Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DISCRIMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Quantum field as a quantum cellular automaton: The Dirac free evolution in one dimension

We present a quantum cellular automaton model in one space-dimension which has the Dirac equation as emergent. This model, a discrete-time and causal unitary evolution of a lattice of quantum systems, is derived from the assumptions of homogeneity, parity and time-reversal invariance. The comparison between the automaton and the Dirac evolutions is rigorously set as a discrimination problem between unitary channels. We derive an exact lower bound for the probability of error in the discrimination as an explicit function of the mass, the number and the momentum of the particles, and the duration of the evolution. Computing this bound with experimentally achievable values, we see that in that regime the QCA model cannot be discriminated from the usual Dirac evolution. Finally, we show that the evolution of one-particle states with narrow-band in momentum can be efficiently simulated by a dispersive differential equation for any regime. This analysis allows for a comparison with the dynamics of wave-packets as it is described by the usual Dirac equation. This paper is a first step in exploring the idea that quantum field theory could be grounded on a more fundamental quantum cellular automaton model and that physical dynamics could emerge from quantum information processing. In this framework, the discretization is a central ingredient and not only a tool for performing non-perturbative calculation as in lattice gauge theory. The automaton model, endowed with a precise notion of local observables and a full probabilistic interpretation, could lead to a coherent unification of a hypothetical discrete Planck scale with the usual Fermi scale of high-energy physics. - Highlights: • The free Dirac field in one space dimension as a quantum cellular automaton. • Large scale limit of the automaton and the emergence of the Dirac equation. • Dispersive differential equation for the evolution of smooth states on the automaton. • Optimal discrimination between the automaton evolution and the Dirac equation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

1 H NMR-based metabolomics of antimalarial plant species traditionally used by Vha-Venda people in Limpopo Province, South Africa and isolation of antiplasmodial compounds

The Vha-Venda people living in rural areas of Limpopo Province of South Africa regularly use traditional plant-based medicines to treat malaria. In our earlier publication, twenty indigenous plant species used to treat malaria or its symptoms by Vha-Venda people were evaluated for antiplasmodial activity. The main objective of the current paper was to assess the robustness of NMR-based metabolomics in discriminating classes of secondary compounds that are responsible for the observed antimalarial activity and the isolation of antiplasmodial compounds. Twenty dichloromethane extracts were reconstituted in CDCl 3 , subjected to 1 H NMR-based metabolomic analysis on a Varian 600 MHz spectrometer and the acquired 1 H NMR spectra were then evaluated collectively using multivariate data analysis (MDA). Principal Component Analysis (PCA) and Orthogonal Projections to Latent Structures–Discriminant Analysis (OPLS-DA) were used to ‘globally’ discern antiplasmodial profiles. A contribution plot was then generated from the OPLS-DA scoring plot in an attempt to determine the classes of compounds that are responsible for the observed grouping. Further phytochemical analyses were conducted on the lipophilic extracts of Tabernaemontana elegans and Vangueria infausta subsp. infausta. These best candidates were fractionated, purified and their isolated compounds identified based on conventional chromatographic and spectroscopic techniques. The PCA did not separate the acquired profiles according to the detected antiplasmodial bioactivity. Application of a supervised OPLS-DA on the 1 H NMR profiles resulted in a discrimination pattern that could be correlated to the observed antimalarial bioactivity. A contribution plot generated from the OPLS-DA scoring plot illustrated the classes of compounds responsible for the observed grouping. Prominent peaks were observed in the aromatic, sugar-based/N-containing and aliphatic spectral regions of the contribution plot. Two known indole alkaloids were isolated from T. elegans, and identified as tabernaemontanine (IC 50 = 12.0±0.8 µM) and dregamine (IC 50 = 62.0±2.4 µM). Friedelin (IC 50 = 7.20±0.5 µM) and morindolide (IC 50 = 107.1±0.6 µM) were isolated from V. infausta subsp. infausta. This is the first report of the rare iridoid lactone, morindolide's antimalarial activity. While these two compounds have been previously identified, this is the first account of their occurrence in the genus Vangueria. The study illustrated the potential of NMR-based metabolomics in discriminating classes of compounds that may be attributed to antiplasmodial activity. Finally and additionally, the study demonstrated the potential of discovering novel antiplasmodial scaffolds from medicinal plants and the rationale for the bioprospecting antimalarial plant species used by Vha-Venda people.

59 BASIC BIOLOGICAL SCIENCES↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

X-ray diagnostic developments in the perspective of DEMO

Soft X-ray diagnostics at present are not adequate for a burning plasma experiment, neither in term of hardware nor as diagnostic conception. Detectors have to be radiation tolerant, easily shielded, with low sensitivity to neutrons and gammas and with energy discrimination. Layout and viewing capability should be more flexible, thanks to the use also of optical devices, going toward a configuration intermediate between discrete tomography and pure imaging. The general conception of these diagnostics should therefore evolve in the direction of pattern recognition for a real time feedback. This work is focused on the diagnostic developments undertaken at the ENEA- Frascati X-ray Laboratory, following in particular three directions: gas detector for fast and advanced high density tomography, C-MOS solid state imaging detectors for slow control and X-ray polycapillary optics. GEM gas detectors in photon counting mode (noise free) were developed in the range 1-30 keV having high efficiency, high time resolution (up to microseconds), energy discrimination in bands and optical flexibility. Discrimination of X-rays, neutrons and gammas has been demonstrated, thanks to the combination of intrinsic gain and discrimination thresholds, at neutron fluxes (10{sup 7} n/s*cm{sup 2}) comparable with the expected ones at the ports of ITER. GEM detectors are also extremely flexible in the design, allowing optimization of the measurements and solutions for shielding or minimization of the effect of background radiation. Two solid state C-MOS imagers working in photon counting mode, one based on Si semiconductor (Medipix-2, range 5-30 keV) and the other one having a CdTe sensor (Pixirad, range 2-100 keV) have been characterized in laboratory. C-MOS imagers have features and performances thoroughly complementary to the GEM detector and, thanks to their higher pixel density, could be used as remote imaging detectors coupled to optics. X-ray polycapillary lenses have been therefore studied in the laboratory both as imaging optical device (full lens) or to define a line of sight (cylinder lens); the preliminary results are encouraging toward the goal of using these lenses to transport X-ray radiation far from the reactor. Reflective or diffractive X-ray optics can be also an option for tomography. A GEM detector has been installed at KSTAR and in the next future hopefully the other approaches will be tested there: once their feasibility will be demonstrated, the issue of the improvement of the radiation tolerance will be faced and the development of algorithms for data analysis as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IceCube expectations for two high-energy neutrino production models at active galactic nuclei

We have determined the currently allowed regions of the parameter spaces of two representative models of diffuse neutrino flux from active galactic nuclei (AGN): one by Koers and Tinyakov (KT) and another by Becker and Biermann (BB). Our observable has been the number of upgoing muon-neutrinos expected in the 86-string IceCube detector, after 5 years of exposure, in the range 10{sup 5} ≤ E{sub ν}/GeV ≤ 10{sup 8}. We have used the latest estimated discovery potential of the IceCube-86 array at the 5σ level to determine the lower boundary of the regions, while for the upper boundary we have used either the AMANDA upper bound on the neutrino flux or the more recent preliminary upper bound given by the half-completed IceCube-40 array (IC40). We have varied the spectral index of the proposed power-law fluxes, α, and two parameters of the BB model: the ratio between the boost factors of neutrinos and cosmic rays, Γ{sub ν}/Γ{sub CR}, and the maximum redshift of the sources that contribute to the cosmic-ray flux, z{sub CR}{sup max}. For the KT model, we have considered two scenarios: one in which the number density of AGN does not evolve with redshift and another in which it evolves strongly, following the star formation rate. Using the IC40 upper bound, we have found that the models are visible in IceCube-86 only inside very thin strips of parameter space and that both of them are discarded at the preferred value of α = 2.7 obtained from fits to cosmic-ray data. Lower values of α, notably the values 2.0 and 2.3 proposed in the literature, fare better. In addition, we have analysed the capacity of IceCube-86 to discriminate between the models within the small regions of parameter space where both of them give testable predictions. Within these regions, discrimination at the 5σ level or more is guaranteed.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a ß emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly ?-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

Noble liquid detectors, Dark Matter detectors, Cry↗

Characterization of the CMS Endcap Timing Layer readout chip prototype with charge injection

We present the characterization of a readout Application-Specific Integrated Circuit (ASIC) for the CMS Endcap Timing Layer (ETL) of the High-Luminosity LHC upgrade with charge injection. The ASIC, named ETROC and developed in a 65 nm CMOS technology, reads out a 16× 16 pixel matrix of the Low-Gain Avalanche Detector (LGAD). The jitter contribution from ETROC is required to be below 40 ps to achieve the 50 ps overall time resolution per hit. The analog readout circuits in ETROC consist of the preamplifier and the discriminator. The preamplifier handles the LGAD charge signal with the most probable value of around 15 fC. The discriminator generates the digital pulse, which provides the Time-Of-Arrival (TOA, leading edge) and Time-Over-Threshold (TOT, pulse width) information. The prototype of ETROC (ETROC0) that implements a single channel of analog readout circuits has been evaluated with charge injection. The jitter of the analog readout circuits, measured from the discriminator's leading edge, is better than 16 ps for a charge larger than 15 fC with the sensor capacitance. The time walk resulting from different pulse heights can be corrected using the TOT measurement. The time resolution distribution has a standard deviation of 29 ps after the time-walk correction from the charge injection. At room temperature, the preamplifier's power consumption is measured to be 0.74 mW and 1.53 mW per pixel in the low- and high-power mode, respectively. Finally, the measured power consumption of the discriminator is 0.84 mW per pixel. With the ASIC alone or the LGAD sensor, The characterization performances fulfill the ETL's challenging requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Missing energy look-alikes with 100 pb{sup -1} at the CERN LHC.

A missing energy discovery is possible at the LHC with the first 100 pb{sup -1} of understood data. We present a realistic strategy to rapidly narrow the list of candidate theories at, or close to, the moment of discovery. The strategy is based on robust ratios of inclusive counts of simple physics objects. We study specific cases showing discrimination of look-alike models in simulated data sets that are at least 10 to 100 times smaller than used in previous studies. We discriminate supersymmetry models from nonsupersymmetric look-alikes with only 100 pb{sup -1} of simulated data, using combinations of observables that trace back to differences in spin.

43 PARTICLE ACCELERATORS↗

Dual Gamma Neutron Directional Elpasolite Detector

Some applications, particularly in homeland security, require detection of both neutron and gamma radiation. Typically, this is accomplished with a combination of two detectors registering neutrons and gammas separately. We have investigated a new type of neutron/gamma (n/γ) directional detection capability. We explored a new class of scintillator, cerium (Ce)-doped Elpasolites such as Cs2LiYCl6:Ce (CLYC), Cs2LiLaCl6 (CLLC), Cs2LiLaBr6:Ce (CLLB), or Cs2LiYBr6:Ce (CLYB). These materials are capable of providing energy resolution as good as 2.9% at 662 keV (FWHM), which is better than that of NaI:Tl. Because they contain 6Li, Elpasolites can also detect thermal neutrons. In the energy spectra, the full energy thermal neutron peak appears near or above 3 GEEn MeV. Thus, very effective pulse height discrimination is possible. In addition, the core-to-valence luminescence (CVL) provides Elpasolites with different temporal responses under gamma and neutron excitation, and, therefore, may be exploited for effective pulse shape discrimination. For instance, the CLLC emission consists of two main components: (1) CVL spanning from 220 nm to 320 nm and (2) Ce emission found in the range of 350 to 500 nm. The former emission is of particular interest because it appears only under gamma excitation. It is also very fast, decaying with a 2 ns time constant. The n/γ discrimination capability of Elpasolite detectors may be optimized by tuning the cerium doping content for maximum effect on n/γ pulse shape differences. The resulting Elpasolite detectors have the ability to collect neutron and gamma data simultaneously, with excellent discrimination. Further, an array of four of these Elpasolites detectors will perform directional detection in both the neutron and gamma channels simultaneously.

radiation detectors, neutron detectors, scintillat↗

Parametrization of textural patterns in {sup 123}I-ioflupane imaging for the automatic detection of Parkinsonism

Purpose: A novel approach to a computer aided diagnosis system for the Parkinson's disease is proposed. This tool is intended as a supporting tool for physicians, based on fully automated methods that lead to the classification of{sup 123}I-ioflupane SPECT images. Methods: {sup 123}I-ioflupane images from three different databases are used to train the system. The images are intensity and spatially normalized, then subimages are extracted and a 3D gray-level co-occurrence matrix is computed over these subimages, allowing the characterization of the texture using Haralick texture features. Finally, different discrimination estimation methods are used to select a feature vector that can be used to train and test the classifier. Results: Using the leave-one-out cross-validation technique over these three databases, the system achieves results up to a 97.4% of accuracy, and 99.1% of sensitivity, with positive likelihood ratios over 27. Conclusions: The system presents a robust feature extraction method that helps physicians in the diagnosis task by providing objective, operator-independent textural information about{sup 123}I-ioflupane images, commonly used in the diagnosis of the Parkinson's disease. Textural features computation has been optimized by using a subimage selection algorithm, and the discrimination estimation methods used here makes the system feature-independent, allowing us to extend it to other databases and diseases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual-energy cone-beam CT with a flat-panel detector: Effect of reconstruction algorithm on material classification

Purpose: Cone-beam CT (CBCT) with a flat-panel detector (FPD) is finding application in areas such as breast and musculoskeletal imaging, where dual-energy (DE) capabilities offer potential benefit. The authors investigate the accuracy of material classification in DE CBCT using filtered backprojection (FBP) and penalized likelihood (PL) reconstruction and optimize contrast-enhanced DE CBCT of the joints as a function of dose, material concentration, and detail size. Methods: Phantoms consisting of a 15 cm diameter water cylinder with solid calcium inserts (50–200 mg/ml, 3–28.4 mm diameter) and solid iodine inserts (2–10 mg/ml, 3–28.4 mm diameter), as well as a cadaveric knee with intra-articular injection of iodine were imaged on a CBCT bench with a Varian 4343 FPD. The low energy (LE) beam was 70 kVp (+0.2 mm Cu), and the high energy (HE) beam was 120 kVp (+0.2 mm Cu, +0.5 mm Ag). Total dose (LE+HE) was varied from 3.1 to 15.6 mGy with equal dose allocation. Image-based DE classification involved a nearest distance classifier in the space of LE versus HE attenuation values. Recognizing the differences in noise between LE and HE beams, the LE and HE data were differentially filtered (in FBP) or regularized (in PL). Both a quadratic (PLQ) and a total-variation penalty (PLTV) were investigated for PL. The performance of DE CBCT material discrimination was quantified in terms of voxelwise specificity, sensitivity, and accuracy. Results: Noise in the HE image was primarily responsible for classification errors within the contrast inserts, whereas noise in the LE image mainly influenced classification in the surrounding water. For inserts of diameter 28.4 mm, DE CBCT reconstructions were optimized to maximize the total combined accuracy across the range of calcium and iodine concentrations, yielding values of ∼88% for FBP and PLQ, and ∼95% for PLTV at 3.1 mGy total dose, increasing to ∼95% for FBP and PLQ, and ∼98% for PLTV at 15.6 mGy total dose. For a fixed iodine concentration of 5 mg/ml and reconstructions maximizing overall accuracy across the range of insert diameters, the minimum diameter classified with accuracy >80% was ∼15 mm for FBP and PLQ and ∼10 mm for PLTV, improving to ∼7 mm for FBP and PLQ and ∼3 mm for PLTV at 15.6 mGy. The results indicate similar performance for FBP and PLQ and showed improved classification accuracy with edge-preserving PLTV. A slight preference for increased smoothing of the HE data was found. DE CBCT discrimination of iodine and bone in the knee was demonstrated with FBP and PLTV at 6.2 mGy total dose. Conclusions: For iodine concentrations >5 mg/ml and detail size ∼20 mm, material classification accuracy of >90% was achieved in DE CBCT with both FBP and PL at total doses <10 mGy. Optimal performance was attained by selection of reconstruction parameters based on the differences in noise between HE and LE data, typically favoring stronger smoothing of the HE data, and by using penalties matched to the imaging task (e.g., edge-preserving PLTV in areas of uniform enhancement)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physics-Informed Generative Adversarial Networks for Stochastic Differential Equations

We developed a new class of physics-informed generative adversarial networks (PI-GANs) to solve forward, inverse, and mixed stochastic problems in a unified manner based on a limited number of scattered measurements. Unlike standard GANs relying solely on data for training, here we encoded into the architecture of GANs the governing physical laws in the form of stochastic differential equations (SDEs) using automatic differentiation. In particular, we applied Wasserstein GANs with gradient penalty (WGAN-GP) for its enhanced stability compared to vanilla GANs. We first tested WGAN-GP in approximating Gaussian processes of different correlation lengths based on data realizations collected from simultaneous reads at sparsely placed sensors. We obtained good approximation of the generated stochastic processes to the target ones even if there is a mismatch between the input noise dimensionality and the effective dimensionality of the target stochastic processes. We also studied the overfitting issue for both the discriminator and the generator, and we found that overfitting occurs also in the generator in addition to the discriminator as previously reported. Subsequently, we considered the solution of elliptic SDEs requiring approximations of three stochastic processes, namely the solution, the forcing, and the diffusion coefficient. Here again, we assumed data collected from simultaneous reads at a limited number of sensors for the multiple stochastic processes. Furthermore, three generators were used for the PI-GANs: two of them were feed forward deep neural networks (DNNs), while the other one was the neural network induced by the SDE. For the case where we have one group of data, we employed one feed forward DNN as the discriminator, while for the case of multiple groups of data we employed multiple discriminators in PI-GANs. We solved forward, inverse, and mixed problems without changing the framework of PI-GANs, obtaining both the means and the standard deviations of the stochastic solution and the diffusion coefficient in good agreement with benchmarks. In this work, we have demonstrated the effectiveness of PI-GANs in solving SDEs for about 120 dimensions. In principle, PI-GANs could tackle very high dimensional problems given more sensor data with low-polynomial growth in computational cost.

97 MATHEMATICS AND COMPUTING↗

AmpSuite

Seismic amplitudes offer vital information about explosion source characteristics, including discrimination and yield estimation. To take advantage of this, we developed an interactive Python package to measure, control data quality, generate broad area propagation models and perform discrimination and estimate yield. Propagation models are essential in support of transportable yield and broad area discrimination. The key benefit of this package will be its ability to continuously integrate data and new techniques. The AmpSuite framework will provide standardized, repeatable, and accurate model generation and characterization routines. The capability is crucial for monitoring agencies tasked with rapid and high-quality seismic event characterization. The AmpSuite software includes a series of independent modules to perform: • Direct Phase Amplitude Measurement and Storage • Coda Envelope Measurement and Storage • Data Quality Control • New Propagation Model Developments • Seismic Discrimination and Analysis • Yield Estimation and supporting utility software. The AmpSuite software provides comprehensive solutions for monitoring agencies seeking to optimize model generation and event analysis within a contemporary Python framework. Stakeholders (AFTAC) have begun to move towards the Python language for scientific analysis as a new workforce emerges.

Alfaro, Richard↗

Gravity monitoring of CO{sub 2} movement during sequestration: Model studies

Sequestration/enhanced oil recovery (EOR) petroleum reservoirs have relatively thin injection intervals with multiple fluid components (oil, hydrocarbon gas, brine, and carbon dioxide, or CO{sub 2}), whereas brine formations usually have much thicker injection intervals and only two components (brine and CO{sub 2}). Coal formations undergoing methane extraction tend to be thin (3-10 m) but shallow compared to either EOR or brine formations. Injecting CO{sub 2} into an oil reservoir decreases the bulk density in the reservoir. The spatial pattern of the change in the vertical component of gravity (G{sub z}) is correlated directly with the net change in reservoir density. Furthermore, time-lapse changes in the borehole G{sub z} clearly identify the vertical section of the reservoir where fluid saturations are changing. The CO{sub 2}-brine front, on the order of 1 km within a 20-m-thick brine formation at 1900-m depth with 30% CO{sub 2} and 70% brine saturations, respectively, produced a -10-{mu} Gal surface gravity anomaly. Such an anomaly would be detectable in the field. The amount of CO{sub 2} in a coal-bed methane scenario did not produce a large enough surface gravity response; however, we would expect that for an industrial-size injection, the surface gravity response would be measurable. Gravity inversions in all three scenarios illustrate that the general position of density changes caused by CO{sub 2} can be recovered but not the absolute value of the change. Analysis of the spatial resolution and detectability limits shows that gravity measurements could, under certain circumstances, be used as a lower-cost alternative to seismic measurements.

01 COAL, LIGNITE, AND PEAT↗

Moment tensor analysis of very shallow sources

An issue for moment tensor (MT) inversion of shallow seismic sources is that some components of the Green’s functions have vanishing amplitudes at the free surface, which can result in bias in the MT solution. The effects of the free surface on the stability of the MT method become important as we continue to investigate and improve the capabilities of regional full MT inversion for source–type identification and discrimination. It is important to understand free–surface effects on discriminating shallow explosive sources for nuclear monitoring purposes. It may also be important in natural systems that have very shallow seismicity, such as volcanic and geothermal systems. We examine the effects of the free surface on the MT via synthetic testing and apply the MT–based discrimination method to three quarry blasts from the HUMMING ALBATROSS experiment. These shallow chemical explosions at ~10 m depth and recorded up to several kilometers distance represent rather severe source–station geometry in terms of free–surface effects. We show that the method is capable of recovering a predominantly explosive source mechanism, and the combined waveform and first–motion method enables the unique discrimination of these events. Furthermore, recovering the design yield using seismic moment estimates from MT inversion remains challenging, but we can begin to put error bounds on our moment estimates using the network sensitivity solution technique.

58 GEOSCIENCES↗

Hypothesis Tests on Rayleigh Wave Radiation Pattern Shapes: A Theoretical Assessment for Source Screening (Independent Review: LANL Source Physics LCP) [Slides]

Background for TRL 0-1 Research: we require a simple regional source discriminant that has a predictive capability and a quantifiable screening performance (probability of correct attribution); Challenge: many local and near-regional source discriminants do not test source mechanism; rather, they test depth. Such empirically validated discriminants are not all theoretically justified; and, Proposal: we test Rayleigh wave radiation patterns for any significant deviation from circular shape as a discriminant.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

20th century changes in carbon isotopes and water-use efficiency: tree-ring-based evaluation of the CLM4.5 and LPX-Bern models

Measurements of the stable carbon isotope ratio ( δ 13 C) on annual tree rings offer new opportunities to evaluate mechanisms of variations in photosynthesis and stomatal conductance under changing CO 2 and climate conditions, especially in conjunction with process-based biogeochemical model simulations. The isotopic discrimination is indicative of the ratio between the CO 2 partial pressure in the intercellular cavities and the atmosphere ( c i / c a ) and of the ratio of assimilation to stomatal conductance, termed intrinsic water-use efficiency (iWUE). We performed isotope-enabled simulations over the industrial period with the land biosphere module (CLM4.5) of the Community Earth System Model and the Land Surface Processes and Exchanges (LPX-Bern) dynamic global vegetation model. Results for C3 tree species show good agreement with a global compilation of δ 13 C measurements on leaves, though modeled 13 C discrimination by C3 trees is smaller in arid regions than measured. A compilation of 76 tree-ring records, mainly from Europe, boreal Asia, and western North America, suggests on average small 20th century changes in isotopic discrimination and in c i / c a and an increase in iWUE of about 27% since 1900. LPX-Bern results match these century-scale reconstructions, supporting the idea that the physiology of stomata has evolved to optimize trade-offs between carbon gain by assimilation and water loss by transpiration. In contrast, CLM4.5 simulates an increase in discrimination and in turn a change in iWUE that is almost twice as large as that revealed by the tree-ring data. Factorial simulations show that these changes are mainly in response to rising atmospheric CO 2 . The results suggest that the downregulation of c i / c a and of photosynthesis by nitrogen limitation is possibly too strong in the standard setup of CLM4.5 or that there may be problems associated with the implementation of conductance, assimilation, and related adjustment processes on long-term environmental changes.

54 ENVIRONMENTAL SCIENCES↗

Temporal analysis of multispectral scanner data.

Multispectral scanner reflectance data were sampled for bare soil, cotton, sorghum, corn, and citrus at four dates during a growing season (April, May, June, and July 1969) to develop a time-dependent signature for crop and soil discrimination. Discrimination tests were conducted for single-date and multidate formats using training and test data sets. For classifications containing several crops, the multidate or temporal approach improved discrimination compared with the single-date approach. The multidate approach also preserved recognition accuracy better in going from training fields to test fields than the single-date analysis. The spectral distinctiveness of bare soil versus vegetation resulted in essentially equal discrimination using single-date versus multidate data for those two categories.

Richardson, A. J.↗