Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

A synthetic diagnostic for validation of electron gyroradius scale turbulence simulations against coherent scattering measurements

Comparison between spectra of short-scale density fluctuations measured with coherent electromagnetic scattering experiments and those extracted from space-resolved numerical simulations is affected by a number of systematic errors. These include the locality of scattering measurements, the different domain covered (space-resolved simulations versus wavenumber resolved measurements), and the stationarity of simulated nonlinear spectra. To bridge the gap between theory-simulations and experiments, a synthetic diagnostic for high- k scattering measurements has been developed. This synthetic scattering predicts the propagation of the beam in an anisotropic, inhomogeneous plasma and accounts for the spatial variation of the instrumental transfer function. Here the latter, in particular, is proven to provide an important calibration factor not only for the simulated spectra, but also for the measured ones, allowing the use of the synthetic diagnostic in predictive mode. Results from a case study for National Spherical Torus Experiment plasmas using high- k</em. tangential scattering system and the gyrokinetic tokamak simulation code are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Perspectives on Gamma-Ray Pulsar Emission

Pulsars are powerful sources of radiation across the electromagnetic spectrum. This paper highlights some theoretical insights into non-thermal, magnetospheric pulsar gamma-ray radiation. These advances have been driven by NASA's Fermi mission, launched in mid-2008. The Large Area Telescope (LAT) instrument on Fermi has afforded the discrimination between polar cap and slot gap/outer gap acceleration zones in young and middle-aged pulsars. Altitude discernment using the highest energy pulsar photons will be addressed, as will spectroscopic interpretation of the primary radiation mechanism in the LAT band, connecting to both polar cap/slot gap and outer gap scenarios. Focuses will mostly be on curvature radiation and magnetic pair creation, including population trends that may afford probes of the magnetospheric accelerating potential.

79 ASTRONOMY AND ASTROPHYSICS↗

Physics through the 1990s: Elementary-particle physics

The volume begins with a non-mathematical discussion of the motivation behind, and basic ideas of, elementary-particle physics theory and experiment. The progress over the past two decades with the quark model and unification of the electromagnetic and weak interactions is reviewed. Existing theoretical problems in the field, such as the origin of mass and the unification of the fundamental forces, are detailed, along with experimental programs to test the new theories. Accelerators, instrumentation, and detectors are described for both current and future facilities. Interactions with other areas of both theoretical and applied physics are presented. The sociology of the field is examined regarding the education of graduate students, the organization necessary in large-scale experiments, and the decision-making process involved in high-cost experiments. Finally, conclusions and recommendations for maintaining US excellence in theory and experiment are given. Appendices list both current and planned accelerators, and present statistical data on the US elementary-particle physics program. A glossary is included.

Source record↗

Detecting Falling Snow from Space

There is an increased interest in detecting and estimating the amount of falling snow reaching the Earth's surface in order to fully capture the atmospheric water cycle. An initial step toward global spaceborne falling snow algorithms includes determining the thresholds of detection for various active and passive sensor channel configurations, snow event cloud structures and microphysics, snowflake particle electromagnetic properties, and surface types. In this work, cloud resolving model simulations of a lake effect and synoptic snow event were used to determine the minimum amount of snow (threshold) that could be detected by the following instruments: the W -band radar of CloudSat, Global Precipitation Measurement (GPM) Dual-frequency Precipitation Radar (DPR) Ku and Ka band, and the GPM Microwave Imager (GMI) channels from 10 to 183 plus or minus 7 GHz. Eleven different snowflake shapes were used to compute radar reflectivities and passive brightness temperatures. Notable results include: (1) the W-Band radar has detection thresholds more than an order of magnitude lower than the future GPM sensors, (2) the cloud structure macrophysics influences the thresholds of detection for passive channels, (3) the snowflake microphysics plays a large role in the detection threshold for active and passive instruments, (4) with reasonable assumptions, "the passive 166 GHz channel has detection threshold values comparable to the GPM DPR Ku and Ka band radars with approximately 0.05 g per cubic meter detected at the surface, or an approximately 0.5-1 millimeter per hr. melted snow rate (equivalent to 0.5-2 centimeters per hr. solid fluffy snowflake rate). With detection levels of falling snow known, we can focus current and future retrieval efforts on detectable storms and concentrate advances on achievable results. We will also have an understanding of the light snowfall events missed by the sensors and not captured in the global estimates.

Gail Skofronick-Jackson↗

Feasibility of Using Remotely Sensed Data to Aid in Long-Term Monitoring of Biodiversity

Remote sensing is defined as making observations of an event or phenomena without physically sampling it. Typically this is done with instruments and sensors mounted on anything from poles extended over a cornfield,to airplanes,to satellites orbiting the Earth The sensors have characteristics that allow them to detect and record information regarding the emission and reflectance of electromagnetic energy from a surface or object. That information can then be represented visually on a screen or paper map or used in data analysis to inform decision-making.

Biodiversity↗

The Lunar Geophysical Network Mission

Overarching Principles: Must be better than Apollo (coverage, duration, instrument performance); Learn from the Apollo experience. Lunar Geophysical Network (LGN) New Frontiers (NF)-class mission, as part of the NF-5 call. “This mission consists of several identical landers distributed across the lunar surface, each carrying geophysical instrumentation. The primary science objectives are to characterize the Moon’s internal structure, seismic activity, global heat flow budget, bulk composition, & magnetic field.” Global distribution of multiple stations. Each station should contain a seismometer, heat flow probe, electromagnetic sounder, laser retroreflector (lunar nearside). Each station must be long-lived (e.g., approximately10 years)to allow other stations (from other countries?) to be integrated with the anchor nodes to form the International Lunar Network. Why LGN? Planetary Science: Moon represents an end-member in planetary evolution (large small body, small rocky planet); Primary planetary differentiation preserved; Key to understanding terrestrial planet initial differentiation. Lunar Science: Heat flow probes yield crustal heat budget estimates; Combined with EMS (ElectroMagnetic Sounding), the temperature profile of the deep interior can be modeled along with mineralogy; Seismic and LLR (Lunar Laser Ranging) data also yield structure and compositional information of the lunar interior; High fidelity data from LGN would enhance the usefulness of the GRAIL (Gravity Recovery and Interior Laboratory) and SELENE (Selenological and Engineering Explorer) gravity data. Human Exploration: LGN must be established prior to renewed human lunar activity - we do not know the exact locations or causes of the shallow moonquakes (SMQs) - the largest magnitude seismic events recorded by Apollo (1 event per year of magnitude greater than or equal to 5); Establishing surface infrastructure near SMQ epicenters must be avoided.

Neal, C. R.↗

X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of an Atomic Force Microscope in a Beamline Sample Environment

We developed and optimised an optics-free Atomic Force Microscope (AFM) that can be directly installed on most of the synchrotron radiation end-stations. The combination of Scanning Probe Microscopies with X-ray microbeams adds new possibilities to the variety of synchrotron radiation techniques. The instrument can be used for atomic force imaging of the investigated sample or to locally measure the X-ray absorption or diffraction, or it can also be used to mechanically interact with the sample while simultaneously taking spectroscopy or diffraction measurements. The local character of these measurements is intrinsically linked with the use of the Atomic Force Microscope tip. It is the sharpness of the tip that gives the opportunity to measure the photons flux impinging on it giving beam position monitor features, or allows to locally measure the absorption coefficient or the shape of the diffraction pattern. As an example of the possibilities opened by the instrument we will show diffraction measurements performed on a Ge/Si island while being indented with the AFM tip providing local measure of the Young coefficient. Three ESRF beamlines are going to be equipped with this new instrument.

43 PARTICLE ACCELERATORS↗

Suppression criteria of parasitic mode oscillations in a gyrotron beam tunnel

This paper presents the design criteria of the parasitic mode oscillations suppression for a periodic, ceramic, and copper loaded gyrotron beam tunnel. In such a type of beam tunnel, the suppression of parasitic mode oscillations is an important design problem. A method of beam-wave coupling coefficient and its mathematical formulation are presented. The developed design criteria are used in the beam tunnel design of a 42 GHz gyrotron to be developed for the Indian TOKAMAK system. The role of the thickness and the radius of the beam tunnel copper rings to obtain the developed design criteria are also discussed. The commercially available electromagnetic code CST and the electron trajectory code EGUN are used for the simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of instrumental systematics on the CMB bispectrum

We study the effects of instrumental systematics on the estimation of primordial non-Gaussianity using the cosmic microwave background (CMB) bispectrum from both the temperature and the polarization anisotropies. For temperature systematics we consider gain fluctuation and beam distortions. For polarization we consider effects related to known instrumental systematics: calibration, pixel rotation, differential gain, pointing, and ellipticity of the instrument beam. We consider these effects at the next to leading order, which we refer to as nonlinear systematic effects. We find that if the instrumental response is linearly proportional to the received CMB intensity, then only the shape of the primordial CMB bispectrum, if there is any, will be distorted. We show that the nonlinear response of the instrument can in general result in spurious non-Gaussian features on both the CMB temperature and polarization anisotropies, even if the primordial CMB is completely Gaussian. We determine the level for both the linear and nonlinear systematics parameters for which they would cause no significant degradation of our ability to constrain the primordial non-Gaussianity amplitude f{sub NL}. We find that the nonlinear systematics are potentially a bigger worry for extracting the primordial non-Gaussianity than the linear systematics, especially because the current and near future CMB probes are optimized for CMB power-spectrum measurements which are not particularly sensitive to the nonlinear instrument response. We find that if instrumental nonlinearities are not controlled by dedicated calibration, the effective local non-Gaussianity can be as large as f{sub NL}{approx}O(10) before the corresponding nonlinearities show up in the CMB dipole measurements. The higher-order multipoles are even less sensitive to instrumental nonlinearities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser-driven deflection arrangements and methods involving charged particle beams

Systems, methods, devices and apparatus are implemented for producing controllable charged particle beams. In one implementation, an apparatus provides a deflection force to a charged particle beam. A source produces an electromagnetic wave. A structure, that is substantially transparent to the electromagnetic wave, includes a physical structure having a repeating pattern with a period L and a tilted angle .alpha., relative to a direction of travel of the charged particle beam, the pattern affects the force of the electromagnetic wave upon the charged particle beam. A direction device introduces the electromagnetic wave to the structure to provide a phase-synchronous deflection force to the charged particle beam.

47 OTHER INSTRUMENTATION↗

Calibration and performance of the ATLAS Tile Calorimeter during the LHC Run 2

The Tile Calorimeter (TileCal) is the hadronic sampling calorimeter of the ATLAS experiment at the Large Hadron Collider (LHC). TileCal uses iron absorbers and scintillators as active material and it covers the central region | η| < 1.7. Jointly with the other sub-detectors it is designed for measurements of hadrons, jets, tau-particles and missing transverse energy. It also assists in muon identification. TileCal is regularly monitored and calibrated by several different calibration systems: a Cs radioactive source, a laser light system to check the PMT response, and a charge injection system (CIS) to check the front-end electronics. These calibration systems, in conjunction with data collected during proton-proton collisions, Minimum Bias (MB) events, provide extensive monitoring of the instrument and a means for equalizing the calorimeter response at each stage of the signal propagation. The performance of the calorimeter has been established with cosmic ray muons and the large sample of the proton-proton collisions and compared to Monte Carlo (MC) simulations. The response of high momentum isolated muons is also used to study the energy response at the electromagnetic scale, isolated hadrons are used as a probe of the hadronic response. The calorimeter time resolution is studied with multijet events. A description of the different TileCal calibration systems and the results on the calorimeter performance during the LHC Run 2 are introduced. The findings on the pile-up noise and response uniformity studies are also reported on.

47 OTHER INSTRUMENTATION↗

DEGREE-SCALE GeV 'JETS' FROM ACTIVE AND DEAD TeV BLAZARS

We show that images of TeV blazars in the GeV energy band should contain, along with point-like sources, degree-scale jet-like extensions. These GeV extensions are the result of electromagnetic cascades initiated by TeV {gamma}-rays interacting with extragalactic background light and the deflection of the cascade electrons/positrons in extragalactic magnetic fields (EGMFs). Using Monte Carlo simulations, we study the spectral and timing properties of the degree-scale extensions in simulated GeV band images of TeV blazars. We show that the brightness profile of such degree-scale extensions can be used to infer the light curve of the primary TeV {gamma}-ray source over the past 10{sup 7} yr, i.e., over a time scale comparable to the lifetime of the parent active galactic nucleus. This implies that the degree-scale jet-like GeV emission could be detected not only near known active TeV blazars, but also from 'TeV blazar remnants', whose central engines were switched off up to 10 million years ago. Since the brightness profile of the GeV 'jets' depends on the strength and the structure of the EGMF, their observation provides additional information about the EGMF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A diagnostic system for electrical faults in a high current discharge plasma setup

A diagnostic system to detect electrical faults inside a coaxial high current discharge device is presented here. This technique utilizes two biconical antennas picking up electromagnetic radiation from the discharge device, a voltage divider sensing input voltage, and a Rogowski coil measuring the main discharge current. A computer program then analyses frequency components in these signals and provides information as to whether the discharge event was normal or any breakdown fault occurred inside the coaxial device. The diagnostic system is developed for a 450 kV and 50 kA capillary discharge plasma setup. For the setup various possible faults are analyzed by electrical simulation, followed by experimental results. In the case of normal discharge through the capillary load the dominant frequency is {approx}4 MHz. Under faulty conditions, the peak in magnitude versus frequency plot of the antenna signal changes according to the fault position which involves different paths causing variation in the equivalent circuit elements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for analyzing ExB probe spectra from Hall thruster plumes

Various methods for accurately determining ion species' current fractions using ExB probes in Hall thruster plumes are investigated. The effects of peak broadening and charge exchange on the calculated values of current fractions are quantified in order to determine the importance of accounting for them in the analysis. It is shown that both peak broadening and charge exchange have a significant effect on the calculated current fractions over a variety of operating conditions, especially at operating pressures exceeding 10{sup -5} torr. However, these effects can be accounted for using a simple approximation for the velocity distribution function and a one-dimensional charge exchange correction model. In order to keep plume attenuation from charge exchange below 30%, it is recommended that pz{<=}2, where p is the measured facility pressure in units of 10{sup -5} torr and z is the distance from the thruster exit plane to the probe inlet in meters. The spatial variation of the current fractions in the plume of a Hall thruster and the error induced from taking a single-point measurement are also briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Review of Quantum Confinement

A succinct history of the Confined Atom problem is presented. The hydrogen atom confined to the centre of an impenetrable sphere counts amongst the exactly soluble problems of physics, alongside much more noted exact solutions such as Black Body Radiation and the free Hydrogen atom in absence of any radiation field. It shares with them the disadvantage of being an idealisation, while at the same time encapsulating in a simple way particular aspects of physical reality. The problem was first formulated by Sommerfeld and Welker - henceforth cited as SW - in connection with the behaviour of atoms at very high pressures, and the solution was published on the occasion of Pauli's 60th birthday celebration. At the time, it seemed that there was not much other connection with physical reality beyond a few simple aspects connected to the properties of atoms in solids, for which more appropriate models were soon developed. Thus, confined atoms attracted little attention until the advent of the metallofullerene, which provided the first example of a confined atom with properties quite closely related to those originally considered by SW. Since then, the problem has received much more attention, and many more new features of quantum confinement, quantum compression, the quantum Faraday cage, electronic reorganisation, cavity resonances, etc have been described, which are relevant to real systems. Also, a number of other situations have been uncovered experimentally to which quantum confinement is relevant. Thus, studies of the confined atom are now more numerous, and have been extended both in terms of the models used and the systems to which they can be applied. Connections to thermodynamics are explored through the properties of a confined two-level atom adapted from Einstein's celebrated model, and issues of dynamical screening of electromagnetic radiation by the confining shell are discussed in connection with the Faraday cage produced by a confining conducting shell. The conclusions are shown to be relevant to a proposed 'quantum computer'. The description of the actual geometry of C{sub 60}, as opposed to a purely spherical approximation, leads to some qualification of the computed results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design and Manufacturing Criteria for Beam Position Monitor (BPM) of Taiwan Photon Source (TPS)

There are quite some considerations when the button feedthrough is designed and manufactured in a new 3rd generation synchrotron light source like the to-be-constructed TPS. It is the responsibility of the button feedthrough designer to design a feedthrough with the lowest probable HOM problem. It is also required for the designer to analyze the consequences for each possible mechanical error during manufacturing and therefore set standards of tolerance. We have been using MAFIA to optimize the design of feedthrough including flange type on bending chamber section and primary BPM on insertion device section. We also have set some criteria for feedthrough manufacturing, inspection, and welding based on hands-on experience on feedthrough electrical properties measuring, sorting, inspection, and laser welding. Here we will present the MAFIA results, electrical measurement results, and laser welding results and analysis. Criteria based on these results will also be presented.

43 PARTICLE ACCELERATORS↗