Ball Aerospace SBMD Coating Test Results

The Sub-scale Beryllium Mirror Demonstrator that was successfully tested to demonstrate cryogenic figuring of a bare mirror has been coated with a protected gold reflective surface and retested at cryogenic temperatures. Results showing less than 9 nm rms surface distortion attributable to the added coating are presented.

Brown, Robert↗

Shutter Mechanism for Calibration of the Cryogenic Diffused Infrared Background Experiment (DIRBE) Instrument

This paper describes the design requirements, the design, the assembly and alignment, and the test program for a shutter mechanism which must operate at cryogenic temperature and draw less than 1.0 milliwatt. The design solution to meet these requirements is a device that positions a mirror with repeated accuracy, has no wearing surfaces and operates at 2.0 K. The unique feature of this device is the simplicity of the mechanism, thus obtaining high reliability.

Tyler, Allen↗

Cryogenetically Cooled Field Effect Transistors for Low-Noise Systems

Recent tends in the design, fabrication and use of High-Electron-Mobility-Transistors (HEMT) in low noise amplifiers are reviewed. Systems employing these devices have achieved the lowest system noise for wavelengths greater than three millimeters with relatively modest cryogenic cooling requirements in a variety of ground and space based applications. System requirements which arise in employing such devices in imaging applications are contrasted with other leading coherent detector candidates at microwave wavelengths. Fundamental and practical limitations which arise in the context of microwave application of field effect devices at cryogenic temperatures will be discussed from a component and systems point of view.

Wollack, Edward J.↗

Cryogenically Cooled Field Effect Transistors for Low-Noise Systems

Recent tends in the design, fabrication and use of High-Electron-Mobility-Transistors (HEMT) in low noise amplifiers are reviewed. Systems employing these devices have achieved the lowest system noise for wavelengths greater than three millimeters with relatively modest cryogenic cooling requirements in a variety of ground and space based applications. System requirements which arise in employing such devices in imaging applications are contrasted with other leading coherent detector candidates at microwave wavelengths. Fundamental and practical limitations which arise in the context of microwave application of field effect devices at cryogenic temperatures will be discussed from a component and systems point of view.

Wollack, Edward J.↗

Space Shuttle ET Friction Stir Weld Machines

NASA and Lockheed-Martin approached the FSW machine vendor community with a specification for longitudinal barrel production FSW weld machines and a shorter travel process development machine in June of 2000. This specification was based on three years of FSW process development on the Space Shuttle External Tank alloys, AL2 195-T8M4 and AL22 19-T87. The primary motivations for changing the ET longitudinal welds from the existing variable polarity Plasma Arc plasma weld process included: (1) Significantly reduced weld defect rates and related reduction in cycle time and uncertainty; (2) Many fewer process variables to control (5 vs. 17); (3) Fewer manufacturing steps; (4) Lower residual stresses and distortion; (5) Improved weld strengths, particularly at cryogenic temperatures; (6) Fewer hazards to production personnel. General Tool was the successful bidder. The equipment is at this writing installed and welding flight hardware. This paper is a means of sharing with the rest of the FSW community the unique features developed to assure NASA/L-M of successful production welds.

Thompson, Jack M.↗

Impedance-Based Structural Health Monitoring for Composite Laminates at Cryogenic Environments

One of the important ways of increasing the payload in a reusable launch vehicle (RLV) is to replace heavy metallic materials by lightweight composite laminates. Among various parts and systems of the RLV, this project focuses on tanks containing cryogenic fuel. Historically, aluminum alloys have been used as the materials to construct fuel tanks for launch vehicles. To replace aluminum alloys with composite laminates or honeycomb materials, engineers have to make sure that the composites are free of defects before, during, and after launch. In addition to robust design and manufacturing procedures, the performance of the composite structures needs to be monitored constantly.In recent years, the impedance-based health monitoring technique has shown its promise in many applications. This technique makes use of the special properties of smart piezoelectric materials to identify the change of material properties due to the nucleation and progression of damage. The piezoceramic patch serves as a sensor and an actuator simultaneously. The piezoelectric patch is bonded onto an existing structure or embedded into a new structure and electrically excited at high frequencies. The signature (impedance or admittance) is extracted as a function of the exciting frequency and is compared with the baseline signature of the healthy state. The damage is quantified using root mean square deviation (RMSD) in the impedance signatures with respect to the baseline signature. A major advantage of this technique is that the procedure is nondestructive in nature and does not perturb the properties and performance of the materials and structures. This project aims at applying the impedance-based nondestructive testing technique to the damage identification of composite laminates at cryogenic temperature.

Tseng, Kevin↗

Microcrack Quantification in Composite Materials by a Neural Network Analysis of Ultrasound Spectral Data

Intra-ply microcracking in unlined composite pressure vessels can be very troublesome to detect and when linked through the thickness can provide leak paths that may hinder mission success. The leaks may lead to loss of pressure/propellant, increased risk of explosion and possible cryo-pumping into air pockets within the laminate. Ultrasonic techniques have been shown capable of detecting the presence of microcracking and in this work they are used to quantify the level of microcracking. Resonance ultrasound methods are utilized with artificial neural networks to build a microcrack prediction/measurement tool. Two networks are presented, one unsupervised to provide a qualitative measure of microcracking and one supervised which provides a quantitative assessment of the level of microcracking. The resonant ultrasound spectroscopic method is made sensitive to microcracking by tuning the input spectrum to the higher frequency (shorter wavelength) components allowing more significant interaction with the defects. This interaction causes the spectral characteristics to shift toward lower amplitudes at the higher frequencies. As the density of the defects increases more interactions occur and more drastic amplitude changes are observed. Preliminary experiments to quantify the level of microcracking induced in graphite/epoxy composite samples through a combination of tensile loading and cryogenic temperatures are presented. Both unsupervised (Kohonen) and supervised (radial basis function) artificial neural networks are presented to determine the measurable effect on the resonance spectrum of the ultrasonic data taken from the samples.

Walker, James L.↗

Use of Plastic Capillaries for Macromolecular Crystallization

Methods of crystallization of biomolecules in plastic capillaries (Nalgene 870 PFA tubing) are presented. These crystallization methods used batch, free-interface liquid- liquid diffusion alone, or a combination with vapor diffusion. Results demonstrated growth of crystals of test proteins such as thaumatin and glucose isomerase, as well as protein studied in our laboratory such dihydrolipoamide dehydrogenase. Once the solutions were loaded in capillaries, they were stored in the tubes in frozen state at cryogenic temperatures until the desired time of activation of crystallization experiments.

Potter, Rachel R.↗

Cryogenic Transfer Line Chilldown

The transient behavior of a small scale cryogenic transfer line was investigated during chilldown to cryogenic temperatures. The vacuum-jacketed apparatus consisted of a vertical tube followed by a near horizontal tube. The apparatus was equipped with view ports in the near horizontal section to allow visual observation of the flow patterns. Wall temperatures were measured at various locations along the length of the transfer line. Each test was conducted at a constant liquid volumetric flowrate at the transfer line inlet until saturation temperatures were obtained throughout the system.

VanDresar, Neil T.↗

Optical Properties of Zitex in the Infrared Submillimeter

The results of measurements of the refractive index and power attenuation coefficient of Zitex at 290K, 77K, and 4K in the spectral region from 1 to 1000 microns are presented. Zitex is a porous Teflon sheet with a filling factor of approx. 50%, and is manufactured in several varieties as a filter paper. Zitex is found to be an effective IR block, with thin (200 microns) sheets transmitting less than 1% in the 1 - 50 microns range while attenuating less than or approx. 10% at wavelengths longer than 200 microns. Some variation in the cutoff wavelength is seen, tending to be a shorter wavelength cutoff for a smaller pore size. Additionally, the thermal conductivity of Zitex at cryogenic temperatures has been measured, and is found to be roughly one-half that of bulk Teflon. Finally, its dielectric constant has been measured in the submillimeter as n = 1.20, resulting in extremely low dielectric reflection losses. As a result, Zitex is particularly useful as an IR blocking filter in low-noise heterodyne receivers; in the millimeter-wave range (lambda greater than approx. 850 microns or nu less than or = 350 GHz) the attenuation of alpha less than or = 0.01/cm for a 3.5 mm thickness filter of Zitex G125 would raise receiver noise temperatures by less than 1K.

Benford, Dominic J.↗

NASA Space Cryocooler Programs: A 2003 Overview

Mechanical cryocoolers represent a significant enabling technology for NASA's Earth and Space Science missions. An overview is presented of ongoing cryocooler activities within NASA in support of current flight projects, near-term flight instruments, and long-term technology development. NASA programs in Earth and space science observe a wide range of phenomena, from crop dynamics to stellar birth. Many of the instruments require cryogenic refrigeration to improve dynamic range, extend wavelength coverage, and enable the use of advanced detectors. Although, the largest utilization of coolers over the last decade has been for instruments operating at medium to high cryogenic temperatures (55 to 150 K), reflecting the relative maturity of the technology at these temperatures, important new developments are now focusing at the lower temperature range from 4 to 20 K in support of studies of the origin of the universe and the search for planets around distant stars. NASA's development of a 20K cryocooler for the European Planck spacecraft and its new Advanced Cryocooler Technology Development Program (ACTDP) for 6-18 K coolers are examples of the thrust to provide low temperature cooling for this class of missions.

Ross, R. G., Jr.↗

Programmable 2-D Addressable Cryogenic Aperture Masks

We are developing a two-dimensional array of square microshutters (programmable aperture mask) for a multi-object spectrometer for the James Webb Space Telescope (JWST). This device will provide random access selection of the areas in the field to be studied. The device is in essence a close packed array of square slits, each of which can be opened independently to select areas of the sky for detailed study.The device is produced using a 100-micron thick silicon wafer as a substrate with 0.5-micron thick silicon nitride shutters on top of it. Silicon nitride has been selected as the blade and flexure material because its stiffness allows thinner and lighter structures than single crystal Si, the chief alternative, and because of its ease of manufacture. The 100 micron silicon wafer is backetched in a high aspect ratio Deep Reactive Ion Etching (Deep RIE) to leave only a support grid for the shutters and the address electronics. The shutter actuation is done magnetically whereas addressing is electrostatic. 128x128 format microshutter arrays have been produced. Their operation has been demostarted on 32x32 subarrays. Good reliability of the fabrication process and good quality of the microshutters has been achieved. The mechanical behavior and optical performance of the fabricated arrays at cryogenic temperature are being studied.

Kutyrev, A. S.↗

JWST ISIM Primary Structure and Kinematic Mount Configuration

In this presentation we will review the evolution of the ISIM primary structure tube topology and kinematic mount configuration to the current baseline concept. We will also show optimization procedures used and challenges resulting from complex joints under launch loads. Two additional key ISIM structure challenges of meeting thermal distortion and stability requirements and metal-composite bonded joint survivability at cryogenic temperatures are covered in other presentations.

Bartoszyk, Andrew↗

Fabrication of MEMS-Based Microshutter Arrays for Optical Transmission Selection

A MEMS-based programmable aperture mask is under development at the NASA Goddard Space Flight Center. Termed the Microshutter (u-shutter) Array, the device will be used to control the transmission of light, with both high efficiency and contrast, to a multi-object spectrometer on the James Webb Space Telescope. Fabrication of the p-shutter array employs several novel designs and processing techniques. The current generation of micro-shutters consists of 128x64 pixel arrays with unit cell dimensions of 100x200 microns. Shutters are patterned in silicon nitride and sit on a 100 micron silicon frame that is DRIE etched below each shutter. The front and back sides of the device are shown. A magnetic cobalt-iron alloy patterned on top of the shutter allows it to be actuated 90 degrees out-of-plane, into the frame, by an external magnetic field. An electrode on the shutter and a vertical electrode on the sidewall of the frame, approximately 90pm deep, allow them to be electrostatically latched in their rotated position. The vertical electrode is deposited and patterned on the backside of the frame in a single step using a directionally controlled evaporation. Individual addressing of shutters for electrostatic latching is accomplished via a crosspoint addressing scheme, with no on-chip active components. A portion of an array with shutters in the open, latched, and closed positions is shown. Light loss at shutter edges is minimized by an overhanging aluminum light-shield that is anchored to the frame. A photoresist sacrificial layer is used to raise the light-shield up and over the 2 micron gap that surrounds each pixel. After completion, arrays are subjected to life cycle, environmental and optical testing. Fabricated devices have survived 10(exp 6) actuation cycles at both room and cryogenic temperatures and a 14g rms launch-simulation test. Optical testing has shown contrast measurements between open and closed shutters up to 10000:1.

Lynch, Bernard A.↗

Measurement of heat conduction through stacked screens

This paper describes the experimental apparatus for the measurement of heat conduction through stacked screens as well as some experimental results taken with the apparatus. Screens are stacked in a fiberglass-epoxy cylinder, which is 24.4 mm in diameter and 55 mm in length. The cold end of the stacked screens is cooled by a Gifford-McMahon (GM) cryocooler at cryogenic temperature, and the hot end is maintained at room temperature. Heat conduction through the screens is determined from the temperature gradient in a calibrated heat flow sensor mounted between the cold end of the stacked screens and the GM cryocooler. The samples used for these experiments consisted of 400-mesh stainless steel screens, 400-mesh phosphor bronze screens, and two different porosities of 325-mesh stainless steel screens. The wire diameter of the 400-mesh stainless steel and phosphor bronze screens was 25.4 micrometers and the 325-mesh stainless steel screen wire diameters were 22.9 micrometers and 27.9 micrometers. Standard porosity values were used for the experimental data with additional porosity values used on selected experiments. The experimental results showed that the helium gas between each screen enhanced the heat conduction through the stacked screens by several orders of magnitude compared to that in vacuum. The conduction degradation factor is the ratio of actual heat conduction to the heat conduction where the regenerator material is assumed to be a solid rod of the same cross sectional area as the metal fraction of the screen. This factor was about 0.1 for the stainless steel and 0.022 for the phosphor bronze, and almost constant for the temperature range of 40 to 80 K at the cold end.

NASA Discipline Environmental Health↗

Poco Graphite Inc. SuperSiC 0.25m Mirror Cryogenic Test Result

SuperSiC, a low areal density material, developed by POCO Graphite, have been used as mirror substrate for high energy lasers, laser radar systems, surveillance, telescopes, scan mirrors and satellites. SuperSiC has excellent thermal properties and cryogenic stability. It exhibits exceptional polishability for reflective optics with high strength, stiffness, and excellent thermal conductivity. A lightweighted 0.2-diameter polished SuperSic mirror was tested at cryogenic temperature at NASMSFC. Optical test results showed 6nm cry0 deformation from ambient to 30 degrees Kelvin and little to no change in its surface figure due to cry0 cycling.

Eng, Ron↗

The Role of Integrated Modeling in the Design and Verification of the James Webb Space Telescope

The James Web Space Telescope (JWST) is a large, infrared-optimized space telescope scheduled for launch in 2011. System-level verification of critical optical performance requirements will rely on integrated modeling to a considerable degree. In turn, requirements for accuracy of the models are significant. The size of the lightweight observatory structure, coupled with the need to test at cryogenic temperatures, effectively precludes validation of the models and verification of optical performance with a single test in 1-g. Rather, a complex series of steps are planned by which the components of the end-to-end models are validated at various levels of subassembly, and the ultimate verification of optical performance is by analysis using the assembled models. This paper describes the critical optical performance requirements driving the integrated modeling activity, shows how the error budget is used to allocate and track contributions to total performance, and presents examples of integrated modeling methods and results that support the preliminary observatory design. Finally, the concepts for model validation and the role of integrated modeling in the ultimate verification of observatory are described.

Mosier, Gary E.↗

Structural Sizing of a Horizontal Take-Off Launch Vehicle with an Air Collection and Enrichment System

In support of NASA's Next Generation Launch Technology (NGLT) program, the Andrews Gryphon booster was studied. The Andrews Gryphon concept is a horizontal lift-off, two-stage-to-orbit, reusable launch vehicle that uses an air collection and enrichment system (ACES). The purpose of the ACES is to collect atmospheric oxygen during a subsonic flight loiter phase and cool it to cryogenic temperature, ultimately resulting in a reduced initial take-off weight To study the performance and size of an air-collection based booster, an initial airplane like shape was established as a baseline and modeled in a vehicle sizing code. The code, SIZER, contains a general series of volume, surface area, and fuel fraction relationships that tie engine and ACES performance with propellant requirements and volumetric constraints in order to establish vehicle closure for the given mission. A key element of system level weight optimization is the use of the SIZER program that provides rapid convergence and a great deal of flexibility for different tank architectures and material suites in order to study their impact on gross lift-off weight. This paper discusses important elements of the sizing code architecture followed by highlights of the baseline booster study.

McCurdy, David R.↗