Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “visual system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Millimeter-wave imaging diagnostics systems on the EAST tokamak (invited)

Millimeter-wave imaging diagnostics, with large poloidal span and wide radial range, have been developed on the EAST tokamak for visualization of 2D electron temperature and density fluctuations. A 384 channel (24 poloidal × 16 radial) Electron Cyclotron Emission Imaging (ECEI) system in F-band (90-140 GHz) was installed on the EAST tokamak in 2012 to provide 2D electron temperature fluctuation images with high spatial and temporal resolution. A co-located Microwave Imaging Reflectometry (MIR) will be installed for imaging of density fluctuations by December 2016. This “4th generation” MIR system has eight independent frequency illumination beams in W-band (75-110 GHz) driven by fast tuning synthesizers and active multipliers. Both of these advanced millimeter-wave imaging diagnostic systems have applied the latest techniques. A novel design philosophy “general optics structure” has been employed for the design of the ECEI and MIR receiver optics with large aperture. The extended radial and poloidal coverage of ECEI on EAST is made possible by innovations in the design of front-end optics. The front-end optical structures of the two imaging diagnostics, ECEI and MIR, have been integrated into a compact system, including the ECEI receiver and MIR transmitter and receiver. Two imaging systems share the same mid-plane port for simultaneous, co-located 2D fluctuation measurements of electron density and temperature. An intelligent remote-control is utilized in the MIR electronics systems to maintain focusing at the desired radial region even with density variations by remotely tuning the probe frequencies in about 200 μs. A similar intelligent technique has also been applied on the ECEI IF system, with remote configuration of the attenuations for each channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observations with the Differential Speckle Survey Instrument. X. Preliminary Orbits of K-dwarf Binaries and Other Stars

This paper details speckle observations of binary stars taken at the Lowell Discovery Telescope, the WIYN telescope, and the Gemini telescopes between 2016 January and 2019 September. The observations taken at Gemini and Lowell were done with the Differential Speckle Survey Instrument (DSSI), and those done at WIYN were taken with the successor instrument to DSSI at that site, the NN-EXPLORE Exoplanet Star and Speckle Imager (NESSI). In total, we present 378 observations of 178 systems, and we show that the uncertainty in the measurement precision for the combined data set is ∼2 mas in separation, ∼1°–2° in position angle depending on the separation, and ∼0.1 mag in magnitude difference. Together with data already in the literature, these new results permit 25 visual orbits and one spectroscopic-visual orbit to be calculated for the first time. In the case of the spectroscopic-visual analysis, which is done on the ternary star HD 173093, we calculate masses with a precision of better than 1% for all three stars in that system. Twenty-one of the visual orbits calculated have a K dwarf as the primary star; we add these to the known orbits of K-dwarf primary stars and discuss the basic orbital properties of these stars at this stage. Although incomplete, the data that exist so far indicate that binaries with K-dwarf primaries tend not to have low-eccentricity orbits at separations of one to a few tens of astronomical units, that is, on solar system scales.

47 OTHER INSTRUMENTATION↗

Coherent tunneling by adiabatic passage in an optical waveguide system

We report on an experimental demonstration of light transfer in an engineered triple-well optical waveguide structure which provides a classic analog of coherent tunneling by adiabatic passage (CTAP) recently proposed for coherent transport in space of neutral atoms or electrons among tunneling-coupled optical traps or quantum wells [A. D. Greentree et al., Phys. Rev. B 70, 235317 (2004); K. Eckert et al., Phys. Rev. A 70, 023606 (2004)]. The direct visualization of CTAP wave-packet dynamics enabled by our simple optical system clearly shows that in the counterintuitive passage scheme light waves tunnel between the two outer wells without appreciable excitation of the middle well.

74 ATOMIC AND MOLECULAR PHYSICS↗

Delineation of nuclear structures in 3D multicellular systems

A pipeline, implemented within the Insight Segmentation and Registration Toolkit (ITK) and The Visualization Toolkit (VTK) framework, to delineate each nucleus and to profile morphometric and colony organization. At an abstract level, our approach is an extension of a previously developed method for monolayer call structure models.

Source record↗

Primary Frequency Control Using Motor Drives for Short Term Grid Disturbances

Industrial motor systems make up a quarter of all electric sales in the United States. Variable speed drives (VSDs) can provide energy efficiency savings to the customer by regulating motor speed based on specific and varying needs. In addition to the benefits provided to the customer, VSDs can provide support to the grid through ancillary services. The Center for Ultra-Wide-Area Resilient Electric Energy Transmission Networks (CURENT) developed a power electronics converter-based grid emulator to allow testing of various power system architectures and demonstration of key technologies in monitoring, control, actuation, and visualization. This paper proposes using an active front-end VSD's connected motor load to provide frequency regulation to a large scale power grid. Each part of the emulator is described including motor and power electronics model and control. The proposed frequency regulation is implemented in VSDs and modeled in both a transmission system in EMTDC/PSCAD and verified on CURENT's hardware testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Network portal: a database for storage, analysis and visualization of biological networks

The ease of generating high-throughput data has enabled investigations into organismal complexity at the systems level through the inference of networks of interactions among the various cellular components (genes, RNAs, proteins and metabolites). The wider scientific community, however, currently has limited access to tools for network inference, visualization and analysis because these tasks often require advanced computational knowledge and expensive computing resources. We have designed the network portal (http://networks.systemsbiology.net) to serve as a modular database for the integration of user uploaded and public data, with inference algorithms and tools for the storage, visualization and analysis of biological networks. The portal is fully integrated into the Gaggle framework to seamlessly exchange data with desktop and web applications and to allow the user to create, save and modify workspaces, and it includes social networking capabilities for collaborative projects. While the current release of the database contains networks for 13 prokaryotic organisms from diverse phylogenetic clades (4678 co-regulated gene modules, 3466 regulators and 9291 cis-regulatory motifs), it will be rapidly populated with prokaryotic and eukaryotic organisms as relevant data become available in public repositories and through user input. The modular architecture, simple data formats and open API support community development of the portal.

59 BASIC BIOLOGICAL SCIENCES↗

Materials Informatics ChemVis

A Browser-based visualization of morphology, material, and chemical data extracted from chemical papers. This UI is focused for specifically nanomaterial synthesis papers. The visual analytic environment allows the user to explore a large number of papers quickly, through an interactive, intuitive, and visual way that helps see possible trends in the data. This exploration-oriented systems allows domain experts who may not have an extensive background in writing analysis code or database queries to easily express their idea to experiment on the data and view the results. The visualization software requires the data in JSON format. The data packaged with the software is the result of 35k nanomaterial synthesis papers queried from Elsevier, created through a separate software pipeline. The data contains information such as the title, authors, chemicals, and created material and morphology.

Liu, Shusen↗

The Evolution of the Bacterial Luciferase Gene Cassette (lux) as a Real-Time Bioreporter

The bacterial luciferase gene cassette (lux) is unique among bioluminescent bioreporter systems due to its ability to synthesize and/or scavenge all of the substrate compounds required for its production of light. As a result, the lux system has the unique ability to autonomously produce a luminescent signal, either continuously or in response to the presence of a specific trigger, across a wide array of organismal hosts. While originally employed extensively as a bacterial bioreporter system for the detection of specific chemical signals in environmental samples, the use of lux as a bioreporter technology has continuously expanded over the last 30 years to include expression in eukaryotic cells such as Saccharomyces cerevisiae and even human cell lines as well. Under these conditions, the lux system has been developed for use as a biomedical detection tool for toxicity screening and visualization of tumors in small animal models. As the technologies for lux signal detection continue to improve, it is poised to become one of the first fully implantable detection systems for intra-organismal optical detection through direct marriage to an implantable photon-detecting digital chip. This review presents the basic biochemical background that allows the lux system to continuously autobioluminesce and highlights the important milestones in the use of lux-based bioreporters as they have evolved from chemical detection platforms in prokaryotic bacteria to rodent-based tumorigenesis study targets. In addition, the future of lux imaging using integrated circuit microluminometry to image directly within a living host in real-time will be introduced and its role in the development of dose/response therapeutic systems will be highlighted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Split-pane electrochromic window control based on an embedded photometric device with real-time daylighting computing

Well-designed electrochromic (EC) glazing control can improve the energy performance of buildings and visual comfort of occupants in highly glazed buildings. Here in this paper, we designed and demonstrated a compact integrated EC glazing automation system to control tint states of a split-pane EC window according to variations of sky conditions. The control is based on monitoring the luminance distribution of the sky and real-time lighting computation for a building interior, using an embedded photometric device (EPD). It optimizes tint states of EC glazing to offer sufficient daylight provision and temper discomfort glare for occupants, which potentially mitigates excessive solar heat gain. ’In-situ’ experiments were conducted in a full-scale testbed to demonstrate the daylighting performance under various sky conditions. Finally, experimental results showed 83% of the working time for work-plane illuminance (WPI) and 95% of the time for daylight glare probability (DGP) were constrained in comfort range (WPIϵ[500, 2000] lux, DGP ≤ 0.35) by the automated EC glazing (controlled by EPD) under clear skies; 68% of the time for WPI and 94% of the time for DGP in confined range under clear skies with thin clouds; 62% of the time for WPI and 85% of the time for DGP in confined range under partly cloudy skies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An energy-resolved atomic scanning probe

We propose a method to probe the local density of states (LDOS) of atomic systems that provides both spatial and energy resolution. The method combines atomic and tunneling techniques to supply a simple, yet quantitative and operational, definition of the LDOS for both interacting and non-interacting systems: it is the rate at which particles can be siphoned from the system of interest by a narrow energy band of non-interacting states contacted locally to the many-body system of interest. Ultracold atoms in optical lattices are a natural platform for implementing this broad concept to visualize the energy and spatial dependence of the atom density in interacting, inhomogeneous lattices. This includes models of strongly correlated condensed matter systems, as well as ones with non-trivial topologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visualization of Simulation and TAP Interaction

The Temporal Analysis of Products (TAP) Reactor applies transient kinetics to analyze sophisticated chemical reaction mechanisms, rapidly changing temperature, flow rate, pressure or concentration and then monitoring the system’s time dependent response. A simulation tool exists for the TAP reactor, but it requires a visualization platform to interface effectively with researchers. This graphical user interface remedies this problem, fixing many of the difficulties caused by users interacting directly with the simulation code by providing an intuitive web application that satisfies the simulation input parameters for fast generation of data. This tool will ensure robust and repeatable simulation results, expedite the data generating process and enhance the overall ability of TAP to produce significant findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visualization at Supercomputing Centers: The Tale of Little Big Iron and the Three Skinny Guys

Supercomputing Centers (SC's) are unique resources that aim to enable scientific knowledge discovery through the use of large computational resources, the Big Iron. Design, acquisition, installation, and management of the Big Iron are activities that are carefully planned and monitored. Since these Big Iron systems produce a tsunami of data, it is natural to co-locate visualization and analysis infrastructure as part of the same facility. This infrastructure consists of hardware (Little Iron) and staff (Skinny Guys). Our collective experience suggests that design, acquisition, installation, and management of the Little Iron and Skinny Guys does not receive the same level of treatment as that of the Big Iron. The main focus of this article is to explore different aspects of planning, designing, fielding, and maintaining the visualization and analysis infrastructure at supercomputing centers. Some of the questions we explore in this article include:"How should the Little Iron be sized to adequately support visualization and analysis of data coming off the Big Iron?" What sort of capabilities does it need to have?" Related questions concern the size of visualization support staff:"How big should a visualization program be (number of persons) and what should the staff do?" and"How much of the visualization should be provided as a support service, and how much should applications scientists be expected to do on their own?"

97 MATHEMATICS AND COMPUTING↗

WE-D-BRD-01: New Linac Designs for MR-Guided Therapy Systems

The advantages that make MR highly desirable for in-room treatment guidance, i.e. soft-tissue visualization and physiological assessment of healthy/tumor tissues, are largely recognized in the research community. However, the MR absorption in practical clinical workflows is still hindered by lack of sufficient technological infrastructure. Recent advances have been made towards filling that gap such as the development of integrated therapy systems relying on an MR scanner and a radiation source (linac, Co-60) and/or brachytherapy. The session is intended to present new efforts and methods aimed at facilitating the adoption of MR guidance for treatment delivery. Specifically, the discussion will focus on a) linac designs for reduced footprint and seamless integration with MR/linac systems, b) tracking coils for brachytherapy applications, and c) procedures for the commissioning and monitoring of MR and MR/linac performance. Learning Objectives: Understand limitations and proposed solutions for linac designs and associated integration with MR/linac systems; Understand current issues with MR-guided brachytherapy procedures Understand the issues and needs for new MR commissioning and QC. License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image distortions.

60 APPLIED LIFE SCIENCES↗

Deep Active Learning for Solvability Prediction in Power Systems

Traditional methods for solvability region analysis can only have inner approximations with inconclusive conservatism and handle limited types of power flow models. In this letter, we propose a deep active learning framework for solvability prediction in power systems. Compared with passive learning where the training is performed after all instances are labeled, active learning selects most informative instances to be labeled and therefore significantly reduces the size of the labeled dataset for training. In the active learning framework, the acquisition functions, which correspond to different sampling strategies, are defined in terms of the on-the-fly posterior probability from the classifier. First, the IEEE 39-bus system is employed to validate the proposed framework, where a two-dimensional case is illustrated to visualize the effectiveness of the sampling method followed by the high-dimensional numerical experiments. Then, the Northeast Power Coordinating Council (NPCC) 140-bus system is used to validate the performance on large-scale power systems.

42 ENGINEERING↗

Multifunctional Biomedical Imaging in Physiological and Pathological Conditions Using a NIR-II Probe

Contrasted with imaging in the visible (400–650 nm) and near-infrared window I (NIR-I, 650–900 nm) regions, imaging in near-infrared window II (NIR-II, 1000–1700 nm) is a highly promising in vivo imaging modality with improved resolution and deeper tissue penetration. Here, a small molecule NIR-II dye,5,5'-(1H,5H-benzo[1,2-c:4,5-c'] bis[1,2,5]thiadiazole)-4,8-diyl)bis(N,N-bis(4-(3-((tert-butyldimethylsilyl)oxy)propyl)phenyl) thiophen-2-amine), is successfully encapsulated into phospholipid vesicles to prepare a probe CQS1000. The novel NIR-II probe is studied for in vivo multifunctional biological imaging. The results of this study indicate that the NIR-II vesicle CQS1000 can noninvasively and dynamically visualize and monitor many physiological and pathological conditions of circulatory systems, including lymphatic drainage and routing, angiogenesis of tumor, and vascular deformity such as arterial thrombus formation and ischemia with high spatial and temporal resolution. More importantly, by virtue of the favorable half-life of blood circulation of CQS1000, NIR-II imaging is capable of aiding precise resection of tumor such as osteosarcoma and accelerating the process of lymph node dissection to complete sentinel lymph node biopsy for better decision making during the tumor surgery. Overall, CQS1000 is a highly promising NIR-II probe for multifunctional biomedical imaging in physiological and pathological conditions, surpassing traditional NIR-I imaging modality and pathologic assessments for clinical diagnosis and treatment.

36 MATERIALS SCIENCE↗

Fabrication of Arrays of Topological Solitons in Patterned Chiral Liquid Crystals for Real-Time Observation of Morphogenesis

Topological solitons have knotted continuous field configurations embedded in a uniform background, and occur in cosmology, biology, and electromagnetism. However, real-time observation of their morphogenesis and dynamics is still challenging because their size and timescale are enormously large or tiny. Liquid crystal (LC) structures are promising candidates for a model-system to study the morphogenesis of topological solitons, enabling direct visualization due to the proper size and timescale. We report a new way is found to rationalize the real-time observation of the generation and transformation of topological solitons using cholesteric LCs confined in patterned substrates. The experimental demonstration shows the topologically protected structures arise via the transformation of topological defects. Numerical modeling based on minimization of free energy closely reconstructs the experimental findings. The fundamental insights obtained from the direct observations pose new theoretical challenges in understanding the morphogenesis of different types of topological solitons within a broad range of scales.

36 MATERIALS SCIENCE↗

A genetically encoded, high-signal-to-noise maltose sensor

We describe the generation of a family of high-signal-to-noise single-wavelength genetically encoded indicators for maltose. This was achieved by insertion of circularly permuted fluorescent proteins into a bacterial periplasmic binding protein (PBP), Escherichia coli maltodextrin-binding protein, resulting in a four-color family of maltose indicators. The sensors were iteratively optimized to have sufficient brightness and maltose-dependent fluorescence increases for imaging, under both one- and two-photon illumination. We demonstrate that maltose affinity of the sensors can be tuned in a fashion largely independent of the fluorescent readout mechanism. Using literature mutations, the binding specificity could be altered to moderate sucrose preference, but with a significant loss of affinity. We use the soluble sensors in individual E. coli bacteria to observe rapid maltose transport across the plasma membrane, and membrane fusion versions of the sensors on mammalian cells to visualize the addition of maltose to extracellular media. The PBP superfamily includes scaffolds specific for a number of analytes whose visualization would be critical to the reverse engineering of complex systems such as neural networks, biosynthetic pathways, and signal transduction cascades. We expect the methodology outlined here to be useful in the development of indicators for many such analytes.

59 BASIC BIOLOGICAL SCIENCES↗

Visualization of specific collagen-producing cells by Col1-GFP transgenic mice revealed novel type I collagen-producing cells other than fibroblasts in systemic organs/tissues

Highlights: • A new reporter mouse was generated to label type I collagen-producing cells. • Type I collagen-producing cells were specifically labeled in this reporter mouse. • Podocytes and Leydig cells showed the ability to produce type I collagen. Type I collagen is one of the most abundant proteins in mammals and plays important roles in maintaining the integrity of many tissues. Although fibroblasts are the main source of type I collagen, other cells also produce it; however, these cells are not well-defined owing to the lack of a specific marker. A transgenic (Tg) mouse line has been generated in which type I collagen-producing cells are labeled with enhanced green fluorescent protein (EGFP), which enables the monitoring of these cells without requiring an additional cell marker. This Tg mouse line has since been widely used to study type I collagen-producing cells and fibrosis; one study revealed that podocytes, which were not previously considered to produce type I collagen, expressed EGFP. This raises a question regarding the specificity of EGFP expression in this Tg mouse line. To exclude the possibility of non-specific EGFP expression in the existing Tg mouse line and specifically monitor type I collagen-producing cells, we generated a new Tg mouse line and histologically confirmed the specificity of EGFP expression throughout the body. Moreover, we explored type I collagen-producing cells other than fibroblasts and revealed for the first time that Leydig cells have the ability to produce type I collagen. Because of its highly specific and physiologically accurate expression, our new Tg mouse line will help to accurately elucidate not only type I collagen-producing cells in normal tissues but also the potential cells in fibrotic tissues, providing new insights into the pathology of fibrosis.

60 APPLIED LIFE SCIENCES↗