Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Build System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Concentrating Solar Power: Best Practices Handbook for the Collection and Use of Solar Resource Data (CSP)

As the world looks for low-carbon sources of energy, solar power stands out as the most abundant energy resource. Harnessing this energy is the challenge for this century. Photovoltaics and concentrating solar power (CSP) are two primary forms of electricity generation using sunlight. These use different technologies, collect different fractions of the solar resource, and have different siting and production capabilities. Although PV systems are most often deployed as distributed generation sources, CSP systems favor large, centrally located systems. Accordingly, large CSP systems require a substantial investment, sometimes exceeding $1 billion in construction costs. Before such a project is undertaken, the best possible information about the quality and reliability of the fuel source must be made available. That is, project developers need to have reliable data about the solar resource available at specific locations to predict the daily and annual performance of a proposed CSP plant. Without these data, no financial analysis is possible. This handbook presents detailed information about solar resource data and the resulting data products needed for each stage of the project.

14 SOLAR ENERGY↗

Event-Based Energy Impact Tracking and Forecasting with Limited Measurements for Rooftop Units

Packaged air conditioning units and heat pumps, also known as rooftop units (RTUs), are responsible for almost 133 billion kWh of electricity usage annually on site for space cooling U.S. commercial buildings. In addition, the use of heat pumps is a trend we expect to accelerate as buildings transition from fossil fuel-based heating to electricity as a key step for decarbonizing the U.S. commercial buildings sector. However, the operation conditions and energy use of RTUs and heat pumps are usually not well monitored as they are not commonly integrated with building automation systems and lack exposed sensing and control points. To fill this gap, this paper proposes a framework for tracking and forecasting energy impacts resulting from degradation of performance and improved performance for unit servicing using limited data. The proposed framework makes use of a constrained dataset, specifically measurements of the outdoor air temperature and the power demand of individual RTUs, to track and forecast changes in energy use associated with changes in performance over various temporal horizons ranging from days to weeks. Following the detection of an RTU fault, performance degradation, or performance improvement, the framework employs a prediction model to assess the cumulative energy impact. We demonstrate the effectiveness of the method with field-collected data for servicing and degradation examples and compare the predicting accuracy of Gradient Boosting Decision Tree (GBDT) Regression models to Support Vector Regression and Linear Regression models. The results show that GBDT achieved the best accuracy for time-series validation datasets for the servicing and degradation cases, and the prediction model was able to track the cumulative energy impacts of events. The proposed framework can inform building owners of the cumulative change in energy usage of RTUs associated with performance degradation, performance improvement, or a fault.

packaged air conditioners, packaged heat pumps, ro↗

A high sensitivity momentum flux measuring instrument for plasma thruster exhausts and diffusive plasmas

A high sensitivity momentum flux measuring instrument based on a compound pendulum has been developed for use with electric propulsion devices and radio frequency driven plasmas. A laser displacement system, which builds upon techniques used by the materials science community for surface stress measurements, is used to measure with high sensitivity the displacement of a target plate placed in a plasma thruster exhaust. The instrument has been installed inside a vacuum chamber and calibrated via two different methods and is able to measure forces in the range of 0.02-0.5 mN with a resolution of 15 {mu}N. Measurements have been made of the force produced from the cold gas flow and with a discharge ignited using argon propellant. The plasma is generated using a Helicon Double Layer Thruster prototype. The instrument target is placed about 1 mean free path for ion-neutral charge exchange collisions downstream of the thruster exit. At this position, the plasma consists of a low density ion beam (10%) and a much larger downstream component (90%). The results are in good agreement with those determined from the plasma parameters measured with diagnostic probes. Measurements at various flow rates show that variations in ion beam velocity and plasma density and the resulting momentum flux can be measured with this instrument. The instrument target is a simple, low cost device, and since the laser displacement system used is located outside the vacuum chamber, the measurement technique is free from radio frequency interference and thermal effects. It could be used to measure the thrust in the exhaust of other electric propulsion devices and the momentum flux of ion beams formed by expanding plasmas or fusion experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop (Poster)

This poster describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1TM. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating Wind and Solar Energy in the U.S. Bulk Power System: Lessons from Regional Integration Studies

Two recent studies sponsored by the U.S. Department of Energy (DOE) and the National Renewable Energy Laboratory (NREL) have examined the impacts of integrating high penetrations of wind and solar energy on the Eastern and Western electric grids. The Eastern Wind Integration and Transmission Study (EWITS), initiated in 2007, examined the impact on power system operations of reaching 20% to 30% wind energy penetration in the Eastern Interconnection. The Western Wind and Solar Integration Study (WWSIS) examined the operational implications of adding up to 35% wind and solar energy penetration to the Western Interconnect. Both studies examined the costs of integrating variable renewable energy generation into the grid and transmission and operational changes that might be necessary to address higher penetrations of wind or solar generation. This paper identifies key insights from these regional studies for integrating high penetrations of renewables in the U.S. electric grid. The studies share a number of key findings, although in some instances the results vary due to differences in grid operations and markets, the geographic location of the renewables, and the need for transmission.

14 SOLAR ENERGY↗

Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop: Part III – Grid Interconnection System Evaluator

This paper describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

14 SOLAR ENERGY↗

Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop: Part III -- Grid Interconnection System Evaluator: Preprint

This paper, presented at the IEEE Green Technologies Conference 2013, describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1 (TM). The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Review of Variable Generation Integration Charges

The growth of wind and solar generation in the United States, and the expectation of continued growth of these technologies, dictates that the future power system will be operated in a somewhat different manner because of increased variability and uncertainty. A small number of balancing authorities have attempted to determine an 'integration cost' to account for these changes to their current operating practices. Some balancing authorities directly charge wind and solar generators for integration charges, whereas others add integration charges to projected costs of wind and solar in integrated resource plans or in competitive solicitations for generation. This report reviews the balancing authorities that have calculated variable generation integration charges and broadly compares and contrasts the methodologies they used to determine their specific integration charges. The report also profiles each balancing authority and how they derived wind and solar integration charges.

14 SOLAR ENERGY↗

Isolation and characterization of 24 phages infecting the plant growth-promoting rhizobacterium Klebsiella sp. M5al

Bacteriophages largely impact bacterial communities via lysis, gene transfer, and metabolic reprogramming and thus are increasingly thought to alter nutrient and energy cycling across many of Earth’s ecosystems. However, there are few model systems to mechanistically and quantitatively study phage-bacteria interactions, especially in soil systems. Here, we isolated, sequenced, and genomically characterized 24 novel phages infectingKlebsiellasp. M5al, a plant growth-promoting, nonencapsulated rhizosphere-associated bacterium, and compared many of their features against all 565 sequenced, dsDNAKlebsiellaphage genomes. Taxonomic analyses revealed that theseKlebsiellaphages belong to three known phage families (Autographiviridae,Drexlerviridae, andStraboviridae) and two newly proposed phage families (CandidatusMavericviridaeand Ca.Rivulusviridae). At the phage family level, we found that core genes were often phage-centric proteins, such as structural proteins for the phage head and tail and DNA packaging proteins. In contrast, genes involved in transcription, translation, or hypothetical proteins were commonly not shared or flexible genes. Ecologically, we assessed the phages’ ubiquity in recent large-scale metagenomic datasets, which revealed they were not widespread, as well as a possible direct role in reprogramming specific metabolisms during infection by screening their genomes for phage-encoded auxiliary metabolic genes (AMGs). Even though AMGs are common in the environmental literature, only one of our phage families,Straboviridae, contained AMGs, and the types of AMGs were correlated at the genus level. Host range phenotyping revealed the phages had a wide range of infectivity, infecting between 1–14 of our 22 bacterial strain panel that included pathogenicKlebsiellaandRaoultellastrains. This indicates that not all capsule-independent Klebsiella phages have broad host ranges. Together, these isolates, with corresponding genome, AMG, and host range analyses, help build theKlebsiellamodel system for studying phage-host interactions of rhizosphere-associated bacteria.

Science & Technology - Other Topics↗

Adaptive Solar Energy and Power Storage Platform for Multimetered Properties

Veritel Energy LLC has successfully demonstrated the feasibility of its innovative adaptive solar energy and power storage platform designed for multimetered properties in Phase I of its DOE SBIR grant. The project centered around the development and initial deployment of proprietary hardware and software system that manages and distributes site-generated renewable energy to multiple tenants efficiently. This system integrates seamlessly with existing building infrastructure and utility systems, making it a viable solution for aging multifamily properties often located in at-risk communities. The pilot system was installed in a multifamily building with a single master-meter, and functioned as a pilot to demonstrate a scalable model for renewable energy system adoption across similar properties. This installation not only showed potential for significant reductions in greenhouse gas emissions but also improved the economic viability of renewable installations by allowing property owners to recoup investments through increased energy savings and tenant billing. The Phase I project set the groundwork for further enhancements and testing in Phase II which will aim to apply the technology to projects with dozens of sub-meters, further contributing to the decarbonization of the built environment.

14 SOLAR ENERGY↗

Robustness of energy performance of Zero-Net-Energy (ZNE) homes

Zero-net-energy (ZNE) homes produce an adequate amount of energy on-site to meet their energy demand based on source energy for an entire year. California building energy efficiency standards require new residential buildings started in 2020 to be ZNE. For various reasons, a home designed as ZNE may not achieve ZNE performance in real operation. Here we aimed to quantify the robustness of the energy performance of ZNE homes due to weather variability, climate change, and the uncertainty of occupant behavior. A single-family ZNE house, based on the optimal cost-effective design in three California climate zones, was used to develop the EnergyPlus simulation models. Weather variations were considered from a combination of the historical 30 years’ actual meteorological year (AMY) weather data, typical year weather data in TMY3, and future weather data based on Intergovernmental Panel on Climate Change scenarios. Three scenarios of occupant behavior from the energy perspective were defined to represent the uncertainty about occupants’ activities, comfort requirements, and their adaptive interactions with buildings and systems. In terms of annual source energy, the simulation results of the ZNE homes showed: (1) a decrease of 23–38 percent for occupants with energy austerity behavior and an increase of 120–130 percent for occupants with energy wasteful behavior, compared with the baseline assumption of normal occupants; (2) a variation range of –15 percent to +14 percent for the results using 30-year AMY weather data compared with the baseline results using TMY3 weather data; (3) an increase of 10–13 percent with future weather in Fresno and Riverside and a decrease of 15 percent with San Francisco; and (4) climate change can reduce the gap between the austerity and wasteful consumption. These findings provide insights into how ZNE homes may perform in reality and inform architects, engineers, occupants, and policymakers to pay more attention to occupant behavior on design, operation, and regulations of ZNE homes to ensure energy performance robustness.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Leakage and Air Transfer Between Garage and Living Space

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermally reconfigurable monoclinic nematic colloidal fluids

Fundamental relationships are believed to exist between the symmetries of building blocks and the condensed matter phases that they form. For example, constituent molecular and colloidal rods and disks impart their uniaxial symmetry onto nematic liquid crystals, such as those used in displays. Low-symmetry organizations could form in mixtures of rods and disks, but entropy tends to phase-separate them at the molecular and colloidal scales, whereas strong elasticity-mediated interactions drive the formation of chains and crystals in nematic colloids. To have a structure with few or no symmetry operations apart from trivial ones has so far been demonstrated to be a property of solids alone, but not of their fully fluid condensed matter counterparts, even though such symmetries have been considered theoretically and observed in magnetic colloids. In this work, we show that dispersing highly anisotropic charged colloidal disks in a nematic host composed of molecular rods provides a platform for observing many low-symmetry phases. Depending on the temperature, concentration and surface charge of the disks, we find nematic, smectic and columnar organizations with symmetries ranging from uniaxial to orthorhombic and monoclinic. With increasing temperature, we observe unusual transitions from less- to more-ordered states and re-entrant phases. Most importantly, we demonstrate the presence of reconfigurable monoclinic colloidal nematic order, as well as the possibility of thermal and magnetic control of low-symmetry self-assembly. Our experimental findings are supported by theoretical modelling of the colloidal interactions between disks in the nematic host and may provide a route towards realizing many low-symmetry condensed matter phases in systems with building blocks of dissimilar shapes and sizes, as well as their technological applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accelerating Resilience of the Community through Holistic Engagement and use of Renewables (ARCHER) Planning Framework

The primary objective of the Accelerating Resilience of the Community through Holistic Engagement and Use of Renewables (ARCHER) initiative was to identify and incorporate the unique variations in energy burden, social vulnerability, living conditions, and access to essential services that differ across communities. By accounting for these localized factors—down to the neighborhood level—the project supports more targeted and effective investments in community resilience. The framework seeks to establish practical planning guidance, methods, and performance measures for community energy resilience, integrate community-level and electric utility system resilience planning, and assess its effectiveness through comparison with conventional and operational planning approaches. A key component of the project was its data exchange platform, which is used to evaluate and demonstrate the tools, methodologies, and planning approaches developed through ARCHER. This open-source platform enables developers and vendors of distribution and outage management systems to build upon the research by incorporating its concepts into their own tools and workflows. This capability is enabled by the transparent availability of data, functional requirements, and the underlying information model. The project yielded several important insights. First, meaningful engagement with communities is essential to achieving comprehensive resilience outcomes. Second, resilience planning is most effective when electric grid considerations and broader community needs are addressed in a coordinated manner. Third, the use of platforms that allow for real-time input from communities can enhance utility responsiveness during restoration activities. Fourth, a structured and systematic planning approach can successfully translate ARCHER concepts into practice. Fifth, the development of an integrated metric that reflects both grid performance and community impacts provides a more holistic basis for evaluating resilience. Finally, incorporating community engagement and equity considerations into grid operations is critical, particularly during severe weather events that result in extended outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Statistical Characterization of Solar Photovoltaic Power Variability at Small Timescales: Preprint

Integrating large amounts of variable and uncertain solar photovoltaic power into the electricity grid is a growing concern for power system operators in a number of different regions. Power system operators typically accommodate variability, whether from load, wind, or solar, by carrying reserves that can quickly change their output to match the changes in the solar resource. At timescales in the seconds-to-minutes range, this is known as regulation reserve. Previous studies have shown that increasing the geographic diversity of solar resources can reduce the short term-variability of the power output. As the price of solar has decreased, the emergence of very large PV plants (greater than 10 MW) has become more common. These plants present an interesting case because they are large enough to exhibit some spatial smoothing by themselves. This work examines the variability of solar PV output among different arrays in a large ({approx}50 MW) PV plant in the western United States, including the correlation in power output changes between different arrays, as well as the aggregated plant output, at timescales ranging from one second to five minutes.

14 SOLAR ENERGY↗

Technology Solutions Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland

In this project, Building Science Corporation worked with production homebuilder K. Hovnanian to evaluate air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multipoint fan pressurization tests and additional zone pressure diagnostic testing measured the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

air leakage↗

Building America Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland (Fact Sheet)

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Leakage and Air Transfer Between Garage and Living Space

This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗