Laboratory contaminant sensor development Final report
Performance of contaminant sensor with mass spectrometer in diluted contaminant-air mixtures
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Performance of contaminant sensor with mass spectrometer in diluted contaminant-air mixtures
Optical surfaces contamination analysis by holographic interferometry, using fringe patterns for contaminant film thickness and uniformity
Method for purifying water that is contaminated with mineral salts and soluble organic compounds is described. Method consists of high pressure filtration of contaminated water through stabilized porous glass membranes. Procedure for conducting filtration is described. Types of materials by percentage amounts removed from the water are identified.
A passive contamination analysis technique in surface sampling for space simulation was developed and evaluated. The KBr pelletizing technique was extended to include heavy oils for infrared analysis. Transmittance and specular reflectance measurements at 2000 A wavelength were found very sensitive to contamination.
The self-contamination of a spacecraft, defined as the return and deposition of outgassed molecules on its critical surfaces, was investigaed. Theoretical relations for the flux, density, and pressure of the emitted gas as a function of altitude, radius, and distance from the spacecraft surface were developed. The flux of these outgassed molecules which return to the emitting surface was also obtained and shown to be dependent on altitude, dimensions, and on the magnitude of outgassing. The rate of condensation and the time for the formation of a monolayer of the returning molecules can be calculated. The self-contamination of a spacecraft undergoing vacuum chamber test was also analyzed and compared to the equivalent parameters for the orbital conditions.
A 2-year program to prepare chamber A at the NASA Manned Spacecraft Center for Apollo telescope mount thermal-vacuum tests is discussed. This program covers modification to existing chamber systems, the development of facility and chamber operating procedures, the selection of chamber cleaning and control methods, and the development and evaluation of diagnostic instrumentation. Extensive efforts to ensure a minimum contamination environment for the Apollo telescope mount test series are illustrated. Recent thermal-vacuum tests of this chamber at progressive stages of cleanliness have demonstrated the success achieved in reducing the particulate and molecular contamination levels of the basic chamber interior.
The V-3 contamination test was designed to measure the degree to which the vacuum facility might be a source of contamination. One test measurement subsystem consisting of a quadrupole residual gas analyzer, a quartz crystal microbalance, and an ion gage is described.
A technique is described for the simultaneous in situ measurement of film thickness, refractive index, total normal emissivity, visible light scattering, and reflectance of contaminant films on a highly reflective liquid nitrogen-cooled, stainless steel substrate. Emissivities and scattering data were obtained for films of water, carbon dioxide, silicone oil, and a number of aromatic and aliphatic hydrocarbons as a function of film thickness between zero and 20 microns. Water had the greatest effect on emissivity, followed by silicone oil, aliphatic hydrocarbons, aromatic hydrocarbons, and carbon dioxide. Emissivity increased more rapidly with film thickness between zero and 2.5 microns, than at thickness greater than 2.5 microns. Scattering of visible light changed little below 2-microns thickness but increased rapidly with thickness beyond 2 to 3 microns. The effect of contaminant films on passive radiation coolers is discussed.
The problem of optical contamination in the form of particulates in the vicinity of a spacecraft has been a source of concern for any astronomical experiment that must be performed in sunlight. This concern prompted a photographic photometric experiment on Apollo 15 to measure the brightness of the residual contamination cloud as well as the cloud produced by dumping waste water overboard. An upper limit of 10 to the minus 12.3 power B (B designates the brightness of the solar disc) was placed on the residual cloud at a 90 deg sun angle, which is comparable to the zodiacal light. The brightness of the cloud produced by the waste dump was estimated to be 10 to the minus 9.2 power B. It was observed to decrease rapidly to 10 to the -11.6 power B in minutes, then fluctuate in brightness for at least 25 minutes as additional material left the spacecraft. The cloud was observed to consist of individually resolved particle tracks estimated to be particles ranging from millimeters to centimeters in diameter in addition to a background of unresolved particles with an average diameter of 10.5 microns. Most of the tracks proceeded in straight-line paths from the dump nozzle. Several tracks violated this direction, apparently having been scattered by collisions. A few tracks appeared to have definite curvatures, which are believed to be caused by charged particle interactions.
The recovery and reuse of water during long term space flight is discussed. Particular attention was given to obtaining basic information on the volatile impurities in urine samples and in water recovered from urine by distillation. Data also cover laboratory distillation tests to determine the nature and extent of volatile constituents in the distillate and an evaluation of possible problems in distillation due to iodine used for control of microbial contamination. Efforts made to develop design criteria for distillation equipment to minimize the problems of volatile contaminants various methods which might be used for purification subsequent to recovery are included.
The use of Auger spectroscopy to evaluate the effectiveness of plasma cleaning procedures in decontaminating Viking spacecraft is examined. Also investigated was the use of Auger spectroscopy to monitor organic contamination. Results show plasma cleaning can be used effectively to remove organic films and that Auger spectroscopy can be used to monitor organic contamination.
The various factors about space missions and spacecraft involved in the study of nonsterile space flight hardware with respect to their effects on planetary quarantine are reviewed. It is shown that methodology currently exists to evaluate the various potential contamination sources and to take appropriate steps in the design of spacecraft ha rdware and mission parameters so that quarantine constraints are met. This work should be done for each program so that the latest knowledge pertaining to various biological questions is utilized, and so that the specific hardware designs of the program can be assessed. The general trend of specific recommendations include: (1) biasing the launch trajectory away from planet to assure against accidental impact of the spacecraft; (2) selecting planetary orbits that meet quarantine requirements - both for accidental impact and for minimizing contamination probabilities due to ejecta; and (3) manufacturing and handling spacecraft under cleanliness conditions assuring minimum bioload.
Considerable amino-acid contamination in commercially available analytical grade hydrochloric acid (37% HCl) was found. One bottle contained 8,300 nmol of amino-acids per liter. A bottle from another supplier contained 6,700 nmol per liter. The contaminants were mostly protein amino-acids and several unknowns. Data on the volatility of the amino-acids during HCl distillation were also obtained.
Determination of the nature and degree of contamination of mirrors in a vacuum environment in the presence of UV irradiation by outgases from some materials that are candidates for use inside spacecraft and simulated spacecraft environments. A vacuum apparatus was developed for testing contamination of mirrors. Offgases from heated test materials are deposited on a refrigerated mirror, half of which is UV irradiated. Reflectance is measured between 1100 and 25,000 A. Thermofit RNF-100, insulated wire TRT-24-19-V-93, and Eccofoam FS and FPH gave heavier deposits on the nonirradiated mirror. Moxness MS60 SO8, Scotch Tape Y-9050, RTV-577, RTV-41, Stycast 1090, and Epon 934 and 828 gave heavier deposits on the irradiated mirror. Raychem wire 44/0411, polyimide tape X1156, Insulgrease G-640, High Vacuum Silicone Grease, and RTV-602 gave only slight deposits on the irradiated and nonirradiated areas of the mirror.
Computer program estimates quantity of activated charcoal required to control multiple contaminants. Program scans all contaminants by potential parameter value and then orders them from lowest to highest values. It calculates quantity of sorbent required to remove most strongly adsorbed material; and then, using potential plot data, capacity of other materials is calculated on basis of corrected capacity.
The analytical basis for planetary quarantine standards and procedures is presented. The heirarchy of planetary quarantine decisions is explained and emphasis is placed on the determination of mission specifications to include sterilization. The influence of the Sagan-Coleman probabilistic model of planetary contamination on current standards and procedures is analyzed. A classical problem in probability theory which provides a close conceptual parallel to the type of dependence present in the contamination problem is presented.
Infrared absorption spectra of ten individual contaminant materials and four binary mixtures of these have been studied using the internal reflection spectroscopy technique. The effect of ultraviolet radiation on these contaminants has also been studied. It has been observed that all siloxanes, silanes, and esters are drastically affected by ultraviolet irradiation. In most cases polymerization and tar formation results.
The analytical data obtained from both cryogenic and grab sampling of the atmosphere of the Skylab AM/MDA during an 84 hour unmanned chamber run are reported. The level of contaminants found at different points of the test chamber are tabulated. The results indicate that there was no clear trend of increasing or decreasing contaminant levels during the test run.