Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable energy generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Multiscale Thermal-hydraulic analysis of the MARVEL microreactor using a coupled SAM and SCM simulation. (PPTX)

This is .pptx document presenting a summary of the paper of the same name that has been submitted and accepted to NURETH-21: MARVEL is a natural-convection-cooled sodium-potassium microreactor that is anticipated to generate 85 kilowatts of thermal energy. It will operate within Idaho National Laboratory Transient Reactor Test Facility and is being developed by the DOE Microreactor Program. MARVEL will be used to test microreactor applications, evaluate systems for remote monitoring, and develop autonomous control technologies. A thermal-hydraulic computational model of this facility is a valuable tool to study important transients and calculate the safety limits of the micro-reactor design. For this purpose, the authors have chosen to use a multiscale coupled simulation: SCM for modeling the reactor core and SAM for the reactor's primary cooling system. SCM is MOOSE physics module for subchannel analysis, which was designed to model single-phase flows through liquid-metal cooled, wire-wrapped fuel pin sub-assemblies, ordered in a triangular lattice. The SCM code was modified to be able to model MARVEL?s unique geometry. SAM is a systems analysis module based on the MOOSE framework. It aims to provide fast-running, whole-plant transient analyses capability with improved-fidelity for various advanced reactor types. The coupling between the two SCM and SAM for MARVEL modeling is done implementing a domain over-lapping approach. The resulting coupled simulation can model transients such as reactor startup/shutdown and provide an intermediate fidelity picture of the temperature field and other variables, in the core. Results for the steady-state simulations are presented in the article as well as flow blockage transient.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Open Source High Fidelity Modeling of a Type-5 Wind Turbine Drivetrain

The increasing integration of renewable energy resources in evolving bulk power system (BPS) is impacting the system inertia. Type-5 wind turbine generation has the potential to behave like a traditional synchronous generator and can help mitigate the impact on system inertia. A hydraulic torque converter (TC) and gearbox with torque limiting feature are integral parts of a Type-5 wind turbine unit. A high fidelity model of Type-5 wind turbine drivetrain is not openly and widely available for grid integration and transient stability studies. This hinders appropriate assessment of Type-5 wind power plant’s contribution to bulk grid resilience. This work develops and validates a TC model based on those generally used in automobile’s transmission system. Moreover, the concept of torsional coupling is leveraged to integrate the TC and gearbox system dynamics. The entire integrated model will be open sourced and publicly available for grid integration studies.

17 WIND ENERGY↗

Multiscale Thermal-hydraulic analysis of the MARVEL micro-reactor using coupled MOOSE Subchannel (SCM) and SAM

MARVEL is a natural-convection-cooled sodium-potassium microreactor that is anticipated to generate 85 kilowatts of thermal energy. It will operate within Idaho National Laboratory’s Transient Reactor Test Facility and is being developed by the DOE Microreactor Program. MARVEL will be used to test microreactor applications, evaluate systems for remote monitoring, and develop autonomous control technologies. A thermal-hydraulic computational model of this facility is a valuable tool to study important transients and calculate the safety limits of the micro-reactor design. For this purpose, the authors have chosen to use a multiscale coupled simulation: SCM for modeling the reactor core and SAM for the reactor’s primary cooling system. SCM is MOOSE physics module for subchannel analysis, which was designed to model single-phase flows through liquid-metal cooled, wire-wrapped fuel pin sub-assemblies, ordered in a triangular lattice. The SCM code was modified to be able to model MARVEL’s unique geometry. SAM is a systems analysis module based on the MOOSE framework. It aims to provide fast-running, whole-plant transient analyses capability with improved-fidelity for various advanced reactor types. The coupling between the two SCM and SAM for MARVEL modeling is done implementing a domain over-lapping approach. The resulting coupled simulation can model transients such as reactor startup/shutdown and provide an intermediate fidelity picture of the temperature field and other variables, in the core. Results for the steady-state simulations are presented in the article as well as flow blockage transient.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Accurate Consensus-based Distributed Averaging with Variable Time Delay in Support of Distributed Secondary Control Algorithms

We report that distributed secondary control has been widely used in hierarchical control structures, where multiple distributed generators (DGs) need to coordinate to regulate system voltage and frequency. In these systems, consensus algorithms determine the average of a group of dynamic states (e.g. voltages measured by a group of DGs). To be useful, consensus algorithms must be computationally efficient, stable and accurate. In practice, numerous practical implementation challenges significantly affect the consensus equilibrium. In this paper, we quantify the accuracy deviations of the distributed average observer algorithms proposed in the literature to demonstrate the problems with the state-of-the-art distributed averaging techniques. A novel approach is proposed that achieves accurate average tracking in the presence of time-varying communication delays among agents. In our implementation, time synchronization of all distributed controllers is enabled by a novel software platform, called Resilient Information Architecture Platform for the Smart Grid (RIAPS). The proposed distributed average observer is implemented on hardware controllers and its effectiveness is validated in a controller hardware-in-the-loop testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hybrid Power Plants: Status of Operating and Proposed Plants, 2024 Edition [Slides]

Improving battery technology and the growth of variable renewable generation are driving a surge of interest in “hybrid” power plants that combine, for example, wind or solar generating capacity with co-located batteries. While most of the current interest involves pairing photovoltaic (PV) plants with batteries, other types of hybrid or co-located plants with wide-ranging configurations have been part of the U.S. electricity mix for decades. This annually updated briefing tracks and maps existing hybrid or co-located plants across the United States while also synthesizing data from power purchase agreements (PPAs) and generation interconnection queues to shed light on near- and long-term development pipelines. The scope includes “co-located hybrids” that pair two or more resources (e.g., multiple types of generation and/or generation with storage) that are operated largely independently behind a single point of interconnection, and “full hybrids” that also feature coordinated operations of the co-located resources. The focus is on plants with one megawatt (MW) or more of capacity; smaller (often behind-the-meter) projects are also increasingly common, but are not included in this data synthesis.

14 SOLAR ENERGY↗

Minimization of Measurement Uncertainty in Optical Frequency Domain Reflectometry

Optical frequency domain reflectometry (OFDR) is a technique for interrogating optical fiber sensors to generate relative, quasi-distributed measurements. Although Optical frequency domain reflectometry (OFDR) is increasingly being adopted for aerospace, energy production, and structural monitoring applications, the quantification of uncertainty for OFDR measurements has not been developed beyond sparse empirical relationships. To address this knowledge gap, an uncertainty metric for OFDR measurements was developed. This uncertainty metric was applied to weight the edges between OFDR measurements on directed correlation graphs and analyzed to minimize the cumulative uncertainty. In conclusion, this work is the first to propose an uncertainty metric for OFDR and provides a generalized mathematical framework for optimizing OFDR hardware selection, optical fiber sensor selection, and postprocessing strategy.

42 ENGINEERING↗

Mitigating the noise of DESI mocks using analytic control variates

In order to address fundamental questions related to the expansion history of the Universe and its primordial nature with the next generation of galaxy experiments, we need to model reliably large-scale structure observables such as the correlation function and the power spectrum. Cosmological N-body simulations provide a reference through which we can test our models, but their output suffers from sample variance on large scales. Fortunately, this is the regime where accurate analytic approximations exist. To reduce the variance, which is key to making optimal use of these simulations, we can leverage the accuracy and precision of such analytic descriptions using Control Variates (CV). The power of control variates stems from utilizing inexpensive but highly correlated surrogates of the statistics one wishes to measure. The stronger the correlation between the surrogate and the statistic of interest, the larger the variance reduction delivered by the method. We apply two control variate formulations to mock catalogs generated in anticipation of upcoming data from the Dark Energy Spectroscopic Instrument (DESI) to test the robustness of its analysis pipeline. Our CV-reduced measurements offer a factor of 5-10 improvement in the measurement error compared with the raw measurements. We explore the relevant properties of the galaxy samples that dictate this reduction and comment on the improvements we find on some of the derived quantities relevant to Baryon Acoustic Oscillation (BAO) analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Grid-Integrated Production of Fischer-Tropsch Synfuels from Nuclear Power

Idaho National Laboratory (INL) investigates the relative economic profitability of an integrated energy system (IES) coupling an NPP with a synfuel production process at selected case study locations across the United States. In the synfuel IES, a high-temperature steam electrolysis (HTSE) plant is thermally and electrically coupled with an NPP to produce zero-carbon hydrogen. The synthetic fuel is produced from this H 2 combined with a CO 2 supply using the reverse water gas shift process followed by the Fischer-Tropsch (FT) reaction. This analysis considers a system in which the CO 2 is sourced from regional CO 2 emitters via the construction and operation of pipeline-based CO 2 supply networks. Locating the FT plant at the same site as the NPP and HTSE plants enables the NPP to provide zero-carbon heat and power to the HTSE plant and zero-carbon power to the FT plant as well as avoid the requirement for long-distance H 2 product transport from the HTSE plant to the FT plant. Hydrogen storage is used to enable the NPP to dispatch power to the electrical grid (instead of the HTSE plant) when grid demand increases, thus enabling the FT plant to continue to operate in a steady-state production mode. The ability to cease hydrogen production for several hours within each day enables the NPP to provide power to the grid to balance the electricity market during peak periods and maximize revenues for the nuclear synfuel IES. The FT process design considered has a 99% carbon conversion efficiency. The use of nuclear energy and nuclear energy-derived hydrogen enables synfuel production to achieve this high level of carbon utilization. Additionally, the life-cycle carbon emissions of the nuclear-based synfuel production process are very low, with WTW emissions of approximately 25 gCO 2 e/MJ, including steam credits (generated from FT process excess heat), and approximately 7 gCO 2 e/MJ, if steam credits are excluded. This compares favorably with the WTW emissions of 90.5 gCO 2 e/MJ for a compression-ignition, direct injection (CIDI) vehicle with a fuel economy of 31.6 miles per gallon gasoline equivalent (MPGGE), using low-sulfur diesel produced using conventional petroleum production and refining processes. Several NPPs in various regions of the U.S. are considered as case study analyses. Supply locations and transportation via pipeline of the CO 2 feedstock to the NPP site are analyzed through the National Energy Technology Laboratory (NETL) CO 2 Transport Cost model. The team finds that the amount of CO 2 generated by different sectors is sufficient for the synfuel production process at all locations considered. The CO 2 transportation costs are functions of the distance of the source to the NPP location, the CO 2 capture cost at the source, and the quantity of CO 2 transported. Historical electricity prices for the NPP case study locations are collected and analyzed. Monthly average prices, price range, and duration of negative-price periods vary among these locations. For each location, an auto-regressive moving average (ARMA) model is trained on historical electricity price data. ARMA validation is done to ensure the synthetic price distributions represent one of historical prices with high fidelity. Synthetic time series from these ARMA models are used in a coupled dispatch and system optimization in the Holistic Energy Resource Optimization Network (HERON) to compute the differential net present value (NPV) of the IES. The team finds that this econometric is positive, ranging from $14M–1.3bn (2020) depending on the location. The optimal synfuel IES configuration to obtain this increase in NPV often maximizes the size of the synfuel production process with regards to the size of the NPP. However, the team shows that the NPP still plays a stabilizing role for the grid: In periods of high prices and high loads, more electricity from the NPP is sent to the grid. A high variability of electricity prices and extreme maximum prices tend to drive up electricity production. While it requires significant investment, the synfuel IES could increase the economic profitability for the existing fleet of LWRs across the country while still maintaining the grid stabilizer role of NPPs. During its lifetime, the main costs for the nuclear synfuel IES are the carbon feedstock transportation costs, followed by the capital expenses (CAPEX) and operation and maintenance (O&M) costs while the revenue comes first from the IRA H 2 production tax credit (PTC) and then from the sales of synfuel products. The profitability of the synfuel IES is most sensitive to the value of the hydrogen PTC and the synfuel products as well as the cost of the carbon feedstock, highlighting the importance of governmental incentives regarding hydrogen, carbon emissions, and synfuel in driving the deployment of future nuclear synfuel IESs.

08 HYDROGEN↗

A simplified, efficient approach to hybrid wind and solar plant site optimization

Abstract. Wind plant layout optimization is a difficult, complex problem with a large number of variables and many local minima. Layout optimization only becomes more difficult with the addition of solar generation. In this paper, we propose a parameterized approach to wind and solar hybrid power plant layout optimization that greatly reduces problem dimensionality while guaranteeing that the generated layouts have a desirable regular structure. Thus far, hybrid power plant optimization research has focused on system sizing. We go beyond sizing and present a practical approach to optimizing the physical layout of a wind–solar hybrid power plant. We argue that the evolution strategy class of derivative-free optimization methods is well-suited to the parameterized hybrid layout problem, and we demonstrate how hard layout constraints (e.g., placement restrictions) can be transformed into soft constraints that are amenable to optimization using evolution strategies. Next, we present experimental results on four test sites, demonstrating the viability, reliability, and effectiveness of the parameterized evolution strategy approach for generating optimized hybrid plant layouts. Completing the tool kit for parameterized layout generation, we include a brief tutorial describing how the parameterized evolutionary approach can be inspected, understood, and debugged when applied to hybrid plant layouts.

14 SOLAR ENERGY↗

Deconvolving the roles of E × B shear and pedestal structure in the energy confinement quality of super H-mode experiements

Analysis of “super H-mode” experiments on DIII-D has put forward that high plasma toroidal rotation, not high pedestal, plays the essential role in achieving energy confinement quality H 98y2 >>1. Recently, super H-mode experiments with variable input torque have confirmed that high rotation shear discharges have very high levels of H 98y2 (>1.5), independent of the pedestal height, and that high pedestal discharges with low rotation shear have levels of H 98y2 only slightly above 1 (≤1.2). Although some increase in stored energy with higher pedestal occurs, the energy confinement quality mainly depends on the toroidal rotation shear, which varies according to different levels of injected neutral beam torque per particle. Here, quasi-linear gyrofluid modeling achieves a good match of the experiment when including the E×B shear; without including plasma rotation, the modeling predicts a confinement quality consistent with the empirical observation of H 98y2 ~1.2 at low rotation. Nonlinear gyrokinetic transport modeling shows that the effect of E×B turbulence stabilization is far larger than other mechanisms, such as the so-called hot-ion stabilization (T i /T e ) effect. Consistent with these experimental and modeling results are previous simulations of the ITER Baseline Scenario using a super H-mode pedestal solution, which showed the potential to exceed the Q=10 target if the pedestal density could be increased above the Greenwald limit. A close look at these simulations reveals that the predicted energy confinement quality is below 1 even at the highest pedestal pressure. The improvement in Q at higher pedestal density is due to the improved fusion power generation at the higher core density associated with higher pedestal density, not to an improved energy confinement quality.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigations into Balancing Peak-to-Average Power Ratio and Mean Power Extraction for a Two-Body Point-Absorber Wave Energy Converter

The power harnessed by wave energy converters (WECs) in oceans is highly variable and, therefore, has a high peak-to-average power (PTAP) ratio. To minimize the cost of a WEC power take off (PTO) system, it is desirable to reduce the PTAP ratio while maximizing the mean power extracted by WECs. The important issue of how PTAP ratio reduction measures (such as adding an inertia element) can affect the mean power extracted in a reference model has not been thoroughly addressed in the literature. To investigate this correlation, this study focuses on the integration of the U.S. Department of Energy’s Reference Model 3, a two-body point absorber, with a slider-crank WEC for linear-to-rotational conversion. In the first phase of this study, a full-scale numerical model was developed that predicts how PTO system parameters, along with an advanced control algorithm, can potentially affect the proposed WEC’s PTAP ratio as well as the mean power extracted. In the second phase, an appropriate scaled-down model was developed, and extracted power results were successfully validated against the full-scale model. Finally, numerical and hardware-in-the-loop (HIL) simulations based on the scaled-down model were designed and conducted to optimize or make trade-offs between the operational performance and PTAP ratio. The initial results with numerical and HIL simulations reveal that gear ratio, crank radius, and generator parameters substantially impact the PTAP ratio and mean power extracted.

16 TIDAL AND WAVE POWER↗

The effect of water vapor on surface oxygen exchange kinetics of thin film (La,Sr)(Co,Fe)O 3-δ

Oxygen reduction and transport in electrochemical applications are strongly affected by the reactant gas composition, including impurities such as water. Understanding the relationship between oxygen reactivity and humidity is key for attaining stability and high efficiency of solid oxide fuel cells, which are especially attractive for transportation applications as low emission power generation devices. Both short- and long-term effects of moisture have previously been associated with use of ambient air. To better understand these effects, we study oxygen exchange kinetics at the cathode surface and the cathode/electrolyte interface using La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3-δ (LSCF) epitaxial thin films as a model-surface system. In situ synchrotron X-ray techniques evaluate the oxygen reduction reaction (ORR) kinetics in response to environmental variables. The results suggest a clear enhancement of the ORR rate upon short term exposure of the perovskite-structured films to water. Finally, on the basis of these measurements, along with in situ X-ray characterization of Sr segregation and computational first-principles studies, we suggest a model for this increased ORR activity that may lead to further improvements by stabilizing active cathode surface configurations.

25 ENERGY STORAGE↗

Hierarchical Control of Utility-Scale Solar PV Plants for Mitigation of Generation Variability and Ancillary Service Provision

This paper presents a hierarchical control system to mitigate the variability of solar photovoltaic (PV) power plant and provide ancillary services to the electric grid without the need for additional non-solar resources. With coordinated management of each inverter in the system, the control system commands the power plant to proactively curtail a small fraction of its instantaneous maximum power potential, which gives the plant enough headroom to ramp up production from the overall power plant, for a service such as regulation reserve. This control system is practical for continuously changing cloud cover conditions in partially cloudy days. A case study from a site in Hawaii with one-second resolution solar irradiance data is used to verify the efficacy of the proposed control system. The proposed control algorithm is subsequently compared with the alternative control technology from the literature, the grouping control algorithm; the results show that the proposed hierarchical control system is over 10 times more effective in reducing generator mileage to support power fluctuations from solar PV power plants.

14 SOLAR ENERGY↗

Load Profile Inpainting for Missing Load Data Restoration and Baseline Estimation

This paper introduces a Generative Adversarial Nets (GAN) based, Load Profile Inpainting Network (Load-PIN) for restoring missing load data segments and estimating the baseline for a demand response event. The inputs are time series load data before and after the inpainting period together with explanatory variables (e.g., weather data). Here, we propose a Generator structure consisting of a coarse network and a fine-tuning network. The coarse network provides an initial estimation of the data segment in the inpainting period. The fine-tuning network consists of self-attention blocks and gated convolution layers for adjusting the initial estimations. Loss functions are specially designed for the fine-tuning and the discriminator networks to enhance both the point-to-point accuracy and realisticness of the results. We test the Load-PIN on three real-world data sets for two applications: patching missing data and deriving baselines of conservation voltage reduction (CVR) events. We benchmark the performance of Load-PIN with five existing deep-learning methods. Our simulation results show that, compared with the state-of-the-art methods, Load-PIN can handle varying-length missing data events and achieve 15-30% accuracy improvement.

14 SOLAR ENERGY↗

Benchmarking soil moisture and its relationship to ecohydrologic variables in Earth System Models

Soil moisture (SM) is a key regulator of ecosystem biogeophysics, influencing plant water relations and land-atmosphere energy exchanges. We evaluate the representation of SM in 16 Earth System Models from the Coupled Model Intercomparison Project Phase 6 (CMIP6) using the International Land Model Benchmarking (ILAMB) framework, focusing on surface (0–5, 0–10 cm) and rootzone (0–100 cm) depths, as well as key ecohydrological variables like gross primary productivity (GPP), leaf area index (LAI), and evapotranspiration (ET), and their coupling. Models are benchmarked against multiple observational and assimilated datasets to assess both state variables and cross-variable relationships. Surface SM is generally well represented (r > 0.87), while rootzone SM variability is systematically overestimated (normalized standard deviation > 1). ET shows strong agreement with observations (r > 0.9), whereas GPP and LAI exhibit larger inter-model spread. Skill in individual variables does not guarantee realistic SM–ecohydrology coupling, which varies strongly across models and depends on the reference dataset. Köppen-based regional analyses reveal strong regime dependence, with several models performing well in Tropical and Temperate regions but degrading in Continental (high-latitude) zones. Across both global and regional benchmarks, models cluster by land surface framework, indicating that structural choices in soil hydrology and soil–plant coupling exert a first-order control on performance. These results provide process-relevant benchmarks and suggest that improving the representation of vertical soil structure, rooting depth distributions, and soil–plant hydraulic coupling will be central to advancing soil moisture realism in next-generation Earth system models.

CMIP6↗

Development of Stable Solid Oxide Electrolysis Cells for Low-Cost Hydrogen Production

The project objective was to demonstrate a solid oxide cell-based steam electrolysis stack that exhibits robustness, reliability, endurance, hydrogen purity, and produces hydrogen at elevated pressure of 2 to 3 bar. Innovative materials and processing methods were evaluated to improve degradation characteristics. Performance improvement focused on nearly all layers involved in the cell and stack assembly. Primary attention was paid to zirconia-ceria interface resistance control via sintering optimization and decrease in degradation from the oxygen electrode by evaluating low strontium (Sr) or Sr-free composition for both the oxygen electrode and current collection layer. Stack robustness was addressed by validating redox tolerance of fuel electrode, confirming capability of cells to survive repeated thermal cycles, studying the effect of pressure on performance and degradation, evaluating the effect of contamination on fuel and oxygen electrode performance and degradation, and identifying mitigation strategies to improve performance. The characterization included evaluation of electrochemical performance and stability followed by microstructural analysis. At the cell level, performance and stability improvements were achieved by incorporating a Sr-free oxygen electrode and a denser oxygen electrode barrier layer. At the stack level, pressurized operation reduces demand on first stage compression, the redox tolerant fuel electrode mitigates risk from service interruptions, and improvements to interconnect coating alleviate chromium (Cr) contamination effects. The denser barrier layer was achieved by adding a sintering aid to the samaria-doped ceria (SDC) composition that reduced sintering temperature by 150 °C. The resulting density was on par with the baseline SDC barrier layer density and the lower sintering temperature resulted in less resistive phase formation during sintering. Button cell tests did not demonstrate a change in performance when exposed to silicon (Si) or manganese (Mn) impurities to the fuel electrode and Cr impurity to the oxygen electrode. More detailed study however is warranted. The project addressed SOEC performance and stability at the cell and stack levels through a systematic approach to known sources of degradation that were combined and tested in three stack tests using an electrolyte supported cell design to allow for evaluation of a variety of fuel and oxygen electrode compositions. STK-82 and STK-83 had identical compositions. STK-100 incorporated the best materials and processing variables developed under this and concurrent projects, and was tested at elevated pressure in steam electrolysis. • STK-82 recovered performance after redox and thermal cycling, demonstrating the robustness of the stack and seals. It exhibited stable performance in testing for 500 hours in SOEC mode, followed by 300 hours of cycling between SOEC and SOFC tests. Degradation during SOEC operation was 1.8 %/ 1,000 hours. • STK-83 generated hydrogen at >80% steam conversion, and oxygen above 98.5 % purity during pressurized operation. Both hydrogen and oxygen were generated at 3 barg pressure without the use of a pressure vessel. In addition to balanced pressure, electrolysis operation at 1 bar differential pressure across anode and cathode was also demonstrated to substantial the robustness of the cell and seal. • STK-100 measured at initial ambient pressure conditions showed an area specific resistance of 1.1 ohm-cm 2 , and STK-83 had 1.3 ohm-cm 2 .

08 HYDROGEN↗

Formulations and Valid Inequalities for Optimal Black Start Allocation in Power Systems

The restoration of a power system after a blackout starts around units with enhanced technical capabilities, referred to as black start units (BSUs). We examine the planning problem of optimally allocating these units on the grid subject to a budget constraint. We present a mixed integer programming model based on current literature in power systems. Binary variables are associated with the allocation of BSUs and with the energization state of buses, branches, and generators of the power system over a time horizon. We extract a substructure of the feasible region which imposes the requirement that each island that appears during the restoration process must have at least one operational generator. We discuss three equivalent reformulations for this requirement. We introduce a family of exponentially many, polynomially separable, valid inequalities to strengthen the formulation. Under simplifying assumptions, we show that the convex hull of the feasible region is a full-dimensional polyhedron, and prove that some of the constraints we introduced are facet-defining. We perform experiments to examine the difference in strength between the formulations as well as the computational times to solve the problem to near optimality for synthetic instances of the IEEE-39, IEEE-118, Illinois-200, WECC-225, IEEE-300, South Carolina-500, and Texas-2000 power systems. We illustrate a use case of the model. We conclude by suggesting extensions of the current work for future research.

Black Start Allocation↗

Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments

We discuss the need to understand materials exposed to overlapping extreme environments such as high temperature, radiation, or mechanical stress. When these stressors are combined there may be synergistic effects that enable unique microstructural evolution mechanisms to activate. Understanding of these mechanisms is necessary for the input and refinement of predictive models and critical for engineering of next generation materials. The basic physics and underlying mechanisms require advanced tools to be investigated. The in situ ion irradiation transmission electron microscope (I 3 TEM) is designed to explore these principles. To quantitatively probe the complex dynamic interactions in materials, careful preparation of samples and consideration of experimental design is required. Particular handling or preparation of samples can easily introduce damage or features that obfuscate the measurements. There is no one correct way to prepare a sample; however, many mistakes can be made. The most common errors and things to consider are highlighted within. The I 3 TEM has many adjustable variables and a large potential experimental space, therefore it is best to design experiments with a specific scientific question or questions in mind. Experiments have been performed on large number of sample geometries, material classes, and with many irradiation conditions. The following are a subset of examples that demonstrate unique in situ capabilities utilizing the I 3 TEM. Au nanoparticles prepared by drop casting have been used to investigate the effects of single ion strikes. Au thin films have been used in studies on the effects of multibeam irradiation on microstructure evolution. Zr films have been exposed to irradiation and mechanical tension to examine creep. Ag nanopillars were subjected to simultaneous high temperature, mechanical compression, and ion irradiation to study irradiation induced creep as well. These results impact fields including: structural materials, nuclear energy, energy storage, catalysis, and microelectronics in space environments.

47 OTHER INSTRUMENTATION↗