowing the HES to economically provide grid services. A key tenant to nuclear power plant economics in today’s electricity market is their ability to operate at a very high capacity factor. Unfortunately, in regions with a high penetration of renewable energy, the carbon free energy produced by nuclear power may not be needed at all times. This forces the nuclear power plant to find a user for its excess capacity. This may include paying the electric grid to find a user, releasing energy to the environment by ‘dumping steam’, or reducing power. If the plant is unable to economically or safely do any of these actions, the plant is at risk of being shutdown. In order to allow for nuclear power plants to continue to contribute carbon free electricity to the grid in a future with high renewable energy penetration, HESs allow for excess capacity to be diverted to a chemical process. If the chemical products sold on the market replace those sold previously – which would be the case if a currently operating manufacturing plant was modified to be a HES component – then the products would now be produced with reduced emission of carbon and other greenhouse gases. There are several key economic barriers that must be surmounted for HESs to be developed. The two primary barriers are the increased capital cost associated with coupling and controlling the HES components and the decreased utilization of the manufacturing plant capital due to intermittent energy delivery . Because of this, manufacturing plants that are less complex and have smaller non-variable operations and capital costs may be more attractive for integration. A secondary economic barrier for the HES is the market availability for its products. The system must operate a region where there is either an intermittent demand for its electricity, an intermittent demand for its secondary product, or both. In a region with an intermittent demand, product prices should shift accordingly, making it less attractive to produce one of the products. The HES then can shift production in order to maximize profit. Without an intermittent demand for at least one of its products, there would be little need for it to expend the extra capital required for integration as an HES.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wireless Sensing, Monitoring and Optimization for Campus-Wide Steam Distribution

The US Congress has passed legislation dictating that all government agencies establish a plan and process for improving energy efficiencies at their sites. In response to this legislation, Oak Ridge National Laboratory (ORNL) has recently conducted a pilot study to explore the deployment of a wireless sensor system for a real-time measurement-based energy efficiency optimization. With particular focus on the 12-mile long steam distribution network in our campus, we propose an integrated system-level approach to optimize energy delivery within the steam distribution system. Our approach leverages an integrated wireless sensor and real-time monitoring capability. We make real time state assessment on the steam trap health and steam flow estimate of the distribution system by mounting acoustic sensors on the steam pipes/traps/valves and observing measurements of these sensors with state estimators for system health. Our assessments are based on a spectral-based energy signature scheme that interprets acoustic vibration sensor data to estimate steam flow rates and assess steam traps status. Experimental results show that the energy signature scheme has the potential to identify different steam trap states and it has sufficient sensitivity to estimate flow rate. Moreover, results indicate a nearly quadratic relationship over the test region between the overall energy signature factor and flow rate in the pipe. We are able to present the steam flow and steam trap status, sensor readings, and the assessed alerts as an interactive overlay within a web-based Google Earth geographic platform that enables decision makers to take remedial action. The goal is to achieve significant energy-saving in steam lines by monitoring and acting on leaking steam pipes/traps/valves. We believe our demonstration serves as an instantiation of a platform that extends implementation to include newer modalities to manage water flow, sewage and energy consumption.

54 ENVIRONMENTAL SCIENCES↗