Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AGE ESTIMATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

PROPERTIES OF THE NEARBY BROWN DWARF WISEP J180026.60+013453.1

We present new spectroscopy and astrometry to characterize the nearby brown dwarf WISEP J180026.60+013453.1. The optical spectral type, L7.5, is in agreement with the previously reported near-infrared spectral type. The preliminary trigonometric parallax places it at a distance of 8.01 ± 0.21 pc, confirming that it is the fourth closest known late-L (L7–L9) dwarf. The measured luminosity, our detection of lithium, and the lack of low surface gravity indicators indicates that WISEP J180026.60+013453.1 has a mass 0.03 < M < 0.06 M{sub ⊙} and an age between 300 million and 1.5 billion years according to theoretical substellar evolution models. The low space motion is consistent with this young age. We have measured the rotational broadening (v sin i = 13.5 ± 0.5 km s{sup −1}), and use it to estimate a maximum rotation period of 9.3 hr.

79 ASTRONOMY AND ASTROPHYSICS↗

A DEDICATED CHANDRA ACIS OBSERVATION OF THE CENTRAL COMPACT OBJECT IN THE CASSIOPEIA A SUPERNOVA REMNANT

We present results of a recent Chandra X-ray Observatory observation of the central compact object (CCO) in the supernova remnant (SNR) Cassiopeia A. This observation was carried out in an instrumental configuration that combines a high spatial resolution with a minimum spectral distortion, and it allowed us to search for pulsations with periods longer than {approx}0.68 s. We found no evidence of extended emission associated with the CCO, nor statistically significant pulsations (the 3{sigma} upper limit on pulsed fraction is about 16%). The fits of the CCO spectrum with the power-law model yield a large photon index, {Gamma} {approx} 5, and a hydrogen column density larger than that obtained from the SNR spectra. The fits with the blackbody model are statistically unacceptable. Better fits are provided by hydrogen neutron star atmosphere models, with the best-fit effective temperature kT{sup {infinity}}{sub eff} {approx} 0.2 keV, but they require a small star's radius, R = 4-5.5 km, and a low mass, M {approx}< 0.8 M{sub sun}. A neutron star cannot have so small radius and mass, but the observed emission might emerge from an atmosphere of a strange quark star. More likely, the CCO could be a neutron star with a nonuniform surface temperature and a low surface magnetic field (the so-called anti-magnetar), similar to three other CCOs for which upper limits on period derivative have been established. The bolometric luminosity, L{sup {infinity}}{sub bol} {approx} 6 x 10{sup 33} erg s{sup -1}, estimated from the fits with the hydrogen atmosphere models is consistent with the standard neutron star cooling for the CCO age of 330 yr. The origin of the surface temperature's nonuniformity remains to be understood; it might be caused by anisotropic heat conduction in the neutron star crust with very strong toroidal magnetic fields.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE EXISTENCE OF A DISTANT SOLAR COMPANION AND ITS POSSIBLE EFFECTS ON THE OORT CLOUD AND THE OBSERVED COMET POPULATION

We analyze the possible existence and detection of a distant massive solar companion. Such an object-if it exists-should be very faint in the visible, so its direct detection might depend on current or future infrared sky surveys, like WISE. Alternatively, its presence could be uncovered through its perturbing effects on nearby objects such as, for instance, Oort Cloud comets (OCCs). We then estimate how putative solar companions of different masses and semimajor axes can perturb nearby OCCs causing an enhancement of the comet flux along the companion's path. We find that a companion of 5 Jupiter masses (M{sub J} ) can produce a signature detectable with the current record of observed new comets, provided that the Oort Cloud contains a dense inner core of comets and that the distance of the perturber is smaller than {approx}2 x 10{sup 4} AU. A 1 M{sub J} perturber can produce a signature detectable in the current record only if its distance were smaller than {approx}(2-3) x 10{sup 3} AU. The sample of discovered new comets is found to be two orders of magnitude too small to show a signature caused by a Neptune-mass companion at any distance above {approx}10{sup 3} AU to a significant level. We also estimate that the Oort Cloud will withstand the steady perturbing effects by a massive solar companion over the solar system age, with only a minor erosion, unless the companion had a mass {approx}>a few M{sub J} , and were at a distance {approx}<a few 10{sup 3} AU.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-I-54: Effective Dose and Radiation Cancer Risks for Scoliosis Patients Undergoing Full Spine Radiography

Purpose: Scoliotic patients underwent a lot of radiologic examinations during the control and treatment periods. This study used the PCXMC program to calculate the effective dose of the patients and assess the radiation cancer risks. Methods: Seventy five scoliotic patients were examined using CR or DR systems during the control and treatment periods in Chang Gung Memorial Hospital. The technical factors were recorded for each patient during his/her control and treatment period. The entrance surface dose was measured using thermoluminence dosimeters and derived from technical factors and irradiated geometry. The effective dose of patients and relative radiation cancer risks were calculated by the PCXMC program. All required information regarding patient age and sex, the x-ray spectra, and the tube voltage and current were registered. The radiation risk were estimated using the model developed by the BEIR VII committee (2006). Results: The effective doses of full spine radiography with anteroposterior and lateral projections were 0.626 mSv for patients using DR systems, and 0.483mSv for patients using CR systems, respectively. The dose using DR system was 29.6% higher than those using CR system. The maximum organ dose was observed in the breast for both projections in all the systems. The risk of exposure—induced cancer death (REID) of patients for DR and CR systems were 0.009% and 0.007%, respectively. Conclusion: The risk estimates were regarded with healthy skepticism, placed more emphasis on the magnitude of the risk. The effective doses estimated in this study could be served as a reference for radiologists and technologists and demonstrate the necessity to optimize patient protection for full spine radiography though the effective doses are not at the level to induce deterministic effects and not significant in the stochastic effect. This study was supported by the grants from the Chang Gung Memorial Hospital (CMRPD1D0421)

60 APPLIED LIFE SCIENCES↗

Development and Validation of a Lifecycle-based Prognostics Architecture with Test Bed Validation

On-line monitoring and tracking of nuclear plant system and component degradation is being investigated as a method for improving the safety, reliability, and maintainability of aging nuclear power plants. Accurate prediction of the current degradation state of system components and structures is important for accurate estimates of their remaining useful life (RUL). The correct quantification and propagation of both the measurement uncertainty and model uncertainty is necessary for quantifying the uncertainty of the RUL prediction. This research project developed and validated methods to perform RUL estimation throughout the lifecycle of plant components. Prognostic methods should seamlessly operate from beginning of component life (BOL) to end of component life (EOL). We term this "Lifecycle Prognostics." When a component is put into use, the only information available may be past failure times of similar components used in similar conditions, and the predicted failure distribution can be estimated with reliability methods such as Weibull Analysis (Type I Prognostics). As the component operates, it begins to degrade and consume its available life. This life consumption may be a function of system stresses, and the failure distribution should be updated to account for the system operational stress levels (Type II Prognostics). When degradation becomes apparent, this information can be used to again improve the RUL estimate (Type III Prognostics). This research focused on developing prognostics algorithms for the three types of prognostics, developing uncertainty quantification methods for each of the algorithms, and, most importantly, developing a framework using Bayesian methods to transition between prognostic model types and update failure distribution estimates as new information becomes available. The developed methods were then validated on a range of accelerated degradation test beds. The ultimate goal of prognostics is to provide an accurate assessment for RUL predictions, with as little uncertainty as possible. From a reliability and maintenance standpoint, there would be improved safety by avoiding all failures. Calculated risk would decrease, saving money by avoiding unnecessary maintenance. One major bottleneck for data-driven prognostics is the availability of run-to-failure degradation data. Without enough degradation data leading to failure, prognostic models can yield RUL distributions with large uncertainty or mathematically unsound predictions. To address these issues a "Lifecycle Prognostics" method was developed to create RUL distributions from Beginning of Life (BOL) to End of Life (EOL). This employs established Type I, II, and III prognostic methods, and Bayesian transitioning between each Type. Bayesian methods, as opposed to classical frequency statistics, show how an expected value, a priori, changes with new data to form a posterior distribution. For example, when you purchase a component you have a prior belief, or estimation, of how long it will operate before failing. As you operate it, you may collect information related to its condition that will allow you to update your estimated failure time. Bayesian methods are best used when limited data are available. The use of a prior also means that information is conserved when new data are available. The weightings of the prior belief and information contained in the sampled data are dependent on the variance (uncertainty) of the prior, the variance (uncertainty) of the data, and the amount of measured data (number of samples). If the variance of the prior is small compared to the uncertainty of the data, the prior will be weighed more heavily. However, as more data are collected, the data will be weighted more heavily and will eventually swamp out the prior in calculating the posterior distribution of model parameters. Fundamentally Bayesian analysis updates a prior belief with new data to get a posterior belief. The general approach to applying the Bayesian method to lifecycle prognostics consisted of identifying the prior, which is the RUL estimate and uncertainty from the previous prognostics type, and combining it with observational data related to the newer prognostics type. The resulting lifecycle prognostics algorithm uses all available information throughout the component lifecycle.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dworshak Kokanee Population and Engrainment Assessment : 2006 Annual Report, March 1, 2006 - February 28, 2007.

During this contract, we continued testing underwater strobe lights to determine their effectiveness at repelling kokanee Oncorhynchus nerka away from Dworshak Dam. Strobe light tests were conducted on four nights from April 24-27, 2006, in front of the middle reservoir outlet (RO) 2. The density and distribution of fish, (thought to be mostly kokanee), were monitored with a split-beam echo sounder. We then compared fish counts and densities during nights when the lights were flashing to counts and densities during adjacent nights without the lights on. On two nights, April 25 and 27, 2006, when no lights were present, fish counts near RO 2 averaged 12.4 fish and densities averaged 31.0 fish/ha. When strobe lights were turned on during the nights of April 24 and 26, mean counts dropped to 4.7 fish and densities dropped to 0.5 fish/ha. The decline in counts (62%) and densities (99%) was statistically significant (p = 0.009 and 0.002, respectively). Test results indicated that strobe lights were able to reduce fish densities by at least 50% in front of a discharging reservoir outlet, which would be sufficient to improve sport fish harvest. We also used split-beam hydroacoustics to monitor the kokanee population in Dworshak Reservoir during 2006. Estimated abundance of kokanee increased from the 2005 population estimate. Based on hydroacoustic surveys, we estimated approximately 5,815,000 kokanee (90% CI {+-} 27.6%) in Dworshak Reservoir in August 2006. This included 2,183,000 age-0 (90% CI {+-} 24.2%), 1,509,000 age-1 (90% CI {+-} 29.0%), and 2,124,000 age-2 (90% CI {+-} 27.6%) kokanee. This resulted in a density of age-2 kokanee above the management goal of 30-50 adults/ha. Entrainment sampling was conducted with fixed-site, split-beam hydroacoustics from May through September for a continuous 24 h period when dam operations permitted. The highest fish detection rates from entrainment assessments were found during dawn periods, unlike previous year's results, which were highest during nighttime. The lowest detection rate was found during the day period, which was consistent with previous findings. Fish detection rates were generally low during high discharges throughout the summer and highest during low discharges in May and June. Low detection rates were found during high discharge periods during drawdowns for anadromous fish flows in July and August, which resulted in low susceptibility to entrainment. Counts of spawning kokanee in four tributary streams totaled 29,743 fish. These data fit the previously developed relationship between spawner counts and adult kokanee abundance in the reservoir.

13 HYDRO ENERGY↗

The 2006 Project Progress Report for 1987-099-00 Dworshak Kokanee Population and Entrainment Assessment (contract # 26850) is attached to project 2007-003-00, contract #31598. [POINTER]

During this contract, we continued testing underwater strobe lights to determine their effectiveness at repelling kokanee Oncorhynchus nerka away from Dworshak Dam. Strobe light tests were conducted on four nights from April 24-27, 2006, in front of the middle reservoir outlet (RO) 2. The density and distribution of fish, (thought to be mostly kokanee), were monitored with a split-beam echo sounder. We then compared fish counts and densities during nights when the lights were flashing to counts and densities during adjacent nights without the lights on. On two nights, April 25 and 27, 2006, when no lights were present, fish counts near RO 2 averaged 12.4 fish and densities averaged 31.0 fish/ha. When strobe lights were turned on during the nights of April 24 and 26, mean counts dropped to 4.7 fish and densities dropped to 0.5 fish/ha. The decline in counts (62%) and densities (99%) was statistically significant (p = 0.009 and 0.002, respectively). Test results indicated that strobe lights were able to reduce fish densities by at least 50% in front of a discharging reservoir outlet, which would be sufficient to improve sport fish harvest. We also used split-beam hydroacoustics to monitor the kokanee population in Dworshak Reservoir during 2006. Estimated abundance of kokanee increased from the 2005 population estimate. Based on hydroacoustic surveys, we estimated approximately 5,815,000 kokanee (90% CI {+-} 27.6%) in Dworshak Reservoir in August 2006. This included 2,183,000 age-0 (90% CI {+-} 24.2%), 1,509,000 age-1 (90% CI {+-} 29.0%), and 2,124,000 age-2 (90% CI {+-} 27.6%) kokanee. This resulted in a density of age-2 kokanee above the management goal of 30-50 adults/ha. Entrainment sampling was conducted with fixed-site, split-beam hydroacoustics from May through September for a continuous 24 h period when dam operations permitted. The highest fish detection rates from entrainment assessments were found during dawn periods, unlike previous year's results, which were highest during nighttime. The lowest detection rate was found during the day period, which was consistent with previous findings. Fish detection rates were generally low during high discharges throughout the summer and highest during low discharges in May and June. Low detection rates were found during high discharge periods during drawdowns for anadromous fish flows in July and August, which resulted in low susceptibility to entrainment. Counts of spawning kokanee in four tributary streams totaled 29,743 fish. These data fit the previously developed relationship between spawner counts and adult kokanee abundance in the reservoir.

13 HYDRO ENERGY↗

The Next Generation Virgo Cluster Survey. XXVIII. Characterization of the Galactic White Dwarf Population

We use three different techniques to identify hundreds of white dwarf (WD) candidates in the Next Generation Virgo Cluster Survey (NGVS) based on photometry from the NGVS and GUViCS, and proper motions derived from the NGVS and the Sloan Digital Sky Survey (SDSS). Photometric distances for these candidates are calculated using theoretical color–absolute magnitude relations, while effective temperatures are measured by fitting their spectral energy distributions. Disk and halo WD candidates are separated using a tangential velocity cut of 200 km s{sup −1} in a reduced proper motion diagram, which leads to a sample of six halo WD candidates. Cooling ages, calculated for an assumed WD mass of 0.6 M {sub ⊙}, range between 60 Myr and 6 Gyr, although these estimates depend sensitively on the adopted mass. Luminosity functions for the disk and halo subsamples are constructed and compared to previous results from the SDSS and SuperCOSMOS survey. We compute a number density of (2.81 ± 0.52) × 10{sup −3} pc{sup −3} for the disk WD population—consistent with previous measurements. We find (7.85 ± 4.55) × 10{sup −6} pc{sup −3} for the halo, or 0.3% of the disk. Observed stellar counts are also compared to predictions made by the TRILEGAL and Besançon stellar population synthesis models. The comparison suggests that the TRILEGAL model overpredicts the total number of WDs. The WD counts predicted by the Besançon model agree with the observations, although a discrepancy arises when comparing the predicted and observed halo WD populations; the difference is likely due to the WD masses in the adopted model halo.

79 ASTRONOMY AND ASTROPHYSICS↗

Prognostication of LED Remaining Useful Life and Color Stability in the Presence of Contamination

The reliability of LED products may be affected by both luminous flux drop and color shift. Previous research on the topic focuses on either luminous maintenance or color shift. However, luminous flux degradation usually takes very long time to observe in LEDs under normal operating conditions. In this paper, the impact of a VOC (volatile organic compound) contaminated luminous flux and color stability are examined. As a result, both luminous degradation and color shift had been recorded in a short time. Test samples are white, phosphorconverted, high-power LED packages. Absolute radiant flux is measured with integrating sphere system to calculate the luminous flux. Luminous flux degradation and color shift distance were plotted versus aging time to show the degradation pattern. A prognostic health management (PHM) method based on the state variables and state estimator have been proposed in this paper. In this PHM framework, unscented kalman filter (UKF) was deployed as the carrier of all states. During the estimation process, third order dynamic transfer function was used to implement the PHM framework. Both of the luminous flux and color shift distance have been used as the state variable with the same PHM framework to exam the robustness of the method. Predicted remaining useful life is calculated at every measurement point to compare with the tested remaining useful life. The result shows that state estimator can be used as the method for the PHM of LED degradation with respect to both luminous flux and color shift distance. The prediction of remaining useful life of LED package, made by the states estimator and data driven approach, falls in the acceptable errorbounds (20%) after a short training of the estimator.

Lall, Pradeep↗

Prognostics Health Management Model for LED Package Failure Under Contaminated Environment

The reliability consideration of LED products includes both luminous flux drop and color shift. Previous research either talks about luminous maintenance or color shift, because luminous flux degradation usually takes very long time to observe. In this paper, the impact of a VOC (volatile organic compound) contaminated luminous flux and color stability are examined. As a result, both luminous degradation and color shift had been recorded in a short time. Test samples are white, phosphor-converted, high-power LED packages. Absolute radiant flux is measured with integrating sphere system to calculate the luminous flux. Luminous flux degradation and color shift distance were plotted versus aging time to show the degradation pattern. A prognostic health management (PHM) method based on the state variables and state estimator have been proposed in this paper. In this PHM framework, unscented kalman filter (UKF) was deployed as the carrier of all states. During the estimation process, third order dynamic transfer function was used to implement the PHM framework. Both of the luminous flux and color shift distance have been used as the state variable with the same PHM framework to exam the robustness of the method. Predicted remaining useful life is calculated at every measurement point to compare with the tested remaining useful life. The result shows that state estimator can be used as the method for the PHM of LED degradation with respect to both luminous flux and color shift distance. The prediction of remaining useful life of LED package, made by the states estimator and data driven approach, falls in the acceptable error-bounds (20%) after a short training of the estimator.

Lall, Pradeep↗

Joint Estimation of Cardiac Toxicity and Recurrence Risks After Comprehensive Nodal Photon Versus Proton Therapy for Breast Cancer

Purpose: The study aims to perform joint estimation of the risk of recurrence caused by inadequate radiation dose coverage of lymph node targets and the risk of cardiac toxicity caused by radiation exposure to the heart. Delivered photon plans are compared with realistic proton plans, thereby providing evidence-based estimates of the heterogeneity of treatment effects in consecutive cases for the 2 radiation treatment modalities. Methods and Materials: Forty-one patients referred for postlumpectomy comprehensive nodal photon irradiation for left-sided breast cancer were included. Comparative proton plans were optimized by a spot scanning technique with single-field optimization from 2 en face beams. Cardiotoxicity risk was estimated with the model of Darby et al, and risk of recurrence following a compromise of lymph node coverage was estimated by a linear dose-response model fitted to the recurrence data from the recently published EORTC (European Organisation for Research and Treatment of Cancer) 22922/10925 and NCIC-CTG (National Cancer Institute of Canada Clinical Trials Group) MA.20 randomized controlled trials. Results: Excess absolute risk of cardiac morbidity was small with photon therapy at an attained age of 80 years, with median values of 1.0% (range, 0.2%-2.9%) and 0.5% (range, 0.03%-1.0%) with and without cardiac risk factors, respectively, but even lower with proton therapy (0.13% [range, 0.02%-0.5%] and 0.06% [range, 0.004%-0.3%], respectively). The median estimated excess absolute risk of breast cancer recurrence after 10 years was 0.10% (range, 0.0%-0.9%) with photons and 0.02% (range, 0.0%-0.07%) with protons. The association between age of the patient and benefit from proton therapy was weak, almost non-existing (Spearman rank correlations of −0.15 and −0.30 with and without cardiac risk factors, respectively). Conclusions: Modern photon therapy yields limited risk of cardiac toxicity in most patients, but proton therapy can reduce the predicted risk of cardiac toxicity by up to 2.9% and the risk of breast cancer recurrence by 0.9% in individual patients. Predicted benefit correlates weakly with age. Combined assessment of the risk from cardiac exposure and inadequate target coverage is desirable for rational consideration of competing photon and proton therapy plans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Activities in Support of Continuing the Service of Nuclear Power Plant Safety-Related Concrete Structures

Nuclear power plant concrete structures are described. In-service inspection and testing requirements in the U.S. are summarized. The license renewal process in the U.S. is outlined and its current status provided. Operating experience related to performance of the concrete structures is presented. Basic components of a program to manage aging of the concrete structures are identified and described: degradation mechanisms, damage models, and material performance; assessment and remediation (i.e., component selection, in-service inspection, non-destructive examinations, and remedial actions); and estimation of performance at present or some future point in time (i.e., application of structural reliability theory to the design and optimization of in-service inspection/maintenance strategies, and determination of the effects of degradation on plant risk). Finally, areas are noted where additional research would be of benefit to aging management of nuclear power plant concrete structures.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Nonbreast Second Malignancies After Treatment of Primary Breast Cancer

Purpose: To determine the incidence and risk factors for nonbreast second malignancies (NBSMs) in women after treatment for primary breast cancer. Methods and Materials: Between January 1985 and December 1995, a total of 1,084 breast cancer patients were analyzed for NBSMs. Detailed analysis was carried out for age, family history, disease stage, radiation therapy, chemotherapy, hormone therapy, other clinical/pathologic characteristics, and site of NBSMs. The Cox proportional hazard regression model was used to estimate the relative risk of NBSMs. Results: Median follow-up was 12 years. In total, 33 cases of NBSMs were noted in 29 patients. The overall incidence of NBSM was 3%, and the median time for NBSMs was 7 years. The most common NBSMs were gynecologic (22 patients), gastrointestinal (4 patients), head and neck (3 patients), hematologic (2 patients), lung (1 patient), and thyroid (1 patient). The NBSMs rate at 12 years was 2.4% for both mastectomy and radiation therapy groups. In the subset of patients less than 45 years of age at the time of treatment, the NBSMs rate was 0.7% as compared with 4.6% in patients more than 45 years of age (p = 0.001). Statistically significant higher incidences of endometrial and ovarian cancer were seen in patients with hormonal therapy (5.2%) as compared with patients without hormonal therapy (1.8%, p = 0.002). Women with a family history of breast cancer had a higher incidence (6%) of endometrial and ovarian malignancy compared with women without such a history (2.1%, p = 0.003). Chemotherapy did not affect the risk of second malignancy. Conclusion: The most common NBSMs in this study were gynecologic. Family history of breast cancer was a high risk factor for NBSMs. No risk of NBSMs with radiotherapy was observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstruction of radionuclide intakes for the residents of East Urals Radioactive Trace (1957–2011)

The East Urals Radioactive Trace (EURT) was formed after a chemical explosion in the radioactive waste-storage facility of the Mayak Production Association in 1957 (Southern Urals, Russia) and resulted in an activity dispersion of 7.4 × 10 16 Bq into the atmosphere. Internal exposure due to ingestion of radionuclides with local foodstuffs was the main factor of public exposure at the EURT. The EURT cohort, combining residents of most contaminated settlements, was formed for epidemiological study at the Urals Research Center for Radiation Medicine, Russia (URCRM). For the purpose of improvement of radionuclide intake estimates for cohort members, the following data sets collected in URCRM were used: (1) Total β-activity and radiochemical measurements of 90 Sr in local foodstuffs over all of the period of interest (1958–2011; n = 2200), which were used for relative 90 Sr intake estimations. (2) 90 Sr measurements in human bones and whole body ( n = 338); these data were used for average 90 Sr intake derivations using an age- and gender-dependent Sr-biokinetic model. Non-strontium radionuclide intakes were evaluated on the basis of 90 Sr intake data and the radionuclide composition of contaminated foodstuffs. Validation of radionuclide intakes during the first years after the accident was first carried out using measurements of the feces β-activity of EURT residents ( n = 148). The comparison of experimental and reconstructed values of feces β-activity shows good agreement. 90 Sr intakes for residents of settlements evacuated 7–14 days after the accident were also obtained from 90 Sr measurements in human bone and whole body. Furthermore, the results of radionuclide intake reconstruction will be used to estimate the internal doses for the members of the EURT cohort.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Spatial Estimation of Populations at Risk from Radiological Dispersion Device Terrorism Incidents

Delineation of the location and size of the population potentially at risk of exposure to ionizing radiation is one of the key analytical challenges in estimating accurately the severity of the potential health effects associated with a radiological terrorism incident. Regardless of spatial scale, the geographical units for which population data commonly are collected rarely coincide with the geographical scale necessary for effective incident management and medical response. This paper identifies major government and commercial open sources of U.S. population data and presents a GIS-based approach for allocating publicly available population data, including age distributions, to geographical units appropriate for planning and implementing incident management and medical response strategies. In summary: The gravity model offers a straight-forward, empirical tool for estimating population flows, especially when geographical areas are relatively well-defined in terms of accessibility and spatial separation. This is particularly important for several reasons. First, the spatial scale for the area impacted by a RDD terrorism event is unlikely to match fully the spatial scale of available population data. That is, the plume spread typically will not uniformly overlay the impacted area. Second, the number of people within the impacted area varies as a function whether an attack occurs during the day or night. For example, the population of a central business district or industrial area typically is larger during the day while predominately residential areas have larger night time populations. As a result, interpolation techniques that link population data to geographical units and allocate those data based on time-frame at a spatial scale that is relevant to enhancing preparedness and response. The gravity model's main advantage is that it efficiently allocates readily available, open source population data to geographical units appropriate for planning and implementing incident management and medical monitoring strategies. The importance of being able to link population estimates to geographic areas during the course of an RDD incident can be understood intuitively: - The spatial distribution of actual total dose equivalents of ionizing radiation is likely to vary due to changes in meteorological parameters as an event evolves over time; - The size of the geographical area affected also is likely to vary as a function of the actual release scenario; - The ability to identify the location and size of the populations that may be exposed to doses of ionizing radiation is critical to carrying out appropriate treatment and post-event medical monitoring; - Once a spatial interaction model has been validated for a city or a region, it can then be used for simulation and prediction purposes to assess the possible human health consequences of different release scenarios. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Association Between Geographic Access to Cancer Care and Receipt of Radiation Therapy for Rectal Cancer

Purpose: Trimodality therapy (chemoradiation and surgery) is the standard of care for stage II/III rectal cancer but nearly one third of patients do not receive radiation therapy (RT). We examined the relationship between the density of radiation oncologists and the travel distance to receipt of RT. Methods and Materials: A retrospective study based on the National Cancer Data Base identified 26,845 patients aged 18 to 80 years with stage II/III rectal cancer diagnosed from 2007 to 2010. Radiation oncologists were identified through the Physician Compare dataset. Generalized estimating equations clustering by hospital service area was used to examine the association between geographic access and receipt of RT, controlling for patient sociodemographic and clinical characteristics. Results: Of the 26,845 patients, 70% received RT within 180 days of diagnosis or within 90 days of surgery. Compared with a travel distance of <12.5 miles, patients diagnosed at a reporting facility who traveled ≥50 miles had a decreased likelihood of receipt of RT (50-249 miles, adjusted odds ratio 0.75, P<.001; ≥250 miles, adjusted odds ratio 0.46; P=.002), all else being equal. The density level of radiation oncologists was not significantly associated with the receipt of RT. Patients who were female, nonwhite, and aged ≥50 years and had comorbidities were less likely to receive RT (P<.05). Patients who were uninsured but self-paid for their medical services, initially diagnosed elsewhere but treated at a reporting facility, and resided in Midwest had an increased the likelihood of receipt of RT (P<.05). Conclusions: An increased travel burden was associated with a decreased likelihood of receiving RT for patients with stage II/III rectal cancer, all else being equal; however, radiation oncologist density was not. Further research of geographic access and establishing transportation assistance programs or lodging services for patients with an unmet need might help decrease geographic barriers and improve the quality of rectal cancer care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of absorption, retention and elimination of two different oral doses of vitamin A in Zambian boys using accelerator mass spectrometry

A recent survey indicated that high-dose vitamin A supplements (HD-VAS) had no apparent effect on vitamin A (VA) status of Zambian children <5 y of age. To explore possible reasons for the lack of response to HD-VAS among Zambian children, we quantified the absorption, retention, and urinary elimination of either a single HDVAS (60 mg) or a smaller dose of stable isotope (SI)-labeled VA (5 mg), which was used to estimate VA pool size, in 3-4 y old Zambian boys (n = 4 for each VA dose). A 25 nCi tracer dose of [{sup 14}C{sub 2}]-labeled VA was co-administered with the HD-VAS or SI-labeled VA, and 24-hr stool and urine samples were collected for 3 and 7 consecutive days, respectively, and 24-hr urine samples at 4 later time points. Accelerator Mass Spectrometry (AMS) was used to measure the cumulative excretion of {sup 14}C in stool and urine 3d after dosing to estimate, respectively, absorption and retention of the VAS and SI-labeled VA. The urinary elimination rate (UER) was estimated by plotting {sup 14}C in urine vs. time, and fitting an exponential equation to the data. Estimates of mean absorption, retention and the UER were 83.8 {+-} 7.1%, 76.3 {+-} 6.7%, and 1.9 {+-} 0.6%/d, respectively, for the HD-VAS and 76.5 {+-} 9.5%, 71.1 {+-} 9.4%, and 1.8 {+-} 1.2%/d, respectively for the smaller dose of SI-labeled VA. Estimates of absorption, retention and the UER did not differ by size of the VA dose administered (P=0.26, 0.40, 0.88, respectively). Estimated absorption and retention were negatively associated with reported fever (P=0.011) and malaria (P =0.010). HD-VAS and SI-labeled VA were adequately absorbed, retained and utilized in apparently healthy Zambian preschool-age boys, although absorption and retention may be affected by recent infections.

59 BASIC BIOLOGICAL SCIENCES↗

Disc dichotomy signature in the vertical distribution of [Mg/Fe] and the delayed gas infall scenario

Context. Analysis of the Apache Point Observatory Galactic Evolution Experiment project (APOGEE) data suggests the existence of a clear distinction between two sequences of disc stars in the [α/Fe] versus [Fe/H] abundance ratio space, known as the high- and low-α sequence, respectively. This dichotomy also emerges from an analysis of the vertical distribution of the [α/Fe] abundance ratio. Aims. We aim to test whether the revised two-infall chemical evolution models designed to reproduce the low- and high-α sequences in the [α/Fe] versus [Fe/H] ratios in the solar neighbourhood are also capable of predicting the disc bimodality observed in the vertical distribution of [Mg/Fe] in APOGEE DR16 data. Methods. Along with the chemical composition of the simple stellar populations born at different Galactic times predicted by our reference chemical evolution models in the solar vicinity, we provide their maximum vertical height above the Galactic plane |zmax| computed assuming the relation between the vertical action and stellar age in APOGEE thin-disc stars. Result. The vertical distribution of the [Mg/Fe] abundance ratio predicted by the reference chemical evolution models is in agreement with that observed when combining the APOGEE DR16 data (chemical abundances) with the astroNN catalogue (stellar ages, orbital parameters) for stars younger than 8 Gyr (only low-α sequence stars). Including the high-α disc component, the dichotomy in the vertical [Mg/Fe] abundance distribution is reproduced considering the observational cut in the Galactic height of |z|< 2 kpc. However, our model predicts an overly flat (almost constant) growth of the maximum vertical height |zmax| quantity as a function of [Mg/Fe] for high-α objects in contrast with the median values from APOGEE data. Possible explanations for such a tension are that: (i) the APOGEE sample with |z|< 2 kpc is more likely than ours to be contaminated by halo stars, causing the median values to be kinematically hotter, and (ii) external perturbations – such as minor mergers – that the Milky Way experienced in the past could have heated up the disc, and the heating of the orbits cannot be modeled by only scattering processes. Assuming a disc dissection based on chemistry for APOGEE-DR16 stars (|z|< 2 kpc), the observed |zmax| distributions for high-α and low-α sequences are in good agreement with our model predictions if we consider the errors in the vertical action estimates in the calculation. Moreover, a better agreement between predicted and observed stellar distributions at different Galactic vertical heights is achieved if asteroseismic ages are included as a constraint in the best-fit model calculations. Conclusions. The signature of a delayed gas infall episode, which gives rise to a hiatus in the star formation history of the Galaxy, are imprinted both in the [Mg/Fe] versus [Fe/H] relation and in vertical distribution of [Mg/Fe] abundances in the solar vicinity.

79 ASTRONOMY AND ASTROPHYSICS↗