At least 1,099 records · Page 61

SEASONAL PERFORMANCE SIMULATION OF A GAS-FIRED CHEMISORPTION HEAT PUMP FOR RESIDENTIAL HEATING IN COLD CLIMATE

The gas-fired chemisorption heat pump (CSHP) is a promising technology for high-efficiency cold-climate residential heating. The CSHP utilizes the heat of reversible chemical reactions between sorbent and refrigerant to extract heat from cold ambient and supply high-temperature heat to the indoors. The efficiency of CSHP depends on the ambient and heat rejection temperatures. This study evaluates the seasonal performance of a CSHP by first develop a dynamic system model to generate a performance map for various ambient and heat-supply temperatures; then the bin method is used to evaluate the CSHP seasonal performance in two cold-climate locations for space and water heating.

Yang, Zhiyao↗

Residential Cold-Climate Heat Pump Technology Challenge

Cold-climate heat pumps (CCHPs) provide both space heating and cooling for homes, and incorporate advanced features that allow for improved heating capacity and efficiency at cold weather conditions compared with traditional heat pumps. To advance the adoption of CCHP technologies, DOE is launching the Cold-Climate Heat Pump Technology Challenge as part of the Initiative for Better Energy, Emissions, and Equity (E3 Initiative).

Space conditioning, water heating, HVAC, competiti↗

Design, Construction, and Field Validation of a Blown-In Fiberglass Wall System in a Cold, Wet, and Windy Climate

In the Native Village of Tununak, located on Nelson Island in Southwest Alaska,buildings are exposed to wind-driven rain and snow throughout the year. The Cold Climate Housing Research Center (CCHRC) and Knauf Insulation partnered with the community in 2018 to design a residence for a public safety officer. Construction began in fall 2021 and is scheduled to conclude in summer 2022. The house will use integrated trusses with floor, attic, and wall cavities filled with blown-in fiberglass insulation. Hygrothermal models of the building envelope system demonstrate that the high ambient moisture load will wet the outer edges of the insulation annually regardless of the extent and integrity of exterior weather sealing measures; blown-in fiberglass is expected to be more resilient to this wetting than blown-in cellulose. To verify this, researchers will embed temperature, relative humidity, and moisture sensors in the two windward walls of the house to monitor the ability of the blown-in fiberglass insulation to dry out after wetting events that may have occurred during the transport of the insulation to the building site, storage of the insulation on site, construction process, or after installation in the wall. Sensors will remain in place for two years,documenting the wall's performance over time and verifying the design's potential for use in buildings located in climates where the chance for moisture damage is high. Here, we describe the wall system , design criteria, and the results from the hygrothermal modeling. We share details on the monitoring system's components and the planned management and analysis of data. Finally, we explain how the experiences and data from this project will inform future builds in similar locations.

building design↗

Cold Climate Integrated Heat Pump with Energy Storage for Grid-Responsive Control

An air-source integrated heat pump (ASIHP) is a multifunctional unit, capable of space cooling, space heating, and water heating. We developed a packaged cold climate ASIHP, using a multi-stage compressor, capable of working down to -25°C, and providing 100% rated capacity down to -15°C with a heating COP > 2.2. An innovative system configuration and related controls were developed to solve charge balance in the integrated heat pump, smooth charge migration, and mode transition among multiple working modes. Extensive laboratory investigations for individual modes were performed to verify the performance. Its integrated heating capability provides speedy water heating to meet domestic hot water use and store heating energy in a phase change material ceiling/panel. The heating energy storage can be used to shift the load when the electricity price is high. Based on the performance data and a calibrated model from the laboratory testing, we conducted building energy simulations driven by a model predictive control, using EnergyPlus in one U.S. cold climate zone to investigate the grid-responsive control strategy and estimate the utility cost reduction potential.

Shen, Bo↗

Solarize Fairbanks BRITE: Facilitating Efficient, Resilient Homes in Cold Climates

Solarize Fairbanks began an annual Solarize campaign in the Interior Alaska city in 2020, located in IECC climate zone 8, with a goal to increase the number of solar PV panels in the community. The campaign provides peer support, education, bulk purchase discounts, and simplified installation of solar PV technologies for homes, businesses, and nonprofits. In 2021, the campaign began offering energy audits to building and homeowners with a bulk discount; however, building owners were responsible for pursuing next steps on their own. In 2022, a diverse team of local, state, and federal partners formed a team to create a process to further facilitate energy efficiency improvements alongside solar PV technology. The resulting project, Solarize Fairbanks - Building Resilience for the Interior (BRITE) aims to build out an efficiency component over 3 years. If implemented, it will be the first efficiency add-on to a solarize campaign in Alaska. In year one, the team conducted energy audits of four nonprofits located in the cold climate of Interior Alaska and is providing technical assistance and fundraising for the nonprofits to pursue the recommended retrofits. These audits provided insights on the types of retrofits that could be expected to increase efficiency, comfort, and resiliency of buildings, including LED lighting retrofits, increased envelope insulation, improved building controls, and air source heat pump technology. A pre- and post-retrofit analysis will provide further insight on the energy savings and other benefits of the retrofits. It will also inform the offerings in the following years of the BRITE add-on to Solarize campaigns. In this presentation, program implementers will review the past campaigns of Solarize Fairbanks, summarize the energy efficiency and resiliency analyses of the nonprofit buildings, cover future plans for Solarize Fairbanks BRITE, and provide recommendations for other communities pursuing similar programs.

Alaska↗

The Joint Ninth Aerosol, Clouds, Precipitation and Climate (ACPC) initiative and TRacking Aerosol Convection interactions ExpeRiment (TRACER) Workshop

The joint ninth Aerosols-Clouds-Precipitation-and-Climate (ACPC; http://www.acpcinitiative.org) initiative and TRacking Aerosol Convection interactions ExpeRiment (TRACER; Jensen et al., 2022) workshop was convened from 16–19 May 2023 at Texas Southern University (TSU), Houston, TX, and online to discuss progress towards understanding the interactions among aerosols, clouds, precipitation, and climate.

54 ENVIRONMENTAL SCIENCES↗

A hybrid method to evaluate the life cycle climate performance of heat pumps

Heat pumps have a significant impact on the climate, and numerous studies exist discussing the environmental impact of heat pumps quantitatively. Life Cycle Climate Performance (LCCP) is a widely accepted metric and can evaluate the carbon footprint of heat pumps from cradle to grave. LCCP calculation typically requires inputs like annual energy consumption, the material used, refrigerant type, and charge level, which are usually the intermediate or final results from heat pump simulation tools. Thus, a platform linking the heat pump simulation software, local weather conditions, and LCCP evaluation tool can simplify the heat pump design process, especially for complicated systems. This paper presents an LCCP evaluation tool accessing the outputs from the DOE Heat Pump Design Model and the building loads and temperature bin data from AHRI standard 210/240. As for case studies, this paper investigates the LCCP values and life cycle electricity costs (LCEC) of a given cooling-based heat pump with R410A in five typical US cities. In conclusion, this cooling-based heat pump has the highest LCCP value at Chicago and lowest LCCP value at Seattle. In contrast, the heat pump has the highest LCEC at Seattle and the lowest LCEC at Miami. As a future work, a more comprehensive carbon emission and cost analysis of heat pump systems will be conducted through all major cities around the world.

Shen, Bo↗

Case Studies of Residential Façade Upgrades in Four Climate Zones

This paper reports on a project that explored the viability of insulation and window upgrades during siding retrofits in four case studies across the United States. Thousands of homes are re-sided every year, but only a fraction of consumers add insulation and upgrade the windows at the same time, even though a siding replacement is the ideal time to update the thermal performance of building enclosures. To better understand why more siding retrofits do not include insulation and window upgrades, research staff from several organizations collaborated with the U.S. Department of Energy on a multi-faceted research project that included a cost analysis, workforce analysis, market assessment, and contractor assessment. This paper will review four in-field case studies conducted with contractors actively engaged in home re-siding projects that agreed to add rigid insulation and window upgrades as part of their projects. Findings from the case studies will be presented including contractor perspectives, cost, and technical approaches on projects, located in multiple climate zones including Bellingham WA, Jackson MS, Kalamazoo MI, and Phoenix AZ. All projects involved adding continuous rigid insulation on the exterior walls and installation of new cladding. Cladding types varied from wood and metal to fiber cement, vinyl, and traditional stucco. All homes also received a window upgrade, although upgrades varied depending on the original condition of the windows and climate; upgrades included triple-pane windows, low-e storm windows, and exterior shading. Key findings including technical approaches, opportunities, barriers, and project cost will be presented.

re-siding, insulation, rigid insulation, exterior ↗

PV Reliability and Resilience in Challenging Climates

Challenging climates for Photovoltaics are usually based on climate classification. However, extreme weather events such as high wind, flooding, large hail, extreme snow etc. have become more ubiquitous globally. To study the impact of extraordinary weather events on PV reliability we used two of the largest databases in the USA. First, the National Oceanic and Atmospheric Administration (NOAA) database on extreme weather and secondly, the PV Fleet Data Initiative where we have collected high-resolution PV performance data of more than 8 gigawatts or about 6-7% of all commercial and utility systems in the USA. We analyzed almost 200 systems between 2008-20022 that were immediately impacted by these weather events. The immediate impact (outages) was determined to be about 1% of or a median of approximately 3 days of annual lost production. However, the risk these events pose is exemplified by a long tail where 0.4 % of all systems lost more than 2 weeks annual production. We also found a threshold for high wind (90 km/hr) and hail (25mm), above which we observed significantly higher degradation implying long-term damage to the systems. In addition, we are using satellite imagery to quantify visible damage to PV plants. Finally, we share module, design and installation lessons from some observed case studies to improve extreme weather resilience for PV power systems.

degradation↗

Experimental Investigation on Heating Performance of a Cold Climate Thermoelectric-Assisted Heat Pump

To accelerate the electrification of air source heat pumps (ASHPs) in cold climates across the United States, various initiatives have been launched to enhance the effectiveness of ASHPs. One avenue of research involves incorporating thermoelectric (TE) technology into vapor compression refrigeration cycles. This study aims to assess the heating performance of a cold climate ASHP by employing TE modules as a liquid line subcooler. The tested system is a nominal 4.5-ton split heat pump utilizing R410A, equipped with a scroll compressor and an accumulator. An electronic expansion valve was employed for both cooling and heating modes. Two configurations of TE sub-coolers, one utilizing 2 TE bundles and the other 4 TE bundles, were integrated into the liquid line of the tested system. The heating performance of these configurations was evaluated. The results revealed that activating the TE subcooler led to a notable increase in total heat capacity, reaching 1318 W at -15.0 °C and 1164 W at -19.0 °C. The corresponding TE coefficients of performance (COPs) were 1.76 and 1.63, respectively. The activation of the TE sub-cooler resulted in a slight reduction in the overall system COP, with a decrease ranging from -2.6% to -4.2% for these two temperatures. The system COPs were measured at 2.10 and 1.86 for -15.0 °C and -19.0 °C, respectively. This prototype demonstrated a significant augmentation in heating capacity with a minimal sacrifice in COP.

Hu, Yifeng↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

Validating Simulated Models of Energy Consumption by a Battery Electric Motorcoach: A real-world deployment in a harsh climate.

Many efforts have been made to simulate energy consumption of battery electric buses (BEBs) to optimize their deployment into existing fleets. The models produced, however, are rarely validated against real-world consumption data, limiting their generalizability and widespread application to fleets around the US. Furthermore, a major concern specific to BEBs is the effects of harsh climates on their performance. We build upon the state-of-the-art energy consumption modeling techniques developed for BEBs and apply them to a unique geographic context and a unique electrified vehicle. This geography, climate, and vehicle further the existing understanding of the factors affecting medium- and heavy-duty electric vehicles (MHDEVs) by allowing for new relationships to be tested and by assessing the generalizability of known relationships to new contexts. We find that temperature is less predictive of energy consumption for the battery electric motorcoach (BEM) in the case study environment than it is for BEBs in other studies. A mitigating factor that we presume to be working on the relationship between temperature and energy consumption is the fact that the BEM route does not stop between origin and destination to exchange passengers, and in turn, conditioned cabin air. Our model also incorporates wind speed and direction relative to travel, which is a novel contribution of our methodology. Results from our study are helpful for transit service planners, fleet operators, and logistics firms for improving their ability to predict performance of potential deployments of MHDEVs into existing operations.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Experimental Evaluation of a High-Performance Cold-Climate Heat Pump Using Tandem Vapor-Injection Compressors

A high-performance cold-climate heat pump (CCHP) was developed and experimentally validated through comprehensive laboratory and field testing. The system utilized two equal-size tandem vapor-injection (VI) compressors with an inter-stage flash tank to improve efficiency and capacity retention under subfreezing conditions. Laboratory testing was conducted on a 3-ton prototype in a controlled environmental chamber equipped with calibrated thermocouples, refrigerant-side mass flow and pressure transducers, and precision airflow measurement for energy balance verification. The prototype achieved heating coefficients of performance (COPs) of 4.4 at 47 °F, 3.1 at 17 °F, and 2.0 at –13 °F, while maintaining 88% of its rated heating capacity at –13°F. These results confirm strong low-temperature performance and indicate the potential for significant reductions in electric resistance backup use. A field prototype was installed and monitored in a residential building in Fairbanks, Alaska, during a heating season. Instrumentation included real-time power, temperature, and refrigerant state measurements to evaluate performance under dynamic outdoor conditions. The heat pump operated reliably down to –30 °F, delivering 75% of its rated heating capacity with a COP of 1.8, while maintaining stable operation, effective defrost control, and indoor comfort without auxiliary heating. The combined laboratory and field results demonstrate that the tandem VI compressor configuration provides a practical and energy-efficient approach for residential heat pumps designed for cold and very cold climate regions.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Demographic data of Sedum lanceolatum from 2013 to 2014 under a climate manipulation experiment

Demographic data of Sedum lanceolatum under a climate manipulation experiment (heating and watering). Dataset includes one .csv with demographic data for 232 individuals monitored over 2013-2014 which was used, in part, to draw conclusions in "Elevation effects on vital rate sensitivities generate variation in neighbor effects on population growth rate in Sedum lanceolatum" by Herzog et al. (in review). All data was collected under a watering and warming experiment as part of the Alpine Treeline Warming Experiment at Niwot Ridge, Colorado, USA. There are two main data file formats in this archive: comma-separated values (.csv) which can be read using any simple text editor program, such as TextEdit (Mac) and Notepad (Windows). The .pdf data user’s guide can be read using Adobe Acrobat Reader, or any other compatible software.

54 ENVIRONMENTAL SCIENCES↗

A systematic review of building energy sufficiency towards energy and climate targets

Among the sufficiency, efficiency, and renewable frameworks for reducing energy use and energy-related carbon emissions, Building Energy Sufficiency (BES) is gaining attention from policy makers and engineers. Despite the significant role of the building sector in the success of national energy and climate plans, there is a lack of research on the drivers, technologies, and effective policy instruments required to achieve BES in the building operational phase. To fill this gap, this study presents a systematic review of the definition and paradigm of BES and concludes that BES should address both occupant demand and energy or emissions requirements simultaneously. The characteristics of occupant demand in building services are divided into four dimensions: time and space, quality and quantity, control and adjustment, and flexibility. Technical options regarding the building architecture, the envelope system, and the building energy system are reviewed. Finally, policy implications and recommendations are discussed. As a result, the multiple benefits and multidisciplinary nature of BES justify further research and accelerated policy implementation in developed and developing countries.

54 ENVIRONMENTAL SCIENCES↗

The Realistic Potential of Soil Carbon Sequestration in U.S. Croplands for Climate Mitigation

Existing estimates of the climate mitigation potential from cropland carbon sequestration (C-sequestration) are limited because they tend to assume constant rates of soil organic carbon change over all available cropland area, use relatively coarse land delineations, and often fail to adequately consider the agronomic and socioeconomic dimensions of agricultural land use. This results in an inflated estimate of the C-sequestration potential. We address this gap by defining a more appropriate land base for cover cropping in the United States for C-sequestration purposes: stable croplands in annual production systems that can integrate cover cropping without irrigation. Our baseline estimate of this suitable stable cropland area is 32% of current U.S. cropland extent. Even an alternative, less restrictive definition of stability results in a large reduction in area (44% of current U.S. croplands). Focusing cover crop implementation to this constrained land base would increase durability of associated C-sequestration and limit soil carbon loss from land conversion to qualify for carbon-specific incentives. Applying spatially-variable C-sequestration rates from the literature to our baseline area yields a technical potential of 19.4 Tg CO 2 e yr –1 annually, about one-fifth of previous estimates. We also find the cost of realizing about half (10 Tg CO 2 e yr –1 ) of this potential could exceed 100 USD Mg CO 2 e –1 , an order of magnitude higher than previously thought. While our economic analyses suggest that financial incentives are necessary for large-scale adoption of cover cropping in the U.S., they also imply any C-sequestration realized under such incentives is likely to be additional.

54 ENVIRONMENTAL SCIENCES↗

Causes of Reduced Climate Sensitivity in E3SM From Version 1 to Version 2

The effective climate sensitivity in the Department of Energy's Energy Exascale Earth System Model (E3SM) has decreased from 5.3 K in version 1 to 4.0 K in version 2. This reduction is mainly due to a weaker positive cloud feedback that leads to a stronger negative radiative feedback. Present-day atmosphere-only experiments with uniform 4 K sea surface temperature warming are used to separate the contributions of individual model modifications to the reduced cloud feedback. We find that the reduced cloud feedback is mostly driven by changes over the tropical marine low cloud regime, mainly related to a new trigger function for the deep convection scheme and modifications in the cloud microphysics scheme. The new trigger function helps weaken the low cloud reduction by increasing the cloud water detrainment at low levels from deep convection under warming. Changes to the formula of autoconversion rate from liquid to rain and an introduced minimum cloud droplet number concentration threshold in cloud microphysical calculations help sustain clouds against dissipation by suppressing precipitation generation with warming. In the midlatitudes, the increased Wegener-Bergeron-Findeisen (WBF) efficiency strongly reduces present-day liquid water and leads to a stronger negative cloud optical depth feedback. The reduced trade cumulus cloud feedback in v2 is closer to estimates from recent observational and large-eddy modeling studies but might not be due to the right physical reasons. The reduced mid-latitude cloud feedback may be more plausible because more realistic present-day mixed-phase clouds are produced through the change in the WBF efficiency.

54 ENVIRONMENTAL SCIENCES↗