Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Techno-Economic Analysis of Geologically Connected Seawater Air Conditioning (GeoSWAC) Concept for District Cooling at the University of Puerto Rico at Rio Piedras: Preprint

At the University of Puerto Rico at Rio Piedras, a central chilled water plant supplies cooling to several campus buildings, contributing significantly to electricity demand during daytime peak hours, particularly in the summer months. These operational challenges are exacerbated by Puerto Rico's tropical rainforest climate and a power grid vulnerable to frequent disruptions caused by hurricanes and tropical storms. This study presents a techno-economic analysis of the existing chilled water plant serving four representative campus buildings and introduces a conceptual alternative: the Geologically connected Seawater Air Conditioning (GeoSWAC) system. GeoSWAC leverages stable low temperatures of deep ocean water (~1 km depth), hydraulically connected to an inland well, to deliver cooling without the use of vapor-compression refrigeration. Using modeled annual cooling loads and chiller performance data, capital costs, energy consumption, and levelized cost of cooling (LCOC) were evaluated for both systems. While GeoSWAC showed higher capital costs than the chiller-based scenario, operational costs were significantly lower at $26k-$53k annually, resulting in a lower LCOC between $2.3/MWh and $8.2/MWh compared to $30.2/MWh-$33.6/MWh for the chiller scenario. These results suggest that the GeoSWAC system offers a promising, low-energy, and climate-resilient alternative for large-scale cooling in tropical coastal environments, with significant potential to reduce peak electricity demand and improve long-term system reliability.

15 GEOTHERMAL ENERGY↗

PERFORMANCE ANALYSIS OF MECHANICAL DRAFT COOLING TOWER

Industrial processes use mechanical draft cooling towers (MDCT's) to dissipate waste heat by transferring heat from water to air via evaporative cooling, which causes air humidification. The Savannah River Site (SRS) has cross-flow and counter-current MDCT's consisting of four independent compartments called cells. Each cell has its own fan to help maximize heat transfer between ambient air and circulated water. The primary objective of the work is to simulate the cooling tower performance for the counter-current cooling tower and to conduct a parametric study under different fan speeds and ambient air conditions. The Savannah River National Laboratory (SRNL) developed a computational fluid dynamics (CFD) model and performed the benchmarking analysis against the integral measurement results to accomplish the objective. The model uses three-dimensional steady-state momentum, continuity equations, air-vapor species balance equation, and two-equation turbulence as the basic governing equations. It was assumed that vapor phase is always transported by the continuous air phase with no slip velocity. In this case, water droplet component was considered as discrete phase for the interfacial heat and mass transfer via Lagrangian approach. Thus, the air-vapor mixture model with discrete water droplet phase is used for the analysis. A series of parametric calculations was performed to investigate the impact of wind speeds and ambient conditions on the thermal performance of the cooling tower when fans were operating and when they were turned off. The model was also benchmarked against the literature data and the SRS integral test results for key parameters such as air temperature and humidity at the tower exit and water temperature for given ambient conditions. Detailed results will be published here.

42 ENGINEERING↗

Muon Capture, Phase Rotation, and Cooling in Pressurized RF Cavities

Gas-filled rf cavities can provide high-gradient accelerating fields for muons, and can be used for simultaneous acceleration and cooling of muons. In this paper we explore using these cavities in the front-end of the capture and cooling systems for neutrino factories and muon colliders. We consider using gas-filled rf cavities for the initial front end cooling systems. We also consider using them for simultaneous phase-energy rotation and cooling in a front-end system. We also consider using lower-density rf cavities, where the gas density is primarily for rf breakdown suppression, with less cooling effect. Pressurized rf cavities enable higher gradient rf within magnetic fields than is possible with evacuated cavities, enabling more options in the front-end. The status of designs of the capture, phase rotation, and precooling systems of muon beams in pressurized cavities is described.

43 PARTICLE ACCELERATORS↗

A contribution to film coefficient estimation in piston cooling galleries

The need to reduce fuel consumption and exhaust emissions in internal combustion engines has been drastically increased during last years. One of the most important processes affecting these parameters is heat transfer from the in-cylinder gas to the surrounding walls, as this mechanism has a direct influence on the combustion process. Regarding the different walls (liner, cylinder head and piston surfaces), heat flow to the piston is especially important, as it is essential to avoid excessively high temperatures that could result in material damage and/or oil cracking. With this purpose different cooling strategies are used, among which the improvement of the piston cooling system by using oil galleries is preferred. In this work, the heat flow through the oil gallery in a Diesel piston was investigated on a dedicated test bench. This bench consists of a controlled heat source and a piston oil cooling system in which different test conditions were evaluated in order to obtain a correlation for the film coefficient associated with piston oil cooling. These experimental results were then incorporated into a lumped model for engine heat transfer. Finally, in order to evaluate the accuracy of this model and the effects of the correlation for oil gallery coefficient on engine heat flows, results obtained on a conventional engine test bench equipped with a Diesel engine, in which two piston temperatures had been measured, were used. The results show an improvement in piston temperature predictions when compared with those obtained using a previously reported expression for the calculation of the oil film coefficient. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Experimental study on corrugated cross-flow air-cooled plate heat exchangers

Experimental study on cross-flow air-cooled plate heat exchangers (PHEs) was performed. The two prototype PHEs were manufactured in a stack of single-wave plates and double-wave plates in parallel. Cooling air flows through the PHEs in a crosswise direction against internal cooling water. The heat exchanger aims to substitute open-loop cooling towers with closed-loop water circulation, which guarantees cleanliness and compactness. In this study, the prototype PHEs were tested in a laboratory scale experiments. From the tests, double-wave PHE shows approximately 50% enhanced heat transfer performance compared to single-wave PHE. However, double-wave PHE costs 30% additional pressure drop. For commercialization, a wide channel design for air flow would be essential for reliable performance. (author)

42 ENGINEERING↗

Comparative study with two reduced test facilities for air-cooled RCCS scaling law

Korea Atomic Energy Research Institute (KAERI) and Argonne National Laboratory (ANL) conducted steady-state tests at constant heat flux conditions to investigate the scale effect on heat removal behavior of the air-cooled Reactor Cavity Cooling System (RCCS). Two differently scaled-down test facilities were used in this study, KAERI’s ¼ scale with 4.0-m cavity height, and ANL’s ½ scale with 6.8-m cavity height. Two scaling laws were proposed to simulate the radiation across the cavity and the buoyancy-driven duct flow in the riser, respectively. The test matrix for KAERI and ANL test facilities focused on the scaling effect of the heated riser length with constant heat flux at the PMR200 RCCS design. The test results showed that mixed convection in the riser duct is an important factor for accurately extrapolating the thermo-fluid behavior in the prototype from the test results in the scale-down facilities. The system analysis code, GAMMA+, with improved heat transfer models predicted fairly well the air-cooled RCCS test data from two facilities. GAMMA+ analysis results showed that the predicted radiation fractions on the heated plate in the scale-down test conditions were larger than those on the reactor vessel in the prototype. The scaling law for air-cooled RCCS was improved by considering the mixed convection in the riser duct and the same radiation fraction on the heated plate. The mixed convection effect was calculated by the height ratio. The same radiation fraction provided a conservative extrapolation from the scale-down test results.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Air Cooling for High Temperature Power Electronics (Presentation)

Current emphasis on developing high-temperature power electronics, including wide-bandgap materials such as silicon carbide and gallium nitride, increases the opportunity for a completely air-cooled inverter at higher powers. This removes the liquid cooling system for the inverter, saving weight and volume on the liquid-to-air heat exchanger, coolant lines, pumps, and coolant, replacing them with just a fan and air supply ducting. We investigate the potential for an air-cooled heat exchanger from a component and systems-level approach to meet specific power and power density targets. A proposed baseline air-cooled heat exchanger design that does not meet those targets was optimized using a parametric computational fluid dynamics analysis, examining the effects of heat exchanger geometry and device location, fixing the device heat dissipation and maximum junction temperature. The CFD results were extrapolated to a full inverter, including casing, capacitor, bus bar, gate driver, and control board component weights and volumes. Surrogate ducting was tested to understand the pressure drop and subsequent system parasitic load. Geometries that met targets with acceptable loads on the system were down-selected for experimentation. Nine baseline configuration modules dissipated the target heat dissipation, but fell below specific power and power density targets. Six optimized configuration modules dissipated the target heat load, exceeding the specific power and power density targets. By maintaining the same 175 degrees C maximum junction temperature, an optimized heat exchanger design and higher device heat fluxes allowed a reduction in the number of modules required, increasing specific power and power density while still maintaining the inverter power.

30 DIRECT ENERGY CONVERSION↗

The state of the art in hadron beam cooling

Cooling of hadron beams (including heavy-ions) is a powerful technique by which accelerator facilities around the world achieve the necessary beam brightness for their physics research. In this paper, we will give an overview of the latest developments in hadron beam cooling, for which high energy electron cooling at Fermilab's Recycler ring and bunched beam stochastic cooling at Brookhaven National Laboratory's RHIC facility represent two recent major accomplishments. Novel ideas in the field will also be introduced.

43 PARTICLE ACCELERATORS↗

Probabilistic constrained Bayesian inversion for transpiration cooling

Abstract To enable safe operations in applications such as rocket combustion chambers, the materials require cooling to avoid material damage. Here, transpiration cooling is a promising cooling technique. Numerous studies investigate possibilities to simulate and evaluate the complex cooling mechanism. One naturally arising question is the amount of coolant required to ensure a safe operation. To study this, we introduce an approach that determines the posterior probability distribution of the Reynolds number using an inverse problem and constraining the maximum temperature of the system under parameter uncertainties. Mathematically, this chance inequality constraint is dealt with by a generalized polynomial chaos expansion of the system. The posterior distribution will be evaluated by different Markov chain Monte Carlo based methods. A novel method for the constrained case is proposed and tested among others on two‐dimensional transpiration cooling models.

97 MATHEMATICS AND COMPUTING↗

Sustained Growth of the Ex Vivo Ablation Zones' Critical Short Axis Using Gas-cooled Radiofrequency Applicators

Purpose: To evaluate the ablation zones created with a gas-cooled bipolar radiofrequency applicator performed on ex vivo bovine liver tissue. Materials and Methods: A total of 320 ablations with an internally gas-cooled bipolar radiofrequency applicator were performed on fresh ex vivo bovine liver tissue, varying the ablation time (5, 10, 15, and 20 min), power (20, 30, 40, and 50 W), and gas pressure of the CO{sub 2} used for cooling (585, 600, 615, 630, 645 psi), leading to a total of 80 different parameter combinations. Size and shape of the white coagulation zone were assessed. Results: The largest complete ablation zone was achieved after 20 min of implementing 50 W and 645 psi, resulting in a short axis of mean 46 {+-} 1 mm and a long axis of 56 {+-} 2 mm (mean {+-} standard deviation). Short-axis diameters increased between 5 and 20 min of ablation time at 585 psi (increase of the short axis was 45% at 30 W, 29% at 40 W, and 39% at 50 W). This increase was larger at 645 psi (113% at 30 W, 67% at 40 W, and 70% at 50 W). Macroscopic assessment and NADH (nicotinamide adenine dinucleotide) staining revealed incompletely ablated tissue along the needle track in 18 parameter combinations including low-power settings (20 and 30 W) and different cooling levels and ablation times. Conclusion: Gas-cooled radiofrequency applicators increase the short-axis diameter of coagulation in an ex vivo setting if appropriate parameters are selected.

60 APPLIED LIFE SCIENCES↗

Catastrophic Cooling Instability in Optically Thin Plasmas

The solar corona is the prototypical example of a low-density environment heated to high temperatures by external sources. The plasma cools radiatively, and because it is optically thin to this radiation, it becomes possible to model the density, velocity, and temperature structure of the system by modifying the MHD equations to include an energy source term that approximates the local heating and cooling rates. The solutions can be highly inhomogeneous and even multiphase because the well-known linear instability associated with this source term, thermal instability, leads to a catastrophic heating and cooling of the plasma in the nonlinear regime. Here we show that there is a separate, much simpler linear instability accompanying this source term that can rival thermal instability in dynamical importance. The stability criterion is the isochoric one identified by Parker (1953), and we demonstrate that cooling functions derived from collisional ionization equilibrium are highly prone to violating this criterion. If catastrophic cooling instability can act locally in global simulations, then it is an alternative mechanism for forming condensations, and due to its nonequilibrium character, it may be relevant to explaining a host of phenomena associated with the production of cooler gas in hot, low density plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Different Cooling Rates on the Corrosion Behavior of High-Carbon Pearlitic Steel

The present work discusses the effect of pearlitic morphology on the corrosion behavior of high-carbon fully pearlitic steel in 3.5% NaCl solution. Four different types of pearlitic steels (furnace-cooled, as-received, air-cooled and forced-air-cooled) consisting of coarse, medium, fine and very fine microstructures, respectively, were tested. Electrochemical behavior of these steels was studied with the help of dynamic and linear polarization and AC impedance spectroscopic tests. The corrosion resistance improved with fineness of the microstructure in general. However, with further reduction in interlamellar spacing beyond a limit, the corrosion resistance reduced slightly. Formation of homogeneous distribution of microgalvanic cells between cementite and ferrite lamellae of fine pearlitic steel improved the corrosion resistance. However, entanglement of the lamellae of pearlite in very fine pearlitic structure as well as breaking of cementite lamellae due to finer pearlitic colonies was attributed to the higher corrosion of the forced-air-cooled steel as compared to the air-cooled steel.

36 MATERIALS SCIENCE↗

Effects of Solidification Cooling Rates on Microstructures and Physical Properties of Fe-6.5%Si Alloys

Compared to the widely used Fe-3.2wt%Si steel, Fe-6.5wt%Si has superior electric and magnetic properties, including higher electrical resistivity, lower iron loss, higher permeability, and near zero magnetostriction. However, Fe-6.5wt%Si sheet is difficult to produce using traditional manufacturing processes as the high silicon content favors the formation of ordered phases that embrittle the material. Fortunately, these ordered phases can be suppressed if the alloy is cooled fast enough from a high temperature kinetically trapping the disordered solid solution or amorphous state. Planar flow casting is known for its rapid solidification rate. In order to consider it as a viable method to manufacture ductile Fe-6.5wt%Si sheets, the effect of cooling rate on physical properties of Fe-6.5wt%Si alloy are systematically investigated. In this work, various cooling rates are achieved by changing melt-spin wheel speeds, which significantly affect the solidification temperature profile and have profound effects on ordering, microstructures, textures, hardness, and magnetic properties. High cooling rates result in refined grains, reduced ordering, enhanced <100> out of the plane texture, decreased hardness, and increased coercivity. This study demonstrates a critical cooling rate at ~1.7 × 10 5 K/s, corresponding to a tangential wheel speed of 5-7 m/s, below which the hardness significantly increases in agreement with the sudden increase of the ordered phases that causes the material embrittlement.

36 MATERIALS SCIENCE↗

Experimental validation of an organic rankine-vapor compression cooling cycle using low GWP refrigerant R1234ze(E)

There is a significant global opportunity to capture and utilize low grade waste heat to reduce fossil fuel consumption, greenhouse gas emissions, and improve energy efficiency across a wide range of industries. In this work, an advanced type of thermally activated cooling system, an organic Rankine-vapor compression cycle (ORVC) with novel heat integration strategies, was designed and tested at a relevant scale for industrial waste heat recovery (300 kW th cooling capacity). The ORVC linked an organic Rankine power cycle and a vapor compression cooling cycle using a turbine and compressor that shared a single shaft. The ORVC test facility absorbed waste heat from a liquid stream at 91 °C to simulate engine coolant in diesel generator sets, rejected heat to a glycol stream at 30 °C, and generated chilled water at 7 °C. A cooling capacity of 264 kW ± 3.5 kW was experimentally validated with a COP of 0.56 ± 0.01 during steady-state operation at the design temperatures. The thermal efficiency, accounting for pump work, of the Rankine cycle was 7.7% ± 0.22% and the COP of the vapor compression cycle was 5.25 ± 0.09. The centrifugal turbo-compressor operated at 31.5 kRPM ± 0.3 kRPM, with a turbine and compressor isentropic efficiencies of 76.7% ± 0.90% and 84.8% ± 0.54%, respectively, with near-perfect power transmission between these components. The pressure drop in the piping and heat exchangers were significantly larger than expected which had a detrimental impact on the performance of the ORVC. In addition, the condenser on the cooling cycle could not deliver the subcooling as specified from the design point modeling. Furthermore, the results from the sensitivity analysis showed that the higher condenser glycol outlet temperature had the largest impact on performance, which is consistent with other analytical models in the literature. When the ORVC simulations were updated with experimental values for isentropic efficiencies of the turbomachinery, the thermal COP was 0.66 which represents an estimate of the predicted performance if test facility limitations are overcome.

30 DIRECT ENERGY CONVERSION↗

Spatial distribution of internal heat gains: A probabilistic representation and evaluation of its influence on cooling equipment sizing in large office buildings

Internal heat gains from occupants, lighting, and plug loads are significant components of the space cooling load in an office building. Internal heat gains vary with time and space. The spatial diversity is significant, even for spaces with the same function in the same building. The stochastic nature of internal heat gains makes determining the peak cooling load to size air-conditioning systems a challenge. The traditional conservative practice of considering the largest internal heat gain among spaces and applying safety factors overestimates the space cooling load, which leads to oversized air-conditioning equipment and chiller plants. In this study, a field investigation of several large office buildings in China led to the development of a new probabilistic approach that represents the spatial diversity of the design internal heat gain of each tenant as a probability distribution function. In a large office building, a central chiller plant serves all air handling units (AHUs), with each AHU serving one or more floors of the building. Therefore, the spatial diversity should be considered differently when the peak cooling loads to size the AHUs and chillers are calculated. Finally, the proposed approach considers two different levels of internal heat gains to calculate the peak cooling loads and size the AHUs and chillers in order to avoid oversizing, improve the overall operating efficiency, and thus reduce energy use.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Utilization of municipal wastewater for cooling in thermoelectric power plants: Evaluation of the combined cost of makeup water treatment and increased condenser fouling

A methodology is presented to calculate the total combined cost (TCC) of water sourcing, water treatment and condenser fouling in the recirculating cooling systems of thermoelectric power plants. The methodology is employed to evaluate the economic viability of using treated municipal wastewater (MWW) to replace the use of freshwater as makeup water to power plant cooling systems. Cost analyses are presented for a reference power plant and five different tertiary treatment scenarios to reduce the scaling tendencies of MWW. Results indicate that a 550 MW sub-critical coal fired power plant with a makeup water requirement of 29.3 ML/day has a TCC of $3.0 - 3.2 million/yr associated with the use of treated MWW for cooling. (All costs USD 2009). This translates to a freshwater conservation cost of $0.29/kL, which is considerably lower than that of dry air cooling technology, $1.5/kL, as well as the 2020 conservation cost target set by the U.S. Department of Energy, $0.74/kL. Results also show that if the available price of freshwater exceeds that of secondary-treated MWW by more than $0.13-0.14/kL, it can be economically advantageous to purchase secondary MWW and treat it for utilization in the recirculating cooling system of a thermoelectric power plant.

20 FOSSIL-FUELED POWER PLANTS↗

Design, fabrication, and testing of a water-cooled tungsten-foam high-heat flux plasma-facing module

Here, we present a comprehensive study detailing the design, fabrication and testing a new modular “finger” component, featuring a hexagonal tungsten foam armor tile bonded to the top surface of the water-cooled finger unit. The mechanical, thermal, and particle transport properties of the tungsten foam armor were determined for a wide range of porosity and cell size, and then combined in an equivalent solid material with “effective” properties suitable for large-scale simulations. A series of 3-D multiphysics simulations for coupled thermal and mechanical behavior of the “finger” module are used to optimize the design before fabrication. The simulation results show that, for the expected experimental conditions, a safe range of heat flux and foam porosity is possible for both water-cooling and helium-cooling. Based on these multiphysics simulations, an optimum finger cooling module has been fabricated at Ultramet, Inc. A series of experiments were designed to study the thermomechanical performance of the “finger” unit under steady-state and transient thermal loading at surface heat flux up to 16 MW/m 2 in the High Energy Flux Test facility (HEFTY) at UCLA. Testing conditions included low-power, steady-state plasma exposure at 6 MW/m 2 , followed by severe high heat flux cycles at 16 MW/m 2 . Results of these tests are explained through comparisons with multiphysics simulations. To eliminate the effects of thermomechanical damage carried out on a module on its thermo-mechanical response on a subsequent test, three different yet identically designed and fabricated finger modules were tested. The results show that the current design is capable of cooling the walls of fusion devices at surface heat flux up to 6 MW/m 2 without failure, and that the failure heat flux limit is below 16 MW/m 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Formation, cooling history and age of impact events on the IIE iron parent body: Evidence from the Miles meteorite

Most iron meteorites formed in planetary cores during differentiation, but the IIE iron meteorites have chemical and physical features that are inconsistent with this origin. By combining mineral chemistry, mineral modes and three-dimensional petrography, we reconstruct the bulk chemistry of the felsic silicate-bearing Miles IIE iron meteorite and demonstrate that the silicate inclusion compositions are similar to partial melts produced experimentally from an H chondrite composition. We use the reconstructed bulk composition, mineralogy and thermodynamic modelling to show that melting above ~ 1200°C under reducing conditions formed metal (Fe-Ni alloy) and felsic silicate partial melts. Upon cooling, the melts crystallized Mg-rich pyroxenes, Na- and K-rich feldspars, and tridymite. Importantly, this mechanism enriches cosmochemically volatile elements (i.e., those with a 50% condensation temperature of ~430–830°C, like Na and K) to the level found in the felsic silicate inclusions. The presence of crystallographically disordered srilankite (only stable above 1160°C) and an absence of Widmanstätten texture require both high peak temperatures and rapid cooling, which cannot be explained by core formation. Instead, they point to small melt volumes, a transient heat pulse, and small thermal mass, and imply efficient physical segregation of silicate and metallic melts through buoyancy separation followed by rapid cooling that arrested the separation of metal and silicate liquid phases. In situ 207 Pb/ 206 Pb age of 4542.3 ± 4.0 Ma in Zr-oxide and phosphate minerals dates the melting event that formed the silicate inclusions. This age aligns with the earliest ages found in other IIE iron meteorite silicates and requires a heating event ~25 million years after the solar system formed. We found 39 Ar/ 40 Ar ages of 3495 ± 52 Ma (low-T) and 4303 ± 7 Ma (high-T) in a K-feldspar grain, with the 3495 Ma age aligning with later thermal events recorded in other IIE iron meteorites. Dating reveals the complex petrogenetic and thermal history of Miles and the IIE iron meteorites. This is the first IIE iron meteorite found to record evidence of heating at 4.5 and 3.5 Ga likely from impact events. We propose that high-velocity impact(s) into an iron-rich, porous chondritic parent body at ~4.54 Ga produced immiscible metal and silicate melts that cooled rapidly and trapped low density silicate inclusions within high density metal. Other IIE irons that formed at lower peak temperatures (900–1000°C) contain chondritic silicate inclusions and relict chondrules, supporting this conceptual model. In conclusion, this petrogenesis is consistent with thermodynamic modelling, experimental data and the wide range of peak temperatures and cooling rates observed in the IIE iron meteorites.

58 GEOSCIENCES↗