Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Army Re-tuning™ Implementation Guides

The Army is a large, geographically dispersed organization with 156 installations and over 980 million square feet of building space to operate and maintain. The building stock spans a wide range of vintages and missions, with many serving cross-cutting functions and purposes. To meet Federal mandates and reduction goals organizationally, in recent years the Army has aggressively pursued policy and energy efficiency projects and programs resulting in a 9.6% reduction in energy use intensity (EUI) from fiscal year (FY) 2015 to FY2017. Despite these successes, the Army remains the largest consumer of electricity in the Federal government and spent approximately $1.1 billion in energy-related costs in FY2017 The Pacific Northwest National Laboratory (PNNL), in support of the Assistant Secretary of the Army (Installations, Energy and Environment) (ASA (IE&E)), was tasked with a multi-year study and pilot demonstration to develop a business case for the potential energy and cost reduction benefits from re-tuning™ efforts for the Army. Re tuning is a systematic process aimed at minimizing building energy consumption by identifying and correcting operational problems that plague buildings. The methodology was developed by PNNL research staff in an effort to improve building operational efficiency at no- or low-cost, primarily through building automation system (BAS) controls. The methodology is based on two basic principles: If the equipment is not needed, turn it off; and if the equipment is not needed at full power, turn it down. Implementation of identified low-cost/no-cost operational improvements through the re-tuning process results in increased building energy efficiency, reduced operating costs, and improvement to occupant comfort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Soft Matter Thermal and Mechnical Devices

The participant company, Treau, makes homes and buildings more comfortable with quiet, energy efficient, and easy to install heating and cooling systems. They entered the Cyclotron Road program with an idea for a heat exchanger and compressor and a general idea that the building heating and cooling sector was the best first target market. While at Cyclotron Road, they used the Cyclotron Road program staff and Berkeley Lab expertise to better understand the needs of the heating and cooling equipment market. This was critical to understand who the end customer was, and what features were needed in this market. They were then able to conduct product development with this target market/customer in mind. The Cyclotron Road program was also critical in building a manufacturing and scale-up plan that allowed the participant to build a credible growth and fundraising strategy. By the end of the program, the participant had a working prototype testing at Berkeley Lab’s HVAC testing facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Observations Regarding Commonly Available Materials for Face Shield Emulated-Personal Protective Equipment

The Center for Disease Control has recommended that to reduce potential exposure to COVID-19 the public should wear cloth face coverings in public settings where other social distancing measures are difficult to maintain. These face coverings and other Emulated-Personal Protective Equipment (E-PPE) can be made by using Commonly Available Materials (CAMs). As E-PPE recommendations continue to flood the media, a Sandia COVID-19 LDRD effort, the Sandia E-PiPEline Team, systematically evaluated E-PPE design options considering their effectiveness, durability, build difficulty, build cost, and comfort. Using qualitative and semi-quantitative evaluation tools, results of the investigation are presented here to provide guidelines for home and office construction of E-PPE.

36 MATERIALS SCIENCE↗

Observations Regarding Commonly Available Materials for Face Covering Emulated-Personal Protective Equipment

The Center for Disease Control has recommended that to reduce potential exposure to COVID-19 the public should wear cloth face coverings in public settings where other social distancing measures are difficult to maintain. These face coverings and other Emulated-Personal Protective Equipment (E-PPE) can be made by using Commonly Available Materials (CAMs). As E-PPE recommendations continue to flood the media, a Sandia COVID-19 LDRD effort, the Sandia E-PiPEline Team, systematically evaluated E-PPE design options considering their effectiveness, durability, build difficulty, build cost, and comfort. Using qualitative and semi-quantitative evaluation tools, results of the investigation are presented here to provide guidelines for home and office construction of E-PPE.

36 MATERIALS SCIENCE↗

E-PiPEline: Quick to Market Emulated-PPE using Commonly Available Materials

The Center for Disease Control has recommended the public to wear cloth face coverings in public settings that reduce potential exposure to COVID-19 where other social distancing measures are difficult to maintain (e.g., grocery stores and pharmacies) especially in areas of significant community based transmission. These face coverings and other Emulated-Personal Protective Equipment (EPPE) can be made by using Commonly Available Materials (CAMs). As part of the Sandia COVID-19 LDRD effort (funded under the Materials Science Investment Area), the Sandia E-PiPEline task evaluated E-PPE design options for face coverings and face shields considering their effectiveness, durability, build difficulty, build cost, and comfort. Observations from this investigation are presented here to provide guidelines for home construction of E-PPE. This executive summary includes a brief roadmap of the analysis methodology, two one-page handouts geared to be distributed to the public at large (one for E-PPE face coverings and one for E-PPE face shields), and additional observations regarding the potential solutions for E-PPE face coverings and face shields included to further support the one-page handouts.

60 APPLIED LIFE SCIENCES↗

Ultra-Low SWaP CO 2 Sensing for Demand Control Ventilation (Final Report)

In this project PARC and Energy ETC aimed to develop an ultra-low cost, size, weight, and power (SWaP) printed CO 2 sensor system for occupancy detection to enable Demand Control Ventilation (DCV) on a per-room basis. The CO 2 sensor technology is based on the temperature variation when CO 2 reversibly physisorbs to a highly conductive and high surface area sorbent surface, and is compatible with integration with PARC innovations in printed sensors and flexible electronics, for which PARC is a globally leading research center. The printed CO 2 sensor itself is designed to be compatible with PARC’s “peel-and-stick” platform of ultra-low power, low-cost, distributed sensors, and to facilitate real-time DCV based on overall indoor air quality (IAQ). Previously, PARC has developed flexible hybrid electronics (FHE) compatible materials to measure humidity, temperature, light, strain, and gases such as carbon monoxide, methane, ammonia, and hydrogen sulfide. Through this project, PARC developed FHE-compatible materials to measure CO 2 . Thus, with one <$15 FHE “peel-and-stick” based sensor node, a building management system (BMS) will be able to capture a complete picture of the indoor environment. This includes IAQ, light, temperature, and other comfort factors that impact building operations. Combined with optimized DCV, this low-cost sensor capability can be a key enabler of annual primary energy savings of ~ 0.3-0.4 Quad in commercial buildings while ensuring healthy IAQ. Energy ETC is a leader in supplier-agnostic BMS deployments and will design the commissioning and deployment procedures to maximize system interoperability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Observations Regarding Face Shield Designs Using Commonly Available Materials

A Sandia COVID-19 LDRD effort, the Sandia E-PiPEline Team, systematically evaluated design options for face shields constructed from commonly available materials (CAMs). This study is not focused on face shields for medical applications, and as such, has excluded labeling and flammability considerations suggested by the FDA. Design options for face shields were analyzed with subject matter expert input considering the design's effectiveness (seal around face), reusability (compatibility with solvents, degree of inertness), producibility (ability to obtain materials, build time), cost, and comfort (fit around head, contact surface interface). Observations for the design of face shields using CAMS are provided here.

59 BASIC BIOLOGICAL SCIENCES↗

Observations Regarding Face Covering Designs Using Commonly Available Materials

The Center for Disease Control has recommended that the public should wear cloth face coverings in public settings'. A Sandia COVID-19 LDRD effort, the Sandia E-PiPEline Team, systematically evaluated design options for face coverings constructed from commonly available materials (CAMS). The design options were analyzed with subject matter expert input considering the design's effectiveness (metric fiber density, material construction, and water saturation), reusability (degree of inertness), producibility (ability to obtain materials, build time), cost, and comfort (fit on face, breathability). Observations for the design of face coverings using CAMs are provided here.

59 BASIC BIOLOGICAL SCIENCES↗

Virtual Metering for Monitoring Building Energy Consumption

The United States Department of Energy (DOE) has standard metering requirements of commercial buildings for optimizing energy performance. The guiding principles are to continuously track and optimize energy performance and install building-level meters for electricity, natural gas, and steam. Some buildings at Los Alamos National Laboratory (LANL) have physical submeters monitoring their energy consumption, but these meters have proven to be unreliable. And, in most cases, replacing them has proven to be a slow process. Installing new submeters also requires a temporary lockout of the circuit on which they are being installed. Many buildings at LANL contain laboratories with ongoing experiments or data centers, which makes an equipment power outage nearly impossible to plan. This inability to plan power outages results in long-term submeter failures. Although most submeters are eventually replaced, failures lead to missing consumption data for some unpredictable, extended time. A building automation system (BAS) is a system that provides control and monitoring on a building to maintain the operational performance of the building and occupancy comfort. Many buildings at LANL currently have a BAS, and all new renovations and installs will include installing a BAS if one does not already exist. The intended purpose for a BAS is primarily to monitor the health and efficiency of a building; however, it is also possible to calculate equipment power and energy consumption using BAS information. This project aims to use virtual meters to monitor building energy consumption as a cost-effective and minimally labor-intensive alternative to installing physical submeters. The fault detection and diagnostics tool, SkySpark, provides a centralized database for all the data from the various BAS that are active at LANL. This data includes the information that is needed to create virtual meters for heating, ventilating, and air conditioning (HVAC) systems in most buildings, including heating and cooling loads. 9 This report begins with a detailed summary of the project, including the reasoning, procedure, and results. The specific processes of creating the various virtual meters are then identified. Then the limitations are discussed. And, lastly, the results and future potential are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Development and Field Monitoring in nZEB - US Country report IEA HPT Annex 49 Task 3

The International Energy Agency (IEA) Heat Pumping Technologies (HPT) Annex 49, “Design and Integration of Heat Pumps for Nearly Zero Energy Buildings,” deals with the application of heat pumps (HPs) as a core component of the HVAC system for nearly or net-zero energy buildings. This report covers the Task 3 activities of the US team. Three institutions are involved on the US team and have worked on the following projects. 1) Oak Ridge National Laboratory (ORNL) summarized development activities since the conclusion of IEA HPT Annex 40 for several integrated HP (IHP) systems - electric ground-source IHP and air-source IHP versions and engine-driven AS-IHP version. 2) The University of Maryland partnered with ORNL and Blue Bear Management to develop a personal cooling device called RoCo that can provide personalized conditioned air to occupants in inadequately or unconditioned environments. With RoCo, building facility management can elevate the HVAC thermostat settings without compromising occupants’ thermal comfort. Researchers have found that a 4°F increase in thermostat settings can save 12–30% energy savings. Therefore, RoCo is a promising technology that can help reduce building energy consumption and facilitate achievement of net-zero energy building performance. 3) The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net-Zero Energy Residential Test Facility. Two air-source split-system HPs were installed in a residential, net-zero energy home that was constructed as a laboratory on the NIST campus in Gaithersburg, Maryland. The first HP was a two-stage, 7 kW (2 ton), 15.8 seasonal energy efficiency ratio (SEER), 9.05 heating seasonal performance factor (HSPF) conventionally ducted system; the second HP was a variable-speed, 10.6 kW (3 ton), 14 SEER, 8.35 HSPF, high-velocity ducted system. These two systems operated side by side, using separate supply ducts and a common return duct, on a weekly alternating schedule to condition the home that was operated with very consistent simulated thermal loads. The team wanted to determine whether the high-velocity system could provide comparable energy-use efficiency to the conventional system. The results of this study showed that it did meet the required loads and had slightly greater efficiency; the average cooling coefficient of performance (COP) was (0.40 ± 0.11) higher, and the average heating COP was statistically equal. A new firmware was provided at the end of the heating season that greatly improved the performance of the high-velocity system; its average heating COP went from (1.8 ± 0.9) to (2.5 ± 1.1) at a 95% confidence level. The new firmware heating COP averaged (1.05 ± 0.23) higher than the old firmware over the same outdoor temperatures. The defrost performance is very different for these two systems, yet they consumed equivalent energy per HDD. The conventional system uses a timed-initiate, temperature-terminate algorithm with auxiliary electric resistive heating, whereas the high-velocity system uses calculated evaporator parameters with a hot-gas bypass before a full reverse-cycle defrost with no supplementary resistive heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Review: Sensor Impact on Building Controls and Automatic Fault Detection and Diagnosis (AFDD)

This report summarizes a literature review as a Q1 deliverable of the “Sensor Impact Evaluation and Verification” project. This project’s overarching goal is to develop a framework for investigating the impact of sensor deployment and configuration for building energy optimization, fault detection and diagnosis (FDD), occupants’ thermal comfort, and potential grid efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

E-PiPEline: Face Shields and Face Coverings Using Commonly Available Materials

The Center for Disease Control has recommended that the public should wear cloth face coverings in public settings . Face coverings and face shields can be made by using Commonly Available Materials (CAMs). As part of the Sandia COVID - 19 LDRD effort (funded under the Materials Science Investment Area), the Sandia E - PiPEline task evaluated design options for face coverings and face shields considering their effectiveness, durability, build difficulty, build cost, and comfort. Observations from this investigation are presented here to provide guidelines for home construction of face coverings and face shields

54 ENVIRONMENTAL SCIENCES↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multizone Residential HVAC Modeling

This report will evaluate several building physics modeling tools to determine which are best suited for developing next-generation zoning technology. These modeling tools will be evaluated for their ability to predict room-level thermal loads, HVAC system operation, temperature and comfort predictions, and scalability. Any gaps in the existing tools will be identified and a path forward will be discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

KENO V.a Primer: Performing Calculations using SCALE’s Criticality Safety Analysis Sequence (CSAS5) with Fulcrum

The SCALE code system developed at Oak Ridge National Laboratory is widely used and accepted around the world for criticality safety analyses. The well-known KENO V.a three-dimensional Monte Carlo criticality computer code is one of the primary criticality safety analysis tools in SCALE. The KENO V.a primer is designed to help a new user understand and use the SCALE/KENO V.a Monte Carlo code for nuclear criticality safety analyses. It assumes that the user has a college education in a technical field. There is no assumption of familiarity with Monte Carlo codes in general or with SCALE/KENO V.a in particular. The primer is designed to teach by example, with each example illustrating two or three features of SCALE/KENO V.a that are useful in criticality analyses. The primer is based on SCALE 6.2 and 6.3, which includes the Fulcrum graphical user interface (GUI). Each example uses Fulcrum to provide the framework for preparing input data and viewing output results. Starting with a Quickstart section, the primer gives an overview of the basic requirements for SCALE/KENO V.a input and allows the user to quickly run a simple criticality problem with SCALE/KENO V.a. The sections that follow Quickstart include a list of basic objectives at the beginning that identifies the goal of the section and the individual SCALE/KENO V.a features that are covered in detail in the sample problems in that section. Upon completion of the primer, a new user should be comfortable using Fulcrum to set up criticality problems in SCALE/KENO V.a. The primer provides a starting point for the criticality safety analyst who uses SCALE/KENO V.a. Complete descriptions are provided in the SCALE/KENO V.a manual. Although the primer is self-contained, it is intended as a companion volume to the SCALE/KENO V.a training and documentation. The SCALE manual and training schedule are available at https://scale.ornl.gov. The primer provides specific examples of using SCALE/KENO V.a for criticality analyses; the SCALE/KENO V.a manual provides information on the use of SCALE/KENO V.a and all its modules. The primer also contains an appendix with sample input files. In addition, this primer, its errata and sample inputs are also available at https://code.ornl.gov/scale/primers/kenova.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

KENO-VI Primer: Performing Calculations using SCALE’s Criticality Safety Analysis Sequence (CSAS6) with Fulcrum

The SCALE code system developed at Oak Ridge National Laboratory is widely used and accepted around the world for criticality safety analysis. The well-known KENO-VI three-dimensional Monte Carlo criticality computer code is one of the primary criticality safety analysis tools in SCALE. The KENO-VI primer is designed to help a new user understand and use the SCALE/KENO-VI Monte Carlo code for nuclear criticality safety analysis. It assumes that the user has a college education in a technical field. There is no assumption of familiarity with Monte Carlo codes in general or with SCALE/KENO-VI in particular. The primer is designed to teach by example, with each example illustrating two or three features of SCALE/KENO-VI that are useful in criticality analysis. The primer is based on SCALE 6.2 and 6.3, which includes the Fulcrum graphical user interface. Each example uses Fulcrum to provide the framework for preparing input data and viewing output results. Starting with a Quickstart section, the primer gives an overview of the basic requirements for SCALE/KENO-VI input and allows the user to quickly run a simple criticality problem with SCALE/KENO-VI. Each following section begins with a list of basic objectives identifying the goal of the section and the individual SCALE/KENO-VI features covered in detail in the section’s sample problems. Upon completion of the primer, a new user should be comfortable using Fulcrum to set up criticality problems in SCALE/KENO-VI. The primer provides a starting point for the criticality safety analyst who uses SCALE/KENO-VI. Complete descriptions are provided in the SCALE/KENO-VI manual. Although the primer is self-contained, it is intended as a companion volume to the SCALE/KENO-VI training and documentation. The SCALE manual and training schedule are available at https://scale.ornl.gov. The primer provides specific examples of using SCALE/KENO-VI for criticality analysis; the SCALE/KENO-VI manual provides information on the use of SCALE/KENO-VI and all its modules. The primer also contains an appendix with sample input files. In addition, this primer, its errata, and sample inputs are also available at https://code.ornl.gov/scale/primers/kenovi/.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

E-PiPEline: Quick to Market Face Coverings and Face Shields Using Commonly Available Materials

The Center for Disease Control has recommended that the public should wear cloth face coverings in public settings. Face coverings and face shields can be made by using Commonly Available Materials (CAMs). As part of the Sandia COVID-19 LDRD effort (funded under the Materials Science Investment Area), the Sandia E-PiPEline task evaluated design options for face coverings and face shields considering their effectiveness, durability, build difficulty, build cost, and comfort. Observations from this investigation are presented here to provide guidelines for home construction of face coverings and face shields. This executive summary includes a brief roadmap of the analysis methodology, two one-page handouts geared to be distributed to the public at large (one for face coverings and one for face shields), and additional observations regarding potential solutions for face coverings and face shields included to further support the one-page handouts.

59 BASIC BIOLOGICAL SCIENCES↗

HelioScope Energy Performance Modeling Validation: Cooperative Research and Development Final Report, CRADA Number CRD-17-00685

HelioScope is a unique solar design and energy performance modeling tool that bridges the worlds of research and industry, bringing the most rigorous methods from the performance modeling community to thousands of solar developers of all backgrounds. However, many financial institutions and municipalities are hesitant to accept the energy production modeling results of HelioScope (including shading losses) in place of costly, time-intensive, and/or redundant methods due to lack of vetting from a respected institution like NREL. We expect that the proposed validation exercises will give municipalities and financial institutions the comfort needed to incorporate HelioScope into their operations, thereby significantly reducing the needs of existing and potential HelioScope users' to otherwise obtain information that HelioScope produces automatically. Folsom Labs was selected for a Small Business Voucher from the U.S. Department of Energy for the National Renewable Energy Laboratory to validate the performance of HelioScope’s simulation engine against measured PV system performance.

14 SOLAR ENERGY↗