Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BANDWIDTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

High-Q CMOS-integrated photonic crystal microcavity devices

Integrated optical resonators are necessary or beneficial in realizations of various functions in scaled photonic platforms, including filtering, modulation, and detection in classical communication systems, optical sensing, as well as addressing and control of solid state emitters for quantum technologies. Although photonic crystal (PhC) microresonators can be advantageous to the more commonly used microring devices due to the former’s low mode volumes, fabrication of PhC cavities has typically relied on electron-beam lithography, which precludes integration with large-scale and reproducible CMOS fabrication. Here, we demonstrate wavelength-scale polycrystalline silicon (pSi) PhC microresonators with Qs up to 60,000 fabricated within a bulk CMOS process. Quasi-1D resonators in lateral p-i-n structures allow for resonant defect-state photodetection in all-silicon devices, exhibiting voltage-dependent quantum efficiencies in the range of a few 10 s of %, few-GHz bandwidths, and low dark currents, in devices with loaded Qs in the range of 4,300–9,300; one device, for example, exhibited a loaded Q of 4,300, 25% quantum efficiency (corresponding to a responsivity of 0.31 A/W), 3 GHz bandwidth, and 30 nA dark current at a reverse bias of 30 V. This work demonstrates the possibility for practical integration of PhC microresonators with active electro-optic capability into large-scale silicon photonic systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New localized/delocalized emitting state of Eu 2+ in orange-emitting hexagonal EuAl 2 O 4

Eu 2+ -activated phosphors are being widely used in illuminations and displays. Some of these phosphors feature an extremely broad and red-shifted Eu 2+ emission band; however, convincing explanation of this phenomenon is lacking. Here we report a new localized/delocalized emitting state of Eu 2+ ions in a new hexagonal EuAl 2 O 4 phosphor whose Eu 2+ luminescence exhibits a very large bandwidth and an extremely large Stokes shift. At 77 K, two luminescent sites responsible for 550 nm and 645 nm broadband emissions are recognized, while at room temperature only the 645 nm emission band emits. The 645 nm emission exhibits a typical radiative lifetime of 1.27 μs and an unusually large Stokes shift of 0.92 eV. We identify the 645 nm emission as originating from a new type of emitting state whose composition is predominantly that of localized 4f 6 5d character but which also contains a complementary component with delocalized conduction-band-like character. This investigation gives new insights into a unique type of Eu 2+ luminescence in solids whose emission exhibits both a very large bandwidth and an extremely large Stokes shift.

36 MATERIALS SCIENCE↗

Rate equation model of laser induced bias in uranium isotope ratios measured by resonance ionization mass spectrometry

Resonance Ionization Mass Spectrometry (RIMS) has been developed as a method to measure uranium isotope abundances. In this approach, RIMS is used as an element-selective ionization process between uranium atoms and potential isobars without the aid of chemical purification and separation. The use of broad bandwidth lasers with automated feedback control of wavelength was applied to the measurement of the U-235/U-238 ratio to decrease laser-induced isotopic fractionation. In application, isotope standards are used to identify and correct bias in measured isotope ratios, but understanding laser-induced bias from first-principles can improve the precision and accuracy of experimental measurements. A rate equation model for predicting the relative ionization probability has been developed to study the effect of variations in laser parameters on the measured isotope ratio. The model uses atomic data and empirical descriptions of laser performance to estimate the laser-induced bias expected in experimental measurements of the U-235/U-238 ratio. Empirical corrections are also included to account for ionization processes that are difficult to calculate from first principles with the available atomic data. Development of this model has highlighted several important considerations for properly interpreting experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large two-photon cross sections and low-threshold multiphoton lasing of CdS/CdSe/CdS quantum shells

Colloidal quantum shells are spherical semiconductor quantum wells, which have shown strong promise as optical materials, particularly in classes of experiments requiring multiple excitons. The two-photon properties of CdS/CdSe/CdS quantum shell samples are studied here to demonstrate large non-linear absorption cross-sections while retaining advantageous multiexciton physics conferred by the geometrical structure. The quantum shells have large two-phonon cross sections (0.4–7.9 × 10 6 GM), which highlights their potential use in upconversion imaging in which large per particle two-photon absorption is critical. Time-resolved measurements confirmed that the quantum shells have long biexciton lifetime (>10 ns in the largest core samples reported here) and large gain bandwidth (>300 meV). The combination of these attributes with large two-photon cross sections makes the CdS/CdSe/CdS quantum shells excellent gain media for two-photon excitation. With a broad gain bandwidth and long gain lifetime, quantum shell solids support multimodal amplified spontaneous emission from excitons, biexcitons, and higher excited states. In conclusion, thresholds for amplified spontaneous emission and lasing, which are as low as 1 mJ cm −2 , are comparable to, or lower than, the thresholds reported for other colloidal materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Design of a Distributed Key-Value Store for Petascale Hot Storage in Data Acquisition Systems

Data acquisition systems for high energy physics experiments readout terabytes of data per second from a large number of electronic components. They are thus inherently distributed systems and require fast online data selection, otherwise requirements for permanent storage would be enormous. Still, incoming data need to be buffered while waiting for this selection to happen. Each minute of an experiment can produce hundreds of terabytes that cannot be lost before a selection decision is made. In this context, we present the design of DAQDB (Data Acquisition Database) - a distributed key-value store for high-bandwidth, generic data storage in event-driven systems. DAQDB offers not only high-capacity and low-latency buffer for fast data selection, but also opens a new approach in high-bandwidth data acquisition by decoupling the lifetime of the data analysis processes from the changing event rate due to the duty cycle of the data source. This is achievable by the option to extend its capacity even up to hundreds of petabytes to store hours of an experiment’s data. Our initial performance evaluation shows that DAQDB is a promising alternative to generic database solutions for the high luminosity upgrades of the LHC at CERN.

97 MATHEMATICS AND COMPUTING↗

Scale tests of the new DUNE data pipeline

In preparation for the second runs of the ProtoDUNE detectors at CERN (NP02 and NP04)[1], DUNE has established a new data pipeline for bringing the data from the EHN-1 experimental hall at CERN to primary tape storage at Fermilab and CERN, and then spreading it out to a distributed disk data store at many locations around the world. This system includes a new Ingest Daemon and a new Declaration Daemon. The Rucio[2] replica catalog, and FTS3 transport are used to transport all files. All file metadata is declared to the new MetaCat[3] metadata service. All of these new components have been successfully tested at a scale equal to the expected output of the detector data acquisition system (~2-4 GB/s), and the expected network bandwidth out of the experimental hall. We present the procedure that was used to test and the results of the test.

Timm, Steven↗

Self-adaptive sampling rate data acquisition in JET's correlation reflectometer

Data acquisition systems with self-adaptive sampling rate capabilities have been proposed as a solution to reduce the shear amount of data collected in every discharge of present fusion devices. This paper discusses the design of such a system for its use in the KG8B correlation reflectometer at JET. The system, which is based on the ITMS platform, continuously adapts the sample rate during the acquisition depending on the signal bandwidth. Data are acquired continuously at the expected maximum sample rate and transferred to a memory buffer in the host processor. Thereafter the rest of the process is based on software. Data are read from the memory buffer in blocks and for each block an intelligent decimation algorithm is applied. The decimation algorithm determines the signal bandwidth for each block in order to choose the optimum sample rate for that block, and from there the decimation factor to be used. Memory buffers are used to adapt the throughput of the three main software modules (data acquisition, processing, and storage) following a typical producer-consumer architecture. The system optimizes the amount of data collected while maintaining the same information. Design issues are discussed and results of performance evaluation are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal gradient crystals as tuneable monochromator for high energy X-rays

At the high energy synchrotron radiation beamline BW5 at DORIS III at DESY a new monochromator providing broad energy bandwidth and high reflectivity is in use. On a small 10x10x5 mm{sup 3} silicon crystal scattering at the (311) reflection a thermal gradient is applied, which tunes the scattered energy bandwidth. The (311) reflection strongly suppresses the higher harmonics allowing the use of an image plate detector for crystallography. The monochromator can be used at photon energies above 60 keV.

43 PARTICLE ACCELERATORS↗

Broadband notch filter design for millimeter-wave plasma diagnostics

Notch filters are integrated in plasma diagnostic systems to protect millimeter-wave receivers from intensive stray radiation. Here we present a design of a notch filter with a center frequency of 140 GHz, a rejection bandwidth of {approx}900 MHz, and a typical insertion loss below 2 dB in the passband of {+-}9 GHz. The design is based on a fundamental rectangular waveguide with eight cylindrical cavities coupled by T-junction apertures formed as thin slits. Parameters that affect the notch performance such as physical lengths and conductor materials are discussed. The excited resonance mode in the cylindrical cavities is the fundamental TE{sub 11}. The performance of the constructed filter is measured using a vector network analyzer monitoring a total bandwidth of 30 GHz. We compare the measurements with numerical simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stable coaxial-waveguide gyrotron backward-wave oscillator with distributed losses

This study analyzes the performance of a coaxial-waveguide gyrotron backward-wave oscillator (gyro-BWO) operating at the fundamental harmonic by considering mode competition, which may be attributed to higher-order axial modes and competing transverse modes. In the coaxial waveguide with a short length and uniform cross section, the threshold currents of the higher-order axial modes are substantially higher than the operating current. Additionally, when the beam voltage or the magnetic field is adjusted, the oscillation that neighbors the minimum start-oscillation current of a transverse mode has a positive-k{sub z} field profile, and is excited near the cutoff frequency. As a result, the distributed wall losses at the downstream end of the interaction structure effectively damp the positive-k{sub z} field, and raise significantly the minimum start-oscillation currents of the competing transverse modes. This study also investigates how the parameters, including lossy section length, outer wall resistivity, inner wall resistivity, and ratio of the outer radius to the inner radius, affect the start-oscillation currents of the competing transverse modes in order to obtain stable operation conditions in the frequency tuning range. As is forecasted, when using a 15 A electron beam, the Ka-band coaxial gyro-BWO produces an output power of 137 kW and 3 dB bandwidth of 4.2% by magnetic tuning and an output power of 145 kW and 3dB bandwidth of 2.0% by beam voltage tuning.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calibration of a flat field soft x-ray grating spectrometer for laser produced plasmas

We have calibrated the x-ray response of a variable line spaced grating spectrometer, known as the VSG, at the Fusion and Astrophysics Data and Diagnostic Calibration Facility at the Lawrence Livermore National Laboratory (LLNL). The VSG has been developed to diagnose laser produced plasmas, such as those created at the Jupiter Laser Facility and the National Ignition Facility at LLNL and at both the Omega and Omega EP lasers at the University of Rochester's Laboratory for Laser Energetics. The bandwidth of the VSG spans the range of {approx}6-60 A. The calibration results presented here include the VSG's dispersion and quantum efficiency. The dispersion is determined by measuring the x rays emitted from the hydrogenlike and heliumlike ions of carbon, nitrogen, oxygen, neon, and aluminum. The quantum efficiency is calibrated to an accuracy of 30% or better by normalizing the x-ray intensities recorded by the VSG to those simultaneously recorded by an x-ray microcalorimeter spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high sensitivity ultralow temperature RF conductance and noise measurement setup

We report on the realization of a high sensitivity RF noise measurement scheme to study small current fluctuations of mesoscopic systems at milli-Kelvin temperatures. The setup relies on the combination of an interferometric amplification scheme and a quarter-wave impedance transformer, allowing the measurement of noise power spectral densities with gigahertz bandwidth up to five orders of magnitude below the amplifier noise floor. We simultaneously measure the high frequency conductance of the sample by derivating a portion of the signal to a microwave homodyne detection. We describe the principle of the setup, as well as its implementation and calibration. Finally, we show that our setup allows to fully characterize a subnanosecond on-demand single electron source. More generally, its sensitivity and bandwidth make it suitable for applications manipulating single charges at GHz frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A numerical and experimental study on the nonlinear evolution of long-crested irregular waves

The spatial evolution of nonlinear long-crested irregular waves characterized by the JONSWAP spectrum is studied numerically using a nonlinear wave model based on a pseudospectral (PS) method and the modified nonlinear Schroedinger (MNLS) equation. In addition, new laboratory experiments with two different spectral bandwidths are carried out and a number of wave probe measurements are made to validate these two wave models. Strongly nonlinear wave groups are observed experimentally and their propagation and interaction are studied in detail. For the comparison with experimental measurements, the two models need to be initialized with care and the initialization procedures are described. The MNLS equation is found to approximate reasonably well for the wave fields with a relatively smaller Benjamin-Feir index, but the phase error increases as the propagation distance increases. The PS model with different orders of nonlinear approximation is solved numerically, and it is shown that the fifth-order model agrees well with our measurements prior to wave breaking for both spectral bandwidths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of the validity of quasilinear theory for electron Landau damping in a tokamak using a broad-band wave effect

The quasilinear diffusion coefficient assuming a constant magnetic field along the electron orbit is widely used to describe electron Landau damping of waves in a tokamak where the magnitude of the magnetic field varies on a flux surface. To understand the impact of violating the constant magnetic field assumption, we introduce the effect of a broad-bandwidth wave spectrum which has been used in the past to validate quasilinear theory for the fast decorrelation process between resonances. By the reevaluation of the diffusion coefficient through the level of the phase integral for the tokamak geometry with the broad-band wave effect included, we identify the three acceptable errors for the use of the quasilinear diffusion coefficient.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and characterization of optical heads for interferometric ballistic velocity measurements

The design of optical fiber based heads offering high accuracy and bandwidth for use in VISAR (velocity interferometer system for any reflector) experiments measuring ballistic velocities is described. A new, expanded, model for predicting the distance-dependent collection efficiency of the heads is presented. The model is shown to agree very well with experimental results, both within and outside the ''depth of field''. Various optical heads are demonstrated, to suit different experimental setups and conditions. Designs offering options for high bandwidths, accurate prealignment, and large stand-off distances are discussed. Results from a typical VISAR experiment are presented, verifying that our designs yield high-quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intermediate frequency band digitized high dynamic range radiometer system for plasma diagnostics and real-time Tokamak control

An intermediate frequency (IF) band digitizing radiometer system in the 100-200 GHz frequency range has been developed for Tokamak diagnostics and control, and other fields of research which require a high flexibility in frequency resolution combined with a large bandwidth and the retrieval of the full wave information of the mm-wave signals under investigation. The system is based on directly digitizing the IF band after down conversion. The enabling technology consists of a fast multi-giga sample analog to digital converter that has recently become available. Field programmable gate arrays (FPGA) are implemented to accomplish versatile real-time data analysis. A prototype system has been developed and tested and its performance has been compared with conventional electron cyclotron emission (ECE) spectrometer systems. On the TEXTOR Tokamak a proof of principle shows that ECE, together with high power injected and scattered radiation, becomes amenable to measurement by this device. In particular, its capability to measure the phase of coherent signals in the spectrum offers important advantages in diagnostics and control. One case developed in detail employs the FPGA in real-time fast Fourier transform (FFT) and additional signal processing. The major benefit of such a FFT-based system is the real-time trade-off that can be made between frequency and time resolution. For ECE diagnostics this corresponds to a flexible spatial resolution in the plasma, with potential application in smart sensing of plasma instabilities such as the neoclassical tearing mode (NTM) and sawtooth instabilities. The flexible resolution would allow for the measurement of the full mode content of plasma instabilities contained within the system bandwidth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Femtosecond time-resolved photoelectron spectroscopy with a vacuum-ultraviolet photon source based on laser high-order harmonic generation

A laser-based tabletop approach to femtosecond time-resolved photoelectron spectroscopy with photons in the vacuum-ultraviolet (VUV) energy range is described. The femtosecond VUV pulses are produced by high-order harmonic generation (HHG) of an amplified femtosecond Ti:sapphire laser system. Two generations of the same setup and results from photoelectron spectroscopy in the gas phase are discussed. In both generations, a toroidal grating monochromator was used to select one harmonic in the photon energy range of 20-30 eV. The first generation of the setup was used to perform photoelectron spectroscopy in the gas phase to determine the bandwidth of the source. We find that our HHG source has a bandwidth of 140 {+-} 40 meV. The second and current generation is optimized for femtosecond pump-probe photoelectron spectroscopy with high flux and a small spot size at the sample of the femtosecond probe pulses. The VUV radiation is focused into the interaction region with a toroidal mirror to a spot smaller than 100 x 100 {mu}m{sup 2} and the flux amounts to 10{sup 10} photons/s at the sample at a repetition rate of 1 kHz. The duration of the monochromatized VUV pulses is determined to be 120 fs resulting in an overall pump-probe time resolution of 135 {+-} 5 fs. We show how this setup can be used to map the transient valence electronic structure in molecular dissociation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Glass composition and excitation wavelength dependence of the luminescence of Eu{sup 3+} doped lead borate glass

This work explores the relationship between the bandwidth of luminescence spectral features and their relative intensities, using glasses doped with europium, Eu{sup 3+}, over a wide composition range. Glasses of composition (B{sub 2}O{sub 3}){sub 70}(PbO){sub 29}(0.5Eu{sub 2}O{sub 3}){sub 1} and (B{sub 2}O{sub 3}){sub z}(PbO){sub 99.6-z}(0.5Eu{sub 2}O{sub 3}){sub 0.4}, (z = 20, 30, 40, 60, 70), were prepared by the melting-quenching technique. Variable-wavelength measurements by the prism-coupling method enabled interpolation of refractive index at selected wavelengths. Diffuse reflectance spectra confirmed the incorporation of Eu{sup 3+} into the glass, and scanning electron microscopy displayed that this was in a homogeneous manner. Vibrational spectra showed a change in boron coordination from BO{sub 3} to BO{sub 4} units with increase of PbO content in the glass. Multi-wavelength excited luminescence spectra were recorded for the glasses at temperatures down to 10 K and qualitative interpretations of spectral differences with change of B{sub 2}O{sub 3} content are given. The quantitative analysis of {sup 5}D{sub 0} luminescence intensity-bandwidth relations showed that although samples with higher boron content closely exhibit a simple proportional relationship with band intensity ratios, as expected from theory, the expression needs to be slightly modified for those with low boron content. The Judd-Ofelt intensity analysis of the {sup 5}D{sub 0} emission spectra under laser excitations at low temperature gives {Omega}{sub 2} values within the range from (3.9-6.5) x 10{sup -20} cm{sup 2}, and {Omega}{sub 4} in the range from (4.1-7.0) x 10{sup -20} cm{sup 2}, for different values of z. However, no clear monotonic relation was found between the parameter values and composition. The Judd-Ofelt parameters are compared with those from other systems doped with Eu{sup 3+} and are found to lie in the normal ranges for Eu{sup 3+}-doped glasses. The comparison of parameter values derived from the 10 K spectra with those from room temperature spectra for our glasses, which are fairly constant for different compositions, shows that site selection occurs at low temperature.

36 MATERIALS SCIENCE↗