Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Experimental comparison of heterodyne and direct detection for pulsed differential absorption CO2 lidar

A pulsed dual-wavelength dual-CO2-laser differential-absorption lidar (DIAL) system has been developed which permits simultaneous heterodyne and direct detection of the same lidar returns. This system has been used to make an experimental comparison of the SNRs and statistical and temporal characteristics of the DIAL returns from several topographic targets. These results were found to be in general agreement with theory and were used to quantify the relative merits of the two detection techniques. The measured parameter values were applied to an analytical treatment to predict system trade-offs for the remote sensing of atmospheric species, with application to both path-averaged and range-resolved measurements.

Killinger, D. K.↗

Flight effects on fan noise with static and wind tunnel comparisons

A flight test program utilizing a JT15D-1 turbofan engine has been conducted with the objectives of studying flight effects on fan noise and evaluating the simulation effectiveness of both a wind tunnel and a static test configuration that incorporated an inlet control device (ICD). In conjunction with synchronized laser-radar tracking and meteorological profile information, data obtained from a linear array of ground microphones was narrowband-analyzed and ensemble-averaged to yield highly accurate far-field flight acoustic results. Utilizing appropriate corrections, flight, wind tunnel, and static acoustic data were normalized to a static-equivalent, 100-foot radius, lossless reference condition. Data comparisons showed that both the static test with ICD and wind tunnel were generally very effective in simulating flight blade-passage-frequency (BPF) noise levels. However, differences were observed in broadband noise levels and in the details of the multiple-pure-tone harmonics.

Preisser, J. S.↗

Comparison of measured and predicted flight effects on high-bypass coaxial jet exhaust noise

A recently developed semi-empirical model for predicting the noise generated by conventional-velocity-profile coaxial jets is compared with full-scale flight data and model-scale simulated flight data for high-bypass nozzles. The prediction model has been shown to agree with small-scale static data for primary jet velocities from 215 to 795 m/s for a wide range of area, temperature and velocity ratios between streams. However, there were insufficient model nozzle, simulated flight data available at that time to permit validation of the flight effects prediction. The comparisons presented in this paper demonstrate that the prediction method is also valid in flight.

Stone, J. R.↗

Comparison of advanced thermal and electrical storage for parabolic dish solar thermal power systems

Parabolic dish solar concentrator cluster concepts are explored, with attention given to thermal storage systems coupled to Stirling and Brayton cycle power conversion devices. Sensible heat storage involving molten salt (NaOH), liquid sodium, and solid cordierite bricks are considered for 1500 F thermal storage systems. Latent heat storage with NaF-MgF2 phase change materials are explored in terms of passive, active, and direct contact designs. Comparisons are made of the effectiveness of thermal storage relative to redox, Na-S, Zn-Cl, and Zn-Br battery storage systems. Molten lead trickling down through a phase change eutectic, the NaF-MgF2, formed the direct contact system. Heat transport in all systems is effected through Inconel pipes. Using a cost goal of 120-150 mills/kWh as the controlling parameter, sensible heat systems with molten salts transport with either Stirling or Brayton engines, or latent heat systems with Stirling engines, and latent heat-Brayton engine with direct contact were favored in the analyses. Battery storage systems, however, offered the most flexibility of applications.

Fujita, T.↗

Conference on Complex Turbulent Flows: Comparison of Computation and Experiment, Stanford University, Stanford, CA, September 14-18, 1981, Proceedings. Volume 2 - Taxonomies, reporters' summaries, evaluation, and conclusions

Computational techniques for simulating turbulent flows were explored, together with the results of experimental investigations. Particular attention was devoted to the possibility of defining a universal closure model, applicable for all turbulence situations; however, conclusions were drawn that zonal models, describing localized structures, were the most promising techniques to date. The taxonomy of turbulent flows was summarized, as were algebraic, differential, integral, and partial differential methods for numerical depiction of turbulent flows. Numerous comparisons of theoretically predicted and experimentally obtained data for wall pressure distributions, velocity profiles, turbulent kinetic energy profiles, Reynolds shear stress profiles, and flows around transonic airfoils were presented. Simplifying techniques for reducing the necessary computational time for modeling complex flowfields were surveyed, together with the industrial requirements and applications of computational fluid dynamics techniques.

Kline, S. J.↗

Comparison of CARS combustion temperatures with standard techniques

This paper describes a comparative study of temperatures measured with Coherent Anti-Stokes Raman Spectroscopy (CARS) and those using standard measurement techniques. CARS temperatures from nitrogen vibrational-rotational spectra have been obtained in a premixed hydrogen-air laboratory flame supported on a flat flame burner over a temperature range from about 1000 K to 2100 K. The techniques used for comparison were sodium line reversal, thin wire thermocouples and heat balance calculations. These studies show a good agreement over the entire temperature range studied.

Antcliff, R. R.↗

Comparison of supercritical airfoil flow calculations with wind-tunnel results

Navier-Stokes calculations have been performed for a supercritical airfoil at a transonic design condition and at a subsonic condition. Wind-tunnel pressure-rail measurements were employed as boundary data in the calculations to account for wall-interference effects. A fine mesh was used so that most details of the flows were resolved, particular attention having been given to the trailing-edge region. Detailed comparisons are made with the experimental data. Good agreement was obtained on the airfoil except at the trailing edge where separation occurred. Flow details in the trailing-edge region are examined and differences are shown to be attributable to the turbulence model employed.

King, L. S.↗

Comparison of spherical double probe electric field measurements with plasma bulk flows in plasmas having densities less than 1 cm-3

For a three-hour period in the magnetotail over which plasma density varied from less than 0.1 to about 1/cu cm, comparisons of ISEE-1 spherical double probe (dawn to dusk) electric field measurements and ISEE-2 plasma flows (converted to electric fields) show the zero lag cross correlation coefficient between 768 second averages of the two data sets to have been 0.93. A statistical relative uncertainty between pairs of points in the two data sets, estimated by only including counting statistics in the plasma measurement and time variations of the observed electric field over the measurement interval, is able to account for at least 75 percent of the deviations between the two data sets. In agreement with simple Langmuir probe theory, it has been found that the spacecraft potential measured over the three-hour interval by the double probe instrument varied as the log of the product of the plasma density and the square root of the electron temperature.

Mozer, F. S.↗

El Chichon eruption cloud - Comparison of lidar and optical thickness measurements for October 1982

Sun photometer and lidar backscatter measurements of the El Chichon volcanic cloud were obtained during an airborne latitude survey. The observations were collected between 46 deg N and 46 deg S from Oct. 19-Nov. 7, 1982. Comparisons between these data sets have been performed. An aerosol optical model was developed for the conversion of the lidar measurements to optical thickness values using numerical aerosol size distribution data and index of refraction information collected with coordinated dustsonde balloon flights. The derived lidar optical thickness values were found to agree with the sun photometer optical thickness values within measurement uncertainties. The lidar derived values ranged from 0.16 at the equator to 0.03 at 30 deg S latitude. Peak values were concentrated between 35 deg N and 10 deg S.

Swissler, T. J.↗

Comparison of heliospheric current sheet structure obtained from potential magnetic field computations and from observed polarization coronal brightness

A comparison is conducted of the structure of the heliospheric current sheet early in sunspot cycle 21 as computed from the observed photospheric magnetic field with a potential field approximation and as inferred from synoptic maps of the observed coronal polarization brightness. On most of the solar rotations compared, the two methods give essentially the same results; the basic shape of the warped current sheet and the amplitude (in solar latitude) of the displacements of the sheet from the solar equator are similar. On one rotation the current sheet computed with the potential field approximation appears to be distorted by a large photospheric region of unbalanced magnetic flux.

Wilcox, J. M.↗

Comparison of winter-nocturnal geostationary satellite infrared-surface temperature with shelter-height temperature in Florida

Geostationary satellite surface temperatures derived from a Visible and Infrared Spin Scan Radiometer (VISSR) sensor (10.5 to 12.6 microns) were compared with 1.5-m air temperatures collected by a thermocouple on a traversing vehicle along rural highway transects in Florida, and with two fixed thermographs located in rural and agricultural areas. Statistical comparisons between satellite and 1.5-m observations yielded a mean correlation coefficient of 0.87 and an average sample standard deviation from regression of 1.57 C during clear nights for four winters (1978-1981). The satellite-temperature image of Lake Okeechobee was compared with its geographic outline for areal image registration. Manual overlays of temporal images were repeatable to within one pixel. Satellite-sensed water temperature of Lake Okeechobee was used as an indicator of satellite radiometer repeatability and stability.

Chen, E.↗

A comparison of high resolution optical and radio observations of W3

High resolution maps of the W3 complex for radio continuum and selected optical emission lines are used to derive the visual extinction A(V), the excitation, and the evolutionary state of the component H II regions. A large diffuse H II region in the east, which is the most highly evolved of this type, is found, together with a southern complex of H II regions and a northern complex of young and compact H II regions still embedded in the W3 molecular core. A comparison of the observed dust distribution with ionized and atomic hydrogen and several other molecules in W3 shows the functional relationship between the C-130 column density and A(V) to be in accord with Strohacker's (1978) result for dark clouds.

Dickel, H. R.↗

Space shuttle entry longitudinal aerodynamic comparisons of flights 1-4 with preflight predictions

The Space Shuttle orbiter flight test program has required the aerodynamicist to take a new approach in determining flight characteristics. A conventional flight test program of slowly and cautiously approaching more severe flight conditions was not possible with the orbiter. On the first four orbital flights, The orbiter entered the atmosphere at approximately Mach 29 and decelerated through the Mach range (the subsonic portion of flight had also been flown by another orbiter vehicle during the Approach and Landing Test Program). Certification for these flights was achieved by an extensive wind tunnel test and analysis program. The initial series of flights of the orbiter were heavily instrumented for the purpose of obtaining accurate aerodynamic data. The flight data derived from the entry Mach range provided comparisons between flight and wind tunnel derived predicted data in the areas of both aerodynamic performance and longitudinal trim.

Romere, P. O.↗

Computation of viscous flow in curved ducts and comparison with experimental data

A three dimensional analysis for fully viscous subsonic internal flow is evaluated. The analysis, designated PEPSIG, solves an approximate form of the Navier-Stokes equations by an implicit spatial marching procedure. Results of calculations are presented for laminar flow through two different circular cross-sectioned 180 degree bends, and for laminar and turbulent flow through circular and square cross-sectioned 22.5 to 22.5 degree S-ducts. Quantitative comparisons with experimental data are shown for all cases. Special emphasis is placed on verifying the ability of the analysis to accurately predict the distorted flow fields resulting from pressure-driven secondary flows.

Towne, C. E.↗

Comparison of secondary flows predicted by a viscous code and an inviscid code with experimental data for a turning duct

A comparison of the secondary flows computed by the viscous Kreskovsky-Briley-McDonald code and the inviscid Denton code with benchmark experimental data for turning duct is presented. The viscous code is a fully parabolized space-marching Navier-Stokes solver while the inviscid code is a time-marching Euler solver. The experimental data were collected by Taylor, Whitelaw, and Yianneskis with a laser Doppler velocimeter system in a 90 deg turning duct of square cross-section. The agreement between the viscous and inviscid computations was generally very good for the streamwise primary velocity and the radial secondary velocity, except at the walls, where slip conditions were specified for the inviscid code. The agreement between both the computations and the experimental data was not as close, especially at the 60.0 deg and 77.5 deg angular positions within the duct. This disagreement was attributed to incomplete modelling of the vortex development near the suction surface.

Schwab, J. R.↗

Comparison of AMSU temperature soundings with those produced by HIRS and AMTS

The new generation of satellite borne radiometers to be launched in the late 1980's or early 1990's are currently planned to have as their main temperature sounding unit the AMSU (Advanced Microwave Sounding Unit). This device consists of two units, one of which contains 11 high spectral and spatial resolution channels which are to be used to produce vertical atmospheric temperature soundings. Other channels are to be used to determine atmospheric liquid water and water vapor amounts, as rain detectors, and for surface emissivity determination. This report, however, shall deal only with the accuracy of temperature retrievals. Toward this end studies have been carried out in which atmospheric temperature profiles were retrieved from simulated radiances for the AMSU channels. As a comparison, atmospheric temperature profiles were retrieved from simulated radiances for the currently operational HIRS infrared sounder as well as the proposed advanced infrared sounder AMTS. All simulations were based on a set of 400 mid-latitude radiosondes.

Reuter, D.↗

Comparison between measured turbine stage performance and the predicted performance using quasi-3D flow and boundary layer analyses

A method for calculating turbine stage performance is described. The usefulness of the method is demonstrated by comparing measured and predicted efficiencies for nine different stages. Comparisons are made over a range of turbine pressure ratios and rotor speeds. A quasi-3D flow analysis is used to account for complex passage geometries. Boundary layer analyses are done to account for losses due to friction. Empirical loss models are used to account for incidence, secondary flow, disc windage, and clearance losses.

Boyle, R. J.↗

A 37.5-kW point design comparison of the nickel-cadmium battery, bipolar nickel-hydrogen battery, and regenerative hydrogen-oxygen fuel cell energy storage subsystems for low Earth orbit

Nickel-cadmium batteries, bipolar nickel-hydrogen batteries, and regenerative fuel cell storage subsystems were evaluated for use as the storage subsystem in a 37.5 kW power system for space station. Design requirements were set in order to establish a common baseline for comparison purposes. The storage subsystems were compared on the basis of effective energy density, round trip electrical efficiency, total subsystem weight and volume, and life.

Manzo, M. A.↗