TU-F-18A-08: Effect of Quantum Detection Efficiency and Energy Bin Selection On Contrast-To-Noise-Ratio for Energy-Resolved Photon-Counting Detectors

Purpose: Energy-resolved photon-counting detectors have the capability to discriminate photons according to their energies. By using optimal energy weighting factors, the contrast-to-noise-ratio (CNR) of the reconstructed image can be improved. In this work, we investigate how quantum detection efficiency (QDE) affects the determination of the optimal energy threshold bins, and therefore the CNR improvement of photon-counting detectors. Methods: In this simulation study a photon-counting detector, based on Silicon (Si), was investigated. A task-oriented algorithm was used to determine the optimal energy bin setting in order to maximize CNR. Projection-based and Image-based energy weighting techniques were implemented. A 13 mm PMMA phantom with two contrast materials, hydroxyapatite (HA) and iodine (I), at different concentrations (100, 200, and 300 mg/mL for HA and 2, 4, and 8 mg/mL for I) was used. TASMIP algorithm was used to generate the spectrum with 2.7 mm Al filter. Different tube voltages, number of energy bins, and bin widths were investigated. Different thicknesses of Si were also investigated to determine the QDE effect on CNR. Results: CNR increased as the detector material thickness increased until it reached 30 mm for Si thickness such that the CNR value was near to the value predicted by an ideal detector. Also, the results indicated that the improvement of CNR due to the QDE is task-dependent when comparing weighted images to photon-counting images. For hydroxyapatite the improvement is approximately 20%, whereas for iodine it is less than 10%. Conclusion: The results showed that the improvement of CNR for an energy-resolved photon-counting detector is highly task-dependent when QDE is taken into account.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Poster — Thur Eve — 27: Flattening Filter Free VMAT Quality Assurance: Dose Rate Considerations for Detector Response

Introduction: Radiation detector responses can be affected by dose rate. Due to higher dose per pulse and wider range of mu rates in FFF beams, detector responses should be characterized prior to implementation of QA protocols for FFF beams. During VMAT delivery, the MU rate may also vary dramatically within a treatment fraction. This study looks at the dose per pulse variation throughout a 3D volume for typical VMAT plans and the response characteristics for a variety of detectors, and makes recommendations on the design of QA protocols for FFF VMAT QA. Materials and Methods: Linac log file data and a simplified dose calculation algorithm are used to calculate dose per pulse for a variety of clinical VMAT plans, on a voxel by voxel basis, as a function of time in a cylindrical phantom. Diode and ion chamber array responses are characterized over the relevant range of dose per pulse and dose rate. Results: Dose per pulse ranges from <0.1 mGy/pulse to 1.5 mGy/pulse in a typical VMAT treatment delivery using the 10XFFF beam. Diode detector arrays demonstrate increased sensitivity to dose (+./− 3%) with increasing dose per pulse over this range. Ion chamber arrays demonstrate decreased sensitivity to dose (+/− 1%) with increasing dose rate over this range. Conclusions: QA protocols should be designed taking into consideration inherent changes in detector sensitivity with dose rate. Neglecting to account for changes in detector response with dose per pulse can lead to skewed QA results.

60 APPLIED LIFE SCIENCES↗

Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy

Purpose: Plastic scintillation detectors are promising candidates for the dosimetry of low- to medium-energy photons but quantitative knowledge of their energy response is a prerequisite for their correct use. The purpose of this study was to characterize the energy dependent response of small scintillation detectors (active volume <1 mm{sup 3}) made from the commonly used plastic scintillator BC400. Methods: Different detectors made from BC400 were calibrated at a number of radiation qualities ranging from 10 to 280 kV and at a {sup 60}Co beam. All calibrations were performed at the Physikalisch-Technische Bundesanstalt, the National Metrology Institute of Germany. The energy response in terms of air kerma, dose to water, and dose to the scintillator was determined. Conversion factors from air kerma to dose to water and to dose to the scintillator were derived from Monte Carlo simulations. In order to quantitatively describe the energy dependence, a semiempirical model known as unimolecular quenching or Birks’ formula was fitted to the data and from this the response to secondary electrons generated within the scintillator material BC400 was derived. Results: The detector energy response in terms of air kerma differs for different scintillator sizes and different detector casings. It is therefore necessary to take attenuation within the scintillator and in the casing into account when deriving the response in terms of dose to water from a calibration in terms of air kerma. The measured energy response in terms of dose to water for BC400 cannot be reproduced by the ratio of mean mass energy-absorption coefficients for polyvinyl toluene to water but shows evidence of quenching. The quenching parameter kB in Birks’ formula was determined to be kB = (12.3 ± 0.9) mg MeV{sup −1} cm{sup −2}. Conclusions: The energy response was quantified relative to the response to {sup 60}Co which is the common radiation quality for the calibration of therapy dosemeters. The observed energy dependence could be well explained with the assumption of ionization quenching as described by Birks’ formula. Plastic scintillation detectors should be calibrated at the same radiation quality that they will be used at and changes of the spectrum within the application need to be considered. The authors results can be used to evaluate the range of validity of a given calibration.

60 APPLIED LIFE SCIENCES↗

Feynman-α analysis using BGO gamma-ray detector in UTR-KINKI reactor

In conventional reactor noise measurement based on neutron detection, a neutron detector must be placed as close to a core as possible, to observe a largest possible correlation amplitude. For most of reactors other than critical assemblies, however, the placement is hardly possible. We focused on an alternative reactor noise measurement using prompt gamma-rays having a long flight range, to overcome the above constraint. A Feynman-α analysis using a NaI(Tl) scintillation detector was previously performed in UTR-KINKI, however, white noise originating from radioactivation of the scintillator significantly degraded the correlation amplitude. In this study, another Feynman-α analysis using a BGO gamma-ray detector, which never suffers from any radioactivation, is performed. A series of Feynman-α analyses for a critical state and several subcritical states of UTR-KINKI reactor has been carried out using two BGO detectors and a BF{sub 3} neutron detector to determine prompt-neutron decay constant. In the present analysis, the dead-time effect of these detectors and the delayed-neutron effect are considered. The prompt-neutron decay constant determined from Feynman-α analysis based on gamma-ray detection agrees with that from the analysis based on neutron detection. The Feynman-α analysis based on detecting gamma rays appears to be able to determine prompt-neutron decay constant at least as efficiently as the conventional analysis detecting neutrons.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Resolution PET Detector. Final report

The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Report on the Tin-II Thermal Neutron Detector

Thermal neutrons have recently become a concern in the semiconductor community where it has been reported that approximately 20% of the single-event upsets are due to thermal neutrons in some devices. The goal of this project is to measure the intensity of thermal neutrons in the High- Performance Computing (HPC) area. This is part of a larger effort to characterize the radiation environment in the HPC area which includes high-energy neutrons as well as thermal neutrons. To accomplish this goal, we designed and fabricated a neutron detector that is sensitive to thermal neutrons called Tin-II. The Tin-II detector consists of two identical 3He ionization chambers with one detector bare and one detector shielded with cadmium. Because the cadmium shielding effectively blocks the thermal neutrons, the difference in count rates between these two detectors reflect the number of thermal neutrons detected. This report summarizes the status of our efforts to develop this detector.

47 OTHER INSTRUMENTATION↗

Scalable Background-Limited Polarization-Sensitive Detectors for mm-wave Applications

We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave circuitry as well as the supporting membrane for the Transition-Edge Sensor (TES) bolometers. The orthomode transducer (OMT) is realized as a symmetric structure and on-chip filters are employed to define the detection bandwidth. A hybridized integrated enclosure reduces the high-frequency THz mode set that can couple to the TES bolometers. An implementation of the detector architecture at Q-band achieves 90% efficiency in each polarization. The design is scalable in both frequency coverage, 30-300 GHz, and in number of detectors with uniform characteristics. Hence, the detectors are desirable for ground-based or space-borne instruments that require large arrays of efficient background-limited cryogenic detectors.

Millimeter-Wave Detectors↗

Fabrication of Ultrasensitive Transition Edge Sensor Bolometric Detectors for HIRMES

The high resolution mid-infrared spectrometer (HIRMES) is a high resolving power (R approx. 100,000) instrument operating in the 25-122 micron spectral range and will fly on board the Stratospheric Observatory for Far-Infrared Astronomy (SOFIA) in 2019. Central ot HIRMES are its two transition edge sensor (TES) bolometric cameras, an 8x16 detector high resolution array and a 64x16 detector low resolution array. Both types of detectors consist of MoAu TES fabricated on leg-isolated Si membranes. Whereas the high resolution detectors, with noise equivalent power (NEP) approx. 2 aW/square root of (Hz), are fabricated on 0.45 micron Si substrates, the low resolution detectors, with NEP approx. 10 aW/square root of (Hz), are fabricated on 1.40 micron Si. Here we discuss the similarities and difference in the fabrication methodologies used to realize the two types of detectors.

Detectors↗

Radiation Effects in CdZnTe Gamma-Ray Detectors Produced by 199 MeV Protons

Many future space missions will use Cadmium Sinc Telluride (CdZnTe) gamma-ray detectors because their operation at room temperature makes compact, lightweight detector systems possible. Even though instruments for space using CdZnTe detectors have already been built, the effect of the high-energy particle space environment on these detectors has not been measured. To determine the effect of energetic charged particles on these detectors, we have bombarded seveal CdZnTe detectors with 199 MeV protons at the Indiana University Cyclotron Facility.

radiation↗

Wide Band Gap Radiation Detectors for Deep Space Science

Understanding how the Sun, Earth, and other objects in the solar system interact with the space radiation environment is crucial for improving activities of humans on Earth and in space. Low-power, low-noise, multidirectional robust detectors for detecting ions with a wide range of mass and energies will provide a more complete understanding of space environment physics. To meet these challenges, new ion detectors based on wide band gap (WBG) semiconductors are being developed for integration on a variety of deep space platforms. NASA Glenn Research Center (GRC) is applying its expertise and facilities in harsh environment instrumentation to develop supporting technologies to enable improved instruments for space science missions. New detector technologies being developed at GRC include SiC solid-state devices as practical robust, thermally stable large area detectors for LET measurements in compact, stacked charged particle telescope. The low-noise, thermally stable nature of the WBG detectors allows a small multidirectional array of charged particle telescopes to be packed in a 6U CubeSat without active cooling for operation in lunar orbit or deep space. Using a full variety of different WBG detectors, an extremely compact instrument to provide multi-directional, comprehensive (composition, velocity, and direction) in-situ measurements of heavy ions in space plasma environments can be realized.

ion detectors↗

Estimation of position resolution for DOI-PET detector using diameter 0.2 mm WLS fibers [ANIMMA--2015-IO-x5]

We have been developing a submillimeter resolution and low-cost DOI-PET detector using wavelength shifting fibers (WLSF), scintillating crystal plates and MPPCs (Hamamatsu Photonics). Conventional design of DOI-PET detectors had approximately mm{sup 3} of resolution by using some scintillating blocks with a volume of 1 mm{sup 3}, which detects gamma-ray. They are expensive due to difficulties in processing scintillating crystals and a large number of photo-detectors, and these technologies are likely to reach the limit of the resolution. Development of a lower cost DOI-PET detector with higher resolution is challenging to popularize the PET diagnosis. We propose two type of PET detector. One is a whole body PET system, and the other is a PET system for brain or small animals. Each PET system consists 6 blocks. The former consists of 6 layers of crystal plates with 300 mm x 300 mm x 4 mm. The latter consists of 16 crystal layers, forming 4 x 4 crystal arrays. The size of the crystal plate is 40 mm x 40 mm x 1 mm. Wavelength shifting fiber (WLSF) sheets are attached to above and up and down side of crystal planes. The whole PET system has 8 MPPCs attached on each side. For the brain PET detector, 9 WLSF fibers are attached on the each side. The expected position resolution would be less than 1 mm at the former system. We have performed an experimental performance estimation for the system component using {sup 22}Na radioactive source. We achieved a collection efficiency of 10% using the WLSF sheet and Ce:Gd{sub 3}(Al,Ga){sub 5}O{sub 12} (GAGG) crystals at 511 keV. The linear relationship between reconstruction position and incident position was obtained, and a resolution of 0.7 mm (FWHM) for x-axis of DOI by the WLSF readout was achieved. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of Electronics Upgrades to the LANL Green is Clean Phoswich Detector Systems - 16419

Los Alamos National Laboratory radiological facilities produce low-density room trash that, in many cases, is not contaminated with radioactivity. It has been estimated that 50 to 90% of low-density room trash is free of radioactive contamination and eligible for inclusion in LANL's Green is Clean (GIC) program. The GIC program is a verification program for non-regulated waste from radiation controlled areas that has been actively segregated as nonradioactive through the use of the waste generator's acceptable knowledge. The GIC program has employed two large area Phoswich gamma ray detector systems (HERCULES and ZEUS) to assay and verify that GIC candidate waste meets free release disposal requirements. The large area (127 cm{sup 2}) Phoswich detectors consist of a thin NaI front crystal (3 mm thick) that is optically coupled to a thick CsI back crystal (50 mm thick). The crystals are set in an oxygen-free high-conductivity copper housing with a very thin (0.025 mm) aluminum entrance window. The scintillation properties of the two crystals are different enough to allow the system's electronic components to identify the origin of any pulse. The original systems utilize Nuclear Instrumentation Module (NIM) electronics to process the detector signals. These electronic modules provide the buffering, amplification, and pulse shape analyzer needed for the proper presentation of signals to the custom Phosmux router module. The router module separates the sodium iodide and cesium iodide signals by their rise times and transfers this information into the computer-mounted multichannel analyzer, a Canberra Model S-100 system. While these NIM Bin counting electronics configurations have been effective for approximately 20 years of operation, they are bulky requiring numerous modules per detector and the important Phosmux module is no longer manufactured by LANL. Modern advancement of commercial counting electronics now offer more compact options for equivalent detector signal processing. A pulse shape discriminator module, the DGF Pixie-4, made by XIA LLC, has been identified that can replace the majority of the original NIM bin electronics in a much more compact chassis - one Pixie-4 replaces four NIM amplifiers and four NIM PSAs and fits in a small National Instruments{sup TM} chassis. Thus, LANL has initiated a system upgrade project to replace the historic NIM electronics with the XIA Pixie4 and associated configuration software. The hardware for one Phoswich systems has been procured for the project and the configuration software, customized for the LANL Phoswich detector application, has been written by the manufacturer. Initial setup and optimization of the Pixie-4 configuration has been performed. Qualitative and quantitative baseline comparisons to the NIM electronics has been performed. Good agreement of key low energy gamma lines between the systems has allowed 'Proof of Concept' to be concluded. Further optimization and performance evaluations are in progress. Modifications to the LabVIEW{sup TM} based operating software (originally written by VI Control Systems Ltd.) are being performed by a LANL LabVIEW{sup TM} programmer to accommodate the electronics upgrade. A new LabVIEW{sup TM} interface to control the Pixie-4 has already been developed. Final optimization and testing, formal software QA, and revisions to operating procedures are in progress to achieve completion of the GIC system upgrade project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Techniques for LiInSe{sub 2} Semiconducting Neutron Detector - Paper 55

As the world supply of helium continues to dwindle, alternatives to neutron detection have been a key focus area of radiation detection research. Solid-state neutron detectors are one possible alternative to the {sup 3}He detectors currently used for neutron detection when large detector areas are not required. Although {sup 6}Li and {sup 10}B are both also commonly used for neutron detection, neither has as high of a thermal cross section as {sup 3}He. The thermal cross sections for {sup 6}Li, {sup 10}B, and {sup 3}He are, respectively, 940 barns, 3840 barns, and 5330 barns. Both boron and helium are used in a gaseous form for neutron detection; however, there is no suitable gaseous form of lithium for neutron detection. Lithium is instead utilized in solid or liquid compounds for neutron detection. In this context, one area of interest is in the development of ternary A{sup I}B{sup III}C{sup IV} semiconductors comprised of isotopically-enriched lithium. Single crystal samples are being prepared through collaboration with the Y12 National Security Complex. This research focuses on the characterization of {sup 6}LiInSe{sub 2} (LISe) crystals, as well as on the development of prototype systems to assess the viability of using LISe crystals as a thermal neutron detector. Data to be obtained will provide previously untested physical parameters to facilitate growth optimization. Eventually, the refined crystals will be developed into solid-state, position-sensitive pixel detectors used for neutron imaging, among a wide array of possible applications including nuclear forensics. For the most part, the research team has been focused on mastering the detector fabrication processes, response tests on the first two batches of crystal samples, and the design of the first iteration detection system (Fig. 2). Response tests using alphas and neutrons have shown sensitivity to both particles. The first iteration detection system developed utilizes a 3-stage filter ladder of resistors and capacitors, similar to an ORTEC 142PC Preamplifier. Ideally, this ladder will reduce the noise associated with the high voltage power supply. The preamplifier is AC coupled to improve its counting rate capability (saturation), and critical components are on insulated posts. The custom circuit is housed in an aluminum box, and initial testing of the circuit has shown expected results. Investigation into further noise reduction is underway and will be the focus of the presented results. Upon completion and successful testing of the final detection system design, further development in spatial resolution and gamma/neutron discrimination will continue. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact E ? B microchannel plate detector for beam imaging

A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E×B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in one-dimension. To assess the spatial resolution, the detector was illuminated by an α-source with an intervening mask that consists of a series of precisely-machined slits. The measured spatial resolution was 520 um source FWHM, which was improved to 413 um FWHM by performing an FFT of the signals, rejecting spurious signals on the delay line, and requiring a minimum signal amplitude. This measured spatial resolution of 413 um FWHM corresponds to an intrinsic resolution of 334 um FWHM when the effect of the finite slit width is de-convoluted. To understand the measured resolution, the performance of the detector is simulated with the ion-trajectory code SIMION.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using 3D position sensitivity to reveal response non-uniformities in CdZnTe, TlBr, and CsPbBr 3 detectors

Position sensitivity enables the correction of response non-uniformities in room-temperature semiconductor detectors caused by crystal defects and other factors. It can also be used to pinpoint the exact location of crystal defects responsible for the response variations. This work describes a technique for revealing and visualizing the detector regions affecting the charge collection efficiency in CdZnTe (CZT), TlBr, and CsPbBr 3 detectors configured as position-sensitive virtual Frisch-grid (VFG) devices. The technique correlates the photopeak events in energy spectra with their spatial distributions inside the detectors using the position information. By selecting the events from narrow energy intervals within a photopeak, we can visualize the detector volumes with particular charge collection efficiencies, which, in turn, correlate with the locations of electrode and crystal defects. Here, we demonstrate this technique in several examples. Columnar structures in the volume plots (position distribution maps) are consistent with signal losses near or at the anode in selected samples of CZT and TlBr. Structures exhibiting a distinct depth dependence are consistent with grain boundaries or other crystal defects.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors

Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.

47 OTHER INSTRUMENTATION↗

A review of advances in pixel detectors for experiments with high rate and radiation

The large Hadron collider (LHC) experiments ATLAS and CMS have established hybrid pixel detectors as the instrument of choice for particle tracking and vertexing in high rate and radiation environments, as they operate close to the LHC interaction points. With the high luminosity-LHC upgrade now in sight, for which the tracking detectors will be completely replaced, new generations of pixel detectors are being devised. They have to address enormous challenges in terms of data throughput and radiation levels, ionizing and non-ionizing, that harm the sensing and readout parts of pixel detectors alike. Advances in microelectronics and microprocessing technologies now enable large scale detector designs with unprecedented performance in measurement precision (space and time), radiation hard sensors and readout chips, hybridization techniques, lightweight supports, and fully monolithic approaches to meet these challenges. In conclusion, this paper reviews the world-wide effort on these developments.

47 OTHER INSTRUMENTATION↗

Characterisation of the high dynamic range Large Pixel Detector (LPD) and its use at X-ray free electron laser sources

The STFC Rutherford Appleton Laboratory have delivered the Large Pixel Detector (LPD) for MHz frame rate imaging at the European XFEL. The detector system has an active area of 0.5 m × 0.5 m and consists of a million pixels on a 500 μm pitch. Sensors have been produced from 500 μm thick Hammamatsu silicon tiles that have been bump bonded to the readout ASIC using a silver epoxy and gold stud technique. Each pixel of the detector system is capable of measuring 10 5 12 keV photons per image readout at 4.5 MHz. In this paper results from the testing of these detectors at the Diamond Light Source and the Linac Coherent Light Source (LCLS) are presented. As a result, the performance of the detector in terms of linearity, spatial uniformity and the performance of the different ASIC gain stages is characterised.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗