Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Highly versatile computer-controlled television detector system

A description is presented of a television detector system which has been designed to accommodate a wide range of applications. It is currently being developed for use in X-ray diffraction, X-ray astrophysics, and electron microscopy, but it is also well suited for astronomical observations. The image can be integrated in a large, high-speed memory system, in the memory of a computer system, or the target of the TV tube or CCD array. The detector system consists of a continuously scanned, intensified SIT vidicon with scan and processing electronics which generate a digital image that is integrated in the detector memory. Attention is given to details regarding the camera system, scan control and image processing electronics, the memory system, and aspects of detector performance.

Kalata, K.↗

Fabrication of OMT-Coupled Kinetic Inductance Detector for CMB Detection

Future cosmic microwave background (CMB) experiments, including the large scale ground-based Stage Four CMB Experiment (CMB-S4), satellites, and balloons, aim to map the CMB to an unprecedented precision in order to answer several key questions in cosmology. However, to reach the target noise sensitivity, more than 100,000 detectors will be needed. Arrays of kinetic inductance detectors (KIDs) are a promising alternative for experiments that require large number of detectors due to the intrinsic multiplexing capabilities. We present the fabrication procedure for a prototype planar orthomode transducer (OMT)-coupled multi-color KID array optimized for 220/270 GHz frequency bands. These devices are made from silicon-on-insulator wafers to provide a low-loss substrate for the KIDs. The OMT couples the two polarizations of light from a wide-band feedhorn to separate Nb/SiN/Nb microstrip lines, which are then coupled to Al/Nb lumped-element KIDs (LEKIDs). The silicon on the backside of the OMT is etched away using deep reactive ion etch to release the OMT membrane to enable operation over a wide bandwidth. Finally, the buried oxide is removed underneath the KID capacitors in order to minimize two-level system noise and loss mitigation. We achieved a good yield (> 80%) on our prototype devices.

47 OTHER INSTRUMENTATION↗

Commercially Fabricated Antenna-Coupled Transition Edge Sensor Bolometer Detectors for Next-Generation Cosmic Microwave Background Polarimetry Experiment

We report on the development of commercially fabricated multi-chronic antenna-coupled transition edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments. The orders of magnitude increase in detector count for next-generation CMB experiments require a new approach in detector wafer production to increase fabrication throughput. Here, we describe collaborative efforts with a commercial superconductor electronics fabrication facility (SeeQC, Inc.) to fabricate antenna-coupled TES bolometer detectors. We have successfully fabricated an operational dual-polarization, dichroic sinuous antenna-coupled TES detector array on a 150-mm-diameter wafer. The fabricated detector arrays have average yield of 95% and excellent uniformity across the wafer. Both RF characteristics and TES bolometer properties are suitable for CMB observations. We successfully fabricated different types of TES bolometers optimized for frequency multiplexing readout, time-domain multiplexing readout, and microwave SQUID multiplexing readout. We also demonstrated high production throughput. We discuss the motivation, design considerations, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments.

47 OTHER INSTRUMENTATION↗

Novel technique for the study of pileup events in cryogenic bolometers

Precise characterization of detector time resolution is of crucial importance for next-generation cryogenic-bolometer experiments searching for neutrinoless double-beta decay, such as CUPID, in order to reject background due to pile-up of two-neutrino double-beta decay events. In this paper, we describe a technique developed to study the pile-up rejection capability of cryogenic bolometers. Our approach, which consists of producing controlled pile-up events with a programmable waveform generator, has the benefit that we can reliably and reproducibly control the time separation and relative energy of the individual components of the generated pile-up events. The resulting data allow us to optimize and benchmark analysis strategies to discriminate between individual and pile-up pulses. We describe a test of this technique performed with a small array of detectors at the Laboratori Nazionali del Gran Sasso, in Italy; we obtain a 90% rejection efficiency against pulser-generated pile-up events with rise time of ~15 ms down to time separation between the individual events of 2 ms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Automated Hybridization of X-ray Absorber Elements-A Path to Large Format Microcalorimeter Arrays

In the design of microcalorimeters, it is often desirable to produce the X-ray absorber separately from the detector element. In this case, the attachment of the absorber to the detector element with the required thermal and mechanical characteristics is a major challenge. In such arrays, the attachment has been done by hand. This process is not easily extended to the large format arrays required for future X- ray astronomy missions such as the New x-ray Telescope or NeXT. In this paper we present an automated process for attaching absorber tiles to the surface of a large-scale X-ray detector array. The absorbers are attached with stycast epoxy to a thermally isolating polymer structure made of SU-8. SU-8 is a negative epoxy based photo resist produced by Microchem. We describe the fabrication of the X-ray absorbers and their suspension on a handle die in an adhesive matrix. We describe the production process for the polymer isolators on the detector elements. We have developed a new process for the alignment, and simultaneous bonding of the absorber tiles to an entire detector array. This process uses equipment and techniques used in the flip-chip bonding industry and approaches developed in the fabrication of the XRS-2 instrument. XRS-2 was an X-ray spectrometer that was launched on the Suzaku telescope in July 10, 2005. We describe the process and show examples of sample arrays produced by this process. Arrays with up to 300 elements have been bonded. The present tests have used dummy absorbers made of Si. In future work, we will demonstrate bonding of HgTe absorbers.

Moseley, S.↗

The Single Aperture Far-Infrared (SAFIR) Observatory and its Cryogenic Detector Needs

The development of a large, far-infrared telescope in space has taken on a new urgency with breakthroughs in detector technology and recognition of the fundamental importance of the far-infrared spectral region to questions ranging from cosmology to our own Solar System. The Single Aperture Far-InfraRed (SAFIR) Observatory is l0m-class far-infrared observatory that would begin development later in this decade to meet these needs. SAFIR's science goals are driven by the fact that youngest stages of almost all phenomena in the universe are shrouded in absorption by and emission from cool dust that emits strongly in the far-infrared, 20 microns - 1mm. Its operating temperature (4 K) and instrument complement would be optimized to reach the natural sky confusion limit in the far-infrared with diffraction-limited performance down to at least the atmospheric cutoff at 40 microns. This would provide a point source sensitivity improvement of several orders of magnitude over that of SIRTF. In order to achieve this, large arrays of detectors with NEPs ranging from a few to a hundred zeptowatts/sqrt(Hz) are needed. Very low temperature superconducting transition edge sensors and far-infrared "photon counting" detectors are critical technologies requiring development for the SAFIR mission.

Benford, Dominic J.↗

IER 488: MUSiC Accomplishments and Goals [Slides]

IER-488: Measurement of Uranium Subcritical and Critical (MUSiC) consists of measurements of bare, HEU systems covering a large range of reactivities. Multiple detector systems and analysis methods are being used to obtain detector-independent results. Massive amounts of data and information available. Substantial analysis has been completed for both critical and subcritical configurations. Work in progress is largely novel research and will result in several conference proceedings, journal publications, and a subcritical benchmark. There is still a large amount of data that has not been analyzed and much more to come from the analysis of the Measurements of Uranium Subcritical and Critical.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary NoMAD Results of the MUSIC Experiment

The Measurement of Uranium Subcritical and Critical (MUSiC) experiment was carried out from December 2020 through April 2021 at the National Criticality Experiments Research Center (NCERC). This measurement campaign featured bare configurations of the Rocky Flats highly-enriched uranium (HEU) shells, with each configuration having different numbers of these shells. The goal of the experiment was to test multiple neutron multiplicity detectors and measurement methods for a large range of neutron multiplication values, to see when the combination of detectors and methods break down as the configurations reach the delayed supercritical window. Adding subcritical integral benchmarks gives additional validation to nuclear data. These benchmarks provide additional parameters against which to validate the data. While critical benchmarks have just a single value, $K_{eff}$ , subcritical benchmarks can be used to infer multiple parameters. As an example, recent subcritical benchmarks utilizing the Hage-Cifarelli formalism have three quantities of interest ($R_{1}$, $R_{2}$, and $M_{L}$). This gives nuclear data evaluators additional data to use when performing their evaluations, and allows for these benchmarks to be useful for additional types of nuclear data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mosaic wedge-and-strip arrays for large format microchannel plate detectors

The authors present a novel method for joining wedge-and-strip patterns on single anodes in a mosaic array. With only a modest increase in complexity over three-conductor anodes currently in use, the ultimate detector position resolution can be significantly improved, and large-format microchannel plate detectors with pore-size-limited resolution are made possible. The problem of the transition from one anode to the next has been solved with a novel linear encoding scheme, which exhibits essentially distortionless behavior at boundaries parallel to the conducting elements and only slight distortion at the orthogonal boundaries. The ultimate resolution for two anode designs, one designed for large-format imaging and the other for high-resolution spectroscopy, is also predicted.

Martin, Christopher↗

Corroborating VNA and thermal measurements of transmission loss on the DIII-D ECH waveguide system

Electron cyclotron heating (ECH) and current drive (ECCD) will play a large role in tokamak-based fusion reactors. At the DIII-D tokamak, 110 GHz microwaves injected into the plasma can provide core heating and current drive as well as impurity control, neoclassical tearing mode mitigation, and breakdown assistance. Understanding the physics of these processes relies on accurate estimates of injected ECH power. DIII-D’s ECH system consists of six MW-class Microwave Power Products (MPP) gyrotron microwave sources. Operating the gyrotrons far from the tokamak removes them from magnetic field interference, so 31.75 mm inner-diameter corrugated waveguides transmit the microwave power the 80 m from the gyrotrons to steerable launchers in the tokamak chamber. Estimates of injected power rely on knowing the generated power at the source and then subtracting transmission loss. Conventional transmission loss measurements based on calorimetric dummy loads are onerous and only possible during extended maintenance periods. This work examines two tools that provide more flexibility for the transmission loss measurements. Furthermore, a resistive temperature detector (RTD) array installed along a waveguide measures heat lost to the transmission line, and low power time domain reflectometry (TDR) measurements with a vector network analyzer (VNA) allows loss measurements without burdensome hardware modifications.

ECH↗

Measurements of D–D fusion neutrons generated in nanowire array laser plasma using Timepix3 detector

Here, we present results of the neutron detection in laser plasma experiment with CD2 nanowire target. A hybrid semiconductor pixel detector Timepix3 covered with neutron converters was using for the detection neutrons. D-D fusion neutrons were detected in a plastic converter through recoiled protons. Both the energy of recoiled protons and time-of-flight of neutrons (and thus their energy) were determined. We report (2.4±1.8) × 10 7 neutrons generated for 1 J of incoming laser energy. Furthermore, we proved that Timepix3 is suitable for difficult operational conditions in laser experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Molecular Characterization of Water-Soluble Brown Carbon Chromophores in Snowpack from Northern Xinjiang, China

This study reports molecular-level characterization of brown carbon (BrC) attributed to water-soluble organic carbon in six snowpack samples collected from northern Xinjiang, China. Here, the molecular composition and light-absorbing properties of BrC chromophores were unraveled by application of high-performance liquid chromatography (HPLC) coupled to a photodiode array (PDA) detector and high-resolution mass spectrometry. The chromophores were classified into five major types, that is, (1) phenolic/lignin-derived compounds, (2) flavonoids, (3) nitroaromatics, (4) oxygenated aromatics, and (5) other chromophores. Identified chromophores account for ~23–64% of the total light absorption measured by the PDA detector in the wavelength range of 300–370 nm. In the representative samples from urban and remote areas, oxygenated aromatics and nitroaromatics dominate the absorption in the wavelengths below and above 320 nm, respectively. The highly polluted urban sample shows the most complex HPLC-PDA chromatogram, and more other chromophores contribute to the bulk absorption. Phenolic/ lignin-derived compounds are the most light-absorbing species in the soil-influenced sample. Chromophores in two remote samples exhibit ultraviolet–visible features distinct from other samples, which are attributed to flavonoids. Identification of individual chromophores and quantitative analysis of their optical properties are helpful for elucidating the roles of BrC in snow radiative balance and photochemistry.

54 ENVIRONMENTAL SCIENCES↗

Investigating the Impacts of Daytime Boundary Layer Clouds on Surface Energy Fluxes and Boundary Layer Structure During CHEESEHEAD19

Studies of land-atmosphere interactions under a clear sky and low cumulus cloud conditions are common from long-term observatories like at the southern great plains. How well the relationships and responses of surface radiative and turbulent heat fluxes determined from these investigations hold for more heterogeneous surfaces in other climate regimes, however, is uncertain. In this study, detailed observations of the surface energy budget and daytime boundary layer properties are analyzed using measurements from the Chequamegon Heterogenous Ecosystem Energy-Balance Study Enabled by a High-Density Extensive Array of Detectors 2019 (CHEESEHEAD19) field campaign, July-October 2019, across a heterogeneous forested landscape of northern Wisconsin. A cloud regime framework is employed to classify consecutive periods of clear skies from lower atmosphere stratiform and cumulus clouds. A seasonal transition from low cumulus to low stratiform periods occurred, together with a diurnal pattern in cloudy or clear sky period dominance. Radiative forcing was highly dependent on sky conditions, leading to changes in the redistribution efficiency of radiative energy by the surface turbulent heat fluxes. During CHEESEHEAD19, small Bowen ratios dominated with daytime latent heat fluxes three times as large as sensible heat fluxes for all sky conditions studied; the forested region, therefore, falls within an energy-limited regime. The depth of the daytime mixed layer depended upon the sky condition and thermodynamic setting; deeper mixed layers occurred during periods of low cumulus and not clear skies. Profiles of vertical velocity were found to have enhanced variance under low cumulus compared to clear sky periods, suggesting potential for cloud feedbacks on boundary layer structure and surface energy fluxes.

54 ENVIRONMENTAL SCIENCES↗

Drivers of Decadal Carbon Fluxes Across Temperate Ecosystems

Long-running eddy covariance flux towers provide insights into how the terrestrial carbon cycle operates over multiple timescales. Here, we evaluated variation in net ecosystem exchange (NEE) of carbon dioxide (CO 2 ) across the Chequamegon Ecosystem-Atmosphere Study AmeriFlux core site cluster in the upper Great Lakes region of the USA from 1997 to 2020. The tower network included two mature hardwood forests with differing management regimes (US-WCr and US-Syv), two fen wetlands with varying levels of canopy sheltering and vegetation (US-Los and US-ALQ), and a very tall (400 m) landscape-level tower (US-PFa). Together, they provided over 70 site-years of observations. The 19-tower Chequamegon Heterogenous Ecosystem Energy-balance Study Enabled by a High-density Extensive Array of Detectors 2019 campaign centered around US-PFa provided additional information on the spatial variation of NEE. Decadal variability was present in all long-term sites, but cross-site coherence in interannual NEE in the earlier part of the record became weaker with time as non-climatic factors such as local disturbances likely dominated flux time series. Average decadal NEE at the tall tower transitioned from carbon source to sink to near neutral over 24 years. Respiration had a greater effect than photosynthesis on driving variations in NEE at all sites. Declining snowfall offset potential increases in assimilation from warmer springs, as less-insulated soils delayed start of spring green-up. Higher CO 2 increased maximum net assimilation parameters but not total gross primary productivity. Stand-scale sites were larger net sinks than the landscape tower. Clustered, long-term carbon flux observations provide value for understanding the diverse links between carbon and climate and the challenges of upscaling these responses across space.

54 ENVIRONMENTAL SCIENCES↗

Airborne Measurements of Scale‐Dependent Latent Heat Flux Impacted by Water Vapor and Vertical Velocity Over Heterogeneous Land Surfaces During the CHEESEHEAD19 Campaign

Abstract The water vapor transport associated with latent heat flux (LE) in the planetary boundary layer (PBL) is critical for the atmospheric hydrological cycle, radiation balance, and cloud formation. The spatiotemporal variability of LE and water vapor mixing ratio ( r v ) are poorly understood due to the scale‐dependent and nonlinear atmospheric transport responses to land surface heterogeneity. Here, airborne in situ measurements with the wavelet technique are utilized to investigate scale‐dependent relationships among LE, vertical velocity ( w ) variance (), and r v variance () over a heterogeneous surface during the Chequamegon Heterogeneous Ecosystem Energy‐balance Study Enabled by a High‐density Extensive Array of Detectors 2019 (CHEESEHEAD19) field campaign. Our findings reveal distinct scale distributions of LE, , and at 100 m height, with a majority scale range of 120 m–4 km in LE, 32 m–2 km in , and 200 m–8 km in . The scales are classified into three scale ranges, the turbulent scale (8–200 m), large‐eddy scale (200 m–2 km), and mesoscale (2–8 km) to evaluate scale‐resolved LE contributed by and . The large‐eddy scale in PBL contributes over 70% of the monthly mean total LE with equal parts (50%) of contributions from and . The monthly temporal variations mainly come from the first two major contributing classified scales in LE, , and . These results confirm the dominant role of the large‐eddy scale in the PBL in the vertical moisture transport from the surface to the PBL, while the mesoscale is shown to contribute an additional ∼20%. This analysis complements published scale‐dependent LE variations, which lack detailed scale‐dependent vertical velocity and moisture information.

54 ENVIRONMENTAL SCIENCES↗

High-yield magnetic recoil neutron spectrometer on the National Ignition Facility for operation up to 60 MJ

We report that recent progress at the National Ignition Facility (NIF), with neutron yields of order 1 x 10 17 , places new constraints on diagnostics used to characterize implosion performance. The Magnetic Recoil neutron Spectrometer (MRS), which is routinely used to measure yield, ion temperature (T ion ), and down-scatter ratio (dsr), has been adapted to allow measurements of dsr up to 5 x 10 17 , and yield and T ion up to 2 x 10 18 in the near term with new data processing techniques and conversion foil solutions. This paper presents a solution for extending MRS operation up to a yield of 2 x 10 19 (60 MJ) by moving the spectrometer outside of the NIF shield wall. This will not only enhance the upper yield limit by 10x but also improve signal-to-background by 5x.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electronic angle focusing for neutron time-of-flight powder diffractometers

A neutron time-of-flight (TOF) powder diffractometer with a continuous wide-angle array of detectors can be electronically focused to make a single pseudo-constant wavelength diffraction pattern, thus facilitating angle-dependent intensity corrections. The resulting powder diffraction peak profiles are affected by the neutron source emission profile and resemble the function currently used for TOF diffraction.

electronic focusing↗

Reply to “Comment on ‘The Reduced Detection Rate of Signals That Are Hidden by Earthquakes: Case Studies with Spotlight Detectors That Operate at Seismic Arrays,’ by Joshua D. Carmichael, Brent G. Delbridge, and Richard Alfaro-Diaz” by Paul G. Richards

We reply to a comment that Paul G. Richards (Richards, 2026) directed to an article by Carmichael et al. (2025). Richards expressed concern over two issues. The first issue relates to the size of the explosions discussed in the article. The second relates to the probability that earthquakes and explosions sourced near the same location coincide in time, by chance. We do not address the first issue because the original article does not assign significance to the size of the explosions from the point of view of an experimental party. We do respond to Richards’ comment on the second issue and claim that it can be explained through a clarification about conditional versus joint probabilities. Our present discussion, therefore, describes the difference between the conditional probability that a correlator fails, given that an explosion and earthquake coincidently occur in the same place, and the joint probability that a correlator fails while an earthquake and explosion also coincidentally occur in the same place. This latter, joint probability appears to be rare. We clarify that our original article did not treat the joint probability, only the conditional probability.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗