Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “3D image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

High frequency (4th order) sequence stratigraphy of Early Miocene deltaic shorelines, offshore Texas and Louisiana

Well logs and 3D seismic reflection data are integrated to image Lower Miocene depocenters of the upper Texas and westernmost Louisiana coastal and offshore areas. Although previously interpreted at a large scale (3rd order cycles), the detailed stratigraphy and depositional history of the early Miocene succession has not been fully developed. The upper lower Miocene interval from Robulus L (MFS10) to Amphistegina B (MFS9) has been further subdivided into five 4th order cycles (each 200 to 300 m thick) to provide finer scale stratigraphic detail and interpretation of depositional environments. Results of the finer scale correlations are presented in a series of sandstone percent maps. Overall, the maps display a strike-elongate (sub-parallel to the present day coastline) orientation for the sandstone bodies which thin to the southeast (basinward). Net sandstone thickness is relatively low in older cycles and increases in younger cycles suggesting an overall progradation of the deltaic system into the mapped area through time. Continued marine regression and southward movement of the shoreline are also confirmed by seismic amplitude 2 maps. After a major transgression associated with Robulus L deltaic progradation occurred under rising sea level conditions. Deltaic sediments prograded southward and sandstone brought to the upper Texas coast was distributed laterally by longshore currents to form strandplain coast lines. Maximum regression occurred during the interval MFS9_2 to MFS9_3 when a deltaic depocenter formed offshore Texas in east High Island area. However, sandstone thickness progressively decreased laterally to the east (offshore Louisiana) where more shale was present and marine processes reworked deltaic derived sandstones into shore parallel bars. There was a clear retreat of the shoreline during the youngest cycle marking the beginning of transgression associated with Amphistegina B . Detailed stratigraphic interpretation (at a 4th order scale) shows more variability in the dominant shoreline processes during early Miocene than previously thought. Recognition of sedimentary systems variability at a 4th order scale is critical for improved hydrocarbon exploration and in understanding potential future CO 2 storage in the area.

58 GEOSCIENCES↗

Direct observation of pore formation mechanisms during LPBF additive manufacturing process and high energy density laser welding

Laser powder bed fusion (LPBF) is a 3D printing technology that can print parts with complex geometries that are unachievable by conventional manufacturing technologies. However, pores formed during the printing process impair the mechanical performance of the printed parts, severely hindering their widespread application. Here, we report six pore formation mechanisms that were observed during the LPBF process. Our results in this study reconfirm three pore formation mechanisms - keyhole induced pores, pore formation from feedstock powder and pore formation along the melting boundary during laser melting from vaporization of a volatile substance or an expansion of a tiny trapped gas. We also observe three new pore formation mechanisms: (1) pore trapped by surface fluctuation, (2) pore formation due to depression zone fluctuation when the depression zone is shallow and (3) pore formation from a crack. The results presented here provide direct evidence and insight into pore formation mechanisms during the LPBF process, which may guide the development of pore elimination/mitigation approaches. Since certain laser processing conditions studied here are similar to the situations in high energy density laser welding, the results presented here also have implications for laser welding.

42 ENGINEERING↗

TU-G-204-04: A Unified Strategy for Bi-Factorial Optimization of Radiation Dose and Contrast Dose in CT Imaging

Purpose: To substantiate the interdependency of contrast dose, radiation dose, and image quality in CT towards the patient- specific optimization of the imaging protocols Methods: The study deployed two phantom platforms. A variable sized (12, 18, 23, 30, 37 cm) phantom (Mercury-3.0) containing an iodinated insert (8.5 mgI/ml) was imaged on a representative CT scanner at multiple CTDI values (0.7–22.6 mGy). The contrast and noise were measured from the reconstructed images for each phantom diameter. Linearly related to iodine-concentration, contrast-to-noise ratio (CNR), were calculated for 16 iodine-concentration levels (0–8.5 mgI/ml). The analysis was extended to a recently developed suit of 58 virtual human models (5D XCAT) with added contrast dynamics. Emulating a contrast-enhanced abdominal image procedure and targeting a peak-enhancement in aorta, each XCAT phantom was “imaged” using a simulation platform (CatSim, GE). 3D surfaces for each patient/size established the relationship between iodine-concentration, dose, and CNR. The ratios of change in iodine-concentration versus dose (IDR) to yield a constant change in CNR were calculated for each patient size. Results: Mercury phantom results show the image-quality size- dependence on CTDI and IC levels. For desired image-quality values, the iso-contour-lines reflect the trade off between contrast-material and radiation doses. For a fixed iodine-concentration (4 mgI/mL), the IDR values for low (1.4 mGy) and high (11.5 mGy) dose levels were 1.02, 1.07, 1.19, 1.65, 1.54, and 3.14, 3.12, 3.52, 3.76, 4.06, respectively across five sizes. The simulation data from XCAT models confirmed the empirical results from Mercury phantom. Conclusion: The iodine-concentration, image quality, and radiation dose are interdependent. The understanding of the relationships between iodine-concentration, image quality, and radiation dose will allow for a more comprehensive optimization of CT imaging devices and techniques, providing the methodology to balance iodine-concentration and dose based on patient’s attributes.

60 APPLIED LIFE SCIENCES↗

Arms Down Cone Beam CT Hepatic Angiography Performance Assessment: Vascular Imaging Quality and Imaging Artifacts

IntroductionThe practice of positioning patients’ arms above the head during catheter-injected hepatic arterial phase cone beam CT (A-CBCT) imaging has been inherited from standard CT imaging due to image quality concerns, but interrupts workflow and extends procedure time. We sought to assess A-CBCT image quality and artifacts with arms extended above the head versus down by the side.MethodsWe performed an IRB approved retrospective evaluation of reformatted and 3D-volume rendered images from 91 consecutive A-CBCTs (43 arms up, 48 arms down) acquired during hepatic tumor arterial embolization procedures. Two interventional radiologists reviewed all A-CBCT imaging and assigned vessel visualization scores (VVS) from 1 to 5, ranging from non-diagnostic to optimal visualization. Streak artifacts across axial images were rated from 1 to 3 based on resulting image quality (none to significant). Presence of respiratory or cardiac motion during acquisition, body mass index and radiation dose area product (DAP) were also recorded and analyzed. Univariate and multivariate analyses were used to assess the impact of arm position on VVS and imaging artifacts.ResultsVVS were not significantly associated with arm position during A-CBCT imaging. One reader reported more streak artifacts across axial images in the arms down group (p = 0.005). DAP was not statistically different between the groups (23.9 Gy cm{sup 2} [6.1–73.4] arms up, 26.1 Gy cm{sup 2} [4.2–102.6] arms down, p = 0.54).ConclusionA-CBCT angiography performed with the arms above the head is not superior for clinically relevant hepatic vascular visualization compared to imaging performed with the arms by the patient’s side.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-18C-03: X-Ray Scatter Correction in Breast CT: Advances and Patient Testing

Purpose: To further develop and perform patient testing of an x-ray scatter correction algorithm for dedicated breast computed tomography (BCT). Methods: A previously proposed algorithm for x-ray scatter signal reduction in BCT imaging was modified and tested with a phantom and on patients. A wireless electronic positioner system was designed and added to the BCT system that positions a tungsten plate in and out of the x-ray beam. The interpolation used by the algorithm was replaced with a radial basis function-based algorithm, with automated exclusion of non-valid sampled points due to patient motion or other factors. A 3D adaptive noise reduction filter was also introduced to reduce the impact of scatter quantum noise post-reconstruction. The impact on image quality of the improved algorithm was evaluated using a breast phantom and seven patient breasts, using quantitative metrics such signal difference (SD) and signal difference-to-noise ratios (SDNR) and qualitatively using image profiles. Results: The improvements in the algorithm resulted in a more robust interpolation step, with no introduction of image artifacts, especially at the imaged object boundaries, which was an issue in the previous implementation. Qualitative evaluation of the reconstructed slices and corresponding profiles show excellent homogeneity of both the background and the higher density features throughout the whole imaged object, as well as increased accuracy in the Hounsfield Units (HU) values of the tissues. Profiles also demonstrate substantial increase in both SD and SDNR between glandular and adipose regions compared to both the uncorrected and system-corrected images. Conclusion: The improved scatter correction algorithm can be reliably used during patient BCT acquisitions with no introduction of artifacts, resulting in substantial improvement in image quality. Its impact on actual clinical performance needs to be evaluated in the future. Research Agreement, Koning Corp., Hologic Inc., Barco Corp Consultant Agreement, Fujifilm Medical Systems.

60 APPLIED LIFE SCIENCES↗

A dedicated cone-beam CT system for musculoskeletal extremities imaging: Design, optimization, and initial performance characterization

Purpose: This paper reports on the design and initial imaging performance of a dedicated cone-beam CT (CBCT) system for musculoskeletal (MSK) extremities. The system complements conventional CT and MR and offers a variety of potential clinical and logistical advantages that are likely to be of benefit to diagnosis, treatment planning, and assessment of therapy response in MSK radiology, orthopaedic surgery, and rheumatology. Methods: The scanner design incorporated a host of clinical requirements (e.g., ability to scan the weight-bearing knee in a natural stance) and was guided by theoretical and experimental analysis of image quality and dose. Such criteria identified the following basic scanner components and system configuration: a flat-panel detector (FPD, Varian 3030+, 0.194 mm pixels); and a low-power, fixed anode x-ray source with 0.5 mm focal spot (SourceRay XRS-125-7K-P, 0.875 kW) mounted on a retractable C-arm allowing for two scanning orientations with the capability for side entry, viz. a standing configuration for imaging of weight-bearing lower extremities and a sitting configuration for imaging of tensioned upper extremity and unloaded lower extremity. Theoretical modeling employed cascaded systems analysis of modulation transfer function (MTF) and detective quantum efficiency (DQE) computed as a function of system geometry, kVp and filtration, dose, source power, etc. Physical experimentation utilized an imaging bench simulating the scanner geometry for verification of theoretical results and investigation of other factors, such as antiscatter grid selection and 3D image quality in phantom and cadaver, including qualitative comparison to conventional CT. Results: Theoretical modeling and benchtop experimentation confirmed the basic suitability of the FPD and x-ray source mentioned above. Clinical requirements combined with analysis of MTF and DQE yielded the following system geometry: a {approx}55 cm source-to-detector distance; 1.3 magnification; a 20 cm diameter bore (20 x 20 x 20 cm{sup 3} field of view); total acquisition arc of {approx}240 deg. The system MTF declines to 50% at {approx}1.3 mm{sup -1} and to 10% at {approx}2.7 mm{sup -1}, consistent with sub-millimeter spatial resolution. Analysis of DQE suggested a nominal technique of 90 kVp (+0.3 mm Cu added filtration) to provide high imaging performance from {approx}500 projections at less than {approx}0.5 kW power, implying {approx}6.4 mGy (0.064 mSv) for low-dose protocols and {approx}15 mGy (0.15 mSv) for high-quality protocols. The experimental studies show improved image uniformity and contrast-to-noise ratio (without increase in dose) through incorporation of a custom 10:1 GR antiscatter grid. Cadaver images demonstrate exquisite bone detail, visualization of articular morphology, and soft-tissue visibility comparable to diagnostic CT (10-20 HU contrast resolution). Conclusions: The results indicate that the proposed system will deliver volumetric images of the extremities with soft-tissue contrast resolution comparable to diagnostic CT and improved spatial resolution at potentially reduced dose. Cascaded systems analysis provided a useful basis for system design and optimization without costly repeated experimentation. A combined process of design specification, image quality analysis, clinical feedback, and revision yielded a prototype that is now awaiting clinical pilot studies. Potential advantages of the proposed system include reduced space and cost, imaging of load-bearing extremities, and combined volumetric imaging with real-time fluoroscopy and digital radiography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-62: Three-Dimensional Dosimetric Gamma Analysis for Impacts of Tissue Inhomogeneity Using Monte Carlo Simulation in Intracavitary Brachytheray for Cervix Carcinoma

Purpose: The aim of this study was to investigate the impacts of tissue inhomogeneity on dose distributions using a three-dimensional (3D) gamma analysis in cervical intracavitary brachytherapy using Monte Carlo (MC) simulations. Methods: MC simulations for comparison of dose calculations were performed in a water phantom and a series of CT images of a cervical cancer patient (stage: Ib; age: 27) by employing a MC code, Particle and Heavy Ion Transport Code System (PHIT) version 2.73. The {sup 192}Ir source was set at fifteen dwell positions, according to clinical practice, in an applicator consisting of a tandem and two ovoids. Dosimetric comparisons were performed for the dose distributions in the water phantom and CT images by using gamma index image and gamma pass rate (%). The gamma index is the minimum Euclidean distance between two 3D spatial dose distributions of the water phantom and CT images in a same space. The gamma pass rates (%) indicate the percentage of agreement points, which mean that two dose distributions are similar, within an acceptance criteria (3 mm/3%). The volumes of physical and clinical interests for the gamma analysis were a whole calculated volume and a region larger than t% of a dose (close to a target), respectively. Results: The gamma pass rates were 77.1% for a whole calculated volume and 92.1% for a region within 1% dose region. The differences of 7.7% to 22.9 % between two dose distributions in the water phantom and CT images were found around the applicator region and near the target. Conclusion: This work revealed the large difference on the dose distributions near the target in the presence of the tissue inhomogeneity. Therefore, the tissue inhomogeneity should be corrected in the dose calculation for clinical treatment.

60 APPLIED LIFE SCIENCES↗

STEREOSCOPIC POLAR PLUME RECONSTRUCTIONS FROM STEREO/SECCHI IMAGES

We present stereoscopic reconstructions of the location and inclination of polar plumes of two data sets based on the two simultaneously recorded images taken by the EUVI telescopes in the SECCHI instrument package onboard the Solar TErrestrial RElations Observatory spacecraft. The 10 plumes investigated show a superradial expansion in the coronal hole in three dimensions (3D) which is consistent with the two-dimensional results. Their deviations from the local meridian planes are rather small with an average of 6.{sup 0}47. By comparing the reconstructed plumes with a dipole field with its axis along the solar rotation axis, it is found that plumes are inclined more horizontally than the dipole field. The lower the latitude is, the larger is the deviation from the dipole field. The relationship between plumes and bright points has been investigated and they are not always associated. For the first data set, based on the 3D height of plumes and the electron density derived from SUMER/SOHO Si VIII line pair, we found that electron densities along the plumes decrease with height above the solar surface. The temperature obtained from the density scale height is 1.6-1.8 times larger than the temperature obtained from Mg IX line ratios. We attribute this discrepancy to a deviation of the electron and the ion temperatures. Finally, we have found that the outflow speeds studied in the O VI line in the plumes corrected by the angle between the line of sight and the plume orientation are quite small with a maximum of 10 km s{sup -1}. It is unlikely that plumes are a dominant contributor to the fast solar wind.

99 GENERAL AND MISCELLANEOUS↗

Toward 2D and 3D imaging of magnetic nanoparticles using EPR measurements

Purpose: Magnetic nanoparticles (MNPs) are an important asset in many biomedical applications. An effective working of these applications requires an accurate knowledge of the spatial MNP distribution. A promising, noninvasive, and sensitive technique to visualize MNP distributions in vivo is electron paramagnetic resonance (EPR). Currently only 1D MNP distributions can be reconstructed. In this paper, the authors propose extending 1D EPR toward 2D and 3D using computer simulations to allow accurate imaging of MNP distributions. Methods: To find the MNP distribution belonging to EPR measurements, an inverse problem needs to be solved. The solution of this inverse problem highly depends on the stability of the inverse problem. The authors adapt 1D EPR imaging to realize the imaging of multidimensional MNP distributions. Furthermore, the authors introduce partial volume excitation in which only parts of the volume are imaged to increase stability of the inverse solution and to speed up the measurements. The authors simulate EPR measurements of different 2D and 3D MNP distributions and solve the inverse problem. The stability is evaluated by calculating the condition measure and by comparing the actual MNP distribution to the reconstructed MNP distribution. Based on these simulations, the authors define requirements for the EPR system to cope with the added dimensions. Moreover, the authors investigate how EPR measurements should be conducted to improve the stability of the associated inverse problem and to increase reconstruction quality. Results: The approach used in 1D EPR can only be employed for the reconstruction of small volumes in 2D and 3D EPRs due to numerical instability of the inverse solution. The authors performed EPR measurements of increasing cylindrical volumes and evaluated the condition measure. This showed that a reduction of the inherent symmetry in the EPR methodology is necessary. By reducing the symmetry of the EPR setup, quantitative images of larger volumes can be obtained. The authors found that, by selectively exciting parts of the volume, the authors could increase the reconstruction quality even further while reducing the amount of measurements. Additionally, the inverse solution of this activation method degrades slower for increasing volumes. Finally, the methodology was applied to noisy EPR measurements: using the reduced EPR setup’s symmetry and the partial activation method, an increase in reconstruction quality of ≈80% can be seen with a speedup of the measurements with 10%. Conclusions: Applying the aforementioned requirements to the EPR setup and stabilizing the EPR measurements showed a tremendous increase in noise robustness, thereby making EPR a valuable method for quantitative imaging of multidimensional MNP distributions.

60 APPLIED LIFE SCIENCES↗

DEEPEN 3D PFA Weights for Exploration Datasets in Magmatic Environments

DEEPEN stands for DE-risking Exploration of geothermal Plays in magmatic ENvironments. As part of the development of the DEEPEN 3D play fairway analysis (PFA) methodology for magmatic plays (conventional hydrothermal, superhot EGS, and supercritical), weights needed to be developed for use in the weighted sum of the different favorability index models produced from geoscientific exploration datasets. This GDR submission includes those weights. The weighting was done using two different approaches: one based on expert opinions, and one based on statistical learning. The weights are intended to describe how useful a particular exploration method is for imaging each component of each play type. They may be adjusted based on the characteristics of the resource under investigation, knowledge of the quality of the dataset, or simply to reduce the impact a single dataset has on the resulting outputs. Within the DEEPEN PFA, separate sets of weights are produced for each component of each play type, since exploration methods hold different levels of importance for detecting each play component, within each play type. The weights for conventional hydrothermal systems were based on the average of the normalized weights used in the DOE-funded PFA projects that were focused on magmatic plays. This decision was made because conventional hydrothermal plays are already well-studied and understood, and therefore it is logical to use existing weights where possible. In contrast, a true PFA has never been applied to superhot EGS or supercritical plays, meaning that exploration methods have never been weighted in terms of their utility in imaging the components of these plays. To produce weights for superhot EGS and supercritical plays, two different approaches were used: one based on expert opinion and the analytical hierarchy process (AHP), and another using a statistical approach based on principal component analysis (PCA). The weights are intended to provide standardized sets of weights for each play type in all magmatic geothermal systems. Two different approaches were used to investigate whether a more data-centric approach might allow new insights into the datasets, and also to analyze how different weighting approaches impact the outcomes. The expert/AHP approach involved using an online tool (https://bpmsg.com/ahp/) with built-in forms to make pairwise comparisons which are used to rank exploration methods against one-another. The inputs are then combined in a quantitative way, ultimately producing a set of consensus-based weights. To minimize the burden on each individual participant, the forms were completed in group discussions. While the group setting means that there is potential for some opinions to outweigh others, it also provides a venue for conversation to take place, in theory leading the group to a more robust consensus then what can be achieved on an individual basis. This exercise was done with two separate groups: one consisting of U.S.-based experts, and one consisting of Iceland-based experts in magmatic geothermal systems. The two sets of weights were then averaged to produce what we will from here on refer to as the "expert opinion-based weights," or "expert weights" for short. While expert opinions allow us to include more nuanced information in the weights, expert opinions are subject to human bias. Data-centric or statistical approaches help to overcome these potential human biases by focusing on and drawing conclusions from the data alone. More information on this approach along with the dataset used to produce the statistical weights may be found in the linked dataset below.

15 GEOTHERMAL ENERGY↗

TH-A-19A-01: An Open Source Software for Proton Treatment Planning in Heterogeneous Medium

Purpose: Due to its success in Radiation Oncology during the last decade, interest in proton therapy is on the rise. Unfortunately, despite the global enthusiasm in the field, there is presently no free, multiplatform and customizable Treatment Planning System (TPS) providing proton dose distributions in heterogenous medium. This restricts substantially the progress of clinical research for groups without access to a commercial Proton TPS. The latest implementation of our pencil beam dose calculation algorithm for proton beams within the 3D Slicer open-source environment fulfills all the conditions described above. Methods: The core dose calculation algorithm is based on the Hong algorithm (1), which was upgraded with the Kanematsu theory describing the evolution of the lateral scattering of proton beamlets in heterogeneous medium. This algorithm deals with both mono-energetic beams and Spread Out Bragg Peak (SOBP). In order to be user-friendly, we provide a graphical user interface implemented with the Qt libraries, and visualization with the 3D Slicer medical image analysis software. Two different pencil beam algorithms were developed, and the clinical proton beam line at our facility was modeled. Results: The dose distributions provided by our algorithms were compared to dose distributions coming from both commercialized XiO TPS and literature (dose measurements, GEANT4 and MCNPx) and turned out to be in a good agreement, with maximum dose discrepancies of 5% in homogeneous phantoms and 10% in heterogeneous phantoms. The algorithm of SOBP creation from an optimized weigthing of mono-energetic beams results in flat SOBP. Conclusion: We hope that our efforts in implementing this new, open-source proton TPS will help the research groups to have a free access to a useful, reliable proton dose calculation software.(1) L. Hong et al., A pencil beam algorithm for proton dose calculations, Phys. Med. Biol. 41 (1996) 1305–1330. This project is paid for by NCI/MGH Federal share as a research grant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-91: Biomechanical Deformable Image Registration of Longitudinal Lung CT Images

Purpose: Spatial correlation of lung tissue across longitudinal images, as the patient responds to treatment, is a critical step in adaptive radiotherapy. The goal of this work is to expand a biomechanical model-based deformable registration algorithm (Morfeus) to achieve accurate registration in the presence of significant anatomical changes. Methods: Four lung cancer patients previously treated with conventionally fractionated radiotherapy that exhibited notable tumor shrinkage during treatment were retrospectively evaluated. Exhale breathhold CT scans were obtained at treatment planning (PCT) and following three weeks (W3CT) of treatment. For each patient, the PCT was registered to the W3CT using Morfeus, a biomechanical model-based deformable registration algorithm, consisting of boundary conditions on the lungs and incorporating a sliding interface between the lung and chest wall. To model the complex response of the lung, an extension to Morfeus has been developed: (i) The vessel tree was segmented by thresholding a vesselness image based on the Hessian matrix’s eigenvalues and the centerline was extracted; (ii) A 3D shape context method was used to find correspondences between the trees of the two images; (ii) Correspondences were used as additional boundary conditions (Morfeus+vBC). An expert independently identified corresponding landmarks well distributed in the lung to compute Target Registration Errors (TRE). Results: The TRE within 15mm of the tumor boundaries (on average 11 landmarks) is: 6.1±1.8, 4.6±1.1 and 3.8±2.3 mm after rigid registration, Morfeus and Morfeus+vBC, respectively. The TRE in the rest of the lung (on average 13 landmarks) is: 6.4±3.9, 4.7±2.2 and 3.6±1.9 mm, which is on the order of the 2mm isotropic dose grid vector (3.5mm). Conclusion: The addition of boundary conditions on the vessels improved the accuracy in modeling the response of the lung and tumor over the course of radiotherapy. Minimizing and modeling these geometrical uncertainties will enable future plan adaptation strategies. This work was funded in part by NIH 2P01CA059827-16.

60 APPLIED LIFE SCIENCES↗

SU-E-J-141: Comparison of Dose Calculation On Automatically Generated MRBased ED Maps and Corresponding Patient CT for Clinical Prostate EBRT Plans

Purpose: To analyze the effect of computing radiation dose on automatically generated MR-based simulated CT images compared to true patient CTs. Methods: Six prostate cancer patients received a regular planning CT for RT planning as well as a conventional 3D fast-field dual-echo scan on a Philips 3.0T Achieva, adding approximately 2 min of scan time to the clinical protocol. Simulated CTs (simCT) where synthesized by assigning known average CT values to the tissue classes air, water, fat, cortical and cancellous bone. For this, Dixon reconstruction of the nearly out-of-phase (echo 1) and in-phase images (echo 2) allowed for water and fat classification. Model based bone segmentation was performed on a combination of the DIXON images. A subsequent automatic threshold divides into cortical and cancellous bone. For validation, the simCT was registered to the true CT and clinical treatment plans were re-computed on the simCT in pinnacle{sup 3}. To differentiate effects related to the 5 tissue classes and changes in the patient anatomy not compensated by rigid registration, we also calculate the dose on a stratified CT, where HU values are sorted in to the same 5 tissue classes as the simCT. Results: Dose and volume parameters on PTV and risk organs as used for the clinical approval were compared. All deviations are below 1.1%, except the anal sphincter mean dose, which is at most 2.2%, but well below clinical acceptance threshold. Average deviations are below 0.4% for PTV and risk organs and 1.3% for the anal sphincter. The deviations of the stratifiedCT are in the same range as for the simCT. All plans would have passed clinical acceptance thresholds on the simulated CT images. Conclusion: This study demonstrated the clinical usability of MR based dose calculation with the presented Dixon acquisition and subsequent fully automatic image processing. N. Schadewaldt, H. Schulz, M. Helle and S. Renisch are employed by Phlips Technologie Innovative Techonologies, a subsidiary of Royal Philips NV.

60 APPLIED LIFE SCIENCES↗

Semiautomatic segmentation of liver metastases on volumetric CT images

Purpose: Accurate segmentation and quantification of liver metastases on CT images are critical to surgery/radiation treatment planning and therapy response assessment. To date, there are no reliable methods to perform such segmentation automatically. In this work, the authors present a method for semiautomatic delineation of liver metastases on contrast-enhanced volumetric CT images. Methods: The first step is to manually place a seed region-of-interest (ROI) in the lesion on an image. This ROI will (1) serve as an internal marker and (2) assist in automatically identifying an external marker. With these two markers, lesion contour on the image can be accurately delineated using traditional watershed transformation. Density information will then be extracted from the segmented 2D lesion and help determine the 3D connected object that is a candidate of the lesion volume. The authors have developed a robust strategy to automatically determine internal and external markers for marker-controlled watershed segmentation. By manually placing a seed region-of-interest in the lesion to be delineated on a reference image, the method can automatically determine dual threshold values to approximately separate the lesion from its surrounding structures and refine the thresholds from the segmented lesion for the accurate segmentation of the lesion volume. This method was applied to 69 liver metastases (1.1–10.3 cm in diameter) from a total of 15 patients. An independent radiologist manually delineated all lesions and the resultant lesion volumes served as the “gold standard” for validation of the method’s accuracy. Results: The algorithm received a median overlap, overestimation ratio, and underestimation ratio of 82.3%, 6.0%, and 11.5%, respectively, and a median average boundary distance of 1.2 mm. Conclusions: Preliminary results have shown that volumes of liver metastases on contrast-enhanced CT images can be accurately estimated by a semiautomatic segmentation method.

60 APPLIED LIFE SCIENCES↗

SU-E-J-203: Reconstruction of the Treatment Area by Use of Sinogram in Helical Tomotherapy

Purpose: TomoTherapy (Accuray Co.) has an image-guided radiotherapy system with megavoltage (MV) X-ray source and the on-board imaging device. With the MV computed tomography (MVCT), it became feasible to perform the efficient daily-3D registration of the patient position before each treatment delivery. This system also allows one to acquire the delivery sinogram during the actual treatment, which partly includes the information of the irradiated object. In this study, we try to develop the image reconstruction during treatment in helical Tomotherapy. Methods: Sinogram data were acquired during helical Tomotherapy delivery using an arc-shaped detector array that consists of 738 xenon-gas filled detector cells. In preprocessing, these were normalized by full air-scan data. A software program was developed that reconstructs 3D images during treatment with corrections as; (1) the regions outside the field were masked not to be added in the backprojection (a masking correction), and (2) each voxel of the reconstructed image was divided by the number of the X-ray passing through its voxel (a ray-passing correction). Results: Without masking and ray-passing corrections, the image reconstruction was failed. The masking correction made the image clear, however, the streak artifact was accompanied. The ray-passing correction reduced this artifact. Although the SNR (the ratio of mean to standard deviation in homogeneous region) and the contrast of the reconstructed image were slightly improved with the ray-passing correction, the masking correction only is enough for the visualization purpose. Conclusion: The visualization of the treatment area was feasible by use of the sinogram in helical Tomotherapy. This proposed method can be utilized in the treatment verification. This work was partly supported by JSPS KAKENHI 24234567. No COI, but the data in this paper were prepared by collaborators in Accuray.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-G-JeP2-06: Dosimetric and Workflow Evaluation of First Commercial Synthetic CT Software for Clinical Use in Pelvis

Purpose: evaluate a commercial synthetic CT (syn-CT) software for use in prostate radiotherapy Methods: Twenty prostate patients underwent CT and MR simulation scans in treatment position on a 3T Philips scanner. The MR protocol consisted of a T2w turbo spin-echo for soft tissue contrast, a 2D balanced-fast field echo (b-FFE) for fiducial identification, a dual-echo 3D FFE B0 map for distortion analysis and a 3D mDIXON FFE sequence to generate syn-CT. Two echoes are acquired during mDIXON scan, allowing water, fat, and in-phase images to be derived using the frequency shift of the fat and water protons. Tissues were classified as: air, adipose, water, trabecular/spongy bone and compact/cortical bone and assigned specific bulk HU values. Bone structures are segmented based on a pelvis bone atlas. Accuracy of syn-CT for patient treatment planning was analyzed by transferring the original plan and structures from the CT to syn-CT via rigid registration and recalculating dose. In addition, new IMRT plans were generated on the syn-CT using structures contoured on MR and transferred to the syn-CT. Accuracy of fiducial-based localization at the treatment machine performed using syn-CT or DRRs generated from syn-CT was assessed by comparing to orthogonal kV radiographs or CBCT. Results: Dosimetric comparison between CT and syn-CT was within 0.5% for all structures. The de-novo optimized plans generated on the syn-CT met our institutional clinical objectives for target and normal structures. Patient-induced susceptibility distortion based on B0 maps was within 1mm and 0.4 mm in the body and prostate. The rectal and bladder outlines on the syn-CT were deemed sufficient for assessing rectal and bladder filling on the CBCT at the time of treatment. CBCT localization showed a median error of < ±1 mm in LR, AP and SI direction. Conclusion: MRI derived syn-CT can be used clinically in MR-alone planning and treatment process for prostate. Drs. Deasy, Hunt and Tyagi have Master research agreement with Philips healthcare.

60 APPLIED LIFE SCIENCES↗

Characterization of the Transmission of the Elekta Stereotactic Body Frame (ESBF) and Accounting for it During Treatment Planning

The purpose of this study was to measure the transmission of the Elekta Stereotactic Body Frame (ESBF) and treatment table, to calculate the transmission of the frame in the Eclipse Treatment Planning System (TPS) using analytical anisotropic algorithm (AAA), and to demonstrate a simple method of accounting for this transmission in treatment planning. A solid water body phantom was imaged inside the ESBF and planned with multiple 3D-CRT fields using AAA using both 6-MV and 16-MV energies. In the first set of plans, the frame and table were included in the 'Body' contour and, therefore, used in the dose calculations. In the second set of plans, the frame and the table were not included in the 'Body' contour and, therefore, were not incorporated in the calculations. The latter simulated a setup in which there was no frame or table. Eclipse TPS will only incorporate data from the CT set in calculations, if it is included in the 'Body' contour. The plans were treated under two conditions: one with the phantom in the ESBF and one without the frame on a specially designed table. This table allows all the beams to enter the phantom without passing through any attenuating material (i.e., table or frame). Transmission of the frame and table was determined by the ratio of the measurements with the frame and table to the measurements without them. To validate the accuracy of the calculation model, plans with homogeneous phantom and a heterogeneous plan were compared with the measurements. The transmission of the frame varies from 89-94% depending on the angle of the beams and whether they also intercept the table. The AAA algorithm calculated the transmission of the frame and table to within 2% of the measurements for all gantry angles. Validation results showed that AAA can calculate the dose to the target to within 2% of the measured value. The attenuation caused by the ESBF must be accounted for in the planning process. For Eclipse, the frame should be contoured and included in all calculations. This can be done easily and accurately.

61 RADIATION PROTECTION AND DOSIMETRY↗

Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at positions closer to attenuating hardware structures of the RF coil. The position accuracy of the RF coil on the patient table when using the positioning frame was determined well below 1 mm for all three spatial dimensions. This ensures perfect position match between the RF coil and its three-dimensional attenuation template during the PET data reconstruction process. When applying the CT-based AC of the RF coil, the global attenuation bias was mostly compensated to ±0.5% across the entire breast imaging volume. The patient study revealed high quality MR, PET, and combined PET/MR imaging of breast cancer. Quantitative activity measurements in all 11 breast cancer lesions of the ten patients resulted in increased mean difference values of SUV{sub max} 11.8% (minimum 3.2%; maximum 23.2%) between nonAC images and images when AC of the RF breast coil was applied. This supports the quantitative results of the phantom study as well as successful attenuation correction of the RF coil. Conclusions: A 16-channel breast RF coil was designed for optimized MR imaging performance and PET transparency and was successfully integrated with its dedicated attenuation correction template into a whole-body PET/MR system. Systematic PET/MR imaging evaluation with phantoms and an initial study on patients with breast cancer provided excellent MR and PET image quality and accurate PET quantification.

60 APPLIED LIFE SCIENCES↗