Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTERIES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Influence of cigarette smoking on human autonomic function

BACKGROUND. Although cigarette smoking is known to lead to widespread augmentation of sympathetic nervous system activity, little is known about the effects of smoking on directly measured human sympathetic activity and its reflex control. METHODS AND RESULTS. We studied the acute effects of smoking two research-grade cigarettes on muscle sympathetic nerve activity and on arterial baroreflex-mediated changes of sympathetic and vagal neural cardiovascular outflows in eight healthy habitual smokers. Measurements were made during frequency-controlled breathing, graded Valsalva maneuvers, and carotid baroreceptor stimulation with ramped sequences of neck pressure and suction. Smoking provoked the following changes: Arterial pressure increased significantly, and RR intervals, RR interval spectral power at the respiratory frequency, and muscle sympathetic nerve activity decreased. Plasma nicotine levels increased significantly, but plasma epinephrine, norepinephrine, and neuropeptide Y levels did not change. Peak sympathetic nerve activity during and systolic pressure overshoots after Valsalva straining increased significantly in proportion to increases of plasma nicotine levels. The average carotid baroreceptor-cardiac reflex relation shifted rightward and downward on arterial pressure and RR interval axes; average gain, operational point, and response range did not change. CONCLUSIONS. In habitual smokers, smoking acutely reduces baseline levels of vagal-cardiac nerve activity and completely resets vagally mediated arterial baroreceptor-cardiac reflex responses. Smoking also reduces muscle sympathetic nerve activity but augments increases of sympathetic activity triggered by brief arterial pressure reductions. This pattern of autonomic changes is likely to influence smokers' responses to acute arterial pressure reductions importantly.

NASA Discipline Cardiopulmonary↗

Freeze-tolerant condenser for a closed-loop heat-transfer system

A freeze tolerant condenser (106) for a two-phase heat transfer system is disclosed. The condenser includes an enclosure (110) and a porous artery (112) located within and extending along the length of the enclosure. A vapor space (116) is defined between the enclosure and the artery, and a liquid space (114) is defined by a central passageway within the artery. The artery includes a plurality of laser-micromachined capillaries (130) extending from the outer surface of the artery to its inner surface such that the vapor space is in fluid communication with the liquid space. In one embodiment of the invention, the capillaries (130) are cylindrical holes having a diameter of no greater than 50 microns. In another embodiment, the capillaries (130') are slots having widths of no greater than 50 microns. A method of making an artery in accordance with the present invention is also disclosed. The method includes providing a solid-walled tube and laser-micromachining a plurality of capillaries into the tube along a longitudinal axis, wherein each capillary has at least one cross-sectional dimension transverse to the longitudinal axis of less than 50 microns.

Crowley, Christopher J.↗

Metabolomic and Genomic Markers of Atherosclerosis as Related to Oxidative Stress, Inflammation, and Vascular Function in Twin Astronauts

Background: Future human space travel will consist primarily of long-duration missions onboard the International Space Station (ISS) or exploration-class missions to Mars, its moons, or nearby asteroids. Astronauts participating in long-duration missions may be at an increased risk of oxidative stress and inflammatory damage due to radiation, psychological stress, altered physical activity, nutritional insufficiency, and hyperoxia during extravehicular activity. By studying one identical twin during his 1-year ISS mission and one ground-based twin, this work extends a current NASA-funded investigation to determine whether these spaceflight factors contribute to an accelerated progression of atherosclerosis. This study of twins affords a unique opportunity to examine the spaceflight-related atherosclerosis risk independent of the confounding factors associated with different genotypes. Purpose: The purpose of this investigation is to determine whether biomarkers of oxidative and inflammatory stress are elevated during and after long-duration spaceflight and determine if a relation exists between levels of these biomarkers and structural and functional indices of atherosclerotic risk measured in the carotid and brachial arteries. These physiological and biochemical data will be extended by using an exploratory approach to investigate the relationship between intermediate phenotypes and risk factors for atherosclerosis and the metabolomic signature from plasma and urine samples. Since metabolites are often the indirect products of gene expression, we will simultaneously assess gene expression and DNA methylation in leukocytes. Hypothesis: We predict that the space-flown twin will experience elevated biomarkers of oxidative stress and inflammatory damage, altered arterial structure and function, accelerated telomere shortening, dysregulation of genes associated with oxidative stress and inflammation, and a metabolic profile shift that is associated with elevated atherosclerosis risk factors. Conversely, these will not be observed in the ground-based twin. Methods: We will measure blood and urine biomarkers of oxidative stress and inflammation as well as arterial structure and function (carotid intima-medial thickness and brachial artery flow-mediated dilation) in one twin astronaut before, during, and after long-duration spaceflight and in his twin serving as a ground-based control. Furthermore, we will measure metabolomics (targeted and untargeted approaches) and genomic markers (DNA methylation, mRNA gene expression, telomere length) to elucidate the molecular mechanisms involved. A panel of biomarkers of oxidative and inflammatory stress will be measured in venous blood samples and 24-hour (in-flight) and 48-hour (pre- and post-flight) urine pools twice before flight, early (flight days 15 and 60) and late (2 weeks before landing) during the mission, and early in the post-flight recovery phase (approximately 3-5 days after landing). Arterial structure, assessed from measures of intima-media thickness, will be measured at the same times. Arterial function will be assessed using brachial flow-mediated dilation, a well-validated measure used to assess endothelium-dependent vasodilation and a sensitive predictor of atherosclerotic risk, only before and after spaceflight. Discussion: Pre- and in-flight data collection is in progress for the space-flown twin, and similar data have been obtained from the ground-based twin. Blood and urine samples will be batch processed when received from ISS after the conclusion of the 1-year mission. Results from these individual subjects will be compared to the larger complement of subjects participating in the companion study currently ongoing in ISS astronauts.

Lee, Stuart M. C.↗

Systemic Hypertension and Transient Ischemic Attack in a 6-Year-Old Girl with Fibromuscular Dysplasia Treated with Percutaneous Angioplasty

We describe a 6-year-old girl with arterial hypertension secondary to fibromuscular dysplasia with stenoses of both renal arteries and transient ischemic attack due to extracranial right internal carotid artery subtotal occlusion as well as left internal carotid artery stenosis. She was treated with percutaneous angioplasty of both renal and both carotid arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization Materials Made of Gelatin: Comparison Between Gelpart and Gelatin Microspheres

Purpose:The object of this study was to assess the level of embolization in the embolized artery and the degradation period of these two embolic agents in the renal arteries using rabbit models.Materials and Methods: The renal artery was embolized using 5 mg of gelatin microspheres (GMSs; diameter, 35-100 {mu}m; group 1) or 1 mg of Gelpart (diameter, 1 mm; group 2). For each group, angiographies were performed on two kidneys immediately after the embolic procedure and on days 3, 7, and 14 after embolization. This was followed by histopathological examinations of the kidneys.Results:Follow-up angiograms on each day revealed the persistence of poorly enhanced wedge-shaped areas in the parenchymal phase in all cases. In group 1, four of six cases showed poorly enhanced small areas in the follow-up angiograms. In group 2, all cases showed poorly enhanced large areas. In the histopathological specimens, it was observed that immediately after embolization, the particles reached the interlobular arteries in group 1 and the interlobar arteries in group 2. In all cases in group 1, the particles were histologically identified even on day 14. In one case in group 2 on day 14, the particles were not identified.Conclusion:In conclusion, although GMSs and Gelpart were similar in the point of gelatin particles, the level of embolization and the degradation period were different between GMSs and Gelpart.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biocompatibility, Inflammatory Response, and Recannalization Characteristics of Nonradioactive Resin Microspheres: Histological Findings

Intra-arterial radiotherapy with yttrium-90 microspheres (radioembolization) is a therapeutic procedure exclusively applied to the liver that allows the direct delivery of high-dose radiation to liver tumors, by means of endovascular catheters, selectively placed within the tumor vasculature. The aim of the study was to describe the distribution of spheres within the precapillaries, inflammatory response, and recannalization characteristics after embolization with nonradioactive resin microspheres in the kidney and liver. We performed a partial embolization of the liver and kidney vessels in nine white pigs. The left renal and left hepatic arteries were catheterized and filled with nonradioactive resin microspheres. Embolization was defined as the initiation of near-stasis of blood flow, rather than total occlusion of the vessels. The hepatic circulation was not isolated so that the effects of reflux of microspheres into stomach could be observed. Animals were sacrificed at 48 h, 4 weeks, and 8 weeks, and tissue samples from the kidney, liver, lung, and stomach evaluated. Microscopic evaluation revealed clusters of 10-30 microspheres (15-30 {mu}m in diameter) in the small vessels of the kidney (the arciform arteries, vasa recti, and glomerular afferent vessels) and liver. Aggregates were associated with focal ischemia and mild vascular wall damage. Occlusion of the small vessels was associated with a mild perivascular inflammatory reaction. After filling of the left hepatic artery with microspheres, there was some evidence of arteriovenous shunting into the lungs, and one case of cholecystitis and one case of marked gastritis and ulceration at the site of arterial occlusion due to the presence of clusters of microspheres. Beyond 48 h, microspheres were progressively integrated into the vascular wall by phagocytosis and the lumen recannalized. Eight-week evaluation found that the perivascular inflammatory reaction was mild. Liver cell damage, bile duct injury, and portal space fibrosis were not observed. In conclusion, resin microspheres (15-30 {mu}m diameter) trigger virtually no inflammatory response in target tissues (liver and kidney). Clusters rather than individual microspheres were associated with a mild to moderate perivascular inflammatory reaction. There was no evidence of either a prolonged inflammatory reaction or fibrosis in the liver parenchyma following recannalization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Mechanical Thrombectomy Device for Retrieval of Intravascular Thrombus

Purpose: Thrombotic and embolic vascular occlusion represents a leading cause of morbidity and mortality. Currently available thrombectomy devices have limitations, including difficulty removing organized thrombus and clot fragmentation with distal embolization. A novel mechanical thrombectomy device (MTD), designed to remove both hard and soft thrombus without trauma to the blood vessel, was tested in preclinical porcine models evaluating efficacy, safety, and ease of use. Materials and Methods: A total of 26 vessels in 14 pigs underwent mechanical thrombectomy with MTD. Thrombectomy was performed in nine superficial femoral arteries, eight subclavian arteries, five primary branches of the subclavian artery, lateral thoracic artery or the thyrocervical trunk, and four external carotids. Subacute organized fibrin-laden thrombus was injected into the arteries producing vascular occlusion. The MTD was then used for thrombectomy to restore patency and blood flow. Results: Intact thrombus was retrieved from 24 of 26 of the vessels with a single pass of the MTD, resulting in complete restoration of patency in 21 vessels and partial patency in 4 vessels. In 8 cases that used an early design, the embolic material fragmented during withdrawal from the access sheath. In 4 procedures that used an early design, the MTD failed to deploy fully and the embolus was not completely captured. No intraprocedural complications or vascular damage occurred. Conclusions: The present pilot studies demonstrate basic safety and efficacy of a novel MTD with design attributes suitable for retrieval of intact acute and organized chronic thrombus. The device has potential intracranial and peripheral utility.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Postpartum Hemorrhage Treated with Gelfoam Slurry Embolization Using the Superselective Technique: Immediate Results and 1-Month MRI Follow-up

To evaluate the efficacy and safety of superselective embolization of the uterine arteries in a postpartum hemorrhage. Between November 2004 and January 2011, a total of 44 consecutive women (median {+-} standard deviation age 34 {+-} 3 years, range 23-41 years) were referred to our institution for postpartum intractable hemorrhage management. All patients were embolized with a microcatheter that was placed deep into the uterine arteries upstream of the cervical arteries. The embolic agent was a mixture of contrast medium and 5 Multiplication-Sign 5 Multiplication-Sign 5 cm pieces of gelfoam (Gelita-Spon) modified into a gelatin emulsion as follows: rapid mixing through a three-way stopcock with two 2.5-ml syringes. A 1-ml syringe was used for injection. One month after embolization, all patients underwent magnetic resonance imaging and clinical examination. Technical and clinical success was obtained in all cases. Thirty-five patients experienced bleeding related to poor retraction of the uterus, 7 patients because of a tear of the cervix and 2 because of a vaginal hematoma. Pre- and postembolization red blood cell transfusions were (mean {+-} standard deviation [SD]) 6 {+-} 1.2 (range 3-8) U and 2 {+-} 0.7 (range 2-4) U, respectively. One-month magnetic resonance imaging follow-up revealed no sign of ischemic myometrium or necrosis, and no instances of uterine rupture and no pelvic vein thrombosis. Incidental findings included two small intramyometrial hematic collections. All uterine arteries were patent via magnetic resonance angiography. Seventeen patients had concomitant fibroids, all of which appeared hypovascular. This technique permits good, safe clinical results with no marked damage to the uterine arteries or the uterus itself.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gelatin Microspheres: Correlation between Embolic Effect/Degradability and Cross-linkage/Particle Size

PurposeTo evaluate the embolic effect and degradability of gelatin microspheres (GMS) using various degrees of cross-linkage and particle sizes in rabbit renal artery embolization.MethodsFour types of GMS were used, as follows: 2 types of cross-linkage and 2 types of particle size. Twenty-four rabbits (6 in each group) were used for the renal artery embolization. Renal angiography was performed before and after embolization of right renal artery. Follow-up renal angiography was performed 2 days (n = 2), 5 days (n = 2), and 15 days (n = 2) after embolization in each group, and then kidneys were removed for histopathological evaluation. Vascular areas of the angiography were measured by Image J software, and the reperfusion rate was calculated. In renal specimens, residual GMS were checked and the degree of degradation was classified according to a 4-point scale.ResultsThe mean amounts of large- and small-particle-size GMS injected were 15.0 and 34.3 mg, respectively. Tissue necrosis was confirmed in each group; however, no difference was observed among groups. Renal reperfusion was observed more with small GMS than with large GMS. Renal reperfusion was also observed more with low cross-linked GMS than with high cross-linked GMS. In histopathological specimens, large GMS were confirmed in lobar artery, and small GMS were confirmed in lobular artery. Low cross-linked GMS completely degraded 15 days after embolization. In contrast, high cross-linked GMS were persistent 15 days after embolization.ConclusionDegree of cross-linkage and particle size affected degradability and reperfusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Three-Dimensional Rotational Angiography of the Foot in Critical Limb Ischemia: A New Dimension in Revascularization Strategy

Purpose. To evaluate the additional value of three-dimensional rotational angiography (3DRA) of the foot compared with digital subtraction angiography (DSA) in patients with critical limb ischemia (CLI). Technique. For 3DRA, the C-arm was placed in the propeller position with the foot in an isocentric position. The patient's unaffected foot was positioned in a footrest outside the field of view. For correct timing of 3DRA, the delay from contrast injection in the popliteal artery at the level of knee joint to complete pedal arterial enhancement was assessed using DSA. With this delay, 3DRA was started after injection of 15 ml contrast. Imaging of the 3DRA could directly be reconstructed and visualized.Materials and MethodsPatients undergoing 3DRA of the foot were prospectively registered. DSA and 3DRA images were scored separately for arterial patency and presence of collaterals. Treatment strategies were proposed based on DSA with and without the availability of 3DRA. Results. Eleven patients underwent 3DRA of the foot. One 3DRA was not included because the acquisition was focused on the heel instead of the entire foot. Diagnostic quality of 3DRA was good in all ten patients. 3DRA compared with DSA showed additional patent arteries in six patients, patent plantar arch in three patients, and collaterals between the pedal arteries in five patients. Additional information from 3DRA resulted in a change of treatment strategy in six patients. Conclusion, 3DRA of the foot contains valuable additional real-time information to better guide peripheral vascular interventions in patients with CLI and nonhealing tissue lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Periprocedural Prophylactic Antithrombotic Strategies in Interventional Radiology: Current Practice in the Netherlands and Comparison with the United Kingdom

Purpose: The use of prophylactic antithrombotic drugs to prevent arterial thrombosis during the periprocedural period during (percutaneous) peripheral arterial interventions (PAIs) is still a matter of dispute, and clear evidence-based guidelines are lacking. To create those guidelines, a study group was formed in the Netherlands in cooperation with the Dutch Society of Vascular Surgery and the Society of Interventional Radiology. The study group is called 'Consensus on Arterial PeriProcedural Anticoagulation (CAPPA).' Materials and Methods: The CAPPA study group devised and distributed a comprehensive questionnaire amongst Dutch interventional radiologists (IRs). Results: One hundred forty-two IRs responded (68 %) to the questionnaire. Almost no IR stopped acetyl salicylic acid before interventions, and 40 % stopped clopidogrel before PAI but not before carotid artery stenting (CAS). A flushing solution on the sideport of the sheath was used routinely by 30 % of IRs in PAI and by 50 % of IRs during CAS. A minority of IRs used a heparinised flushing solution (28 %). Unfractionated heparin was used by 95 % of IRs as bolus; 5000 IU was the most used dosage. Timing of administration varied widely. A majority of IRs (75 %) repeated heparin administration after 1 h. Conclusion: A substantial variety exists amongst IRs in the Netherlands regarding the use of prophylactic periprocedural antithrombotic drugs to prevent arterial thrombosis during PAI. When compared with varying results regarding the use of heparin in the United Kingdom, the variety in the Netherlands showed a different pattern. The proven variety in these countries, and also between these countries, emphasises the need for authoritative studies to develop evidence-based practical guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiological Diagnosis and Management of Epistaxis

The majority of episodes of spontaneous posterior epistaxis treated with embolisation are idiopathic in nature. The angiographic findings are typically normal. Specific angiographic signs are rare and may include the following: a tumour blush, telangiectasia, aneurysm, and/or extravasation. Selective internal carotid artery (ICA) angiography may show rare causes of epistaxis, such as traumatic or mycotic aneurysms, which require different treatment approaches. Complete bilateral selective external and internal carotid angiograms are essential to evaluation. The images should be analysed for detection of central retinal blush in the external carotid artery (ECA) and anastomoses between the branches of the ECA and ICA. Monocular blindness and stroke are two of the most severe complications. Embolisation aims to decrease flow to the bleeding nasal mucosa while avoiding necrosis of the nasal skin and palate mucosa. Embolisation is routinely performed with a microcatheter positioned in the internal maxillary artery distal to the origin of the meningeal arteries. A guiding catheter should be placed in the proximal portion of the ECA to avoid vasospasm. Embolisation with microparticles is halted when the peripheral branches of the sphenopalatine artery are occluded. The use of coils is not recommended because recurrent epistaxis may occur due to proximal embolization; moreover, the option of repeat distal embolisation is lost. The success rate of embolisation therapy (accounting for late recurrence of bleeding) varies between 71 and 94 %. Results from endoscopic surgery are quite comparable. When epistaxis is refractory to nasal packing or endoscopic surgery, embolisation is the treatment of choice in some centres.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Double Coaxial Microcatheter Technique for Glue Embolization of Renal Arteriovenous Malformations

PurposeTo demonstrate the technical benefit of the double coaxial microcatheter technique for embolization of renal arteriovenous malformations (AVMs) with n-butyl cyanoacrylate and iodized oil (glue).Materials and MethodsSix consecutive patients (1 man and 5 women; mean age 61 years; range 44–77 years) with renal AVMs were included. Five patients had hematuria, and one had a risk of heart failure due to a large intrarenal arteriovenous shunt. All patients underwent transarterial embolization using glue and the double coaxial microcatheter technique with outer 2.6F and inner 1.9F microcatheters. After glue injection, the inner microcatheter was retracted, while the outer microcatheter was retained. We assessed the complications and clinical outcomes of this technique.ResultsTechnical success was achieved in all patients. In 9 sessions, 34 feeding arteries were embolized with glue using the double coaxial microcatheter technique, 1 was embolized with glue using a single microcatheter, and 2 were embolized with coils. The double coaxial microcatheter technique was useful for selecting small tortuous feeding arteries, preventing glue reflux to the proximal arteries, and approaching multiple feeding arteries without complete retraction of the microcatheters. As a minor complication, glue migrated into the venous system in four patients without any sequelae. In all patients, favorable clinical outcomes, including hematuria cessation in five patients and improvement of the large intrarenal arteriovenous shunt in one patient, were obtained without deterioration of renal function.ConclusionGlue embolization with the double coaxial microcatheter technique was useful for treating renal AVMs with multiple tortuous feeding arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pharmacokinetic Evaluation of Two Paclitaxel-Coated Balloons with Different Drug Load in a Short-Term Porcine Study

PurposeThe aim of the study was to evaluate the pharmacokinetics and tissue absorption of 2 paclitaxel (PTX) drug-coated balloons (DCB) using different drug loads in a porcine-injured iliac artery model.Materials and MethodsTwenty-eight pigs were randomized into 2 groups. In group B1, angioplasty was performed with a 1.0 µg/mm{sup 2} DCB with PTX and in group B3, with a 3.0 µg/mm{sup 2} DCB with PTX. An overstretched model of the iliac artery was used for angioplasty under fluoroscopy. Blood and vessel wall PTX were measured with liquid-chromatography mass spectrometry at 1, 5, 30 min, 1, 7, and 28 days. Remaining drug in the balloon was analyzed.ResultsMean PTX in blood was significantly higher in the group B3 0.269 ± 0.085 µg/ml compared with the B1 0.218 ± 0.085 µg/ml; p = 0.01. Peak blood PTX concentration was detected at 1 min, and PTX was undetectable 24 h post-angioplasty. There were no statistically significant differences in the mean arterial wall concentration from the treated iliac artery between group-B1 (15.24 ± 21.29 ng/mg) and B3 (15.68 ± 16.33 ng/mg), or in the PTX wall concentration measured at different time points. Mean remaining drug in assayed balloons was lower for group-B1 and represented 8 % of the initial dose.ConclusionsBlood PTX was higher when using 3.0 µg/mm{sup 2} DCB, with a peak drug concentration at 1-min, although the drug was undetectable at 24 h, independently of the loading dose. This study demonstrates no difference in arterial wall uptake of a low dose DCB (1.0 µg/mm{sup 2}), when compared to a common dose DCB (3.0 µg/mm{sup 2}) suggesting that the dose of drug in the DCB could be reduced obtaining a similar clinical effect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superparamagnetic iron oxide polyacrylic acid coated γ-Fe{sub 2}O{sub 3} nanoparticles do not affect kidney function but cause acute effect on the cardiovascular function in healthy mice

This study describes the distribution of intravenously injected polyacrylic acid (PAA) coated γ-Fe{sub 2}O{sub 3} NPs (10 mg kg{sup −1}) at the organ, cellular and subcellular levels in healthy BALB/cJ mice and in parallel addresses the effects of NP injection on kidney function, blood pressure and vascular contractility. Magnetic resonance imaging (MRI) and transmission electron microscopy (TEM) showed accumulation of NPs in the liver within 1 h after intravenous infusion, accommodated by intracellular uptake in endothelial and Kupffer cells with subsequent intracellular uptake in renal cells, particularly the cytoplasm of the proximal tubule, in podocytes and mesangial cells. The renofunctional effects of NPs were evaluated by arterial acid–base status and measurements of glomerular filtration rate (GFR) after instrumentation with chronically indwelling catheters. Arterial pH was 7.46 ± 0.02 and 7.41 ± 0.02 in mice 0.5 h after injections of saline or NP, and did not change over the next 12 h. In addition, the injections of NP did not affect arterial PCO{sub 2} or [HCO{sub 3}{sup −}] either. Twenty-four and 96 h after NP injections, the GFR averaged 0.35 ± 0.04 and 0.35 ± 0.01 ml min{sup −1} g{sup −1}, respectively, values which were statistically comparable with controls (0.29 ± 0.02 and 0.33 ± 0.1 ml{sup –1} min{sup –1} 25 g{sup –1}). Mean arterial blood pressure (MAP) decreased 12–24 h after NP injections (111.1 ± 11.5 vs 123.0 ± 6.1 min{sup −1}) associated with a decreased contractility of small mesenteric arteries revealed by myography to characterize endothelial function. In conclusion, our study demonstrates that accumulation of superparamagnetic iron oxide nanoparticles does not affect kidney function in healthy mice but temporarily decreases blood pressure. -- Highlights: ► PAA coated γ-Fe{sub 2}O{sub 3} nanoparticles were injected intravenously into healthy mice. ► We examine the distribution and physiological effects of nanoparticle accumulation. ► No effects of accumulation in kidney on acid-base status or GFR. ► Acute hypotension associated with decreased contractility of small vessels. ► We demonstrate physiological effects of PAA γ-Fe{sub 2}O{sub 3} NP for medical purposes.

60 APPLIED LIFE SCIENCES↗

Developing Novel Performance Measures for Traffic Congestion Management and Operational Planning Based on Connected Vehicle Data

In this study, the authors present their efforts in exploring a new type of traffic data, referred to as internet-connected vehicle (ICV) data, for traffic congestion management and operational planning. Most currently manufactured vehicles contain onboard GPS and cellular modules, and they constantly connect to automobile manufacturers' clouds via cellular networks and upload their status. Some automobile manufacturers have recently redistributed the nonpersonal part of such data, such as geolocation, to third-party organizations for innovative applications. Compared with the traditional vehicle GPS data, the ICV data contain high-resolution GPS waypoints accompanied with the vehicles' abnormal moving events (e.g., hard braking). The ICV data also have huge potential in congestion management and operational planning. They explore to identify and analyze traffic congestion on both freeways and arterials using the ICV data. The ICV data adopted for this research are redistributed by Wejo Data Service, representing 10%-15% of all moving vehicles in the Dallas-Fort Worth (DFW) area in Texas. Through one case study for a freeway segment and one for an arterial segment, new traffic performance metrics based on the characteristics of ICV data have been presented. The highlights of these efforts are as follows: (I) queue length and propagation at freeway bottlenecks can be directly measured based on where and when most internet-connected vehicles slow down and join the queue; (II) an internet-connected vehicle's actual delay time on arterials can be directly measured according to its slow movement percentage, without assuming the nondelay travel speed; and (III) the ICV data set are also combined with the high-resolution traffic signal events to generate a ground-truth time-space diagram (TSD) on arterials - a common visualization of arterial signal performance for transportation planning and operations.

33 ADVANCED PROPULSION SYSTEMS↗

Automatic multiscale enhancement and segmentation of pulmonary vessels in CT pulmonary angiography images for CAD applications

The authors are developing a computerized pulmonary vessel segmentation method for a computer-aided pulmonary embolism (PE) detection system on computed tomographic pulmonary angiography (CTPA) images. Because PE only occurs inside pulmonary arteries, an automatic and accurate segmentation of the pulmonary vessels in 3D CTPA images is an essential step for the PE CAD system. To segment the pulmonary vessels within the lung, the lung regions are first extracted using expectation-maximization (EM) analysis and morphological operations. The authors developed a 3D multiscale filtering technique to enhance the pulmonary vascular structures based on the analysis of eigenvalues of the Hessian matrix at multiple scales. A new response function of the filter was designed to enhance all vascular structures including the vessel bifurcations and suppress nonvessel structures such as the lymphoid tissues surrounding the vessels. An EM estimation is then used to segment the vascular structures by extracting the high response voxels at each scale. The vessel tree is finally reconstructed by integrating the segmented vessels at all scales based on a 'connected component' analysis. Two CTPA cases containing PEs were used to evaluate the performance of the system. One of these two cases also contained pleural effusion disease. Two experienced thoracic radiologists provided the gold standard of pulmonary vessels including both arteries and veins by manually tracking the arterial tree and marking the center of the vessels using a computer graphical user interface. The accuracy of vessel tree segmentation was evaluated by the percentage of the 'gold standard' vessel center points overlapping with the segmented vessels. The results show that 96.2% (2398/2494) and 96.3% (1910/1984) of the manually marked center points in the arteries overlapped with segmented vessels for the case without and with other lung diseases. For the manually marked center points in all vessels including arteries and veins, the segmentation accuracy are 97.0% (4546/4689) and 93.8% (4439/4732) for the cases without and with other lung diseases, respectively. Because of the lack of ground truth for the vessels, in addition to quantitative evaluation of the vessel segmentation performance, visual inspection was conducted to evaluate the segmentation. The results demonstrate that vessel segmentation using our method can extract the pulmonary vessels accurately and is not degraded by PE occlusion to the vessels in these test cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-170: Characterization of the Location, Extent, and Proximity to Critical Structures of Target Volumes Provides Detail for Improved Outcome Predictions Among Pancreatic Cancer Patients

Purpose: In radiotherapy, size, location and proximity of the target to critical structures influence treatment decisions. It has been shown that proximity of the target predicts dosimetric sparing of critical structures. In addition to dosimetry, precise location of disease has further implications such as tumor invasion, or proximity to major arteries that inhibit surgery. Knowledge of which patients can be converted to surgical candidates by radiation may have high impact on future treat/no-treat decisions. We propose a method to improve our characterization of the location of pancreatic cancer and treatment volume extent with respect to nearby arteries with the goal of developing features to improve clinical predictions and decisions. Methods: Oncospace is a local learning health system that systematically captures clinical outcomes and all aspects of radiotherapy treatment plans, including overlap volume histograms (OVH) – a measure of spatial relationships between two structures. Minimum and maximum distances of PTV and OARs based on OVH, PTV volume, anatomic location by ICD-9 code, and surgical outcome were queried. Normalized distance to center from the left and right kidney was calculated to indicate tumor location and laterality. Distance to critical arteries (celiac, superior mesenteric, common hepatic) is validated by surgical status (borderline resectable, locally advanced converted to resectable). Results: There were 205 pancreas stereotactic body radiotherapy patients treated from 2009–2015 queried. Location/laterality of tumor based on kidney OVH show strong trends between location by OVH and by ICD-9. Compared to the locally advanced group, the borderline resectable group showed larger geometrical distance from critical arteries (p=0.03). Conclusion: Our platform enabled analysis of shape/size-location relationships. These data suggest that PTV volume and attention to distance between PTVs and surrounding OARs and major arteries may be promising for improving characterization of treatment anatomy that can refine our ability for outcome predictions and decision making. Elekta, Toshiba.

60 APPLIED LIFE SCIENCES↗