Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DEMONSTRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Demonstration of a viable quantitative theory for interplanetary type II radio bursts

Between 29 November and 1 December 2013 the two widely separated spacecraft STEREO A and B observed a long lasting, intermittent, type II radio burst for the extended frequency range ≈ 4 MHz to 30 kHz, including an intensification when the shock wave of the associated coronal mass ejection (CME) reached STEREO A. We demonstrate for the first time our ability to quantitatively and accurately simulate the fundamental (F) and harmonic (H) emission of type II bursts from the higher corona (near 11 solar radii) to 1 AU. Our modeling requires the combination of data-driven three-dimensional magnetohydrodynamic simulations for the CME and plasma background, carried out with the BATS-R-US code, with an analytic quantitative kinetic model for both F and H radio emission, including the electron reflection at the shock, growth of Langmuir waves and radio waves, and the radiations propagation to an arbitrary observer. The intensities and frequencies of the observed radio emissions vary hugely by factors ≈ 10{sup 6} and ≈ 10{sup 3}, respectively; the theoretical predictions are impressively accurate, being typically in error by less than a factor of 10 and 20 %, for both STEREO A and B. We also obtain accurate predictions for the timing and characteristics of the shock and local radio onsets at STEREO A, the lack of such onsets at STEREO B, and the z-component of the magnetic field at STEREO A ahead of the shock, and in the sheath. Very strong support is provided by these multiple agreements for the theory, the efficacy of the BATS-R-US code, and the vision of using type IIs and associated data-theory iterations to predict whether a CME will impact Earth’s magnetosphere and drive space weather events.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chemical detection demonstrated using an evanescent wave graphene optical sensor

Graphene devices have been constructed on silicon mirrors, and the graphene is optically probed through an evanescent wave interaction in an attenuated total reflectance configuration using an infrared spectrometer. The graphene is electrically biased in order to tune its optical properties. Exposure of the device to the chemicals iodine and ammonia causes observable and reversible changes to graphene's optical absorption spectra in the mid to near infrared range which can be utilized for the purpose of sensing. Electrical current measurements through the graphene are made simultaneously with optical measurements allowing for simultaneous sensing using two separate detection modalities. Our current results reveal sub-ppm detection limits for iodine and approximately 100 ppm detection limits for ammonia. We have also demonstrated that this approach will work at 1.55 μm, which opens up the possibility for graphene optical sensors that leverage commercial telecom light sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An adaptable dual species effusive source and Zeeman slower design demonstrated with Rb and Li

We present a dual-species effusive source and Zeeman slower designed to produce slow atomic beams of two elements with a large mass difference and with very different oven temperature requirements. We demonstrate this design for the case of {sup 6}Li and {sup 85}Rb and achieve magneto-optical trap (MOT) loading rates equivalent to that reported in prior work on dual species (Rb+Li) Zeeman slowers operating at the same oven temperatures. Key design choices, including thermally separating the effusive sources and using a segmented coil design to enable computer control of the magnetic field profile, ensure that the apparatus can be easily modified to slow other atomic species. By performing the final slowing using the quadrupole magnetic field of the MOT, we are able to shorten our Zeeman slower length making for a more compact system without compromising performance. We outline the construction and analyze the emission properties of our effusive sources. We also verify the performance of the source and slower, and we observe sequential loading rates of 12 × 10{sup 8} atoms/s for a Rb oven temperature of 140 °C and 1.1 × 10{sup 8} atoms/s for a Li reservoir at 460 °C, corresponding to reservoir lifetimes for continuous operation of 10 and 4 years, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstration of acoustic waveguiding and tight bending in phononic crystals

The systematic design, fabrication, and characterization of an isolated, single-mode, 90° bend phononic crystal (PnC) waveguide are presented. A PnC consisting of a 2D square array of circular air holes in an aluminum substrate is used, and waveguides are created by introducing a line defect in the PnC lattice. A high transmission coefficient is observed (–1 dB) for the straight sections of the waveguide, and an overall 2.3 dB transmission loss is observed (a transmission coefficient of 76%) for the 90° bend. Further optimization of the structure may yield higher transmission efficiencies. Lastly, this manuscript shows the complete design process for an engineered 90° bend PnC waveguide from inception to experimental demonstration.

36 MATERIALS SCIENCE↗

Experimental demonstration of 55-fs spin canting in photoexcited iron nanoarrays

As magnetic storage density approaches 1TB/in 2 , a grand challenge is looming as how to read/write such a huge amount of data within a reasonable time. The ultrafast optical manipulation of magnetization offers a solution, but little is known about the intrinsic speed limit of quantum spin switching. Here, we report that low-energy 50-fs laser pulses can induce spin canting in Fe nanoparticles within 55 fs, breaking the previous record by at least one order of magnitude. Both linearly and circularly polarized light can be used to tilt spins. In our model, the incident laser field first excites the orbital angular momentum, and through spin-orbit coupling, the spin cants out-of-plane and results in a distinctive diamond hysteresis loop. The spin canting time decreases with spin angular momentum. This spin canting is not limited to Fe nanoparticles and is also observed in Fe/ Pt and Fe 3 O 4 nanoparticles. Lastly, our results demonstrate the potential of magnetic nanostructures as a viable magnetic medium for high density and fast-switching magnetic storage devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Initial experimental demonstration of the principles of a xenon gas shield designed to protect optical components from soft x-ray induced opacity (blanking) in high energy density experiments

The design principles of a xenon gas shield device that is intended to protect optical components from x-ray induced opacity (“x-ray blanking”) have been experimentally demonstrated at the OMEGA-60 Laser Facility at the Laboratory for Laser Energetics, University of Rochester. A volume of xenon gas placed in front of an optical component absorbs the incoming soft x-ray radiation but transmits optical and ultra-violet radiation. The time-resolved optical (532 nm) transmission of samples was recorded as they were exposed to soft x-rays produced by a gold sphere source (1.5 kJ sr $-$1 , 250–300 eV). Blanking of fused silica (SiO 2 ) was measured to occur over a range of time-integrated soft x-ray (<3 keV) fluence from ~0.2–2.5 J cm $-$2 . A shield test device consisting of a 30 nm silicon nitride (Si 3 N 4 ) and a 10 cm long volume of 0.04 bar xenon gas succeeded in delaying loss of transmission through a magnesium fluoride sample; optical transmission was observed over a longer period than for the unprotected sample. It is hoped that the design of this x-ray shield can be scaled in order to produce a shield device for the National Ignition Facility optical Thomson scattering collection telescope, in order to allow measurements of hohlraum plasma conditions produced in inertial confinement fusion experiments. Finally, if successful, it will also have applications in many other high energy density experiments where optical and ultra-violet measurements are desirable.

42 ENGINEERING↗

Numerical modeling of laser-driven experiments aiming to demonstrate magnetic field amplification via turbulent dynamo

The universe is permeated by magnetic fields, with strengths ranging from a femtogauss in the voids between the filaments of galaxy clusters to several teragauss in black holes and neutron stars. The standard model behind cosmological magnetic fields is the nonlinear amplification of seed fields via turbulent dynamo to the values observed. We have conceived experiments that aim to demonstrate and study the turbulent dynamo mechanism in the laboratory. Here, we describe the design of these experiments through simulation campaigns using FLASH, a highly capable radiation magnetohydrodynamics code that we have developed, and large-scale three-dimensional simulations on the Mira supercomputer at the Argonne National Laboratory. The simulation results indicate that the experimental platform may be capable of reaching a turbulent plasma state and determining the dynamo amplification. As a result, we validate and compare our numerical results with a small subset of experimental data using synthetic diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cavity resonator for dielectric measurements of high-ε, low loss materials, demonstrated with barium strontium zirconium titanate ceramics

A resonant cavity method is presented which can measure loss tangents and dielectric constants for materials with dielectric constant from 150 to 10 000 and above. This practical and accurate technique is demonstrated by measuring barium strontium zirconium titanate bulk ferroelectric ceramic blocks. Above the Curie temperature, in the paraelectric state, barium strontium zirconium titanate has a sufficiently low loss that a series of resonant modes are supported in the cavity. At each mode frequency, the dielectric constant and loss tangent are obtained. The results are consistent with low frequency measurements and computer simulations. A quick method of analyzing the raw data using the 2D static electromagnetic modeling code SuperFish and an estimate of uncertainties are presented.

Marksteiner, Quinn R.↗

Experimental demonstration of a single-spike hard-X-ray free-electron laser starting from noise

In this letter, we report the experimental demonstration of single-spike hard-X-ray free-electron laser pulses starting from noise with multi-eV bandwidth. Here, this is accomplished by shaping a low-charge electron beam with a slotted emittance spoiler and by adjusting the transport optics to optimize the beam-shaping accuracy. Based on elementary free-electron laser scaling laws, we estimate the pulse duration to be less than 1 fs full-width at half-maximum.

43 PARTICLE ACCELERATORS↗

Experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum tube

Here, we report the experimental demonstration of a 5th harmonic mm-wave frequency multiplying vacuum electronic device, which uses an over-moded spherical sector output cavity. In this device, a pencil electron beam is helically deflected in a transverse deflecting cavity before entering the output cavity. No magnetic field is required to focus or guide the beam. We built and tested a proof-of-principle device with an output frequency of 57.12 GHz. The measured peak power was 52.67 W at the 5th harmonic of the drive frequency. Power at the 4th, 6th, and 7th harmonics was 33.28 dB lower than that at the 5th harmonic.

43 PARTICLE ACCELERATORS↗

Demonstration of fast-electron populations in a low-pressure, low-power, magnetized RF plasma source

Using x-ray spectroscopy, we demonstrate the existence of 0.3–6 keV electrons in a low-pressure, low-power, magnetized plasma source, heated by an external radio-frequency antenna located at one end of an axisymmetric tandem mirror. X-ray measurements on low-bulk-temperature, T e,b ~ 4 eV, hydrogen, neon, argon, and gas-mixture plasmas show spectra with high-energy tails having a near-Maxwellian form with T e,f up to 650 eV. Furthermore, the fast electrons producing these x-rays have densities in the range of 10 7 –10 9 cm –3 0.01%–1% of the bulk plasma density (up to 3 × 10 11 cm –3 ), and so carry a significant fraction of the plasma energy and represent an important mechanism relevant to power coupling and heat flow in similar plasma sources.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

Here, developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C 60 , AlPcCl:C 70 , and P3HT:PC 61 BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.28 µGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy -1 cm -2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

36 MATERIALS SCIENCE↗

Demonstration of a chamber for strain mapping of steel specimens under mechanical load in a hydrogen environment by synchrotron radiation

Here, we demonstrate a hydrogen gas chamber suitable for lattice strain measurements and capturing radiographs of a steel specimen under a mechanical load using high energy synchrotron x-rays. The chamber is suitable for static and cyclic mechanical loading. Experiments were conducted at the 1-ID-E end station of the Advanced Photon Source, Argonne National Laboratory. Diffraction patterns show a high signal-to-noise ratio suitable for lattice strain measurements for the specimen and with minimal scattering and overlap from the gas chamber manufactured from aluminum. In situ radiographs of a specimen in the hydrogen chamber show the ability to track a growing crack and to map the lattice strain around the crack with high spatial and strain resolution.

47 OTHER INSTRUMENTATION↗

First demonstration of improved capsule implosions by reducing radiation preheat in uranium vs gold hohlraums

In indirectly-driven Inertial Confinement Fusion (ICF) implosions, supra-thermal M-band (>2 keV) radiation from principally 4–3 resonance line transitions generated during laser irradiation at the peak power of Au hohlraum walls can preheat the fusion capsule and reduce compressional pressure. Higher Z, un-lined depleted uranium (DU) hohlraums were used for the first time in ICF implosions on the National Ignition Facility (NIF) to reduce M-band radiation levels while keeping the total radiation flux similar to Au hohlraums. First implosions in DU demonstrate an increase in in-flight density (+15%) of high density carbon capsules, and hence in stagnated hot spot temperature (+15%), hot spot x-ray (+200%) and fusion neutron yields (+100%) compared to Au hohlraums. We show analytically that these changes are consistent with the observed 40% reduction in M-band x-ray flux in DU, and are in agreement with 2D hydrodynamic simulations. This result had a major impact on ICF research on the NIF where a significant fraction of high neutron yield implosions are currently using un-lined DU hohlraums.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of femtosecond X-ray pump X-ray probe diffraction on protein crystals

The development of X-ray free-electron lasers (XFELs) has opened the possibility to investigate the ultrafast dynamics of biomacromolecules using X-ray diffraction. Whereas an increasing number of structures solved by means of serial femtosecond crystallography at XFELs is available, the effect of radiation damage on protein crystals during ultrafast exposures has remained an open question. We used a split-and-delay line based on diffractive X-ray optics at the Linac Coherent Light Source XFEL to investigate the time dependence of X-ray radiation damage to lysozyme crystals. For these tests, crystals were delivered to the X-ray beam using a fixed-target approach. The presented experiments provide probe signals at eight different delay times between 19 and 213 femtoseconds after a single pump event, thereby covering the time-scales relevant for femtosecond serial crystallography. Even though significant impact on the crystals was observed at long time scales after exposure with a single X-ray pulse, the collected diffraction data did not show significant signal reduction that could be assigned to beam damage on the crystals in the sampled time window and resolution range. This observation is in agreement with estimations of the applied radiation dose, which in our experiment was clearly below the values expected to cause damage on the femtosecond time scale. The experiments presented here demonstrate the feasibility of time-resolved pump-multiprobe X-ray diffraction experiments on protein crystals.

43 PARTICLE ACCELERATORS↗

Experimental Demonstration of a Latent Heat Storage System for Dispatchable Electricity

Modern electric grids that use intermittent renewables require energy storage to maintain reliability. Many potential solutions exist, but latent heat thermal energy storage shows particularly high potential for low cost grid scale energy storage. In this paper, we present the design and initial experimental results for a lab-scale prototype of a novel latent heat thermal storage system. This version of our prototype used 50 kg of aluminum-silicon alloy as a phase change material, and a novel valved thermosyphon concept to control heat flow from a thermal storage tank to thermoelectric generators for dispatchable electricity production. Our results validate the system: the thermal storage system was able to receive heat input, evenly distribute heat to and from the phase change material with small temperature gradients, and controllably dispatch heat to a heat engine for electricity generation on demand. With the basic principle of this technology demonstrated, our next step will be to evaluate and improve system efficiency.

14 SOLAR ENERGY↗

A neutron diffraction demonstration of long-range magnetic order in the quasicrystal approximant DyCd 6

We have used neutron powder diffraction to demonstrate the existence of long-range antiferromagnetic order of Ising-like Dy moments in the DyCd 6 quasicrystal approximant phase. This cubic compound undergoes a slight distortion to a monoclinic cell at low temperatures. The Néel temperature is 18.0(2) K and the magnetic order of the Dy sublattice may be described in the parent cubic Im 3¯ structure using a combination of two propagation vectors, k 1 = [0 0 0] and k 2 = [1/2 0 1/2], yielding ‘anti-I’ order. Furthermore, when referred to the monoclinic C 2/ c cell, the magnetic structure may be described by a single propagation vector: k = [1 0 0].

36 MATERIALS SCIENCE↗

Demonstration of distributed capacitance compensation in a metal-insulator-metal infrared rectenna incorporating a traveling-wave diode

We experimentally demonstrate that the transmission line impedance of traveling-wave diodes can circumvent resistance-capacitance time-constant limitations of metal-insulator-metal diodes in rectennas operating at optical frequencies. We fabricated low resistance (380 Ω ) and moderate responsivity (0.46 A/W) metal-insulator-metal traveling-wave diodes. When a rectenna incorporating the traveling-wave diode was illuminated with 10.6 μ m radiation, it produced a peak system responsivity of 130 μ A/W and a detectivity of 1.0 × 10 4 Jones. These results agree with the simulated device performance and exceed the response of an equivalent lumped-element metal-insulator-metal rectenna.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗