Volt-Var Curve Reactive Power Control Requirements and Risks for Feeders with Distributed Roof-Top Photovoltaic Systems

The benefits and risks associated with Volt-Var Curve (VVC) control for management of voltages in electric feeders with distributed, roof-top photovoltaic (PV) can be defined using a stochastic hosting capacity analysis methodology. Although past work showed that a PV inverter’s reactive power can improve grid voltages for large PV installations, this study adds to the past research by evaluating the control method’s impact (both good and bad) when deployed throughout the feeder within small, distributed PV systems. The stochastic hosting capacity simulation effort iterated through hundreds of load and PV generation scenarios and various control types. The simulations also tested the impact of VVCs with tampered settings to understand the potential risks associated with a cyber-attack on all of the PV inverters scattered throughout a feeder. The simulation effort found that the VVC can have an insignificant role in managing the voltage when deployed in distributed roof-top PV inverters. This type of integration strategy will result in little to no harm when subjected to a successful cyber-attack that alters the VVC settings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Endpoint Use Efficiency Comparison for AC and DC Power Distribution in Commercial Buildings

Advances in power electronics and their use in Miscellaneous Electric Loads (MELs) in buildings have resulted in increased interest in using low-voltage direct current (DC) power distribution as a replacement for the standard alternating current (AC) power distribution in buildings. Both systems require an endpoint converter to convert the distribution system voltage to the MELs voltage requirements. This study focused on the efficiency of these endpoint converters by testing pairs of AC/DC and DC/DC power converters powering the same load profile. In contrast to prior studies, which estimated losses based on data sheet efficiency and rated loads, in this study, we used part load data derived from real-world time-series load measurements of MELs and experimentally characterized efficiency curves for all converters. The measurements performed for this study showed no systematic efficiency advantage for commercially available DC/DC endpoint converters relative to comparable, commercially available AC/DC endpoint converters. For the eight appliances analyzed with the pair of converters tested, in 50%, the weighted energy efficiency of the DC/DC converter was higher, while, for the other 50%, the AC/DC converter was. Additionally, the measurements indicated that the common assumption of using either data sheet efficiency values or efficiency at full load may result in substantial mis-estimates of the system efficiency.

AC/DC converters↗

GA-Based Voltage Optimization of Distribution Feeder with High-Penetration of DERs Using Megawatt-Scale Units

In this paper, genetic algorithm (GA)-based voltage optimization of a modified IEEE-34 node distribution feeder with high penetration of distributed energy resources (DERs) is proposed using two megawatt-scale reactive power sources. Traditional voltage support units present in distribution grids are not suitable for DER-rich feeders, while voltage support using small-scale DERs present in the feeder requires considerable communication effort to reach a global solution. In this work, two megawatt-scale units are placed to improve the voltage profile across the IEEE 34-node feeder, which has been modified to include several PV units and an energy storage unit. The megawatt-scale units are optimized using GA for fast and accurate operation. The performance of the proposed scheme is verified using simulation results with a multi-platform setup where the modified IEEE-34 node feeder is modeled in OpenDSS while the GA optimization scheme is programmed in MATLAB.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distance Estimate Method for Asymptotic Giant Branch Stars Using Infrared Spectral Energy Distributions

We present a method to estimate distances to asymptotic giant branch (AGB) stars in the Galaxy, using spectral energy distributions (SEDs) in the near- and mid-infrared. By assuming that a given set of source properties (initial mass, stellar temperature, composition, and evolutionary stage) will provide a typical SED shape and brightness, sources are color matched to a distance-calibrated template and thereafter scaled to extract the distance. The method is tested by comparing the distances obtained to those estimated from very long baseline interferometry or Gaia parallax measurements, yielding a strong correlation in both cases. Additional templates are formed by constructing a source sample likely to be close to the Galactic center, and thus with a common, typical distance for calibration of the templates. These first results provide statistical distance estimates to a set of almost 15,000 Milky Way AGB stars belonging to the Bulge Asymmetries and Dynamical Evolution (BAaDE) survey, with typical distance errors of ±35%. With these statistical distances, a map of the intermediate-age population of stars traced by AGBs is formed, and a clear bar structure can be discerned, consistent with the previously reported inclination angle of 30° to the GC–Sun direction vector. These results motivate deeper studies of the AGB population to tease out the intermediate-age stellar distribution throughout the Galaxy, as well as determining statistical properties of the AGB population luminosity and mass-loss-rate distributions.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating the potential of short-term instrument deployment to improve distributed wind resource assessment

Distributed wind projects, which are connected at the distribution level of an electricity system or in off-grid applications to serve specific or local energy needs, often rely solely on wind resource models to establish wind speed and energy generation expectations. Historically, anemometer loan programs have provided an affordable avenue for more accurate onsite wind resource assessment, and the lowering cost of lidar systems has shown similar advantages for more recent assessments. While a full 12 months of onsite wind measurement is the standard for correcting model-based long-term wind speed estimates for utility-scale wind farms, the time and capital investment involved in gathering onsite measurements must be reconciled with the energy needs and funding opportunities that drive expedient deployment of distributed wind projects. Much literature exists to quantify the performance of correcting long-term wind speed estimates with 1 or more years of observational data, but few studies explore the impacts of correcting with months-long observational periods. This study aims to answer the question of how short you can go in terms of the observational time period needed to make impactful improvements to model-based long-term wind speed estimates. Three algorithms, multivariable linear regression, adaptive regression splines, and regression trees, are evaluated for their skill at correcting long-term wind resource estimates from the European Centre for Medium-Range Weather Forecasts Reanalysis version 5 (ERA5) using months-long periods of observational data from 66 locations across the US. On average, correction with even 1 month of observations provides significant improvement over the baseline ERA5 wind speed estimates and produces median bias magnitudes and relative errors within 0.22 m s −1 and 4 percentage points of the median bias magnitudes and relative errors achieved using the standard 12 months of data for correction. However, in cases when the shortest observational periods (1 to 2 months) used for correction are not well correlated with the overlapping ERA5 reference, the resultant long-term wind speed errors are worse than those produced using ERA5 without correction. Summer months, which are characterized by weaker relative wind speeds and standard deviations for most of the evaluation sites, tend to produce the worst results for long-term correction using months-long observations. The three tested algorithms perform similarly for long-term wind speed bias; however, regression trees perform notably worse than multivariable linear regression and adaptive regression splines in terms of correlation when using 6 months or less of observational data for correction. Translating the analysis to wind energy, median relative errors in the capacity factor are on average within 10 % using 1 month of training. If the observation period used for correction is not well correlated with the reference data, however, misrepresentation of the observed capacity factor can be substantial. The risk associated with poor correlation between the observed and reference datasets decreases with increasing training period length. In the worst-correlation scenarios, the median capacity factor relative errors from using 1, 3, and 6 months are within 47 %, 26 %, and 16 %, respectively.

17 WIND ENERGY↗

Aerodynamic diameter particle size distributions for the AGINSGP experiment

Aerodynamic size distributions were collected by the APS 3321 (TSI Inc.) in the guest instrument facility at ARM’s Southern Great Plains site, during the AGINSGP field campaign. The APS accelerates particle through an orifice and uses two overlapping laser beams to measure the time-of-flights for particles. The aerodynamic diameter controls how quickly a particle will accelerate, with larger particles accelerating more slowly due to their greater inertia. The APS measures particle size distributions from 0.542 to 19.81 µm. Size distributions are averaged to their 1 minute averages. Air was drawn into the GIF through custom aluminum stack inlets (6” inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8” or 1/4" copper lines, depending on sample flow of the instrument.

54 ENVIRONMENTAL SCIENCES↗

Tethered Balloon Observations of Vertically Resolved Aerosol Size Distributions during the U.S. DOE ARM CoURAGE and BNF Campaigns

This dataset contains vertically resolved aerosol particle number size distributions measured using a miniature Scanning Electrical Mobility Spectrometer (mSEMS) deployed aboard the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Tethered Balloon System (TBS) during the 2025 Coast-Urban-Rural Atmospheric Gradient Experiment (CoURAGE) and Bankhead National Forest (BNF) field campaigns. The mSEMS measured aerosol size distributions over approximately 10–300 nm during repeated TBS vertical profiles through the atmospheric boundary layer. The dataset provides measurements of particle number size distributions as a function of particle diameter, altitude, and time and supports investigation of aerosol vertical structure, elevated ultrafine and Aitken-mode particle layers, boundary-layer evolution, and residual-layer processes.

ARM↗

Real-time disaggregation of renewable energy generation on an electricity distribution system

Techniques are described for disaggregation of renewable energy generation on an electricity distribution system. Aggregate power measurements are identified a distribution substation. Active power load of the distribution substation and active power generated by renewable energy sites can be disaggregated from the aggregate power measurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation: Preprint

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyber attacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyber attack scenarios on matrix completion. Realistic cyber attack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration: Preprint

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Resilient Operation of Power Distribution Systems Using MPC-Based Critical Service Restoration

Power distribution systems are more prone to disruptions and cause most power system outages. We propose a service restoration technique to recover the system service (electricity delivery) following an extreme event-triggered substation outage. The proposed technique considers the problem of controlling distributed energy resources (DERs) of a distribution system with the objective of achieving maximum load pick up while satisfying network flow and voltage constraints. The problem is formulated as a model predictive control (MPC), where a linearized optimal power flow (OPF) model is employed to describe the network. The formulation is augmented with a ramping (up) reserve product for the DERs to ensure an upward monotonic load restoration as time evolves. We perform simulations considering the IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage devices. We demonstrate the efficacy of the devised technique in restoring the system loads monotonically, without shedding previously restored loads. We also show the benefit of co-optimization of power and reserve products for DERs on service restoration. In addition, the capability of the technique in regulating nodal voltages and reducing renewable power curtailment is demonstrated.

61 RADIATION PROTECTION AND DOSIMETRY↗

Hardware-in-the-Loop Evaluation of an Advanced Distributed Energy Resource Management Algorithm

This paper presents the laboratory performance evaluation of voltage regulation under a new distributed energy resource management system (DERMS) algorithm via an advanced hardware-in-the-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory environment, including the accurate modeling of a full-scale real-world distribution system from a utility partner, the DERMS software controller, and power hardware photovoltaic (PV) inverters. The new DERMS algorithm is developed based on online multi-objective optimization (OMOO) algorithms that perform fast dispatch of distributed solar PV simulated in a real-time digital simulator and real physical hardware devices. Experimental tests confirm the correct functioning of the HIL platform for evaluating controller algorithms and satisfactory voltage regulation performance of the developed OMOO algorithms.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Hardware-in-the-Loop Evaluation of an Advanced Distributed Energy Resource Management Algorithm: Preprint

This paper presents the laboratory performance evaluation of voltage regulation under a new distributed energy resource management system (DERMS) algorithm via an advanced hardware-in-tbe-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory environment, including the accurate modeling of a full-scale real-world distribution system from a utility partner, the DERMS software controller, and power hardware photovoltaic (PV) inverters. The new DERMS algorithm is developed based on online multiobjective optimization (OMOO) algorithms that perform fast dispatch of distributed solar PV simulated in a real-time digital simulator and real physical hardware devices. Experimental tests confirm the correct functioning of the HIL platform for evaluating controller algorithms and satisfactory voltage regulation performance of the developed OMOO algorithms.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage: Preprint

The energy system infrastructure that delivers power to a building's loads needs to be resilient, such that it can withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose a set of novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

Cyber-Resilient Distributed Autonomous Energy Grid

The aim of Cyber-Resilient Distributed Autonomous Grid research initiative is to advance fundamental science and engineering approaches for cyber-resilient design, control, and operation of a distributed, highly interconnected, and autonomous energy grid of the future. From increasing penetration of DERs, smart homes and building with highly controllable loads at the distribution layer, to the interconnection of bulk renewables at the transmission layer the fundamental nature of the energy grid is changing, and these changes are enabled by rapid increase in dependence on the communication infrastructure and independent third parties for control and operation of the grid. NREL's Integrated Energy Pathways critical objective correctly identifies that there are fundamental cyber-resilience challenges inherent in the grid's evolution, and this effort is establishing strong and novel integrated cyber-resilience framework and approaches to address these new and fundamental challenges.

controls↗

Cybersecurity for Distributed Wind: MIRACL Advisory Board Meeting 2022

This presentation for the MIRACL Industry Advisory Board summarizes the cybersecurity research for distributed wind that was performed during the project. Highlights include an overview of the distributed wind reference architecture, descriptions of the unique needs and challenges for securing distributed wind, the cyber risk management framework that was developed for this project, and key takeaways for various stakeholders.

17 WIND ENERGY↗

Risk-Informed Condition Evaluation of Solar-centered Energy Generation and Distribution Networks through Bayesian Learning and Inference

We develop a methodology based on Bayesian inference over Probabilistic Graphical Models (PGMs) to understand and quantify risk in solar-centered grids using targeted measurements and learned system behavior. Being non-prescriptive but, rather, able to infer system behavior and, ultimately, address risk queries from data, our machine learning-type paradigm is tailored for diverse topologies and threat scenarios often associated with distributed energy generation and photovoltaic distributed energy resources (PV-DERs) in particular. We describe algorithmic processes for: (i) learning the structure of PGMs that result from attack-prone PV-DER-proliferated distribution systems, (ii) quantifying cause-effect relationships, and (iii) evaluating risk queries based on diverse evidence. The contributions are illustrated on a residential grid subject to output impairment attacks on its PV-DER infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Understanding Line Losses and Transformer Losses in Rural Isolated Distribution Systems: Preprint

Rural, isolated power systems in the mainland U.S. and in states like Alaska and Hawaii are powered by assets like diesel generators. These rural, isolated power systems also cannot operate at the higher band of medium voltage (like 69kV). They are primarily in the 12 to 14 kV range to keep the cost of the distribution investments lower. Because of this mid-band medium voltage range, the line losses and distribution transformers losses consume significant diesel consumption (almost 10 percent of the peak load). This work considers one such power system powering an isolated system and presents key findings online losses, and transformer losses. Understanding and documenting the impacts is critical for these communities operating their power systems and take actions to reduce expensive diesel consumption. In this paper, we will present one such typical grid and model it in electromagnetic transients (EMT) domain. We used the tower structure, under ground cabling installation to develop high fidelity models of lines. We also used high fidelity models of distribution transformers to present the no-load losses and full load loses. We will also present technical solutions available commercially off-the-shelf to reduce these losses and reduce diesel consumption. This work will be a primer for communities to understand the technical challenges and to understand the possible solution available to solve such challenges for rural, isolated power system operators.