Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection and Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

New giant planet beyond the snow line for an extended MOA exoplanet microlens sample

Characterizing a planet detected by microlensing is hard if the planetary signal is weak or the lens-source relative trajectory is far from caustics. However, statistical analyses of planet demography must include those planets to accurately determine occurrence rates. As part of a systematic modelling effort in the context of a >10-yr retrospective analysis of MOA’s survey observations to build an extended MOA statistical sample, we analyse the light curve of the planetary microlensing event MOA-2014-BLG-472. This event provides weak constraints on the physical parameters of the lens, as a result of a planetary anomaly occurring at low magnification in the light curve. We use a Bayesian analysis to estimate the properties of the planet, based on a refined Galactic model and the assumption that all Milky Way’s stars have an equal planet-hosting probability. We find that a lens consisting of a 1.9(+2.2,−1.2)M(J) giant planet orbiting a 0.31(+0.36,−0.19)Mꙩ host at a projected separation of 0.75±0.24au is consistent with the observations and is most likely, based on the Galactic priors. The lens most probably lies in the Galactic bulge, at 7.2(+0.6,−1.7)kpc from Earth. The accurate measurement of the measured planet-to-host star mass ratio will be included in the next statistical analysis of cold planet demography detected by microlensing.

Clément Ranc↗

Optial Experiments and Model Validation of Perturbed Starshade Designs

Starshades are a leading technology to enable the direct detection and spectroscopic characterization of Earth- like exoplanets. Critical starshade technologies are currently being advanced through the S5 Project and at the Princeton starshade testbed. We report on the status of Milestone 2 of the S5 Project, optical model validation. We present results from optical experiments of starshades with intentional perturbations built into their design. These perturbations are representative of the type of perturbations possible in a flight design and serve as points of validation for dffraction models and error budgets. We show experimental results for two perturbed shapes, a mask with all petals shifted radially outward by 5 um and a mask with shallow sine waves built into two petals. We compare these data to outputs of the optical model and demonstrate better than 25% agreement. We also present images taken in crossed polarized light and use those data to constrain physical parameters of the optical edge. Bringing in previously obtained results for other perturbed shapes, we show an agreement between experiment and model of better than 25% and argue that this satisfies the Milestone 2 criteria.

Galvin, Michael↗

Optical probes of atomic and molecular decay processes.

The study of molecular photoionization and photodissociation dynamics provides insight into the intramolecular mechanisms by which energy and angular momentum are exchanged and redistributed among the internal degrees of freedom of highly excited molecules and, more specifically, into the mechanisms that determine the decay pathways and resulting product-state distributions for the excited molecules. These mechanisms lie at the heart of one of the principal subjects of chemistry, that is, understanding and controlling the factors that govern the making and breaking of chemical bonds. The objective of this experimental research program is to elucidate these fundamental mechanisms and to provide useful prototypes for the development of a general qualitative understanding of their ramifications. In this program, the primary focus is on resonant processes in the ionization and dissociation continua, that is, on autoionization and predissociation. These processes are studied as a function of the electronic, vibrational, and rotational quantum numbers of the resonances, allowing a better understanding of their fundamental mechanisms. In the past three years, the primary emphasis of this experimental program has been on understanding the process of vibrational autoionization in Rydberg states of small polyatomic molecules. Vibrational autoionization corresponds to the decay of resonances above the ionization threshold into the continuum through the conversion of vibrational energy into electronic/translational energy of the highly excited/ejected electron. In polyatomic molecules, I am particularly interested in determining how this process depends on both the specific normal vibrational modes involved in the process and the electronic character of the resonances. In this program, the experimental approach relies on laser-based, double-resonance techniques to prepare the selected excited states in the molecules of interest, and on a variety of detection techniques to characterize both the photoexcitation and subsequent decay processes. These techniques include mass spectrometry, dispersive and threshold photoelectron spectroscopy, laser-induced fluorescence, fluorescence-dip spectroscopy, and laser-induced grating spectroscopy. While the instrumentation is currently available for each of these techniques, two instruments deserve special mention. First, a high-resolution magnetic-bottle electron spectrometer has been developed that is equipped with a pulsed, skimmed molecular beam source. This instrument is capable of {approx}3-4 meV resolution in the electron kinetic energy while providing a collection efficiency of {approx}50%. Second, a time-of-flight mass spectrometer has been constructed with a similar molecular beam source. This instrument is currently being adapted to allow both ion- and electron-imaging studies. A typical experimental study is performed in three steps. First, resonant one-color multiphoton ionization is used to map out the transition between the ground state of the molecule of interest and the low-lying excited state to be used as an intermediate in the double-resonance process. The lasers used in these studies are Nd:YAG-pumped dye lasers with {approx}5 ns pulse durations. In general, this pump transition corresponds to a one- or two-photon process, and the laser output is frequency doubled, tripled, or mixed to generate light in the region of interest. In molecules such as ammonia and aniline, the pump transitions of interest are well characterized, allowing the unambiguous choice of pump transitions that access levels with the rovibronic character of interest. In other cases, the spectroscopy of the pump transition must be analyzed before it can be useful for the double-resonance experiments. In the second step, the pump laser is fixed on the pump transition of interest and a second laser is used to probe transitions from the upper state of the pump transition to the autoionizing or predissociating resonances in the region of interest. The double-resonance spectrum is recorded by scanning the second laser and monitoring either the mass-selected ion signal or the total photoelectron signal resulting from the two-color process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrasonic Phased Array Evaluation of Control Rod Drive Mechanism (CRDM) Nozzle Interference Fit and Weld Region

Ultrasonic phased array data were collected on a removed-from-service CRDM nozzle specimen to assess a previously reported leak path. First a mock-up CRDM specimen was evaluated that contained two 0.076-mm (3.0-mil) interference fit regions formed from an actual Inconel CRDM tube and two 152.4-mm (6.0-in.) thick carbon steel blocks. One interference fit region has a series of precision crafted electric discharge machining (EDM) notches at various lengths, widths, depths, and spatial separations for establishing probe sensitivity, resolution and calibration. The other interference fit has zones of boric acid (crystal form) spaced periodically between the tube and block to represent an actively leaking CRDM nozzle assembly in the field. Ultrasonic phased-array evaluations were conducted using an immersion 8-element annular 5.0-MHz probe from the tube inner diameter (ID). A variety of focal laws were employed to evaluate the interference fit regions and J grove weld, where applicable. Responses from the mock-up specimen were evaluated to determine detection limits and characterization ability as well as contrast the ultrasonic response differences with the presence of boric acid in the fit region. Nozzle 63, from the North Anna Unit-2 nuclear power plant, was evaluated to assess leakage path(s) and was destructively dismantled to allow a visual verification of the leak path(s).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Comparison of an Ultrasonic Phased Array Evaluation with Destructive Analysis of a Documented Leak Path in a Nozzle Removed from Service

Non-destructive and destructive testing methods were employed to evaluate a documented boric acid leakage path through an Alloy 600 control rod drive mechanism (CRDM) penetration from the North Anna Unit 2 reactor pressure vessel head that was removed from service in 2002. A previous ultrasonic in-service-inspection (ISI) conducted by industry prior to the head removal, identified a probable leakage path in Nozzle 63 located in the interference fit between the penetration tube and the vessel head. In this current examination, Nozzle 63 was examined using phased array (PA) ultrasonic testing with a 5.0-MHz, eight-element annular array; immersion data were acquired from the nozzle inner diameter (ID) surface. A variety of focal laws were employed to evaluate the signal responses from the interference fit region. These responses were compared to responses obtained from a mockup specimen that was used to determine detection limits and characterization capabilities for wastage and boric acid presence in the interference fit region. Nozzle 63 was destructively examined after the completion of the ultrasonic nondestructive evaluation (NDE) to visually assess the leak paths. These destructive and nondestructive results compared favorably

CRDM↗

Discovery, detection and use of biomarkers

Provided herein are systems for and methods of capturing, detecting, quantifying, and characterizing target moieties that are characterized by having a lipophilic portion of sufficient size and chemical composition whereby the target moiety inserts (or partitions) into a lipid assembly. Examples of such assays employ synthetic lipid constructs such as supported bilayers which are used to capture target moieties; other example assays exploit the natural absorption of compounds into natural lipid constructs such as HDL or LDL particles or cell membranes to capture target moieties. In specific embodiments, the target moieties are bacterial pathogen associated molecular pattern (PAMP) molecules or compounds not yet identified as PAMP molecules. Also provided are methods of determining PAMP molecule fingerprints and profiles that are linked to (indicative of) bacterial infection, disease states or progression, development of antibiotic resistance, and so forth, as well as these fingerprints, profiles and methods of using them.

59 BASIC BIOLOGICAL SCIENCES↗

Readout of Large Capacitance SiPMs by Weak Coupling to Charge Sensitive Amplifier

Large area and large capacitance silicon photomultiplier (SiPM) arrays are employed to collect scintillation light in noble liquid time projection chambers (TPC) such as DarkSide, nEXO, MEGII, protoDUNE and DUNE. Light readout using ASICs designed for operation in noble liquids is a solution for large meter-scale photon detectors. However, conventional readout requires a high voltage decoupling capacitor larger than SiPM capacitance (in the range of tens of nF) to achieve full charge transfer to the preamplifier. Here, we demonstrate a readout concept by weakly coupling (via a capacitor lower by an order of magnitude than SiPM capacitance) to a charge sensitive amplifier, LArASIC in this case, without any loss in the signal to noise ratio (S/N). The single-photoelectron detection, signal-to-noise ratio, timing resolution, and coincidence detection are experimentally characterized.

47 OTHER INSTRUMENTATION↗

Measuring alpha eigenvalue of a subcritical system by a intense pulsed neutron source

Intense-Pulsed-Neutron-Source (IPNS) technique is a new approach to measure the subcriticality of a reactor system, which has been theoretically analyzed by us while not been verified in experiment in other reference. In INPS technique the reactivity is derived via the system response to a prompt pulsed neutron source. The method utilizes very intense neutron pulses (about 1010 neutrons/pulse) with the duration ranging from 10 ns to 100 ns, which are generated by the dense plasma focus (DPF) device filled with pure DT mixture as the working gas. The neutron pulse in high intensity provides the opportunity to measure the signal using a scintillator and a photo-multiplier tube (PMT) (the intense pulse radiation measure method) with the flight distance of only twenty centimeters. The attenuation of the dense plasma focus device must be faster than the subcritical system so that the attenuation of the system can be researched. In this paper, after a neutron pulse is injected into the subcritical reactor, the subcriticality is determined by measuring the instantaneous characteristics of the leaking reactor neutron. The Monte Carlo analysis shows that, with the linear arrangement of the dense plasma focus, the subcritical system and the detector, the signal-to-noise ratio at the measure point meets the investigate requirement, in which the 14 MeV neutrons are attenuated by the subcritical system. The detector is close with the subcritical system to reduce the influence of the outer background and the spread of time-of-flight of the neutrons. The measure system utilizing gated detection technology is characterized with fast attenuation time and large linear current, the a value obtained with this method is 2.05 μs{sup -1} while the measurements using the {sup 252}Cf stochastic pulsed source method and the Rossi-a method were 2.18μs{sup -1} and 2.16μs{sup -1}.It showed that the measured result obtained with dense plasma focus instantaneous pulsed source is consistent with those obtained with the other two traditional methods. This new method utilized only a single-shot pulse to determine the a value of the reactor system. Therefore, this quick measure method is recommendable. The influence caused by energy response of the detector should been taken into account since the measured result reflects the time behavior of group particle. The influence is discussed preliminarily in this paper. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of Robotic Multisensor Inspection System for Used Nuclear Fuel Canisters

Dry storage of used nuclear fuel is an integral part of the fuel cycle and methods to inspect the canisters that confine the used fuel rods are being established. The challenges for inspection systems include geometric constraints, elevated temperature, and radiation. A novel robotic inspection system focusing on stress corrosion cracking capable of in-situ surface composition characterization and crack detection is under development. The delivery system, laser induced breakdown spectroscopy for surface composition, and ultrasonic guided waves for crack detection are summarized herein. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards an Empirically Based Parametric Explosion Spectral Model

Small underground nuclear explosions need to be confidently detected, identified, and characterized in regions of the world where they have never before been tested. The focus of our work is on the local and regional distances (< 2000 km) and phases (Pn, Pg, Sn, Lg) necessary to see small explosions. We are developing a parametric model of the nuclear explosion seismic source spectrum that is compatible with the earthquake-based geometrical spreading and attenuation models developed using the Magnitude Distance Amplitude Correction (MDAC) techniques (Walter and Taylor, 2002). The explosion parametric model will be particularly important in regions without any prior explosion data for calibration. The model is being developed using the available body of seismic data at local and regional distances for past nuclear explosions at foreign and domestic test sites. Parametric modeling is a simple and practical approach for widespread monitoring applications, prior to the capability to carry out fully deterministic modeling. The achievable goal of our parametric model development is to be able to predict observed local and regional distance seismic amplitudes for event identification and yield determination in regions with incomplete or no prior history of underground nuclear testing. The relationship between the parametric equations and the geologic and containment conditions will assist in our physical understanding of the nuclear explosion source.

58 GEOSCIENCES↗

Sensor Networks for Detecting Toxic Releases in Buildings

Sudden releases of a toxic agent indoors can cause immediate and long-term harm to occupants. In order to protect building occupants from such threats, it is necessary to have a robust air monitoring system that can detect, locate, and characterize accidental or deliberate toxic gas releases. However, developing such a system is complicated by several requirements, in particular the need to operate in real-time. This task is further complicated when monitoring sensors are prone to false positive and false negative readings. We report on work towards developing an indoor monitoring system that is robust even in the presence of poor quality sensor data. The algorithm, named BASSET, combines deterministic modeling and Bayesian statistics to join prior knowledge of the contaminant transport in the building with real-time sensor information. We evaluate BASSET across several data sets, which vary in sensor characteristics such as accuracy, response time, and trigger level. Our results suggest that optimal designs are not always intuitive. For example, a network comprised of slower but more accurate sensors may locate the contaminant source more quickly than a network with faster but less accurate sensors.

54 ENVIRONMENTAL SCIENCES↗

Preparation and Characterization Methods of Thin Layer Samples for Standoff Detection

Detection of analytes deposited on surfaces is crucial for many applications: Development of methods to prepare thin layers (e.g. ~5 to 100 µm) is important for both system design and field studies. In this work, solid and liquid analytes were deposited on painted and bare substrates including aluminum, glass, plastic, and concrete using an ExactaCoat ultrasonic spray coater. Laboratory hemispherical reflectance (HRF) spectra were collected for samples with different layer thicknesses so as to characterize both the composition and layer thickness. Preliminary results demonstrate that to prepare homogenous layers on surfaces, parameters such as substrate type, analyte solubility, vapor pressure, paint color, surface porosity, and surface roughness are all important. Liquid chemicals posed several issues during deposition: Diisopropyl methyl phosphonate evaporated from surfaces more quickly than the other chemicals and was thus not detected in the HRF experiments. Less volatile liquids, such as tributylphosphate, remained on the surface for the duration of the test, but a uniform layer thickness could not be obtained as the liquid pooled to one side when mounted at an angle. The deposition of solids (e.g., acetaminophen, caffeine and methylphosphonic acid) from volatile solvents such as chloroform also proved problematic due to streaking caused by rapid solvent evaporation. Solids deposited from ethanol, however, worked well on bare substrates. For most samples plotting the integrated infrared band strength vs. surface thicknesses showed a linear relationship, confirming that the surface loading can be controlled by programming the concentration and the number of passes on the ultrasonic sprayer.

Thin layer, deposition, infrared standoff, Hemisph↗

The Future of Exoplanet Direct Detection

Diffraction fundamentally limits our ability to image and characterize exoplanets. Currant and planned coronagraphic searches for exoplanets are making incredible strides but are fundamentally limited by the inner working angle of a few λ/D. Some crucial topics, such as demographics of exoplanets within the first 50 Myr and the infrared characterization of terrestrial planets, are beyond the reach of the single aperture angular resolution for the foreseeable future. Interferometry offers some advantages in exoplanet detection and characterization and we explore in this white paper some of the potential scientific breakthroughs possible. We demonstrate here that investments in "exoplanet interferometry" could open up new possibilities for speckle suppression through spatial coherence, a giant boost in astrometric precision for determining exoplanet orbits, ability to take a census of young giant exoplanets (clusters <50 Myr age), and an unrivaled potential for infrared nulling from space to detect terrestrial planets and search for atmospheric biomarkers. All signs point to an exciting future for exoplanets and interferometers, albeit a promise that will take decades to fulfill.

John Monnier↗

Time-resolved single-photon detection module based on silicon photomultiplier: A novel building block for time-correlated measurement systems

We present the design and preliminary characterization of the first detection module based on Silicon Photomultiplier (SiPM) tailored for single-photon timing applications. The aim of this work is to demonstrate, thanks to the design of a suitable module, the possibility to easily exploit SiPM in many applications as an interesting detector featuring large active area, similarly to photomultipliers tubes, but keeping the advantages of solid state detectors (high quantum efficiency, low cost, compactness, robustness, low bias voltage, and insensitiveness to magnetic field). The module integrates a cooled SiPM with a total photosensitive area of 1 mm{sup 2} together with the suitable avalanche signal read-out circuit, the signal conditioning, the biasing electronics, and a Peltier cooler driver for thermal stabilization. It is able to extract the single-photon timing information with resolution better than 100 ps full-width at half maximum. We verified the effective stabilization in response to external thermal perturbations, thus proving the complete insensitivity of the module to environment temperature variations, which represents a fundamental parameter to profitably use the instrument for real-field applications. We also characterized the single-photon timing resolution, the background noise due to both primary dark count generation and afterpulsing, the single-photon detection efficiency, and the instrument response function shape. The proposed module can become a reliable and cost-effective building block for time-correlated single-photon counting instruments in applications requiring high collection capability of isotropic light and detection efficiency (e.g., fluorescence decay measurements or time-domain diffuse optics systems).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

"COMBUSTION DEVELOPMENT OF A HIGH EFFICIENCY DIESEL MICRO PILOT NATURAL GAS ENGINE."

Dual fuel engine operation with premixed natural gas as the main fuel and diesel pilot ignition has been gaining interest among research and industry as natural gas is among the most promising existing alternative fuels. The dual fuel engine performance has been shown to equal and sometimes, depending on operating conditions, better the performance and efficiency of the diesel engine. Along with its advantages on the combustion high efficiency, diesel-like performance, and emissions of NOx and particulate matter reduction, some disadvantages are brought by the application of such operation. At light load conditions, there is an increase in CO and HC emissions, low fuel efficiency and combustion stability. While operating at higher loads, the dual fuel engine performance showed to be limited by combustion knock. This effectively reduces the maximum break mean effective pressure (BMEP) the engine can output when compared to a diesel engine. Although combustion knock is well defined in SI and diesel engines, dual fuel knock characterization still needs more investigation. This project centers on developing a fuel system for a diesel engine conversion to dual fuel to deliver high load and high efficiency. The selected engine has been converted to the dual fuel operation and dual fuel combustion has been demonstrated. After achieving the project goal of a high load and high efficiency dual fuel engine, the combustion knock in dual fuel operation will be characterized and a method for detection and intensity calculation will be modeled. The characterization will also be compared to spark ignition (SI) and reactivity-controlled compression ignition (RCCI) operating engines.

03 NATURAL GAS↗

A shallow underground laboratory for low-background radiation measurements and materials development

Pacific Northwest National Laboratory recently commissioned a new shallow underground laboratory, located at a depth of approximately 30 meters-water-equivalent. This new addition to the small class of radiation measurement laboratories located at modest underground depths houses the latest generation of custom-made, high-efficiency, low-background gamma-ray spectrometers and gas proportional counters. This paper describes the unique capabilities present in the shallow underground laboratory; these include large-scale ultra-pure materials production and a suite of radiation detection systems. Reported data characterize the degree of background reduction achieved through a combination of underground location, graded shielding, and rejection of cosmic-ray events. We conclude by presenting measurement targets and future opportunities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OSSOS. IX. Two Objects in Neptune's 9:1 Resonance—Implications for Resonance Sticking in the Scattering Population

We discuss the detection in the Outer Solar System Origins Survey (OSSOS) of two objects in Neptune’s distant 9:1 mean motion resonance at semimajor axis a ≈ 130 au. Both objects are securely resonant on 10 Myr timescales, with one securely in the 9:1 resonance’s leading asymmetric libration island and the other in either the symmetric or trailing asymmetric island. These objects are the largest semimajor axis objects with secure resonant classifications, and their detection in a carefully characterized survey allows for the first robust resonance population estimate beyond 100 au. The detection of these objects implies a 9:1 resonance population of 1.1 × 10{sup 4} objects with H {sub r} < 8.66 (D ≳ 100 km) on similar orbits (95% confidence range of ∼(0.4–3) × 10{sup 4}). Integrations over 4 Gyr of an ensemble of clones spanning these objects’ orbit-fit uncertainties reveal that they both have median resonance occupation timescales of ∼1 Gyr. These timescales are consistent with the hypothesis that these objects originate in the scattering population but became transiently stuck to Neptune’s 9:1 resonance within the last ∼1 Gyr of solar system evolution. Based on simulations of a model of the current scattering population, we estimate the expected resonance sticking population in the 9:1 resonance to be 1000–4500 objects with H {sub r} < 8.66; this is marginally consistent with the OSSOS 9:1 population estimate. We conclude that resonance sticking is a plausible explanation for the observed 9:1 population, but we also discuss the possibility of a primordial 9:1 population, which would have interesting implications for the Kuiper Belt’s dynamical history.

79 ASTRONOMY AND ASTROPHYSICS↗

Device and method for locating a radiation emitting source via angular dependence using a single detection crystal

A device for sensing, locating, and characterizing a radiation emitting source, including: a detection crystal having dimensions great enough such that regional differences in radiation response are generated in the detection crystal by radiation impinging on one or more surfaces of the detection crystal; and a plurality of detectors one or more of coupled to and disposed on a plurality of surfaces of the detection crystal operable for detecting the regional differences in radiation response generated in the detection crystal by the radiation impinging on the one or more surfaces of the detection crystal.

36 MATERIALS SCIENCE↗