Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DIFFRACTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Diffraction microscopy using 20 kV electron beam for multiwall carbon nanotubes

Diffraction microscopy with iterative phase retrieval using a 20 kV electron beam was carried out to explore the possibility of high-resolution imaging for radiation-sensitive materials. Fine, homogeneous, and isolated multiwall carbon nanotubes (MWCNTs) were used as specimens. To avoid lens aberrations, the diffraction patterns were recorded without a postspecimen lens. One- and two-dimensional iterative phase retrievals were executed. Images reconstructed from the diffraction pattern alone showed a characteristic structure of MWCNTs with the finest feature corresponding to a carbon wall spacing of 0.34 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pulsed Neutron Powder Diffraction for Materials Science

The accelerator-based neutron diffraction began in the end of 60's at Tohoku University which was succeeded by the four spallation neutron facilities with proton accelerators at the High Energy Accelerator Research Organization (Japan), Argonne National Laboratory and Los Alamos Laboratory (USA), and Rutherford Appleton Laboratory (UK). Since then, the next generation source has been pursued for 20 years, and 1MW-class spallation neutron sources will be appeared in about three years at the three parts of the world: Japan, UK and USA. The joint proton accelerator project (J-PARC), a collaborative project between KEK and JAEA, is one of them. The aim of the talk is to describe about J-PARC and the neutron diffractometers being installed at the materials and life science facility of J-PARC. The materials and life science facility of J-PARC has 23 neutron beam ports and will start delivering the first neutron beam of 25 Hz from 2008 May. Until now, more than 20 proposals have been reviewed by the review committee, and accepted proposal groups have started to get fund. Those proposals include five polycrystalline diffractometers: a super high resolution powder diffractometer (SHRPD), a 0.2%-resolution powder diffractometer of Ibaraki prefecture (IPD), an engineering diffractometers (Takumi), a high intensity S(Q) diffractometer (VSD), and a high-pressure dedicated diffractometer. SHRPD, Takumi and IPD are being designed and constructed by the joint team of KEK, JAEA and Ibaraki University, whose member are originally from the KEK powder group. These three instruments are expected to start in 2008. VSD is a super high intensity diffractometer with the highest resolution of {delta}d/d = 0.3%. VSD can measure rapid time-dependent phenomena of crystalline materials as well as glass, liquid and amorphous materials. The pair distribution function will be routinely obtained by the Fourier transiformation of S(Q) data. Q range of VSD will be as wide as 0.01 A{sup -1}<Q<100 A{sup -1}. IPD is fully funded by Ibaraki prefecture for the promotion of new industries based on advanced science and technologies. It is for the first time in neutron facilities in Japan that a prefecture owns neutron instruments as well as neutron beam will be provided widely to industrial users. To make it successful, the user system is quite important because those users are expected to use IPD like chemical analyzers in their materials development process. Based on questionnaire data to several hundreds industries, IPD is designed as a versatile diffractometer including texture measurement, small angle scattering and total scattering as well as usual powder diffraction. IPD covers d range 0.15<d(A)<4 with {delta}d/d 0.15%, and covers 4<d(A)<60 with gradually changing resolution. Q range of IPD will be as wide as 0.01 A{sup -1}<Q<50A{sup -1} to be utilized for varieties of structures: local structure, nano structure and crystal structure analyses. Typical measuring time for the typical 'Rietveld-quality' data is several minutes with the sample size of laboratory X-ray: 0.4 cc. SHRPD is designed to be the world highest resolution with {delta}d/d = 0.03% without sacrificing intensity. The combination of the high quality data from HRPD and their high-precision analysis gives us information on tiny structural changes which have been overlooked. After careful examination with the moderator group five years ago, we have decided to develop a high-resolution and good S/N moderator to achieve the 0.03% resolution within 100 m flight path. This development was almost successful up to now. Instrumental simulation and radiation analysis were almost completed. The d range 0.5<d(A)<4 with {delta}d/d = 0.03%, and covers 4<d(A)<45 with gradually changing resolution. Takumi is the first priority instrument in JAEA for stress mapping inside structure materials with the highest resolution of {delta}d/d = 0.2% (corresponding to 10{approx}5 to 10{approx}6 strain precision). The typical gauge volume will be 1 mm3. JED has transmission radiography detectors to support stress mapping. Software group is planning so that basic software to cover data acquisition and data treatment should be common. Since 1 Gbyte data are typically obtained for single experiment in an instrument, the basic software is quite important. International TV conference between ISIS, IPNS, SNS has been held every month to exchange information on each development. KEK developed manyo-lib to help basic analysis. Analysis software development including powder diffraction is strongly related with the activity of the software group. However, users of IPD will be from various field of science and their background is different. It should cover wide topics and help both beginners and well-trained users. We have started with neutron intensity database, peak-search software, peak-match software, pattern simulation, whole pattern fitting, PDF and RDF analysis, and now start coding Rietveld software.

36 MATERIALS SCIENCE↗

Low-energy electron diffraction and induced damage in hydrated DNA

Elastic scattering of 5-30 eV electrons within the B-DNA 5{sup '}-CCGGCGCCGG-3{sup '} and A-DNA 5{sup '}-CGCGAATTCGCG-3{sup '} DNA sequences is calculated using the separable representation of a free-space electron propagator and a curved wave multiple scattering formalism. The disorder brought about by the surrounding water and helical base stacking leads to a featureless amplitude buildup of elastically scattered electrons on the sugar and phosphate groups for all energies between 5 and 30 eV. However, some constructive interference features arising from diffraction are revealed when examining the structural waters within the major groove. These appear at 5-10, 12-18, and 22-28 eV for the B-DNA target and at 7-11, 12-18, and 18-25 eV for the A-DNA target. Although the diffraction depends on the base-pair sequence, the energy dependent elastic scattering features are primarily associated with the structural water molecules localized within 8-10 A spheres surrounding the bases and/or the sugar-phosphate backbone. The electron density buildup occurs in energy regimes associated with dissociative electron attachment resonances, direct electronic excitation, and dissociative ionization. Since diffraction intensity can be localized on structural water, compound H{sub 2}O:DNA states may contribute to energy dependent low-energy electron induced single and double strand breaks.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spectral Line Profile Analysis Using Higher Diffraction Order in Vacuum Ultraviolet Region

Using a one meter VUV spectrometer and a MCP coupled to a CCD detector on TCABR tokamak, ion temperatures from impurity species have been measured and much better spectral resolution was obtained using higher order diffraction lines. Due to very small Doppler effect in the VUV region compared to large instrumental broadening, ion temperatures obtained from first order diffraction present large errors. The use of second, third and fourth order diffraction emissions increases the line broadening and results in lower error temperature measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Freestanding diffractive optical elements as light extractors for burning plasma experiments

Optical diagnostics will be critical for the operation and performance assessment of burning plasma experiments, such as ITER. At the same time, extracting light for these diagnostics with reflective mirrors becomes difficult in the burning plasma environment due to the deleterious effects of the prolonged exposure on plasma and nuclear radiations. As an alternative, we explore the possibility to use freestanding diffractive optical elements, such as transmission gratings and zone plates, as light extractors. Since in diffractive systems, light is deflected by periodic slits rather than by a surface, these may withstand plasma exposure with less degradation of their optical properties. To investigate this possibility, we developed freestanding transmission gratings for the visible range and exposed them to conditions resembling (or even exceeding) those expected for the ITER 'first mirrors.' The results of this study indicate that the gratings can withstand high heat fluxes and plasma and energetic radiation bombardment. Additionally, in contrast to the reflective elements, the extraction efficiency of diffractive elements may even improve with plasma exposure, which is possibly due to the shaping and thinning of the grating bars by plasma erosion. Moreover, in tightly collimated configurations, even very thin gratings can be used to extract light from hot fusion plasmas, as demonstrated by our tests of an extreme ultraviolet extractor at the National Spherical Torus Experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An ultrahigh-vacuum apparatus for resonant diffraction experiments using soft x rays (h{nu}=300-2000 eV)

We have developed an ultrahigh-vacuum instrument for resonant diffraction experiments using polarized soft x rays in the energy range of h{nu}=300-2000 eV at beamline BL17SU of SPring-8. The diffractometer consists of modified differentially pumped rotary feedthroughs for {theta}-2{theta} stages, a sample manipulator with motor-controlled x-y-z-, tilt ({chi})-, and azimuth ({phi})-axes, and a liquid helium flow-type cryostat for temperature dependent measurements between 30 and 300 K. Test results indicate that the diffractometer exhibits high reproducibility (better than 0.001 deg.) for a Bragg reflection of {alpha}-quartz 100 at a photon energy of h{nu}=1950 eV. Typical off- and on-resonance Bragg reflections in the energy range of 530-1950 eV could be measured using the apparatus. The results show that x-ray diffraction experiments with energy-, azimuth-, and incident photon polarization-dependence can be reliably measured using soft x rays in the energy range of {approx}300-2000 eV. The facility can be used for resonant diffraction experiments across the L-edge of transition metals, M-edge of lanthanides, and up to the Si K-edge of materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase transition in Ba{sub 2}In{sub 2}O{sub 5} studied by in situ high temperature X-ray diffraction using synchrotron radiation

The order-disorder phase transition in Ba{sub 2}In{sub 2}O{sub 5} high-temperature ionic conductor was systematically studied by in situ high-temperature X-ray diffraction using synchrotron radiation and electrical conductivity. Pure barium indate was prepared by solid state reactions at 1300 deg. C. The room-temperature structural characterization showed a high degree of phase homogeneity in the prepared material. The reduction of the order-disorder phase transition temperature was verified by electrical conductivity and high-temperature X-ray diffraction. The observed features were explained based on Fourier-transform infrared spectroscopy results that revealed the presence of hydroxyl species in the crystal lattice. The increase of the intensity of few diffraction peaks near the phase transition temperature suggests the formation of a superstructure before the orthorhombic-to-tetragonal phase transition.

36 MATERIALS SCIENCE↗

An instrument for combining x-ray multiple diffraction and x-ray topographic imaging for examining crystal microcrystallography and perfection

Diffraction imaging using x-ray topography (XRT) and x-ray multiple diffraction (XRMD) provide valuable tools for examining the growth defects in crystals and the distributions from ideal lattice symmetry (microcrystallography). The topographic x-ray multiple diffraction microprobe (TMDM) combines the complementary aspects of both techniques enabling XRT and XRMD studies within the same instrument providing a useful resource for the structural characterization of materials that are not very stable in vacuum and electron beam environments. The design of the TMDM instrument is described together with data taken on GaAs (001) and potassium dihydrogen phosphate (001)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ALICE diffractive physics in p-p and Pb-Pb collisions at the LHC

The ALICE experiment at the Large Hadron Collider LHC is presently being commissioned. ALICE consists of a central barrel, a muon spectrometer and neutron calorimeters at 0 deg. Additional detectors for event classification and trigger purposes are located on both sides of the central barrel. The geometry of the ALICE detector allows the implementation of a diffractive double gap trigger by requiring two or more tracks in the central barrel but no activity in the event classification detectors. Some selected diffractive physics channels are discussed which become accessible by a double gap trigger. The interest of such diffractive measurements in proton-proton as well as in lead-lead collisions is outlined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Real time synchrotron x-ray diffraction measurements to determine material strength of shocked single crystals following compression and release

We present a method to use real time, synchrotron x-ray diffraction measurements to determine the strength of shocked single crystals following compression and release during uniaxial strain loading. Aluminum and copper single crystals shocked along [111] were examined to peak stresses ranging from 2 to 6 GPa. Synchrotron x rays were used to probe the longitudinal lattice strains near the rear free surface (16 and 5 {micro}m depths for Al and Cu, respectively) of the metal crystals following shock compression and release. The 111 diffraction peaks showed broadening indicating a heterogeneous microstructure in the released state. The diffraction peaks also shifted to lower Bragg angles relative to the ambient Bragg angle; the magnitude of the shift increased with increasing impact stress. The Bragg angle shifts and appropriate averaging procedures were used to determine the macroscopic or continuum strength following compression and release. For both crystals, the strengths upon release increased with increasing impact stress and provide a quantitative measure of the strain hardening that occurs in Al(111) and Cu(111) during the shock and release process. Our results for Al(111) are in reasonable agreement with a previous determination based solely on continuum measurements. Two points are noteworthy about the developments presented here: Synchrotron x rays are needed because they provide the resolution required for analyzing the data in the released state; the method presented here can be extended to the shocked state but will require additional measurements.

36 MATERIALS SCIENCE↗

Diffraction at HERA

Diffractive phenomena are an essential component of the understanding of the proton structure and lead to stringent tests of the QCD. New results are presented in the area of inclusive diffraction, with a vast coverage of the phase space and where both H1 and ZEUS data compare and may lead to combinations and data constraints. The issue of universality of the diffractive exchange is tested using final states, for instance with jets, where new results completed the previous hints of discrepancies. The production of photons and vector mesons, all recently measured either for the first time or with improved precision, present a rich panel of tests of the QCD predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diffractive PDF fits and factorisation tests at HERA

A DGLAP next-to-leading-order QCD analysis to extract the diffractive parton distribution functions, using DIS inclusive and dijet diffractive HERA data, is presented. Predictions based on the extracted parton densities are compared to diffractive dijet photoproduction data to discuss factorisation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Diffraction and central exclusive production at ATLAS

The diffractive physics program for the ATLAS experiment with an emphasis on the central exclusive production is discussed. The key point in this discussion is the need for an unambiguous experimental definition of diffractive signature which would be acceptable and reproducible by theorists. Recent ATLAS results from samples enhanced in diffraction contribution underline this need.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Imaging single electrons to enable the generation of ultrashort beams for single-shot femtosecond relativistic electron diffraction

The generation and control of relativistic electron beams well suited for ultrafast electron diffraction application has rapidly advanced, greatly benefiting from the overlap in techniques and expertise with the accelerator community. However, imaging the diffracted MeV electrons with high detection efficiency has remained an under-explored area. In this paper, we report on a quantitative study of the imaging of MeV electrons using a detection system consisting of a phosphor screen, a lens-coupling optics, and a charge-coupled device camera. It is shown that every MeV electron in the beam yields a signal well above the camera noise. With this detection efficiency, only {approx}10{sup 5} electrons per pulse are needed to obtain a high quality single-shot diffraction pattern from a crystalline sample. We measured that such a low charge beam can be as short as 30 fs rms. Further, we discuss the possibility of compressing these electron beams to sub-5 fs rms bunch length by velocity bunching using a short high gradient rf accelerating structure scheduled to be installed next year at the UCLA Pegasus Laboratory. This opens the possibility of single-shot determinations of structural changes in many ultrafast physical processes like nonequilibrium phonon dynamics or relaxation pathways in systems with strong electron-phonon coupling.

43 PARTICLE ACCELERATORS↗

Computer simulation on spatial resolution of X-ray bright-field imaging by dynamical diffraction theory for a Laue-case crystal analyzer

Recently, dark-field imaging (DFI) and bright-field imaging (BFI) have been proposed and applied to visualize X-ray refraction effects yielded in biomedical objects. In order to clarify the spatial resolution due to a crystal analyzer in Laue geometry, a program based on the Takagi-Taupin equation was modified to be used for carrying out simulations to evaluate the spatial resolution of images coming into a Laue angular analyzer (LAA). The calculation was done with a perfect plane wave for diffraction wave-fields, which corresponded to BFI, under the conditions of 35 keV and a diffraction index 440 for a 2100 {mu}m thick LAA. As a result, the spatial resolution along the g-vector direction showed approximately 37.5 {mu}m. 126 {mu}m-thick LAA showed a spatial resolution better than 3.1 {mu}m under the conditions of 13.7 keV and a diffraction index 220.

36 MATERIALS SCIENCE↗

Anisotropic response of nanosized bismuth films upon femtosecond laser excitation monitored by ultrafast electron diffraction

The lattice response of 5 nm thick bismuth film to femtosecond laser excitation is probed by ultrafast electron diffraction. The transient decay time after laser excitation is greater for diffraction from (012) lattice planes compared to (110) planes and is reduced for both planes with the increased laser fluence. These results indicate that different energy coupling mechanisms to the lattice occur depending on the crystal direction. The behavior of the diffraction peak width indicates partial disorder of the film upon photoexcitation that increases together with the laser fluence.

36 MATERIALS SCIENCE↗

Simultaneous detection of surface coverage and structure of krypton films on gold by helium atom diffraction and quartz crystal microbalance techniques

We describe a quartz crystal microbalance setup that can be operated at low temperatures in ultra high vacuum with gold electrode surfaces acting as substrate surface for helium diffraction measurements. By simultaneous measurement of helium specular reflection intensity from the electrode surface and resonance frequency shift of the crystal during film adsorption, helium diffraction data can be correlated to film thickness. In addition, effects of interfacial viscosity on the helium diffraction pattern could be observed. To this end, first, flat gold films on AT cut quartz crystals were prepared which yield high enough helium specular reflection intensity. Then the crystals were mounted in the helium diffractometer sample holder and driven by means of a frequency modulation driving setup. Different crystal geometries were tested to obtain the best quality factor and preliminary measurements were performed on Kr films on gold surfaces. While the crystal structure and coverage of krypton films as a function of substrate temperature could successfully be determined, no depinning effects could be observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas gun shock experiments with single-pulse x-ray phase contrast imaging and diffraction at the Advanced Photon Source

The highly transient nature of shock loading and pronounced microstructure effects on dynamic materials response call for in situ, temporally and spatially resolved, x-ray-based diagnostics. Third-generation synchrotron x-ray sources are advantageous for x-ray phase contrast imaging (PCI) and diffraction under dynamic loading, due to their high photon fluxes, high coherency, and high pulse repetition rates. The feasibility of bulk-scale gas gun shock experiments with dynamic x-ray PCI and diffraction measurements was investigated at the beamline 32ID-B of the Advanced Photon Source. The x-ray beam characteristics, experimental setup, x-ray diagnostics, and static and dynamic test results are described. We demonstrate ultrafast, multiframe, single-pulse PCI measurements with unprecedented temporal (<100 ps) and spatial ({approx}2 {mu}m) resolutions for bulk-scale shock experiments, as well as single-pulse dynamic Laue diffraction. The results not only substantiate the potential of synchrotron-based experiments for addressing a variety of shock physics problems, but also allow us to identify the technical challenges related to image detection, x-ray source, and dynamic loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗