Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Qualification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Fracture control procedures for aircraft structural integrity

The application of applied fracture mechanics in the design, analysis, and qualification of aircraft structural systems are reviewed. Recent service experiences are cited. Current trends in high-strength materials application are reviewed with particular emphasis on the manner in which fracture toughness and structural efficiency may affect the material selection process. General fracture control procedures are reviewed in depth with specific reference to the impact of inspectability, structural arrangement, and material on proposed analysis requirements for safe crack growth. The relative impact on allowable design stress is indicated by example. Design criteria, material, and analysis requirements for implementation of fracture control procedures are reviewed together with limitations in current available data techniques. A summary of items which require further study and attention is presented.

Wood, H. A.↗

Performance Optimization of Storable Bipropellant Engines to Fully Exploit Advanced Material Technologies

This paper summarizes the work performed to dale on the NASA Cycle 3A Advanced Chemical Propulsion Technology Program. The primary goals of the program are to design, fabricate, and test high performance bipropellant engines using iridium/rhenium chamber technology to obtain 335 seconds specific impulse with nitrogen tetroxide/hydrazine propellants and 330 seconds specific impulse with nitrogen tetroxide/monomethylhydrazine propellants. Aerojet has successfully completed the Base Period of this program, wherein (1) mission and system studies have been performed to verify system performance benefits and to determine engine physical and operating parameters, (2) preliminary chamber and nozzle designs have been completed and a chamber supplier has been downselected, (3) high temperature, high pressure off-nominal hot fire testing of an existing state-of-the-art high performance bipropellant engine has been completed, and (4) thermal and performance data from the engine test have been correlated with new thermal models to enable design of the new engine injector and injector/chamber interface. In the next phase of the program, Aerojet will complete design, fabrication, and test of the nitrogen tetroxide/hydrazine engine to demonstrate 335 seconds specific impulse, and also investigate improved technologies for iridium/rhenium chamber fabrication. Achievement of the NRA goals will significantly benefit NASA interplanetary missions and other government and commercial opportunities by enabling reduced launch weight and/or increased payload. At the conclusion of the program, the objective is to have an engine ready for final design and qualification for a specific science mission or commercial application. The program also constitutes a stepping stone to future, development, such as higher pressure pump-fed in-space storable engines.

Miller, Scott↗

The Additive Manufacturing Moment Measure (AM3) Approach to Predictions of Solid Cooling Rate and Time Above Melt

Qualification of a laser powder bed fusion additive manufacturing (LPBF-AM) process requires knowledge of the multi-scale material physics during the process, per part. As the LPBF-AM build occurs, each moment is influenced by the process history. Knowledge of the build sequence can be used to generate a discretized time-space-condition point field that when coupled with a nearest neighbors’ calculation results in a generalized and fully parallel process model computation. This GPU accelerated approach was developed for part-scale analysis of build files along with in-situ process monitoring sensor data and is termed the “Additive Manufacturing Moment Measure” (AM3). The AM3 approach will be presented and then used to evaluate an AM Bench relevant geometry with synchronized in-situ process data, ex-situ nondestructive evaluation, and optical microscopy observations. These comparisons permit a better understanding of how the process actions can affect the LPBF-AM build quality and the signals generated during in-situ process monitoring.

Additive Manufacturing↗

A New Approach in Force-Limited Vibration Testing of Flight Hardware

The force-limited vibration test approaches discussed in NASA-7004C were developed to reduce overtesting associated with base shake vibration tests of aerospace hardware where the interface responses are excited coherently. This handbook outlines several different methods of specifying the force limits. The rationale for force limiting is based on the disparity between the impedances of typical aerospace mounting structures and the large impedances of vibration test shakers when the interfaces in general are coherently excited. Among these approaches, the semi-empirical method is presently the most widely used method to derive the force limits. The inclusion of the incoherent excitation of the aerospace structures at mounting interfaces has not been accounted for in the past and provides the basis for more realistic force limits for qualifying the hardware using shaker testing. In this paper current methods for defining the force limiting specifications discussed in the NASA handbook are reviewed using data from a series of acoustic and vibration tests. A new approach based on considering the incoherent excitation of the structural mounting interfaces using acoustic test data is also discussed. It is believed that the new approach provides much more realistic force limits that may further remove conservatism inherent in shaker vibration testing not accounted for by methods discussed in the NASA handbook. A discussion on using FEM/BEM analysis to obtain realistic force limits for flight hardware is provided.

force limiting responses↗

Viking Mars hydrazine terminal descent engine thermal design considerations

A description is given of some of the more significant thermal design considerations employed in the development and qualification of the monopropellant hydrazine terminal descent engines on the Viking Mars lander spacecraft. The terminal descent engine operates in a blowdown and throttling mode, which results in an operating thrust range of 638 to 90 lbf. Martian entry thermal design boundary conditions are described, along with resulting radiative and conductive engine thermal isolation hardware. Test results are presented, showing engine thermal design performance as compared with specified requirements. General engine materials of construction are described, along with Hastelloy B shell structural characteristics, which were extended to 2000 F by test and are compared with limited existing MIL-HDBK-5 data. Subscale test results are presented, showing the maximum catalyst bed cylinder design temperature of 1970 F. Test results also are presented, showing local reactor internal convective heat-transfer coefficients. Such data are unique, since the engine employs a completely radial flow catalyst bed design. This design approach is the first of its kind in the monopropellant hydrazine gas generator field to be flight qualified.

Cunningham, C. R.↗

The Viking parachute qualification test technique.

The parachute system for NASA's Viking '75 Mars lander was flight qualified in four high-altitude flight tests at the White Sands Missile range (WSMR). A balloon system lifted a full-scale simulated Viking spacecraft to an altitude where a varying number of rocket motors were used to propel the high drag, lifting test vehicle to test conditions which would simulate the range of entry conditions expected at Mars. A ground-commanded cold gas pointing system located on the balloon system provided powered vehicle azimuth control to insure that the flight trajectory remained within the WSMR boundaries. A unique ground-based computer-radar system was employed to monitor inflight performance of the powered vehicle and insure that command ignition of the parachute mortar occurred at the required test conditions of Mach number and dynamic pressure. Performance data were obtained from cameras, telemetry, and radar.

Raper, J. L.↗

Liquid secondary waste: Waste form formulation and qualification

The Hanford Site Effluent Treatment Facility (ETF) currently treats aqueous waste streams generated during site cleanup activities. When the Hanford Tank Waste Treatment and Immobilization Plant (WTP) begins operations, including Direct Feed Low Activity Waste (DFLAW) vitrification, a liquid secondary waste (LSW) stream from the WTP will need to be treated. The volume of effluent for treatment at the ETF will increase significantly. The powdered salt waste form produced by the ETF will be replaced by a stabilized solidified waste form for disposal in Hanford’s Integrated Disposal Facility (IDF). Washington River Protection Solutions is implementing a Secondary Liquid Waste Immobilization Technology Development Plan to address the technology needs for a waste form and solidification process to treat the increased volume of waste planned for disposal at the IDF. Waste form testing to support this plan is composed of work in the near term to provide data as input to a performance assessment (PA) for Hanford’s IDF. In 2015, three Hanford Liquid Secondary Waste simulants were developed based on existing and projected waste streams. Using these waste simulants, fourteen mixes of Hanford Liquid Secondary Waste were prepared and tested varying the waste simulant, the water-to-dry materials ratio, and the dry materials blend composition.1 In FY16, testing was performed using a simulant of the EMF process condensate blended with the caustic scrubber—from the Low Activity Waste (LAW) melter—, processed through the ETF. The initial EMF-16 simulant will be based on modeling efforts performed to determine the mass balance of the ETF for the DFLAW.2 The compressive strength of all of the mixes exceeded the target of 3.4 MPa (500 psi) to meet the requirements identified as potential IDF Waste Acceptance Criteria in Table 1 of the Secondary Liquid Waste Immobilization Technology Development Plan.3 The hydraulic properties of the waste forms tested (hydraulic conductivity and water characteristic curves) were comparable to the properties measured on the Savannah River Site (SRS) Saltstone waste form. Future testing should include efforts to first; 1) determine the rate and amount of ammonia released during each unit operation of the treatment process to determine if additional ammonia management is required, then; 2) reduce the ammonia content of the ETF concentrated brine prior to solidification, making the waste more amenable to grouting, or 3) manage the release of ammonia during production and ongoing release during storage of the waste form, or 4) develop a lower pH process/waste form thereby precluding ammonia release.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BISON analyses of TRISO fuel performance, its dependence on time-at-temperature, and possible implications for fuel design and qualification

The Advanced Gas Reactor Fuel Development and Qualification (AGR) program has established a substantial technical foundation to support private entry into the U.S. high-temperature gas-cooled reactor market. However, emerging tristructural isotropic (TRISO)-fueled reactor applications include small modular reactors and microreactors with longer fuel residence times, which may expose fuels to higher time-at-temperature (TAT) values than were explored by the AGR program. Increased TAT could affect diffusive and thermomechanical behaviors such as Pd penetration, fission gas release, creep, and fission product transport. In this work, we applied multiscale best-estimate BISON fuel performance modeling to assess these effects within a representative design space based on the AGR-5/6/7 experiment and analyzed trends in predicted particle and compact fuel performance metrics with possible implications for near-term fuel design and qualification. BISON unambiguously predicted that TRISO fuel performance is sensitive to TAT. Increasing TAT was not predicted to increase the magnitude of failure-inducing tangential stresses in particle coating layers. Predictions obtained using a mechanistic model for Pd penetration indicated that penetration depth does not depend strongly on TAT. While these observations suggest that AGR testing provides a conservative upper bound for the steady-state operation of TRISO particles at lower powers and higher residence times, BISON also predicted that the release of poorly retained Ag would increase with TAT. Because these analyses applied models to extrapolate beyond the available experimental data, the authors recommend performing targeted experiments to confirm these predictions. Nevertheless, these predictions may provide reactor developers with enough confidence to make near-term design decisions associated with the potential fuel performance trade-offs of increasing TAT.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The calorimeter of the Mu2e experiment at Fermilab

Here, the Mu2e experiment at Fermilab looks for Charged Lepton Flavor Violation (CLFV) improving by 4 orders of magnitude the current experimental sensitivity for the muon to electron conversion in a muonic atom. A positive signal could not be explained in the framework of the current Standard Model of particle interactions and therefore would be a clear indication of new physics. In 3 years of data taking, Mu2e is expected to observe less than one background event mimicking the electron coming from muon conversion. Achieving such a level of background suppression requires a deep knowledge of the experimental apparatus: a straw tube tracker, measuring the electron momentum and time, a cosmic ray veto system rejecting most of cosmic ray background and a pure CsI crystal calorimeter, that will measure time of flight, energy and impact position of the converted electron. The calorimeter has to operate in a harsh radiation environment, in a 10 -4 Torr vacuum and inside a 1 T magnetic field. The results of the first qualification tests of the calorimeter components are reported together with the energy and time performances expected from the simulation and measured in beam tests of a small scale prototype.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-A-207B-00: Shear-Wave Imaging and a QIBA US Biomarker Update

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

Deconvoluting sources of variability in aerosol jet printing using light scattering measurements

Aerosol jet printing (AJP) is a digital additive manufacturing technique for hybrid and conformal electronics, where its contactless deposition readily enables patterning over 3D surface topography. However, the complexity of aerosol transport physics makes deposition rate sensitive to process variability, hindering widespread industry adoption. Light scattering measurements have recently been demonstrated as a capable tool for measuring deposition rate in real time, enabling closed-loop control and in-situ qualification frameworks. These inline optical measurements present further opportunity as a diagnostic tool to understand the effects of secondary process parameters affecting vapor–liquid equilibrium and heat and mass transport during deposition. Downstream of the optical measurement cell, changing the sheath gas flow rate, increasing temperature via an inline heater, and adding solvent vapor via a sheath gas bubbler were observed to alter drying physics during sheath-collimation, and thereby impaction efficiency. Further upstream, the introduction of solvent vapor via a carrier gas bubbler and liquid build-up in the printhead were seen to affect the quantitative relationship between the light scattering data and the true deposition rate. Using this information, tightened controls of meaningful secondary parameters were implemented to improve the batch-to-batch consistency for printing a dielectric ink. In addition to advancing AJP process reliability for production, this work demonstrates the capability of inline optical measurements to provide insight into process physics and deconvolute competing mechanisms that underly variability.

additive manufacturing↗

Progress Report on Graphite-Salt Intrusion Studies

The document reports on the design, construction, testing and initial operation of the ORNL graphite intrusion system with pressurized molten salts. This technical memorandum is responsive to work package AT-20OR04060203, “Graphite-Salt Studies” —ORNL”, and fulfills Milestone M3AT20OR040602035 “Report on graphite-salt intrusion studies”.The report outlines the procedure of graphite intrusion experiments, which follows the ASTM standard guidance, and the procedures of other characterization measurements of graphite physical properties, also based on ASTM standard methods. A set of 12 graphite grades of various origin and properties went through preliminary characterizations, and six of them were further selected for intrusion experiments with molten FLiNaK. The results are discussed in the context of graphite physical properties and are compared with a several results from literature. The correlation between molten salt impregnation and mercury intrusion, first proposed by MSRE scientists, is discussed in detail. Pending collection of more data, the mercury intrusion porosimetry technique may possibly be used as a rapid method for screening and down selection of graphite grades with extremely low salt intrusion, as required for operation in molten salt reactors. This new system will generate data non only on intrusion behavior, but will also generate a wide range of salt- impregnated graphite samples that will be further analyzed with advanced characterization techniques for better understanding of the effect of salt intrusion on the properties of nuclear graphite. It expected that these results and future results obtained with this system will help advance our understanding of the factors controlling the extent of salt penetration in graphite and of the relationship with intrinsic structural properties of various grades. Together, correlating direct measurements results and graphite structural properties should allow development of a predictable model that could be used for selection and qualification of optimal graphite grades, tailored to design operation conditions and molten salt properties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Qualification test of the Ross Double Planetary Mixer

This test report describes the qualification test of the Ross Double Planetary Mixer used to mix room temperature vulcanized (RTV) silicone (Dow Corning 90-006-2) for the redesigned solid rocket motor (RSRM) nozzle joints. Testing was completed 18 June 1993 in the M-113A Nozzle Fabrication Facility at Thiokol Corporation, Space Operations, Brigham City, Utah. The Ross mixer provides better mixing and better control on temperature and humidity, resulting in better quality RTV and a longer usable pot life. The test began on 3 May 1993 and was stopped due to operator error during the tensile strength and elongation testing. Specimens were ruined without gathering any useful data. A 'no test' was declared, the problem was remedied, and the test was re-run with MSFC approval. The test was run and all pass/fail criteria were met, most with a considerable margin. The Ross Double Planetary Mixer met all certification objectives and is recommended for immediate use for mixing RTV silicone for RSRM nozzle joints.

Lueders, Kurt F.↗

NASA's Space Launch System Takes Shape

Major hardware and software for NASA's Space Launch System (SLS) began rolling off assembly lines in 2016, setting the stage for critical testing in 2017 and the launch of a major new capability for deep space human exploration. SLS continues to pursue a 2018 first launch of Exploration Mission 1 (EM-1). At NASA's Michoud Assembly Facility near New Orleans, LA, Boeing completed welding of structural test and flight liquid hydrogen tanks, and engine sections. Test stands for core stage structural tests at NASA's Marshall Space Flight Center, Huntsville, AL. neared completion. The B2 test stand at NASA's Stennis Space Center, MS, completed major structural renovation to support core stage green run testing in 2018. Orbital ATK successfully test fired its second qualification solid rocket motor in the Utah desert and began casting the motor segments for EM-1. Aerojet Rocketdyne completed its series of test firings to adapt the heritage RS-25 engine to SLS performance requirements. Production is under way on the first five new engine controllers. NASA also signed a contract with Aerojet Rocketdyne for propulsion of the RL10 engines for the Exploration Upper Stage. United Launch Alliance delivered the structural test article for the Interim Cryogenic Propulsion Stage to MSFC for tests and construction was under way on the flight stage. Flight software testing at MSFC, including power quality and command and data handling, was completed. Substantial progress is planned for 2017. Liquid oxygen tank production will be completed at Michoud. Structural testing at Marshall will get under way. RS-25 hotfire testing will verify the new engine controllers. Core stage horizontal integration will begin. The core stage pathfinder mockup will arrive at the B2 test stand for fit checks and tests. EUS will complete preliminary design review. This paper will discuss the technical and programmatic successes and challenges of 2016 and look ahead to plans for 2017.

Askins, Bruce↗

Overview of Integrated Random Vibration Testing of the NASA Orion Crew Survival Suit

The launch ascent and abort random vibration environments from NASA’s Orion spacecraft drove the need to test the NASA Orion Crew Survival Suit as an integrated system with exposure to the design levels. In order to properly characterize component responses, a series of integrated tests were designed to incorporate the interaction between a crew member, suit, seat, and the attenuation system. The first Development Test (2017) included human subjects, and was performed with early development seat and suit components, and low level inputs. It provided a baseline for frequency response and behavior of the integrated system. The next two tests, Development Test (2019) and Qualification Test (2020), used manikin surrogates to represent the crew member and increasing levels of component hardware fidelity in order to test to higher input levels. Testing was performed at NASA Johnson Space Center (JSC) and Kennedy Space Center (KSC) Vibration Labs and provided the input levels required to represent the ascent and abort vehicle profiles as well as recorded component response behavior from accelerometer instrumentation and high speed cameras. Inspection of the suit and related components showed that for all seat orientations, and input environments, no damage occurred. Additional pre and post-test checks confirmed the functionality of all suited hardware. Response data of the suited components generally showed heavy attenuation across most of the tested frequency range. Transmissibility plots showed some amplification of components at lower frequency ranges. Overall this series of integrated tests showed that 1) the use of surrogate manikins in the tests were adequate for representing crew in a vibration environment, 2) full vibration levels for ascent and abort were heavily attenuated in the suit components and were non-damaging, and 3) the suit and related components are qualified for the Orion random vibration environments.

Jeffrey D Suhey↗

Overview of Integrated Random Vibration Testing of the NASA Orion Crew Survival Suit

The launch ascent and abort random vibration environments from NASA’s Orion spacecraft drove the need to test the NASA Orion Crew Survival Suit as an integrated system with exposure to the design levels. In order to properly characterize component responses, a series of integrated tests were designed to incorporate the interaction between a crew member, suit, seat, and the attenuation system. The first Development Test (2017) included human subjects, and was performed with early development seat and suit components, and low level inputs. It provided a baseline for frequency response and behavior of the integrated system. The next two tests, Development Test (2019) and Qualification Test (2020), used manikin surrogates to represent the crew member and increasing levels of component hardware fidelity in order to test to higher input levels. Testing was performed at NASA Johnson Space Center (JSC) and Kennedy Space Center (KSC) Vibration Labs and provided the input levels required to represent the ascent and abort vehicle profiles as well as recorded component response behavior from accelerometer instrumentation and high speed cameras. Inspection of the suit and related components showed that for all seat orientations, and input environments, no damage occurred. Additional pre and post-test checks confirmed the functionality of all suited hardware. Response data of the suited components generally showed heavy attenuation across most of the tested frequency range. Transmissibility plots showed some amplification of components at lower frequency ranges. Overall this series of integrated tests showed that 1) the use of surrogate manikins in the tests were adequate for representing crew in a vibration environment, 2) full vibration levels for ascent and abort were heavily attenuated in the suit components and were non-damaging, and 3) the suit and related components are qualified for the Orion random vibration environments.

Jeffrey Suhey↗