Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Preliminary study of an angiographic and angio-tomographic technique based on K-edge filters

Digital Subtraction Angiography is commonly affected by artifacts due to the patient movements during the acquisition of the images without and with the contrast medium. This paper presents a preliminary study on an angiographic and angio-tomographic technique based on the quasi-simultaneous acquisition of two images, obtained using two different filters at the exit of an X-ray tube. One of the two filters (K-edge filter) contains the same chemical element used as a contrast agent (gadolinium in this study). This filter absorbs more radiation with energy just above the so called K-edge energy of gadolinium than the radiation with energy just below it. The other filter (an aluminium filter in this study) is simply used to suppress the low-energy contribution to the spectrum. Using proper calibration curves, the two images are combined to obtain an image of the contrast agent distribution. In the angio-tomographic application of the proposed technique two images, corresponding to the two filter types, are acquired for each viewing angle of the tomographic scan. From the two tomographic reconstructions, it is possible to obtain a three-dimensional map of the contrast agent distribution. The technique was tested on a sample consisting of a rat skull placed inside a container filled with water. Six small cylinders with 4.7 mm internal diameter containing the contrast medium at different concentrations were placed inside the skull. In the plain angiographic application of the technique, five out of six cylinders were visible, with gadolinium concentration down to 0.96%. In the angio-tomographic application, all six cylinders were visible, with gadolinium concentration down to 0.49%. This preliminary study shows that the proposed technique can provide images of the contrast medium at low concentration without most of the artifacts that are present in images produced by conventional techniques. The results encourage further investigation on the feasibility of a clinical implementation of the technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of the mitral valve on diastolic flow patterns

The leaflets of the mitral valve interact with the mitral jet and significantly impact diastolic flow patterns, but the effect of mitral valve morphology and kinematics on diastolic flow and its implications for left ventricular function have not been clearly delineated. In the present study, we employ computational hemodynamic simulations to understand the effect of mitral valve leaflets on diastolic flow. A computational model of the left ventricle is constructed based on a high-resolution contrast computed-tomography scan, and a physiological inspired model of the mitral valve leaflets is synthesized from morphological and echocardiographic data. Simulations are performed with a diode type valve model as well as the physiological mitral valve model in order to delineate the effect of mitral-valve leaflets on the intraventricular flow. The study suggests that a normal physiological mitral valve promotes the formation of a circulatory (or “looped”) flow pattern in the ventricle. The mitral valve leaflets also increase the strength of the apical flow, thereby enhancing apical washout and mixing of ventricular blood. The implications of these findings on ventricular function as well as ventricular flow models are discussed.

42 ENGINEERING↗

Effect of laser radiation absorption in water and blood on the optimal wavelength for endovenous obliteration of varicose veins

This work examines laser radiation absorption in water and blood at the wavelengths that are used in endovenous laser treatment (EVLT): 0.81-1.06, 1.32, 1.47, 1.5 and 1.56 {mu}m. It is shown that the best EVLT conditions are ensured by 1.56-{mu}m radiation. Analysis of published data suggests that even higher EVLT efficacy may be achieved at wavelengths of 1.68 and 1.7 {mu}m. (laser medicine)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On pulse duration of self-terminating lasers

The problem of the maximum pulse duration {tau}{sub max} of self-terminating lasers is considered. It is shown that the duration depends on the transition probability in the laser channel, on the decay rate of the resonant state in all other channels, and on the excitation rate of the metastable state. As a result, {tau}{sub max} is found to be significantly shorter than previously estimated. The criteria for converting the 'self-terminating' lasing to quasi-cw lasing are determined. It is shown that in the case of nonselective depopulation of the metastable state, for example in capillary lasers or in a fast flow of the active medium gas, it is impossible to obtain continuous lasing. Some concrete examples are considered. It is established that in several studies of barium vapour lasers ({lambda} = 1.5 {mu}m) and nitrogen lasers ({lambda} = 337 nm), collisional lasing is obtained by increasing the relaxation rate of the metastable state in collisions with working particles (barium atoms and nitrogen molecules). (lasers)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The use of hollow-core photonic crystal fibres as biological sensors

The results of development and study of a new type of a hollow-core photonic crystal fibre with radially increasing diameter of capillaries in the structured cladding are presented. The waveguide possesses a specific transmission spectrum and can be used as an efficient analyser of biological media. (optical technologies in biophysics and medicine)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Speckle-correlation analysis of the microcapillary blood circulation in nail bed

We present the results of the experimental studies of the possibility of monitoring the blood microcirculation in human finger nail bed with application of speckle-correlation analysis, based on estimating the contrast of time-averaged dynamic speckles. The hemodynamics at normal blood circulation and under conditions of partially suppressed blood circulation is analysed. A microscopic analysis is performed to visualise the structural changes in capillaries that are caused by suppressing blood circulation. The problems and prospects of speckle-correlation monitoring of the nail bed microhemodynamics under laboratory and clinical conditions are discussed. (optical technologies in biophysics and medicine)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Second Stokes component generation in the SRS of chirped laser pulses

An experimental investigation was made of optical schemes for the generation of the second Stokes component in the SRS of broadband chirped laser pulses in high-pressure gases. Measurements were made of the energy conversion efficiency and the spatial characteristics of the light beam of the second Stokes component for one- and two-fold focusing of the pump radiation into the gas-filled cell as well as in schemes involving a quartz capillary and two gas-filled cells. The highest energy efficiency of conversion to the second Stokes component was attained in the case of cascade generation in the optical scheme with two pressurised-gas cells. In the SRS in hydrogen in this scheme, the Ti:sapphire laser radiation with a wavelength of 0.79 {mu}m was converted to the 2.3-{mu}m second Stokes component with an efficiency of 8.5%. (nonlinear-optics phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient compression of the femtosecond pulses of an ytterbium laser in a gas-filled capillary

A 290-fs radiation pulse of an ytterbium laser system with a central wavelength of 1028 nm and an energy of 145 {mu}J was compressed to a 27-fs pulse with an energy of 75 {mu}J. The compression was realised on the basis of the effect of pulse spectrum broadening in a xenon-filled glass capillary for a pulse repetition rate of 3kHz. (control of laser radiation parameters)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamics of guiding highly charged ions through SiO{sub 2} nanocapillaries

The time evolution of angular distributions of 7-keV Ne{sup 7+} ions transmitted through SiO{sub 2} nanocapillaries is studied starting with already-charged capillaries, as well as with fully discharged capillaries, under well-defined conditions. We deduce the rearrangement of charge patches for the charged capillaries from the time evolution of the angular distributions. The rearrangement time is found to be orders of magnitude shorter than the discharge time. Combined with a model calculation, we derive quantitative information on the formation of charge patches downstream of the entrance patch during charging-up, starting with the fully discharged capillaries. A pattern of a small number of charge patches guiding ions is deduced in the stationary state of transmission. The model predicts the width and broadening of the transmitted intensity in accord with measurements. We find strong evidence that the deposited charge patches, formed during charge-up, remain localized in the steady state of ion transmission.

36 MATERIALS SCIENCE↗

Guided transmission of 3-keV Ne{sup 7+} ions through nanocapillaries in insulating polymers: Dependence on the capillary diameter

Guiding 3-keV Ne{sup 7+} ions through nanocapillaries in insulating polyethylene terephthalate was investigated as function of the capillary diameter. Highly parallel capillaries with a density of 4x10{sup 6} cm{sup -2} and diameters of 100, 150, 200, 300, and 400 nm were utilized. The characteristic charges governing the charge evolution of the total ion yield were found to be independent of the capillary diameter. However, certain dynamic properties were found to change significantly with this diameter: The transmission profiles of the 100 nm capillaries are broad and structureless, whereas those for 300 nm are composed of three peaks and the mean angle oscillates with deposited charge. At equilibrium the total ion yield was studied as a function of the tilt angle. The results were used to evaluate guiding angles, which were found to be almost constant near 5.5 deg. with varying capillary diameter similarly as the characteristic charge governing the charge evolution. The width of the transmission profiles are found to decrease from 3.3 deg. to 1.7 deg. with increasing capillary diameter from 100 to 400 nm. Model considerations were applied to interpret the results.

36 MATERIALS SCIENCE↗

Capillary instability in a two-component Bose-Einstein condensate

Capillary instability and the resulting dynamics in an immiscible two-component Bose-Einstein condensate are investigated using the mean-field and Bogoliubov analyses. A long, cylindrical condensate surrounded by the other component is dynamically unstable against breakup into droplets due to the interfacial tension arising from the quantum pressure and interactions. A heteronuclear system confined in a cigar-shaped trap is proposed for realizing this phenomenon experimentally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evidence of blocking effects on 3-keV Ne{sup 7+} ions guided through nanocapillaries in polycarbonate

We studied the dynamic properties of ion guiding through nanocapillaries etched in insulating polycarbonate (PC). Capillaries with diameters of 95 and 165 nm and a length of 10 {mu}m were used. In a further sample, the capillaries had a diameter of 175 nm and a length of 30 {mu}m. A few additional measurements were made using capillaries in polyethylene terephthalate (PET). The temporal evolution of the intensity and the angular distribution of the transmitted ions were studied by measuring transmission profiles as a function of the charge deposited on the sample surface. The tilt angle of the capillary axis was varied from 0 deg. to 5 deg. The mean emission angle of the transmission profiles exhibit pronounced oscillations, similarly as in previous measurements using PET. However, for PC, nearly an order of magnitude more charge needs to be inserted into the capillaries to accomplish the oscillations. In contrast to PET, with PC, we observed a strong decrease of the profile intensities with irradiation time. This observation provides evidence of blocking effects on the ions, which are likely to be due to a repulsive field produced by significant charge deposition inside the PC capillaries.

74 ATOMIC AND MOLECULAR PHYSICS↗

Laser-driven plasma waves in capillary tubes

The excitation of plasma waves over a length of up to 8 cm is demonstrated using laser guiding of intense laser pulses through hydrogen-filled glass capillary tubes. The plasma waves are diagnosed by spectral analysis of the transmitted laser radiation. The dependence of the spectral redshift--measured as a function of filling pressure, capillary tube length, and incident laser energy - is in excellent agreement with simulation results. The longitudinal accelerating field inferred from the simulations is in the range of 1-10 GV/m.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of Narrow-Band Terahertz Coherent Cherenkov Radiation from a Cylindrical Dielectric-Lined Waveguide

We report experimental observation of narrow-band coherent Cherenkov radiation driven by a subpicosecond electron bunch traveling along the axis of a hollow cylindrical dielectric-lined waveguide. For an appropriate choice of dielectric wall thickness, a short-pulse beam current profile excites only the fundamental mode of the structure, producing energetic pulses in the terahertz range. We present detailed measurements showing a narrow emission spectrum peaked at 367+-3 GHz from a 1 cm long fused silica capillary tube with submillimeter transverse dimensions, closely matching predictions. We demonstrate a 100 GHz shift in the emitted central frequency when the tube wall thickness is changed by 50 mum. Calibrated measurements of the radiated energy indicate up to 10 muJ per 60 ps pulse for an incident beam charge of 200 pC, corresponding to a peak power of approximately 150 kW.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Closed bore XMR (CBXMR) systems for aortic valve replacement: Active magnetic shielding of x-ray tubes

Hybrid closed bore x-ray/MRI systems are being developed to improve the safety and efficacy of percutaneous aortic valve replacement procedures by harnessing the complementary strengths of the x-ray and MRI modalities in a single interventional suite without requiring patient transfer between two rooms. These systems are composed of an x-ray C-arm in close proximity ({approx_equal}1 m) to an MRI scanner. The MRI magnetic fringe field can cause the electron beam in the x-ray tube to deflect. The deflection causes the x-ray field of view to shift position on the detector receptacle. This could result in unnecessary radiation exposure to the patient and the staff in the cardiac catheterization laboratory. Therefore, the electron beam deflection must be corrected. The authors developed an active magnetic shielding system that can correct for electron beam deflection to within an accuracy of 5% without truncating the field of view or increasing exposure to the patient. This system was able to automatically adjust to different field strengths as the external magnetic field acting on the x-ray tube was changed. Although a small torque was observed on the shielding coils of the active shielding system when they were placed in a magnetic field, this torque will not impact their performance if they are securely mounted on the x-ray tube and the C-arm. The heating of the coils of the shielding system for use in the clinic caused by electric current was found to be slow enough not to require a dedicated cooling system for one percutaneous aortic valve replacement procedure. However, a cooling system will be required if multiple procedures are performed in one session.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic selection of tube potential for radiation dose reduction in CT: A general strategy

Purpose: To optimize radiation dose efficiency in CT while maintaining image quality, it is important to select the optimal tube potential. The selection of optimal tube potential, however, is highly dependent on patient size and diagnostic task. The purpose of this work was to develop a general strategy that allows for automatic tube potential selection for each individual patient and each diagnostic task. Methods: The authors propose a general strategy that allows automatic adaptation of the tube potential as a function of patient size and diagnostic task, using a novel index of image quality, ''iodine contrast to noise ratio with a noise constraint (iCNR{sub N}C),'' to characterize the different image quality requirements by various clinical applications. The relative dose factor (RDF) at each tube potential to achieve a target image quality was then determined as a function of patient size and the noise constraint parameter. A workflow was developed to automatically identify the optimal tube potential that is both dose efficient and practically feasible, incorporating patient size and diagnostic task. An experimental study using a series of semianthropomorphic thoracic phantoms was used to demonstrate how the proposed general strategy can be implemented and how the radiation dose reduction achievable by the tube potential selection depends on phantom sizes and noise constraint parameters. Results: The proposed strategy provides a flexible and quantitative way to select the optimal tube potential based on the patient size and diagnostic task. The noise constraint parameter {alpha} can be adapted for different clinical applications. For example, {alpha}=1 for noncontrast routine exams; {alpha}=1.1-1.25 for contrast-enhanced routine exams; and {alpha}=1.5-2.0 for CT angiography. For the five thoracic phantoms in the experiment, when {alpha}=1, the optimal tube potentials were 80, 100, 100, 120, 120, respectively. The corresponding RDFs (relative to 120 kV) were 78.0%, 90.9%, 95.2%, 100%, and 100%. When {alpha}=1.5, the optimal tube potentials were 80, 80, 80, 100, 100, respectively, with corresponding RDFs of 34.7%, 44.7%, 54.7%, 60.8%, and 89.5%. Conclusions: A general strategy to automatically select the most dose efficient tube potential for CT exams was developed that takes into account patient size and diagnostic task. Dependent on the patient size and the selection of noise constraint parameter for different diagnostic tasks, the dose reduction at each tube potential, quantified explicitly with the RDF, varies significantly.

61 RADIATION PROTECTION AND DOSIMETRY↗

Filtered region of interest cone-beam rotational angiography

Purpose: Cone-beam rotational angiography (CBRA) is widely used in the modern clinical settings. In a number of procedures, the area of interest is often considerably smaller than the field of view (FOV) of the detector, subjecting the patient to potentially unnecessary x-ray dose. The authors therefore propose a filter-based method to reduce the dose in the regions of low interest, while supplying high image quality in the region of interest (ROI). Methods: For such procedures, the authors propose a method of filtered region of interest (FROI)-CBRA. In the authors' approach, a gadolinium filter with a circular central opening is placed into the x-ray beam during image acquisition. The central region is imaged with high contrast, while peripheral regions are subjected to a substantial lower intensity and dose through beam filtering. The resulting images contain a high contrast/intensity ROI, as well as a low contrast/intensity peripheral region, and a transition region in between. To equalize the two regions' intensities, the first projection of the acquisition is performed with and without the filter in place. The equalization relationship, based on Beer's law, is established through linear regression using corresponding filtered and nonfiltered data. The transition region is equalized based on radial profiles. Results: Evaluations in 2D and 3D show no visible difference between conventional FROI-CBRA projection images and reconstructions in the ROI. CNR evaluations show similar image quality in the ROI, with a reduced CNR in the reconstructed peripheral region. In all filtered projection images, the scatter fraction inside the ROI was reduced. Theoretical and experimental dose evaluations show a considerable dose reduction; using a ROI half the original FOV reduces the dose by 60% for the filter thickness of 1.29 mm. Conclusions: These results indicate the potential of FROI-CBRA to reduce the dose to the patient while supplying the physician with the desired image detail inside the ROI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phantom-based experimental validation of computational fluid dynamics simulations on cerebral aneurysms

Purpose: Recently, image-based computational fluid dynamics (CFD) simulation has been applied to investigate the hemodynamics inside human cerebral aneurysms. The knowledge of the computed three-dimensional flow fields is used for clinical risk assessment and treatment decision making. However, the reliability of the application specific CFD results has not been thoroughly validated yet. Methods: In this work, by exploiting a phantom aneurysm model, the authors therefore aim to prove the reliability of the CFD results obtained from simulations with sufficiently accurate input boundary conditions. To confirm the correlation between the CFD results and the reality, virtual angiograms are generated by the simulation pipeline and are quantitatively compared to the experimentally acquired angiograms. In addition, a parametric study has been carried out to systematically investigate the influence of the input parameters associated with the current measuring techniques on the flow patterns. Results: Qualitative and quantitative evaluations demonstrate good agreement between the simulated and the real flow dynamics. Discrepancies of less than 15% are found for the relative root mean square errors of time intensity curve comparisons from each selected characteristic position. The investigated input parameters show different influences on the simulation results, indicating the desired accuracy in the measurements. Conclusions: This study provides a comprehensive validation method of CFD simulation for reproducing the real flow field in the cerebral aneurysm phantom under well controlled conditions. The reliability of the CFD is well confirmed. Through the parametric study, it is possible to assess the degree of validity of the associated CFD model based on the parameter values and their estimated accuracy range.

42 ENGINEERING↗