Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Measurement of the LCLS-II dark current using the LDMX Trigger Scintillator Prototype

The Light Dark Matter eXperiment (LDMX) is a proposed fixed-target missing momentum search for sub-GeV thermal relic dark matter. LDMX aims to probe thermal dark matter targets with 1016 electrons on target. Such an approach requires a high-repetition rate, low-current beam, with an average of one electron on target per event. These requirements are well-suited to the DArk Sector Experiments at LCLS-II (DASEL) facility, which will take advantage of the unused RF buckets between LCLS-II bunches to produce a well-defined low-current beam with a 26.9 ns bunch spacing. This document describes the results of a measurement of dark current in the Sector 30 transfer line (S30XL) of the LCLS-II beam, using a prototype of the LDMX trigger scintillator (TS) subsystem.

Berzin, Elizabeth [SLAC]↗

H II regions in the dwarf galaxy UGC-A 86

The uncertain nature of the dwarf irregular galaxy UGC-A 86 (VIIZw009) makes it a very interesting object for studying star formation at the low end of the galaxy luminosity function. Saha and Hoessel (1991) find that this object is composed of two main parts, one of which appears more resolved than the other. The more resolved component has an excess of blue stars, suggesting that it is currently undergoing star formation. Thus, they argue that UGC-A 86 could be either a superposition of unrelated galaxies, two interacting galaxies, or a single galaxy. However, surface photometry performed by Richter et al. (1991) indicates that it is a single galaxy with an exponential luminosity profile. Richter et al. also find UGC-A 86 to be extremely dusty and to be associated with the infrared source IRAS 3550+6657. The uncertainty is compounded by the large ambiguity in the distance, though a heliocentric H1 velocity of 80 plus or minus 7 km s(sup -1) suggests that it is either a member of the Local Group or perhaps the IC 342 group. A distance of 1.5 Mpc and a reddening of E(B - V) = 0.65 is adopted. UGC-A 86 in H-alpha was observed in order to measure its current star formation rate. This is part of a larger project to study the star formation rates and histories of a complete sample of dwarf galaxies in the Local Group and other nearby groups. The H region luminosity function and size distribution for UGC-A 86 are presented and compared with previous observations of similar dwarf galaxies.

Miller, Bryan W.↗

Calibration of the NOAA 11 solar backscatter ultraviolet (SBUV/2) ozone data set from 1989 to 1993 using in-flight calibration data and SSBUV

Total ozone and ozone profiles are currently being measured by solar backscatter ultraviolet (SBUV/2) instruments onboard NOAA polar orbiting spacecraft using the backscattered ultraviolet technique. The NOAA 11 SBUV/2 operational data set, reprocessed from January 1989 to May 1993 (version 6), includes an updated algorithm and revised prelaunch and postlaunch calibrations of the geometrical albedo observations used to derive ozone values. The postlaunch calibration revisions remove time dependent errors in the ozone amounts due to instrument drift, while the revised prelaunch calibration corrects the absolute value of retrieved ozone. The prelaunch corrections are a result of calibration checks from in-orbit comparisons of ultraviolet geometric albedos measured by shuttle SBUV (SSBUV) and the NOAA 11 SBUV/2. Geometric albedo comparison data are further corrected using a radiative transfer code to account for the small difference in observing conditions between the two spacecraft. The postlaunch corrections rely on in-flight calibration and solar irradiance data to account for time dependent changes in instrument gain, thermal response, and instrument diffuser degradation over time. Comparison of data from three SSBUV flights, which occurred about one year apart, with concurrent SBUV/2 data provided an independent check of the time dependent change derived from the in-flight calibration data. Time independent corrections result in an increase of about 1% for total ozone, 5% for ozone at 1 mbar, and near 0% at 15 mbar. The time dependent corrections amount to an increase of 2% for total ozone, 10% for ozone near 1 mbar, and 3% at 15 mbar at the end of the current record in May 1993. Recent laboratory studies indicate that the absolute radiance calibrations may still be in error by a few percent which results in ozone profile values that are too low. The SBUV/2 total and ozone profile data are compared to the Nimbus SBUV data during the period when the data overlapped. Total ozone values agree to about 1%, while ozone profile differences range from -4% to +6%, depending on latitude and altitude, relative to SBUV. These differences are not statistically significant given the uncertainties of the two data sets.

Hilsenrath, E.↗

Using Light Curves to Characterize Size and Shape of Pseudo-Debris

Photometric measurements were collected for a new study aimed at estimating orbital debris sizes based on object brightness. To obtain a size from optical measurements the current practice is to assume an albedo and use a normalized magnitude to calculate optical size. However, assuming a single albedo value may not be valid for all objects or orbit types; material type and orientation can mask an object s true optical cross section. This experiment used a CCD camera to record data, a 300 W Xenon, Ozone Free collimated light source to simulate solar illumination, and a robotic arm with five degrees of freedom to move the piece of simulated debris through various orientations. The pseudo-debris pieces used in this experiment originate from the European Space Operations Centre s ESOC2 ground test explosion of a mock satellite. A uniformly illuminated white ping-pong ball was used as a zero-magnitude reference. Each debris piece was then moved through specific orientations and rotations to generate a light curve. This paper discusses the results of five different object-based light curves as measured through an x-rotation. Intensity measurements, from which each light curve was generated, were recorded in five degree increments from zero to 180 degrees. Comparing light curves of different shaped and sized pieces against their characteristic length establishes the start of a database from which an optical size estimation model will be derived in the future.

Rodriquez, Heather M.↗

Noise dynamics of quantum annealers: estimating the effective noise using idle qubits

Quantum annealing is a type of analog computation that aims to use quantum mechanical fluctuations in search of optimal solutions of QUBO (quadratic unconstrained binary optimization) or, equivalently, Ising problems. Since NP-hard problems can in general be mapped to Ising and QUBO formulations, the quantum annealing paradigm has the potential to help solve various NP-hard problems. Current quantum annealers, such as those manufactured by D-Wave Systems, Inc. have various practical limitations including the size (number of qubits) of the problem that can be solved, the qubit connectivity, and error due to the environment or system calibration, which can reduce the quality of the solutions. Typically, for an arbitrary problem instance, the corresponding QUBO (or Ising) structure will not natively embed onto the available qubit architecture on the quantum chip. Thus, in these cases, a minor embedding of the problem structure onto the device is necessary. However, minor embeddings on these devices do not always make use of the full sparse chip hardware graph, and a large portion of the available qubits stay unused during quantum annealing. In this work, we embed a disjoint random QUBO on the unused parts of the chip alongside the QUBO to be solved, which acts as an indicator of the solution quality of the device over time. Using experiments on three different D-Wave quantum annealers, we demonstrate that (i) long term trends in solution quality exist on the D-Wave device, and (ii) the unused qubits can be used to measure the current level of noise of the quantum system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BICEP/ Keck XVIII: Measurement of BICEP3 polarization angles and consequences for constraining cosmic birefringence and inflation

We use a custom-made calibrator to measure individual detectors’ polarization angles of BICEP3, a small aperture telescope observing the cosmic microwave background (CMB) at 95 GHz from the South Pole. We describe our calibration strategy and the statistical and systematic uncertainties associated with the measurement. We reach an unprecedented precision for such measurement on a CMB experiment, with a repeatability for each detector pair of 0.02°. Here, we show that the relative angles measured using this method are in excellent agreement with those extracted from CMB data. Because the absolute measurement is currently limited by a systematic uncertainty, we do not derive cosmic birefringence constraints from BICEP3 data in this work. Rather, we forecast the sensitivity of BICEP3 sky maps for such analysis. We investigate the relative contributions of instrument noise, lensing, and dust, as well as astrophysical and instrumental systematics. We also explore the constraining power of different angle estimators, depending on analysis choices. We establish that the BICEP3 2-year dataset (2017–2018) has an on-sky sensitivity to the cosmic birefringence angle of 𝜎 𝛼 = 0.07⁢8°, which could be improved to 𝜎 𝛼 = 0.05⁢5° by adding all of the existing BICEP3 data (through 2023). Furthermore, we emphasize the possibility of using the BICEP3 sky patch as a polarization calibration source for CMB experiments, which with the present data could reach a precision of 0.035°. Finally, in the context of inflation searches, we investigate the impact of detector-to-detector variations in polarization angles as they may bias the tensor-to-scalar ratio 𝑟. We show that while the effect is expected to remain subdominant to other sources of systematic uncertainty, it can be reliably calibrated using polarization angle measurements such as the ones we present in this paper.

Cosmic microwave background↗

Multi-technique characterization of iron reduction by an Antarctic Shewanella : an analog system for putative Martian biosignature identification

ABSTRACT Microbes from terrestrial extreme environments enable testing of biosignature production in conditions relevant to astrobiological targets. Mars, which was likely more conducive to life during early warmer and wetter epochs, has inspired missions that search for signs of early life in the surficial rock record, including mineral or organic biosignatures. Microbial iron reduction is a common and ancient metabolism that may have also operated on other rocky celestial bodies. To investigate biosignature production during iron reduction, aShewanellasp. (strain BF02_Schw) isolated from a subglacial discharge known as Blood Falls, Antarctica, was incubated with the electron acceptor ferrihydrite (Fh). Biosignatures associated with Fh reduction were identified using a suite of techniques currently utilized or proposed for Mars missions, including X-ray diffraction and infrared, Mössbauer, and Raman spectroscopy. The biotic origin of features was validated by transcriptional changes observed between treatments with and without Fh and comparison to killed controls. In live treatments, Fh was reduced to magnetite and goethite, both detected in Martian lacustrine basins. Several soluble and volatile metabolites were also detected, including riboflavin and dimethyl sulfide (DMS), which could be astrobiological indicators of active microbial processes. While none of the identified biosignatures individually would serve as definitive proof of life (past or present), detecting concomitant features associated with known terrestrial biotic processes would provide compelling rationale for more targeted life detection missions. Terrestrial extremophiles can support the exploration of astrobiologically relevant microbial processes, validation of life detection instrumentation, and potentially the discovery of new biomarkers. IMPORTANCE Culture-based experiments with terrestrial extremophiles can elucidate biosignatures that may be analogous to those produced under extraterrestrial conditions, and thus inform sampling and technology strategies for future missions. Here, we demonstrate the production of several biosignatures under iron-reducing conditions byShewanellasp. BF02_Schw, originally isolated from an Antarctic analog feature. These biosignatures could be detectable using flight-ready instrumentation. Growth experiments with terrestrial extremophiles can identify biosignatures measurable by current methodologies and inform the development and optimization of techniques for detecting extant or extinct life on other worlds.

Biotechnology & Applied Microbiology↗

Variations in the electrical short-circuit current decay for recombination lifetime and velocity measurements

An improved measurement system for electrical short-circuit current decay is presented that extends applicability of the method to silicon solar cells having an effective lifetime as low as 1 microsec. The system uses metal/oxide/semiconductor transistors as voltage-controlled switches. Advances in theory developed here increase precision and sensitivity in the determination of the minority-carrier recombination lifetime and recombination velocity. A variation of the method, which exploits measurements made on related back-surface field and back-ohmic contact devices, further improves precision and sensitivity. The improvements are illustrated by application to 15 different silicon solar cells.

Jung, Tae-Won↗

Investigation of defects in melt and solution grown perovskite CsPbBr 3 single crystals

Recently, there has been considerable interest in x-ray and gamma ray detectors with large volume and high energy resolution that operate at room temperature. To improve detector energy resolution, the carrier mobility-lifetime product needs to be increased, and the electronic trap state concentration needs to be minimized. Defect concentrations in the part per billion range can alter the charge transport and carrier recombination lifetime. In this work, thermally stimulated current spectroscopy measurements were systematically carried out in bulk halide perovskite single crystals of CsPbBr 3 over a temperature range of 80–320 K. The origins and trap parameters of CsPbBr 3 crystals from the solution growth and melt growth procedures were determined and compared. Trap concentrations were ranged from 1 × 10 11 to 1 × 10 16 cm –3 . Appreciable detector performance was observed for CsPbBr3 crystals with trap concentrations less than 1 × 10 14 cm –3 . The comparison of spectral responses of crystal samples grown using two different methods shows that, after purification, solution-grown crystals are comparable to melt-grown crystals in terms of low defect concentration and improved detector performance. Finally, for an improved mobility-lifetime product and enhanced spectral response to high energy radiation from fissile materials, trap states in either type of a crystal ingot must be reduced closer to 10 11 cm –3 .

36 MATERIALS SCIENCE↗

Measurement of neutrino-induced neutral-current coherent $π^0$ production in the NOvA near detector

The cross section of neutrino-induced neutral-current coherent $\pi^0$ production on a carbon-dominated target is measured in the NOvA near detector. This measurement uses a narrow-band neutrino beam with the average neutrino energy of 2.7\,GeV, xwhich is of interest to the ongoing and future long-baseline neutrino oscillation experiments. The measured, flux-averaged cross section is $\sigma = 14.0\pm0.9$\,(stat.)$\pm2.1$\,(syst.)$\times 10^{-40}$ $\text{cm}^2/$nucleus, consistent with model prediction. This result is the most precise measurement of neutral-current coherent $\pi^0$ production in the few-GeV neutrino energy region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Trap Passivation for Reducing On-Resistance and Saturation Voltage in Wafer-Bonded InGaAs-Channel/GaN-Drain Vertical FETs

High frequency and high power are the driving forces behind semiconductor transistor technology. However, conventional devices have the tradeoff of either being high speed or high breakdown—but not both. Wafer-bonded current aperture vertical electron transistors (BAVETs) help eliminate the tradeoff by combining a high-speed III-As channel to a high-breakdown III-N drift region. The device presented herein comprises of an InAlAs gate-barrier/InGaAs channel, wafer-bonded to an InGaN/GaN drift region, with the InGaAs/InGaN interface referred to as the wafer-bonded interface (WBI). The electronic behavior of WBIs is yet less known but necessary in realizing the potential of a BAVET. Herein, strong trap activity at the WBI is shown to be the cause of abnormally high saturation voltage ( V DS_SAT ) in BAVETs. The traps cause unintentional space charge (SC) region in the drain region of the device. This causes a drain resistance, a higher ON-resistance ( R ON ), and a higher V DS_SAT . Here, the challenge is overcome by hydrogen passivation of traps at WBI by using a p-doping for the InAlAs layer, which reduces the trap-charge concentration at the WBI. Consequently, the width of the SC region is reduced and a reduction in V DS_SAT is demonstrated, wherein it reduces from >12 to 5 V.

36 MATERIALS SCIENCE↗

Planck 2018 results

We report on the implications for cosmic inflation of the 2018 release of the Planck cosmic microwave background (CMB) anisotropy measurements. The results are fully consistent with those reported using the data from the two previous Planck cosmological releases, but have smaller uncertainties thanks to improvements in the characterization of polarization at low and high multipoles. Planck temperature, polarization, and lensing data determine the spectral index of scalar perturbations to be n s = 0.9649 ± 0.0042 at 68% CL. We find no evidence for a scale dependence of n s , either as a running or as a running of the running. The Universe is found to be consistent with spatial flatness with a precision of 0.4% at 95% CL by combining Planck with a compilation of baryon acoustic oscillation data. The Planck 95% CL upper limit on the tensor-to-scalar ratio, r0.002 < 0.10, is further tightened by combining with the BICEP2/Keck Array BK15 data to obtain r 0.002 < 0.056. In the framework of standard single-field inflationary models with Einstein gravity, these results imply that: (a) the predictions of slow-roll models with a concave potential, V"(Φ) < 0, are increasingly favoured by the data; and (b) based on two different methods for reconstructing the inflaton potential, we find no evidence for dynamics beyond slow roll. Three different methods for the non-parametric reconstruction of the primordial power spectrum consistently confirm a pure power law in the range of comoving scales 0.005 Mpc -1 ≲ k ≲ 0.2 Mpc -1 . A complementary analysis also finds no evidence for theoretically motivated parameterized features in the Planck power spectra. For the case of oscillatory features that are logarithmic or linear in k, this result is further strengthened by a new combined analysis including the Planck bispectrum data. The new Planck polarization data provide a stringent test of the adiabaticity of the initial conditions for the cosmological fluctuations. In correlated, mixed adiabatic and isocurvature models, the non-adiabatic contribution to the observed CMB temperature variance is constrained to 1.3%, 1.7%, and 1.7% at 95% CL for cold dark matter, neutrino density, and neutrino velocity, respectively. Planck power spectra plus lensing set constraints on the amplitude of compensated cold dark matter-baryon isocurvature perturbations that are consistent with current complementary measurements. The polarization data also provide improved constraints on inflationary models that predict a small statistically anisotropic quadupolar modulation of the primordial fluctuations. However, the polarization data do not support physical models for a scale-dependent dipolar modulation. All these findings support the key predictions of the standard single-field inflationary models, which will be further tested by future cosmological observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Salt Sampling FY21 Technical Report

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches to enable high-precision in-process salt sample analysis to improve the timeliness of sampling-based accountancy measurements. Tools currently under development in support of this goal include (1) a modular vacuum sampler with an accompanying sample handling method for coupling vacuum sampling with high-precision at-line sample analysis, (2) a pneumatic sample generator that enables high-throughput sample analysis to improve the precision of existing analytical techniques, and (3) a windowless flow cell to enable on-line optical analysis of molten salt in a sampling loop. Compared to point sampling approaches (i.e., dip probes), vacuum sampling systems and on-line sampling loops facilitate access to a larger cross-section of a process fluid. This is known to improve the characterization of the process fluid by producing more representative samples and by enabling the analysis of a larger cross section of the fluid. A vacuum sampling approach for molten salts eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. In FY21, two methods for integrating a vacuum sampler with a pneumatic sample generator were tested. These included direct fluidic coupling and coupling using a solid salt transfer mechanism. Solid salt transfer was ultimately selected over fluidic coupling, primarily to enable the transport of samples over longer distances to support automated at-line integration with high-precision techniques (such as microcalorimetry) that cannot withstand the extreme conditions near an electrorefining process. To facilitate rapid solid salt coupling, new mechanisms were developed for rapidly charging and discharging salt sample tubes at the vacuum sampler and pneumatic sample generator, respectively. While the charging mechanism will be deployed in FY22, the tube transfer method and discharge mechanism were tested in FY21. These were deployed at one of Argonne’s engineering-scale electrorefiners to implement at-line high-throughput pneumatic micro-sample generation capabilities. The method was used to generate precise uranium- and lanthanide-bearing electrorefiner micro-samples with the specific dimensions requested by researchers at Los Alamos National Laboratory for use in testing their novel microcalorimeter x-ray techniques. The solid salt transfer mechanism proved not only to be an effective means of integrating the precision sample generator with vacuum sampling, but also improved the performance of the sampler generator. Because the modular sampling approach described here eliminates the need for new high-radiation sample handling capabilities, salt-wetted seals, salt-wetted moving parts, and heated transfer lines outside the electrorefiner, it will address most of the remaining technical challenges for the at-line deployment of high-precision analytical techniques. This will enable significant reductions in the time delay for sampling-based accountancy measurements by eliminating the need for manual off-line sample processing and analysis. On-line optical analysis of molten salt in a sampling loop would provide complementary information to at-line and in-situ techniques. In FY21, an open-aperture molten salt gravity flow cell with windowless optical access to flowing salt was successfully demonstrated. Future work should include the refinement and performance testing of the on-line and at-line sampling tools, integration of additional analysis techniques, stakeholder outreach and collaboration, evaluation of the integrated methods, and analyses to determine how the various tools might fit into an integrated safeguards monitoring system of unattended near real time monitoring tools.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Incoherent scatter measurements of E region conductivities and currents in the auroral zone

Data taken by incoherent scatter radar have been used to investigate ionospheric conductivities and electrical currents. During quiet days, the conductivities appear to vary in a way consistent with ionization arising from solar EUV radiation. In the evening hours, enhancements in the northward electric field are found to precede small increases in the conductivities. Strong enhancements of the Hall conductivity relative to the Pedersen conductivity occur during negative bays when the electric field is in a southwestward direction. The ionospheric currents calculated in the geomagnetic east-west direction are in good agreement with the H component measured by a nearby magnetometer; this result indicates that the current causing the ground level magnetic fluctuations is a broad horizontal sheet current. The north-south ionospheric current, however, consistently disagrees with the observed D component in a manner that cannot easily be explained unless currents parallel to the earth's magnetic field are present.

Brekke, A.↗

3D and Multimodal X‐Ray Microscopy Reveals the Impact of Voids in CIGS Solar Cells

Small voids in the absorber layer of thin-film solar cells are generally suspected to impair photovoltaic performance. They have been studied on Cu(In,Ga)Se 2 cells with conventional laboratory techniques, albeit limited to surface characterization and often affected by sample-preparation artifacts. Here, synchrotron imaging is performed on a fully operational as-deposited solar cell containing a few tens of voids. By measuring operando current and X-ray excited optical luminescence, the local electrical and optical performance in the proximity of the voids are estimated, and via ptychographic tomography, the depth in the absorber of the voids is quantified. Besides, the complex network of material-deficit structures between the absorber and the top electrode is highlighted. Despite certain local impairments, the massive presence of voids in the absorber suggests they only have a limited detrimental impact on performance.

14 SOLAR ENERGY↗

The onset of selective laser flash sintering in undoped and doped lanthanum chromite

Previous studies have shown that selective laser flash sintering (SLFS) can be initiated in dielectrics that exhibit ionic or electronic conduction at high temperature. These materials required high laser powers to reach the temperatures where electrical conduction is sufficient to initiate SLFS. In this study, SLFS in lanthanum chromite (LC), an intrinsic electronic conductor with high conductivity, and lanthanum strontium chromite (LSC), which is doped to further increase electronic conductivity, were investigated with a focus on understanding the initiation mechanisms. Results show that the initiation of SLFS in LC and LSC occurs when electronic charge carriers are activated and flow to the electrode where the current is measured. A combination of carriers produced at the electrode, temperature-activated intrinsic charge carriers, and extrinsic charge carriers present in LSC due to doping are responsible for the facile initiation of SLFS.

36 MATERIALS SCIENCE↗

Electrochemical Degradation Modes in Bifacial Silicon Photovoltaic Modules

Motivated by the rapidly rising deployment of bifacial monocrystalline-silicon photovoltaics (PV), we investigate the durability of various PV module packaging configurations with transparent coverings on both the front and rear sides of the module. We use a series of bifacial passivated emitter and rear cell (p-PERC) mini-modules with systematically varying outer cover materials (glass/glass, G/G, or glass/transparent backsheet, G/TB) and encapsulant chemistries (poly [ethylene-co-vinyl acetate], EVA; or polyolefin, POE). We study degradation modes over 1,000 hours of combined damp heat (DH) exposure and high system voltages that can cause potential-induced degradation (PID) under positive, zero, or negative 1,000 V cell-to-frame bias. We analyze the degradation modes using a combination of current-voltage measurements, impedance spectroscopy, external quantum efficiency, and spatially resolved luminescence and thermal imaging. Our results highlight various types of degradation including shunting, enhanced recombination, and series resistance increases, and we use spatially resolved characterization to separately identify the localized effects. We show that multiple PID and moisture-ingress degradation modes severely affect EVA-containing modules, with previously reported PID processes under negative-bias DH and a unique observation of rear-side surface recombination in G/EVA/G modules under positive-bias DH. We observe significantly less degradation in POE-containing modules, where the G/POE/G configuration exhibits minimal degradation under all stress conditions that we employ.

14 SOLAR ENERGY↗

CdTe‐Based Solar Cells with Variations in Mg Concentration in the MgZnO Emitter

The optimal fraction of Mg incorporation in sputter-deposited Mg X Zn 1−X O (MZO) emitters for thin-film CdTe-based solar cells is evaluated by varying it over a range of x from 0 to 0.35. This range allows a variation in the conduction band offset from −0.1 eV (cliff like) to +0.32 eV (spike like). Here, a maximum efficiency of 18.5% for cells with the bilayer CdSeTe/CdTe absorber occurs at x = 0.15, which corresponds to a spike-like band offset near 0.2 eV, as confirmed by X-ray photoelectron spectroscopy. In addition, good cell performance is seen over a fairly broad range of x extending from 0.1 to 0.25. The MZO optical bandgap increases with the Mg fraction, consistent with an increasing conduction band offset. Temperature-dependent current−voltage measurements and time-resolved photoluminescence show improvement in the emitter/absorber interface with the incorporation of Mg. Capacitance−voltage measurements show that the depletion region extends further into the absorber with more Mg, and X-ray diffraction confirms a change from a hexagonal-dominant crystal structure toward zinc blende at x = 0.35.

14 SOLAR ENERGY↗