Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Advanced Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Next-Generation Spaceborne Cloud Profiling Radars

One of the instruments recommended for deployment on the Aerosol/Cloud/Echosystems (ACE) mission is a new advanced Cloud Profiling Radar (ACE-CPR). The atmospheric sciences community has initiated the effort to define the scientific requirements for this instrument. Initial studies focusing on system configuration, performance and feasibility start from the successful experience of the Cloud Profiling Radar on CloudSat Mission (CS-CPR), the first 94-GHz nadir-looking spaceborne radar which has been acquiring global time series of vertical cloud structure since June 2, 2006. In this paper we address the significance of CloudSat's accomplishments in regards to the design and development of radars for future cloud profiling missions such as EarthCARE and ACE.

CloudSat↗

JPL airborne instruments activities

Two instruments intended for flight aboard aircraft for research in advanced remote sensing of the earth are under development: the airborne imaging spectrometer (AIS) and the airborne visible-infrared imaging spectrometer (AVIRIS). The AIS utilizes a 32 x 32 element HgCdTe CCD array to gather 10nm spectral data, initially in the 1.2 to 2.4 micron range, with 32 pixels of cross-track spatial data. The instrument acquires 128 channels of spectral data by using a grating spectrometer whose grating is stepped through four positions during a fraction of an IFOV time on the ground. With an IFOV of 2 mrad, the GIFOV at the design altitude of 3 km is 6m. The instrument has several on-board processing capabilities including ax+b corrections for detector calibration, cross-track and down-track pixel summing, spectral band summing, and variable integration time to allow flight at various altitudes and velocities. The AVIRIS uses a proven scanning mechanism to acquire the spatial data in a whisk broom mode. The spectral coverage is from 0.35 to 2.5 microns at bandwidths ranging from 10 to 20 nm.

Vane, G.↗

Advanced Modes of Electrostatic and Kelvin Probe Force Microscopy for Energy Applications

Since their invention over three decades ago, electrostatic and Kelvin probe force microscopies (EFM and KPFM) have become primary tools for the characterization of electrical phenomena on the nanometer scale, with multiple applications for ferroelectrics, photovoltaics, batteries, and fuel cells among a myriad of other energy-related materials. Meanwhile, the techniques have undergone remarkable advances in terms of resolution, sensitivity, and informational content (e.g., dynamic information). In this chapter, we review the operational principles behind classical EFM/KPFM, including the various excitation/detection schemes, while also highlighting potential cross-talk and instrumental issues. Beyond classical approaches, we will describe more recent advances involving open loop detection, multifrequency/multidimensional excitation, and time-resolved methods. Finally, potential pathways for the further development of EFM/KPFM at the solid-liquid interface are discussed.

Checa, Marti↗

Design of a Parachute Canopy Instrumentation Platform

This paper discusses the current technology available to design and develop a reliable and compact instrumentation platform for parachute system data collection and command actuation. Wireless communication with a parachute canopy will be an advancement to the state of the art of parachute design, development, and testing. Embedded instrumentation of the parachute canopy will provide reefing line tension, skirt position data, parachute health monitoring, and other telemetry, further validating computer models and giving engineering insight into parachute dynamics for both Earth and Mars entry that is currently unavailable. This will allow for more robust designs which are more optimally designed in terms of structural loading, less susceptible to adverse dynamics, and may eventually pave the way to currently unattainable advanced concepts of operations. The development of this technology has dual use potential for a variety of other applications including inflatable habitats, aerodynamic decelerators, heat shields, and other high stress environments.

Alshahin, Wahab M.↗

Development of Bismuth and Platinum Bi-Metallic Nanoparticles to Enhance Melt Wire Temperature Resolution

Advanced manufacturing (AM) based on direct-write (DW) technologies has emerged as the predominant enabler for the fabrication of active and passive sensors to be deployed in harsh operating environments seen in a nuclear reactor. Recently, Idaho National Laboratory and Boise State University have recently established capabilities to incorporate advanced manufacturing (AM) methods to accelerate, modernize and enhance functionality of nuclear sensors and instrumentation to achieve the goal of enhancing the safety and efficiency of nuclear reactors. A significant thrust of this work includes the development of nuclear relevant feedstock materials compatible with a variety of direct-write processes for the development, fabrication and testing of AM sensors for peak temperature detection and neutron flux monitoring. For this report, bismuth and bismuth/platinum (BiPt) bi-metallic nanoparticles were synthesized using wet chemical approaches to develop bi-metallic feedstock materials to enhance the sensitivity of melt wires for peak temperature detection. Nanoparticle characterization was performed with Transmission Electron Microscopy (TEM) for nanoparticle composition and size, Transmission X-Ray Diffraction Fluorescence (TXRF) for nanoparticle composition, and Differential Scanning Calorimetry to elucidate the melting point of BiPt bi-metallic nanoparticles. Preliminary results indicate bi-metallic BiPt nanoparticles as a viable pathway for fabricating high resolution AM melt wires.

36 MATERIALS SCIENCE↗

Digital Twins for Nuclear Power Plants and Facilities

The nuclear digital twin (DT) is the virtual representation of a nuclear energy system across its lifecycle. The nuclear DT uses real-time information and other data sources to improve the process of design, licensing, construction, security, O&M, decommissioning, and waste disposal. By leveraging the knowledge base and experience from the past 40 years of LWR operation, the nuclear DT is helping to accelerate the development and deployment of advanced nuclear technology in areas of passive safety, new fuel forms, instrumentation, and reactor control. For the currently operating nuclear fleet, DTs are reducing the operational risks, increasing plant availability, increasing energy capability, and reducing electricity production costs. For advanced fission and fusion reactors, DTs are being used to design for passive safety and built-in security-by-design. Rapidly deployable small modular reactor (SMR) and microreactor designs compatible with modular construction techniques and advanced manufacturing will be the new normal, reducing the need for large capital expenditures and compressing construction schedules. In addition, lower operational and maintenance costs will be realized by reducing the complexity of operations, staffing needs, and maintenance-related activities.

Kropaczek, Dave↗

Method to Enhance the Operation of an Optical Inspection Instrument Using Spatial Light Modulators

For many aspheric and freeform optical components, existing interferometric solutions require a custom computer-generated hologram (CGH) to characterize the part. The overall objective of this research is to develop hardware and a procedure to produce a combined, dynamic, Hartmann/ Digital Holographic interferometry inspection system for a wide range of advanced optical components, including aspheric and freeform optics. This new instrument would have greater versatility and dynamic range than currently available measurement systems. The method uses a spatial light modulator to pre-condition wavefronts for imaging, interferometry, and data processing to improve the resolution and versatility of an optical inspection instrument. Existing interferometers and Hartmann inspection systems have either too small a dynamic range or insufficient resolution to characterize conveniently unusual optical surfaces like aspherical and freeform optics. For interferometers, a specially produced, computer-generated holographic optical element is needed to transform the wavefront to within the range of the interferometer. A new hybrid wavefront sensor employs newly available spatial light modulators (SLMs) as programmable holographic optical elements (HOEs). The HOE is programmed to enable the same instrument to inspect an optical element in stages, first by a Hartmann measurement, which has a very large dynamic range but less resolution. The first measurement provides the information required to precondition a reference wave that avails the measurement process to the more precise phase shifting interferometry. The SLM preconditions a wavefront before it is used to inspect an optical component. This adds important features to an optical inspection system, enabling not just wavefront conditioning for null testing and dynamic range extension, but also the creation of hybrid measurement procedures. This, for example, allows the combination of dynamic digital holography and Hartmann sensing procedures to cover a virtually unlimited dynamic range with high resolution. Digital holography technology brings all of the power and benefits of digital holographic interferometry to the requirement, while Hartmann-type wavefront sensors bring deflectometry technologies to the solution. The SLM can be used to generate arbitrary wavefronts in one leg of the interferometer, thereby greatly simplifying its use and extending its range. The SLM can also be used to modify the system into a dynamic Shack-Hartmann system, which is useful for optical components with large amounts of slope. By integrating these capabilities into a single instrument, the system will have tremendous flexibility to measure a variety of optical shapes accurately.

Trolinger, James↗

Initial Navigation Alignment of Optical Instruments on GOES-R

Post-launch alignment errors for the Advanced Baseline Imager (ABI) and Geospatial Lightning Mapper (GLM) on GOES-R may be too large for the image navigation and registration (INR) processing algorithms to function without an initial adjustment to calibration parameters. We present an approach that leverages a combination of user-selected image-to-image tie points and image correlation algorithms to estimate this initial launch-induced offset and calculate adjustments to the Line of Sight Motion Compensation (LMC) parameters. We also present an approach to generate synthetic test images, to which shifts and rotations of known magnitude are applied. Results of applying the initial alignment tools to a subset of these synthetic test images are presented. The results for both ABI and GLM are within the specifications established for these tools, and indicate that application of these tools during the post-launch test (PLT) phase of GOES-R operations will enable the automated INR algorithms for both instruments to function as intended.

geolocation↗

Simulation studies of improved sounding systems

Two instrument designs for indirect satellite sounding of the atmosphere in the infrared are represented by the High Resolution Infra-Red Sounder, Model 2 (HIRS-2) and by the Advanced Meteorological Temperature Sounder (AMTS). The relative capabilities of the two instruments were tested by simulating satellite measurements from a group of temperature soundings, allowing the two participants to retrieve the temperature profiles from the simulated data, and comparing the results with the original temperature profiles. Four data sets were produced from radiosondes data extrapolated to a suitable altitude, representing continents and oceans, between 30S and 30N. From the information available, temperature profiles were retrieved by two different methods, statistical regression and inversion of the radiative transfer equation. Results show the consequence of greater spectral purity, concomitant increase in the number of spectral intervals, and the better spatial resolution in partly clouded areas. At the same time, the limitation of the HIRS-2 without its companion instrument leads to some results which should be ignored in comparing the two instruments. A clear superiority of AMTS results is shown.

Yates, H.↗

Spatial Proteomics towards cellular Resolution

Introduction: Spatial biology is an emerging interdisciplinary field facilitating biological discoveries through the use of spatial omics technologies. Recent advancements in spatial transcriptomics, spatial genomics (e.g. genetic mutations and epigenetic marks), multiplexed immunofluorescence, and spatial metabolomics/lipidomics have enabled high-resolution spatial profiling of gene expression, genetic variation, protein expression, and metabolites/lipids profiles in tissue. These developments contribute to a deeper understanding of the spatial organization within tissue microenvironments at the molecular level. Areas covered: This report provides an overview of the untargeted, bottom-up mass spectrometry (MS)-based spatial proteomics workflow. It highlights recent progress in tissue dissection, sample processing, bioinformatics, and liquid chromatography (LC)-MS technologies that are advancing spatial proteomics toward cellular resolution. Expert opinion: The field of untargeted MS-based spatial proteomics is rapidly evolving and holds great promise. To fully realize the potential of spatial proteomics, it is critical to advance data analysis and develop automated and intelligent tissue dissection at the cellular or subcellular level, along with high-throughput LC-MS analyses of thousands of samples. In conclusion, achieving these goals will necessitate significant advancements in tissue dissection technologies, LC-MS instrumentation, and computational tools.

59 BASIC BIOLOGICAL SCIENCES↗

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA↗

DAQs Quick Start Guide

DAQs is a Windows® computer app designed to communicate with the Advanced List Mode Module (ALMM), MC-15, and instrumentation based off these platforms. The ALMM communicates with DAQS over the Ethernet using TCP/IP. If you register the IPv4 address of the ALMM on the local network the ALMM can be operated remotely. However, if the ALMM is not connected to the local network then the computer running DAQs will need to be connected directly to the ALMM or an additional Ethernet adapter will need to be installed on the acquisition computer. The IPv4 address can be changed in the rei.ini file located on the µSD card. Please see the appendices for more information on the rei.ini file. This document is intended to be a quick start guide on how to get an ALMM connected to a computer and how to start a data acquisition. DAQs has much more capability than is presented in this document.

97 MATHEMATICS AND COMPUTING↗

Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor

Neutrons have historically been used for a broad range of biological applications employing techniques such as small-angle neutron scattering, neutron spin echo, diffraction, and inelastic scattering. Unlike neutron scattering techniques that obtain information in reciprocal space, attenuation-based neutron imaging measures a signal in real space that is resolved on the order of tens of micrometers. The principle of neutron imaging follows the Beer-Lambert law and is based on the measurement of the bulk neutron attenuation through a sample. Greater attenuation is exhibited by some light elements (most notably, hydrogen), which are major components of biological samples. Contrast agents such as deuterium, gadolinium, or lithium compounds can be used to enhance contrast in a similar fashion as it is done in medical imaging, including techniques such as optical imaging, magnetic resonance imaging, X-ray, and positron emission tomography. For biological systems, neutron radiography and computed tomography have increasingly been used to investigate the complexity of the underground plant root network, its interaction with soils, and the dynamics of water flux in situ. Moreover, efforts to understand contrast details in animal samples, such as soft tissues and bones, have been explored. This manuscript focuses on the advances in neutron bioimaging such as sample preparation, instrumentation, data acquisition strategy, and data analysis using the High Flux Isotope Reactor CG-1D neutron imaging beamline. The aforementioned capabilities will be illustrated using a selection of examples in plant physiology (herbaceous plant/root/soil system) and biomedical applications (rat femur and mouse lung).

Bilheux, Hassina↗

Requirements for high quality X-ray spectroscopy in an Explorer class mission

Through the use of simulated X-ray spectra the question of instrument requirements for a spectrograph that could significantly advance X-ray astronomy is addressed. It it concluded that resolution (lambda/delta lambda) in the range of 200 to 500, and effective collecting area in excess of 200 sq cm are required. One design, based on the objective reflection grating concept, which would meet these stringent requirements in an Explorer class mission is presented.

Cash, W. C., Jr.↗

Cylindrical Crystal Imaging Spectrometer (CCIS) for cosmic X-ray spectroscopy

A "stigmatic" focusing, Bragg crystal spectrometer was developed and used for high spectral resolution X-ray emission line diagnostics on hot laboratory plasmas. The concept be applied at the focal plane of an orbiting X-ray telescope where it offers several advantages over conventional spectrometers, i.e., mechanical simplicity, high resolving power and sensitivity, simultaneous measurement of an extended segment of spectrum, and good imaging properties. The instrument features a simple, unambiguous, non-scanning spectrum readout that is not adversely affected by either spacecraft pointing error or source extent. The performance of the instrument is estimated in the context of the Advanced X-Ray Astrophysical Facility mission.

Schnopper, H. W.↗

Avionics/crew station integration

The U.S. Navy has been encouraging advanced development concepts aimed at increasing the aircraft instrumentation performance for multi-platform applications of 1990's weapons systems. The three areas covered by the Navy's research and development effort are: System Integration, Technology, and Human Factors. The System Integration objectives are to produce a system architecture easily adaptable to many platforms. Technology objectives are to determine the state of the art for displays, electronics, and controls. The Human Factors objectives are to determine the proper human-machine interfaces so that the ultimate crew station will be capable of providing the pilot with the proper display and controls performance to satisfy the diverse requirements of a fighter, attack, ASW, fixed-wing, rotary-wing, and V/STOL platforms in both a one-man crew or two-man crew matrix. All data/control interface among units of this crew station and other platform subsystems will be via digital data buses and video multiplex buses. No individual discrete signal, data, or control lines will be needed. This paper discusses the six interfaces necessary to ensure the optimum development of this crew station, the predicted platform mission improvements, and the requisite life-cycle cost considerations. This concept will serve as a basis for planning the integration of the necessary hardware and software features in current and future weapons systems.

Mulley, W. G.↗

Observations of deep convection from an airborne high-frequency (92 and 183 GHz) passive microwave radiometer

Spencer et al. (1983) have reported that very low Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) brightness temperatures at 37 GHz over land coincide with heavy thunderstorm rainfall, while Wilheit et al. (1982) used an aircraft-mounted radiometer operating at 92 and 183 GHz to observe convective precipitation associated with a tropical storm over the ocean. A scanning version of the instrument employed by Wilheit et al. is the Advanced Microwave Moisture Sounder (AMMS). The present paper has the objective to summarize the preliminary results of AMMS observations of convective raining clouds and to determine whether empirical relationships between rain rate and microwave brightness temperature, such as those developed for 37 GHz satellite data by Spencer et al., can be extended to higher microwave frequencies.

Hakkarinen, I. M.↗

Unified constitutive materials model development and evaluation for high-temperature structural analysis applications

Unified constitutive material models were developed for structural analyses of aircraft gas turbine engine hot section components with particular application to an isotropic material used for combustor liners. Differential forms of models independently developed were considered in this study. These models combine the interactions of time-dependent (creep) and time-independent (plasticity) inelastic behavior of a material. Predicted stress-strain responses from these models were evaluated against cyclic isothermal and nonisothermal test results for uniaxial specimens of a nickel-base superalloy. The unified models were implemented in a nonlinear structural analysis code. Two unique NASA Lewis test facilities were used in the evaluation of the models for complex geometry specimens and evaluation of advanced temperature and high-temperature strain measurement instrumentation. Predicted nonlinear structural responses from one of the models for a flat plate and a segment of a conventional combustor liner are presented.

Thompson, R. L.↗