Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EYES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Development of microchannel plate x-ray optics

The goal of this research program was to develop a novel technique for focusing x-rays based on the optical system of a lobster's eye. A lobster eye employs many closely packed reflecting surfaces arranged within a spherical or cylindrical shell. These optics have two unique properties: they have unlimited fields of view and can be manufactured via replication of identical structures. Because the angular resolution is given by the ratio of the size of the individual optical elements to the focal length, optical elements with sizes on the order of one hundred microns are required to achieve good angular resolution with a compact telescope. We employed anisotropic etching of single crystal silicon wafers for the fabrication of micron-scale optical elements. This technique, commonly referred to as silicon micromachining, is based on silicon fabrication techniques developed by the microelectronics industry. An anisotropic etchant is a chemical which etches certain silicon crystal planes much more rapidly than others. Using wafers in which the slowly etched crystal planes are aligned perpendicularly to the wafer surface, it is possible to etch a pattern completely through a wafer with very little distortion. Our optics consist of rectangular pores etched completely through group of zone axes (110) oriented silicon wafers. The larger surfaces of the pores (the mirror elements) were aligned with the group of zone axes (111) planes of the crystal perpendicular to the wafer surface. We have succeeded in producing silicon lenses with a geometry suitable for 1-d focusing x-ray optics. These lenses have an aspect ratio (40:1) suitable for x-ray reflection and have very good optical surface alignment. We have developed a number of process refinements which improved the quality of the lens geometry and the repeatability of the etch process. A significant progress was made in obtaining good optical surface quality. The RMS roughness was decreased from 110 A for our initial lenses to 30 A in the final lenses. A further factor of three improvement in surface quality is required for the production of efficient x-ray optics. In addition to the silicon fabrication, an x-ray beam line was constructed at Columbia for testing the optics.

Kaaret, Philip↗

Reduction of ocular counter-rolling by adaptation to space

We studied the three-dimensional vestibulo-ocular reflex (VOR) of rhesus monkeys before and after the COSMOS Biosatellite 2229 Mission of 1992-1993. This included tests of ocular counter-rolling (OCR), the gain of the vestibulo-ocular reflex (VOR), and spatial orientation of velocity storage. A four-axis vestibular and oculomotor stimulator was transported to the Institute of Biomedical Problems in Moscow for the pre- and postflight ground-based testing. Twelve normal juvenile male rhesus monkey were implanted surgically with eye coils and tested 60-90 days before spaceflight. Two monkey (7906 and 6151), selected from the twelve as flight animals, flew from 12/29/92 to 1/10/93. Upon recovery, they were tested for 11 days postflight along with three control animals. Compensatory ocular torsion was produced in two ways: (1) Lateral head tilts evoked OCR through otolith-ocular reflexes. OCR was also measured dynamically during off-vertical axis rotation (OVAR). (2) Rotation about a naso-occipital axis that was either vertical of horizontal elicited torsional nystagmus through semicircular canal-ocular reflexes (roll VOR). OCR from the otoliths was substantially reduced (70 percent) for 11 days after reentry on both modes of testing. The gain of the roll VOR was also decreased, but less than OCR. These data demonstrate that there was a long-lasting depression of torsional or roll eye movements after adaptation to microgravity in these monkeys, especially those movements produced by the otolith organs.

Dai, Mingjia↗

Surface science capabilities from IMP spectral imaging

The Imager for Mars Pathfinder (IMP) had a single 12-position filter wheel for one of its two 'eyes'. Originally eight, and then nine, of these filters were optimized for surface science, and three narrow-band filters for atmospheric science. Because of some design revisions we will now have filter wheels on both sides. The wheels for right and left eyes are identical, 12 filter positions each, and rigidly linked to the same rotation shaft. There are now 13 surface filters, in addition to 5 for atmospheric observations. Details of all the filter positions are tabulated and approximate gaussian bandpasses for the 13 surface filters are shown.

Singer, Robert B.↗

Development of microchannel plate x-ray optics

The goal of this research program was to develop a novel technique for focusing x-rays based on the optical system of a lobster's eye. A lobster eye employs many closely packed reflecting surfaces arranged within a spherical or cylindrical shell. These optics have two unique properties: they have unlimited fields of view and can be manufactured via replication of identical structures. Because the angular resolution is given by the ratio of the size of the individual optical elements to the focal length, optical elements with size on the order of one hundred microns are required to achieve good angular resolution with a compact telescope. We employed anisotropic etching of single crystal silicon wafers for the fabrication of micron-scale optical elements. This technique, commonly referred to as silicon micromachining, is based on silicon fabrication techniques developed by the microelectronics industry. We have succeeded in producing silicon lenses with a geometry suitable for a 1-d focusing x-ray optics. These lenses have an aspect ratio (40:1) suitable for x-ray reflection and have very good optical surface alignment. We have developed a number of process refinements which improved the quality of the lens geometry and the repeatability of the etch process. In addition to the silicon fabrication, an x-ray beam line was constructed at Columbia for testing the optics. Most recently, we have done several experiments to find the fundamental limits that the anisotropic etch process placed on the etched surface roughness.

Kaaret, Philip↗

The role of the vestibular system in manual target localization

Astronauts experience perceptual and sensory-motor disturbances during spaceflight and immediately after return to the 1-g environment of Earth. During spaceflight, sensory information from the eyes, limbs and vestibular organs is reinterpreted by the central nervous system so that astronauts can produce appropriate body movements in microgravity. Alterations in sensory-motor function may affect eye-head-hand coordination and, thus, the crewmember's ability to manually locate objects in extrapersonal space. Previous reports have demonstrated that crewmembers have difficulty in estimating joint and limb position and in pointing to memorized target positions on orbit and immediately postflight. One set of internal cues that may assist in the manual localization of objects is information from the vestibular system. This system contributes to our sense of the body's position in space by providing information on head position and movement and the orientation of the body with respect to gravity. Research on the vestibular system has concentrated on its role in oculo-motor control. Little is known about the role that vestibular information plays in manual motor control, such as reaching and pointing movements. Since central interpretation of vestibular information is altered in microgravity, it is important to determine its role in this process. This summer, we determined the importance of vestibular information in a subject's ability to point accurately toward a target in extrapersonal space. Subjects were passively rotated across the earth-vertical axis and then asked to point back to a previously-seen target. In the first paradigm, the subjects used both visual and vestibular cues for the pointing response, while, in the second paradigm, subjects used only vestibular information. Subjects were able to point with 85 percent accuracy to a target using vestibular information alone. We infer from this result that vestibular input plays a role in the spatial programming of manual responses.

Barry, Susan R.↗

Computerized In Vitro Test for Chemical Toxicity Based on Tetrahymena Swimming Patterns

An apparatus and a method for rapidly determining chemical toxicity have been evaluated as an alternative to the rabbit eye initancy test (Draize). The toxicity monitor includes an automated scoring of how motile biological cells (Tetrahymena pyriformis) slow down or otherwise change their swimming patterns in a hostile chemical environment. The method, called the motility assay (MA), is tested for 30 s to determine the chemical toxicity in 20 aqueous samples containing trace organics and salts. With equal or better detection limits, results compare favorably to in vivo animal tests of eye irritancy.

Noever, David A.↗

Generating Stereoscopic Television Images With One Camera

Straightforward technique for generating stereoscopic television images involves use of single television camera translated laterally between left- and right-eye positions. Camera acquires one of images (left- or right-eye image), and video signal from image delayed while camera translated to position where it acquires other image. Length of delay chosen so both images displayed simultaneously or as nearly simultaneously as necessary to obtain stereoscopic effect. Technique amenable to zooming in on small areas within broad scenes. Potential applications include three-dimensional viewing of geological features and meteorological events from spacecraft and aircraft, inspection of workpieces moving along conveyor belts, and aiding ground and water search-and-rescue operations. Also used to generate and display imagery for public education and general information, and possible for medical purposes.

Coan, Paul P.↗

Studies of Vestibular Neurons in Normal, Hyper- and Hypogravity

During the past year, pre-, in- and postflight studies were conducted in association with the Axon project for Bion 10 (Cosmos 2229). Recordings were made during pre- and postflight studies, from 118 horizontal semicircular canal afferents and 27 vestibular nucleus neurons in 7 rhesus monkeys; 137 pulse rotation protocols alone were executed (548 acceleration and deceleration responses were curve fit). Usable data was obtained from 127 horizontal afferents concerning their spontaneous discharge. Curve fits and analysis was made of sinusoidal and sum of sinusoidal responses from 42 and 35 horizontal afferents, respectively. Also recordings were made from neurons inflight from the two flight animals. The mean spontaneous rate varied from 128 spikes/sec. during preflight to 92 spikes/sec during postflight (day 5) - a change of 28%. In direct contrast to the results of Cosmos 2044, the best fitted neural adaptation operator (k) and the gain of the pulse response were decreased during post flight when compared to preflight. Surprisingly, the best fitted gain and k values for the sum of sines were slightly elevated during post flight tests. The gain and phase of single sine responses were compared for pre- and post flight tests and compared to a larger population of afferents. In contrast to Cosmos 2044 results where on the first day of post flight testing the gains of the best fitted sine response were skewed toward the higher values of the Miles and Braitman distribution, the gain of the best fitted sine responses during the first day of post flight testing (day 2) during Cosmos 2229 were exactly on the mode of the Miles and Braitman distribution. Thus, at least for the periodic stimuli, (pulses and sine waves) we found no change in gain and neural adaptation during post flight testing following Cosmos 2229. This conclusion is different from the one derived following the Cosmos 2044 flight. Cosmos flight 2229 differed from Cosmos flight 2044 in several significant ways: For example, during preflight, (1) The animals preflight training was different (less well trained on the gaze task) and (2) the animals were exposed to more experimental manipulations (surgical and rotational). Inflight, (1) the animals were required to make a pointing gesture (motor response) in association with eye movements to obtain reward, (2) the inflight diet was different (more balanced), (3) the feeder for one of the animals clogged following 9 days of flight resulting in evident dehydration and probably less head motion exposure in that monkey and (4) there was limited video taping of the monkeys in space. During postflight, (1) we were unable to test the flight animals until 26 hours postflight as compared to 14.5 hours during Cosmos 2044, (2) the animals received significantly more exposure to motion stimuli during postflight testing than during Cosmos 2044. These differences in the vestibular environment will require analysis of several parameters other than just neural and eye movement responses. For example, computer programs will have to be written and used to recover and quantify the number of head movements made by each animal during flight. This activity is critical to the production of neural adaptation and increased gain.

Correia, Manning J.↗

STS-78 Flight Day 10

On this tenth day of the STS-78 mission, the flight crew, Cmdr. Terence T. Henricks, Pilot Kevin R. Kregel, Payload Cmdr. Susan J. Helms, Mission Specialists Richard M. Linnehan, Charles E. Brady, Jr., and Payload Specialists Jean-Jacques Favier, Ph.D. and Robert B. Thirsk, M.D., continue to perform in a nearly flawless fashion. The crew is shown completing another of four tests focusing on the effects of microgravity on the vestibular system in the inner ear. In space, the vestibular system sometimes becomes confused as to which way is up and down, leading to nausea and disorientation. Using specially designed head gear to monitor head movement and eye coordination, Linnehan, Brady, Favier, Thirsk and Helms performed tests throughout their shifts to determine how the head and eyes track visual and motion targets in microgravity. The study is providing scientists with important information about the crews' ability to adapt to microgravity.

Source record↗

Time-to-Passage Judgments in Nonconstant Optical Flow Fields

The time until an approaching object will pass an observer (time to passage, or TTP) is optically specified by a global flow field even in the absence of local expansion or size cues. Kaiser and Mowafy have demonstrated that observers are in fact sensitive to this global flow information. The present studies investigate two factors that are usually ignored in work related to TTP: (1) non-constant motion functions and (2) concomitant eye rotation. Non-constant velocities violate an assumption of some TTP derivations, and eye rotations may complicate heading extraction. Such factors have practical significance, for example, in the case of a pilot accelerating an aircraft or executing a roll. In our studies, a flow field of constant-sized stars was presented monocularly on a large screen. TIP judgments had to be made on the basis of one target star. The flow field varied in its acceleration pattern and its roll component. Observers did not appear to utilize acceleration information. In particular, TTP with decelerating motion were consistently underestimated. TTP judgments were fairly robust with respect to roll, even when roll axis and track vector were decoupled. However, substantial decoupling between heading and track vector led to a decrement in performance, in both the presence and the absence of roll.

Kaiser, Mary K.↗

A Reevaluation of the Vestibulo-Ocular Reflex: New Ideas of its Purpose, Properties, Neural Substrate, and Disorders

Conventional views of the Vestibulo-Ocular Reflex (VOR) have emphasized testing with caloric stimuli and by passively rotating patients at low frequencies in a chair. The properties of the VOR tested under these conditions differ from the performance of this reflex during the natural function for which it evolved-locomotion. Only the VOR (and not visually mediated eye movements) can cope with the high-frequency angular and linear perturbations of the head that occur during locomotion; this is achieved by generating eye movements at short latency (less than 16 msec). Interpretation of vestibular testing is enhanced by the realization that, although the di- and trisynaptic components of the VOR are essential for this short-latency response, the overall accuracy and plasticity of the VOR depend upon a distributed, parallel network of neurons involving the vestibular nuclei. Neurons in this network variously encode inputs from the labyrinthine semicircular canals and otoliths, as well as from the visual and somatosensory systems. The central vestibular pathways branch to contact vestibular cortex (for perception) and the spinal cord (for control of posture). Thus, the vestibular nuclei basically coordinate the stabilization of gaze and posture, and contribute to the perception of verticality and self-motion. Consequently, brainstem disorders that disrupt the VOR cause not just only nystagmus, but also instability of posture (eg, increased fore-aft sway in patients with downbeat nystagmus) and disturbance of spatial orientation (eg, tilt of the subjective visual vertical in Wallenberg's syndrome).

Leigh, R. John↗

Models of Speed Discrimination

The prime purpose of this project was to investigate various theoretical issues concerning the integration of information across visual space. To date, most of the research efforts in the study of the visual system seem to have been focused in two almost non-overlaping directions. One research focus has been the low level perception as studied by psychophysics. The other focus has been the study of high level vision exemplified by the study of object perception. Most of the effort in psychophysics has been devoted to the search for the fundamental "features" of perception. The general idea is that the most peripheral processes of the visual system decompose the input into features that are then used for classification and recognition. The experimental and theoretical focus has been on finding and describing these analyzers that decompose images into useful components. Various models are then compared to the physiological measurements performed on neurons in the sensory systems. In the study of higher level perception, the work has been focused on the representation of objects and on the connections between various physical effects and object perception. In this category we find the perception of 3D from a variety of physical measurements including motion, shading and other physical phenomena. With few exceptions, there seem to be very limited development of theories describing how the visual system might combine the output of the analyzers to form the representation of visual objects. Therefore, the processes underlying the integration of information over space represent critical aspects of vision system. The understanding of these processes will have implications on our expectations for the underlying physiological mechanisms, as well as for our models of the internal representation for visual percepts. In this project, we explored several mechanisms related to spatial summation, attention, and eye movements. The project comprised three components: 1. Modeling visual search for the detection of speed deviation. 2. Perception of moving objects. 3. Exploring the role of eye movements in various visual tasks.

Source record↗

Visuo-Vestibular Interactions

Session TA3 includes short reports covering: (1) Vestibulo-Oculomotor Interaction in Long-Term Microgravity; (2) Effects of Weightlessness on the Spatial Orientation of Visually Induced Eye Movements; (3) Adaptive Modification of the Three-Dimensional Vestibulo-Ocular Reflex during Prolonged Microgravity; (4) The Dynamic Change of Brain Potential Related to Selective Attention to Visual Signals from Left and Right Visual Fields; (5) Locomotor Errors Caused by Vestibular Suppression; and (6) A Novel, Image-Based Technique for Three-Dimensional Eye Measurement.

Source record↗

STS-90 Day 10 Highlights

On this tenth day of the STS-90 mission, the flight crew, Cmdr. Richard A. Searfoss, Pilot Scott D. Altman, and Mission Specialists Richard M. Linnehan, Dafydd Rhys Williams and Kathryn P. Hire, and Payload Specialists Jay C. Buckey and James A. Pawelczyk have a relatively light day of scientific activity on board Columbia. The science crew of Mission Specialists Rick Linnehan and Dave Williams, along with Payload Specialists Jay Buckey and Jim Pawelczyk, continue investigations into how the human nervous system adapts to the weightlessness of space. All four serve as subjects in a vestibular experiment that uses an on-board rotating chair. The Visual and Vestibular Integration System (VVIS) correlates eye movements with balance. Developed by the European Space Agency, the chair stimulates the human balance system with both spinning and tilting sensations. Infrared video cameras observe and capture the eye movements that accompany the exercise.

Source record↗

Operational processing and cloud boundary detection from micro pulse lidar data

Micro Pulse Lidar (MPL) was developed at NASA Goddard Space Flight Center (GSFC) as the result of research on space-borne lidar techniques. It was designed to provide continuous, unattended observations of all significant atmospheric cloud and aerosol structure with a rugged, compact system design and the benefit of eye safety (Spinhirne 1993). The significant eye safety feature is achieved by using low pulse energies and high pulse repetition rates compared to standard lidar systems. MPL systems use a diode pumped 10 microj, 2500 Hz doubled Nd:YLF laser. In addition, a solid state Geiger mode avalanche photo diode (GAPD) photon counting detector is used allowing for quantum efficiencies approaching 70%. Other design features have previously been noted by Spinhirne (1995). Though a commercially available instrument, with nearly 20 systems operating around the world, the most extensive MPL work has come from those operated by the Atmospheric Radiation Measurement (ARM) (Stokes and Schwartz 1994) program. The diverse ability of the instrument relating to the measurement of basic cloud macrophysical structure and both cloud and aerosol radiative properties well suits the ARM research philosophy. MPL data can be used to yield many parameters including cloud boundary heights to the limit of signal attenuation, cloud scattering cross sections and optical thicknesses, planetary boundary layer heights and aerosol scattering profiles, including those into the stratosphere in nighttime cases (Hlavka et al 1996). System vertical resolution ranges from 30 m to 300 m (i.e. high and low resolution respectively) depending on system design. The lidar research group at GSFC plays an advisory role in the operation, calibration and maintenance of NASA and ARM owned MPL systems. Over the past three years, processing software and system correction techniques have been developed in anticipation of the increasing population of systems amongst the community. Datasets produced by three ARM-owned systems have served as the basis for this development. With two operating at the southern Great Plains Cloud and Radiation Testbed Site (SGP CART) since December 1993 and another at the Manus Island Atmospheric Radiation and Cloud Station (TWP ARCS) location in the tropical western Pacific since February 1997, the ARM archive contains over 4 years of observations. In addition, high resolution systems planning to come on-line at the North Slope, AK CART shortly with another scheduled to follow at the TWP ARCS-II will diversify this archive with more extensive observations.

Campbell, James R.↗

Effects of Radiation on Rat Retina after 18 days of Space Flight

Although cumulative effects an retina from low-dose radiation during prolonged spaceflight are not known, ary impairment of vision could set limits for spaceflight duration. Cosmic rays are now considered to be the cause of the "light flashes" seen during spaceflight by activating retina cells as they pass through the photoreceptors. Previous studies have also shown retinal cellular alterations and cell necrosis from high-energy, particle (HZE) radiation. Ten rats, 5 centrifuged during flight (FC) to simulate gravity and 5 in-flight stationary (FS) experiencing hypogravity, orbited Earth for 18.5 days on Cosmos 936. The animals were sacrificed 25 days post-recovery and the eyes flown to Ames Res. Ctr. The pattern of cell necrosis in the retinas from the FC group showed the same response to radiation as the FS. This would indicate that hypogravity was not a factor in the observed results. Also the cellular response in the retinas exposed in the Berkeley accelerator again matched both the FC and FS eyes. Thus all three conditions provide comparable changes and indicate HZE particles as the possible cause of the cellular alterations, channels, and breakdown.

Philpott, D.↗

New Generation Lidar Technology and Applications

Lidar has been a tool for atmospheric research for several decades. Until recently routine operational use of lidar was not known. Problems have involved a lack of appropriate technology rather than a lack of applications. Within the last few years, lidar based on a new generation of solid state lasers and detectors have changed the situation. Operational applications for cloud and aerosol research applications are now well established. In these research applications, the direct height profiling capability of lidar is typically an adjunct to other types of sensing, both passive and active. Compact eye safe lidar with the sensitivity for ground based monitoring of all significant cloud and aerosol structure and the reliability to operate full time for several years is now in routine use. The approach is known as micro pulse lidar (MPL). For MPL the laser pulse repetition rate is in the kilohertz range and the pulse energies are in the micro-Joule range. The low pulse energy permits the systems to be eye safe and reliable with solid state lasers. A number of MPL systems have been deployed since 1992 at atmospheric research sites at a variety of global locations. Accurate monitoring of cloud and aerosol vertical distribution is a critical measurement for atmospheric radiation. An airborne application of lidar cloud and aerosol profiling is retrievals of parameters from combined lidar and passive sensing involving visible, infrared and microwave frequencies. A lidar based on a large pulse, solid state diode pumped ND:YAG laser has been deployed on the NASA ER-2 high altitude research aircraft along with multi-spectral visible/IR and microwave imaging radiometers since 1993. The system has shown high reliability in an extensive series of experimental projects for cloud remote sensing. The retrieval of cirrus radiation parameters is an effective application for combined lidar and passive sensing. An approved NASA mission will soon begin long term lidar observation of atmospheric structure from space. The Geoscience Laser Altimeter System (GLAS) of the Earth Observing System is scheduled for deployment in the 2001 time frame. GLAS is both a cloud and aerosol lidar and a surface altimeter, principally for monitoring of polar ice sheets. The GLAS instrument is based on all solid state lasers operating at 40 Hz and high efficiency, solid state detectors. The design lifetime is three to five years. Data from the GLAS mission is expected to revolutionize some aspects of our understanding of the global distribution of cloud and aerosols for global climate prediction.

Spinhirne, James D.↗

Differential Absorption Measurements of Atmospheric Water Vapor with a Coherent Lidar at 2050.532 nm

Wind and water vapor are two major factors driving the Earth's atmospheric circulation, and direct measurement of these factors is needed for better understanding of basic atmospheric science, weather forecasting, and climate studies. Coherent lidar has proved to be a valuable tool for Doppler profiling of wind fields, and differential absorption lidar (DIAL) has shown its effectiveness in profiling water vapor. These two lidar techniques are generally considered distinctly different, but this paper explores an experimental combination of the Doppler and DIAL techniques for measuring both wind and water vapor with an eye-safe wavelength based on a solid-state laser material. Researchers have analyzed and demonstrated coherent DIAL water vapor measurements at 10 micrometers wavelength based on CO2 lasers. The hope of the research presented here is that the 2 gm wavelength in a holmium or thulium-based laser may offer smaller packaging and more rugged operation that the CO2-based approach. Researchers have extensively modeled 2 um coherent lasers for water vapor profiling, but no published demonstration is known. Studies have also been made, and results published on the Doppler portion, of a Nd:YAG-based coherent DIAL operating at 1.12 micrometers. Eye-safety of the 1.12 micrometer wavelength may be a concern, whereas the longer 2 micrometer and 10 micrometer systems allow a high level of eyesafety.

Koch, Grady J.↗