Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “transmissive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Ga speciation in Ga/H-ZSM-5 by in-situ transmission FTIR spectroscopy

H-ZSM-5 supported Ga (Ga/H-ZSM-5) has long been recognized as a promising catalyst for nonoxidative dehydrogenation and dehydroaromatization of alkanes. However, Ga speciation under reaction conditions remains controversial. In this work, in-situ transmission Fourier Transform infrared (FTIR) spectroscopy is employed to systematically investigate Ga speciation in Ga/H-ZSM-5 with three Si/Al ratios (15, 28 and 39) and a wide range of Ga/Al ratios (0–1.7). Quantitative FTIR spectroscopy with pyridine reveals that one Ga atom roughly replaces one Brønsted acid site (BAS) at Ga/BAS ratio up to 0.7, however, only up to ~80% of the BAS on the H-ZSM-5 can be exchanged even with excess amounts of Ga. At a low Si/Al ratio of 15, the intensity of GaH x bands on reduced Ga/H-ZSM-5 at 550 °C increases almost linearly at low Ga loadings (Ga/Al < 0.13), and then levels off. In contrast, no detectable GaH x bands are observed on Ga/H-ZSM-5 with a high Si/Al ratio of 39, with Ga/Al ratios up to 1.3. The dependence of GaH x bands on both the Si/Al ratios and the Ga/Al ratios shows that Ga speciation varies with BAS density in the zeolite. We hypothesize that paired BAS sites are preferentially exchanged with Ga + , leading to the formation of Ga + –H + pair sites, while the exchange of isolated BAS form isolated Ga+ species. Using water as a probe molecule, we show that isolated Ga + and Ga + –H + pair sites have distinct properties, i.e., the former can be easily oxidized by water at 150 °C to form GaOOH species, while the latter is inactive under the same conditions. Furthermore, these results provide direct experimental evidence for the existence of two types of Ga species on reduced Ga/H-ZSM-5, highlighting the possibility that they have different catalytic activities in alkane dehydrogenation reactions.

03 NATURAL GAS↗

Transmission electron microscopy study of a high burnup U-10Zr metallic fuel

To support the development of U-10 wt.% Zr (U-10Zr) metallic fuel for Gen IV sodium-cooled fast reactors, we analysed a solid, Na-bonded, U-10Zr (by weight percent) fuel cross section that was irradiated to a burnup of ~ 12.4 % at.% at the Fast Flux Test Facility (FFTF). Advanced characterization techniques, including site specific sample preparation by focused ion beam (FIB) and phase/chemical determination by transmission electron microscopy (TEM), were used to reveal the constituent redistribution of Zr, characterize the fuel phases and the secondary phases (such as solid fission products) present at the end of life. It is shown that the fuel pin cross section is divided into three major concentric zones: a Zr-rich central region, a Zr-lean intermediate region, and a Zr intermediate peripherical region. The phase characterization revealed that the irradiation environment enhanced the development and stabilization of phases not predicted by the standard equilibrium U-Zr phase diagrams. Comparing the current results with the ones from previous studies, it is reaffirmed that the irradiation temperature and the time spent in the reactor, rather than the fuel burnup, are the two factors that most influence the formation of redistribution zones and their extension along the fuel cross section. Various solid fission products precipitated inside the fission gas pores, such as lanthanides, ZrRu, BaTe, CsI, and Ba and Sr oxides. Here, this study provides unprecedented nanoscale understandings in the U-10Zr fuel system that may benefit fuel performance modelling and advanced fuel development.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Identification of uranium oxidation states using oxygen K-edge scanning transmission X-ray microscopy

The field of nuclear forensics is growing in importance, and the increasing capabilities at synchrotron radiation light sources enable non-destructive characterization of oxide particles with better spatial, compositional, and oxidation state speciation resolution than ever before. Here, uranium oxide particles derived from multiple wet chemical processing methods were examined using a scanning transmission X-ray microscope (STXM), and a weakly-supervised method was developed to automatically analyze the collected data. Multiple uranium oxidation states were observed and quantified within and between samples, yielding information about differences between particles produced via the various processing routes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In situ transmission electron microscopy with dual ion beam irradiation and implantation

To study the helium effects and their interactions with displacement damage in irradiated materials, an in situ dual-ion beam irradiation capability with transmission electron microscopy was recently established at the IVEM-Tandem Facility at Argonne National Laboratory. Pure nickel was irradiated in situ individually with 1 MeV Kr ions for displacement damage study, 16 keV He ions for helium implantation, and simultaneously with 1 MeV Kr ions and 16 keV He ions at the rate of 1 at.% He/dpa to study the interaction of helium and displacement damage at 500 degrees C. Helium bubbles were formed and segregated within dislocation loops during the He implantation experiment and no bubbles were observed outside the loops. The loop size increased with increasing helium concentration. In contrast, helium bubbles were formed uniformly in the matrix when nickel was irradiated simultaneously with 1 MeV Kr ions and 16 keV He ions. Overall, it is suggested that the uniformly-distributed defect clusters formed under 1 MeV Kr ion irradiation serve as trapping sites of helium atoms resulting in homogeneous nucleation of helium bubbles under the dualion beam irradiation in nickel.

36 MATERIALS SCIENCE↗

Correlated transmission electron microscopy and atom probe tomography characterization of ion irradiated Ni-based alloy Hastelloy N

Ion irradiation of Hastelloy N was conducted to better characterize the effects of irradiation on Hastelloy N using modern tools compared to studies done in the 1950s. The 2 MeV Ni + ion irradiation at 600 °C of Hastelloy N has been investigated using atom probe tomography, transmission electron microscopy and energy dispersive spectroscopy. Irradiation is found to promote formation of nanoscale M 2 C carbides over the thermodynamically favored M 6 C. Segregation of Si to dislocation loops and grain boundaries was also evident and may have assisted in formation of M 2 C. These microstructural changes result in a 20 % hardness increase caused by irradiation alone. These observations are useful in the design of new materials better suited for the harsh environment of a molten salt reactor.

Atom probe tomography↗

Water vapor transmission rate measurement for moisture barriers using infrared imaging

Here, in this work, we demonstrate a spatially resolved imaging methodology for water vapor transmission rate (WVTR) testing that relies on quantified infrared characterization at water absorption bands. This technique is validated using a moisture barrier on a polymer substrate via calibration of the infrared image intensity with moisture content in the polymer substrate from images taken at different times. The method is compared to existing state of the art techniques such as membrane permeation measurement with coulometric phosphorous pentoxide sensor and optical calcium film testing. This fast, non-destructive and in-situ method enables defect visualization and shows the WVTR with a sensitivity limit of 5·10 –5 g/m 2 /day.

47 OTHER INSTRUMENTATION↗

Quantitative nanoscale tracking of oxygen vacancy diffusion inside single ceria grains by in situ transmission electron microscopy

Oxygen vacancy formation and migration in ceria is critical to its electrochemical and catalytic properties in systems for chemical and energy transformation, but its quantification is rather challenging especially at atomic-scale because of disordered distribution. Here we report a rational approach to track oxygen vacancy diffusion in single grains of pure and Sm-doped ceria at -20 °C to 160 °C using in situ (scanning) transmission electron microscopy ((S)TEM). To create a gradient in oxygen vacancy concentration, a small region (~30 nm in diameter) inside a ceria grain is reduced to the C-type CeO 1.68 phase by the ionization or radiolysis effect of a high-energy electron beam. The evolution in oxygen vacancy concentration is then mapped through lattice expansion measurement using scanning nano-beam diffraction or 4D STEM at a spatial resolution better than 2 nm; this allows direct determination of local oxygen vacancy diffusion coefficients in a very small domain inside pure and Sm-doped ceria at different temperatures. Further, the activation energies for oxygen transport are determined to be 0.59, 0.66, 1.12, and 1.27 eV for pure CeO 2 , Ce 0.94 Sm 0.06 O 1.97 , Ce 0.89 Sm 0.11 O 1.945 , and Ce 0.8 Sm 0.2 O 1.9 , respectively, implying that activation energy increases due to impurity scattering. The results are qualitatively supported by density functional theory (DFT) calculations. In addition, our in situ TEM investigation reveals that dislocations impede oxygen vacancy diffusion by absorbing oxygen vacancies from the surrounding areas and pinning them locally. With more oxygen vacancies absorbed, dislocations show extended strain fields with local tensile zone sandwiched between the compressed ones. Therefore, dislocation density should be reduced in order to minimize the resistance to oxygen vacancy diffusion at low temperatures.

36 MATERIALS SCIENCE↗

Pulsed-Beam Transmission Electron Microscopy and Radiation Damage

Here, we review the use of pulsed electron-beams in transmission electron microscopes (TEMs) for the purpose of mitigating specimen damage. We begin by placing the importance of TEMs with respect to materials characterization into proper context, and we provide a brief overview of established methods for reducing or eliminating the deleterious effects of beam-induced damage. We then introduce the concept of pulsed-beam TEM, and we briefly describe the basic methods and instrument configurations used to create so-called temporally structured electron beams. Following a brief overview of the use of high-dose-rate pulsed-electron beams in cancer radiation therapy, we review historical speculations and more recent compelling but mostly anecdotal findings of a pulsed-beam TEM damage effect. This is followed by an in-depth technical review of recent works seeking to establish cause-and-effect relationships, to conclusively uncover the presence of an effect, and to explore the practicality of the approach. These studies, in particular, provide the most compelling evidence to date that using a pulsed electron beam in the TEM is indeed a viable way to mitigate damage. Throughout, we point out current gaps in understanding, and we conclude with a brief perspective of current needs and future directions.

36 MATERIALS SCIENCE↗

Effects of elevated temperature exposure on the residual stress state and microstructure of PVD Cr coatings on SiC investigated via in situ X-ray diffraction and transmission electron microscopy

Pure Cr coatings are being considered as corrosion-resistant layers for SiC-SiC f composite fuel cladding in light water reactors. The residual stress state and interdiffusion behavior of Cr coatings deposited on SiC substrates using bipolar high-power impulse magnetron sputtering (B-HiPIMS) and direct current impulse magnetron sputtering (DCMS) were studied using in situ X-ray diffraction experiments at 300 °C, 700 °C, and 1200 °C. After elevated temperature exposure, evolution of the coating microstructure and coating/substrate interdiffusion was characterized by transmission electron microscopy. The compressive residual stress of the dense B-HiPIMS coating at room temperature was gradually relieved at 300 °C, while the stress transitioned to a tensile state at 700 °C. Grain growth of the Cr coating and a Cr–SiC interdiffusion layer consisting of newly formed Cr–C and Cr–Si phases were observed in the B-HiPIMS coating after exposure at 700 °C. The phases in the interdiffusion layer were identified to be Cr 7 C 3 , Cr 3 Si, and Cr 5 Si 3 C x experimentally and by thermodynamic predictions. For the DCMS coating, however, changes in residual stress and microstructure at the elevated temperatures were limited by the inherent porosity and inhomogeneous structure of the as-deposited coating. At 1200 °C, both coating types interacted rapidly with the underlying SiC substrate in the early stages of the experiment. The results from this study suggest that the characteristics of the Cr coatings do not significantly change at the reactor operating temperature of 300 °C, while changes in microstructure and stress state are expected in off-normal conditions of 700 °C and 1200 °C. Finally the results from this study suggest the B-HiPIMS coating is best-suited as a protective coating for SiC fuel cladding.

36 MATERIALS SCIENCE↗

Hydraulic performance and wave transmission through nature-inspired perforated hollow-base piles breakwater

Nature-based Solutions (NbS) are critical to achieving long-term sustainable coastlines in deltaic coastlines, particularly susceptible to severe impacts under climate change. In recent years, coastal erosion has accelerated in the Vietnam Mekong Delta (VMD), particularly in the West Sea (from Ca Mau to Kien Giang). Due to the characteristics of muddy coastlines and eroded mangrove forests in this region, only a few engineering solutions have effectively reduced waves and promoted sediment accumulation to facilitate beach accretion. However, these solutions require significant investment and cannot be relocated or reused. Therefore, this study introduces a coastal mangrove-inspired perforated hollow-base piles breakwater (PHBPB), which uses the principle of biomimicry by studying the ability of mangrove groups to protect the coastline, stimulate sediment deposition, and over time, restore mangrove forests in the VMD. The hydraulic parameters of PHBPB were tested in 260 scenarios using a physical model, which included varying parameters such as crest width (B), pile row numbers (n c ), crest freeboard (R c ), and wave parameters (H s , T p ) in determining the capabilities of wave transmission, reflection, and wave dissipation. The results showed that the process of wave energy dissipation through perforated hollow-base breakwaters without piles (PHBBWP) is governed by three main parameters, including the relative water depth of the crest (R c /H m0,i ), the relative width of the crest (B/H m0,i ), and the wave slope at the structure location (s m = H m0,i /L m ). In contrast, for PHBPB, the primary influencing factors are the relative submergence depth or the length of the submerged pile portion (R c /H m0,i ) and the relative width of the pile system (X b /L m ). Finally, the hollow structure is suitable for the soft, weak mud geology in this region with poor load-bearing capacity, allows for rapid installation, is reasonably cost-effective, and can be relocated and reused once regeneration has been completed in each stretch of coastline.

54 ENVIRONMENTAL SCIENCES↗

Cepstral scanning transmission electron microscopy imaging of severe lattice distortions

The development of four-dimensional (4D) scanning transmission electron microscopy (STEM) using fast detectors has opened-up new avenues for addressing some of longstanding challenges in electron imaging. One of these challenges is how to image severely distorted crystal lattices, such as at a dislocation core. Here we develop a new 4D-STEM technique, called Cepstral STEM, for imaging disordered crystals using electron diffuse scattering. In contrast to analysis based on Bragg diffraction, which measures the average and periodic scattering potential, electron diffuse scattering can detect fluctuations caused by crystal disorder. Local fluctuations of diffuse scattering are captured by scanning electron nanodiffraction (SEND) using a coherent probe. The harmonic signals in electron diffuse scattering are detected through Cepstral analysis and used for imaging. By integrating Cepstral analysis with 4D-STEM, we demonstrate that information about the distortive part of electron scattering potential can be separated and imaged at nm spatial resolution. Here, we apply the technique to the analysis of a dislocation core in SiGe and lattice distortions in a high entropy alloy.

36 MATERIALS SCIENCE↗

Stroboscopic ultrafast imaging using RF strip-lines in a commercial transmission electron microscope

The development of ultrafast electron microscopy (UEM), specifically stroboscopic imaging, has brought the study of structural dynamics to a new level by overcoming the spatial limitations of ultrafast spectroscopy and the temporal restrictions of traditional TEM simultaneously. Combining the concepts governing both techniques has enabled direct visualization of dynamics with spatiotemporal resolutions in the picosecond-nanometer regime. Here, in this study, we push the limits of imaging using a pulsed electron beam via RF induced transverse deflection based on the newly developed 200 keV frequency-tunable strip-line pulser. We demonstrate 0.2 nm spatial resolution at high magnifications and elucidation of Lorentz imaging using the phase-microscopy method. We also present beam coherence measurements and expand our study using the breathing modes of a silicon interdigitated comb under RF excitation which achieves improved temporal synchronization between the electron pulse-train and electric field. A new RF holder has also been developed with impedance matching to the RF signal to minimize transmission power loss to samples and its performance is compared with a conventional sample holder.

47 OTHER INSTRUMENTATION↗

Reconstructing the exit wave of 2D materials in high-resolution transmission electron microscopy using machine learning

Reconstruction of the exit wave function is an important route to interpreting high-resolution transmission electron microscopy (HRTEM) images. Here we demonstrate that convolutional neural networks can be used to reconstruct the exit wave from a short focal series of HRTEM images, with a fidelity comparable to conventional exit wave reconstruction. We use a fully convolutional neural network based on the U-Net architecture, and demonstrate that we can train it on simulated exit waves and simulated HRTEM images of graphene-supported molybdenum disulphide (an industrial desulfurization catalyst). We then apply the trained network to analyse experimentally obtained images from similar samples, and obtain exit waves that clearly show the atomically resolved structure of both the MoS 2 nanoparticles and the graphene support. We also show that it is possible to successfully train the neural networks to reconstruct exit waves for 3400 different two-dimensional materials taken from the Computational 2D Materials Database of known and proposed two-dimensional materials.

2D materials↗

Fluctuation cepstral scanning transmission electron microscopy of mixed-phase amorphous materials

Four-dimensional scanning transmission electron microscopy (4D-STEM) is a versatile analytical tool for characterizing materials structural properties. However, extending such analysis to disordered materials is challenging, especially in technologically important samples with mixed ordered and disordered phases. Here, in this work, we present a new 4D-STEM method, called fluctuation cepstral STEM (FC-STEM), based on the fluctuation analysis of cepstral transform of diffraction patterns. The peaks in the associated transformation relate to inter-atomic distances in a thin sample. By varying the real-space range over which fluctuations are calculated, distinct ordered and disordered phases can be mapped in a diffractive image reconstruction. We demonstrate the principles of FC-STEM by characterizing a silicon anode, harvested from a cycled lithium-ion battery. A mixture of amorphous and nanocrystalline silicon, graphitic carbon, and electrolyte by-products is identified and mapped. Comparisons with conventional electron imaging and energy-dispersive X-ray spectroscopy show that FC-STEM is highly effective for the structure determination of mixed-phase amorphous materials.

36 MATERIALS SCIENCE↗

Atomic resolution scanning transmission electron microscopy at liquid helium temperatures for quantum materials

Fundamental quantum phenomena in condensed matter, ranging from correlated electron systems to quantum information processors, manifest their emergent characteristics and behaviors predominantly at low temperatures. This necessitates the use of liquid helium (LHe) cooling for experimental observation. Atomic resolution scanning transmission electron microscopy combined with LHe cooling (cryo-STEM) provides a powerful characterization technique to probe local atomic structural modulations and their coupling with charge, spin and orbital degrees-of-freedom in quantum materials. However, achieving atomic resolution in cryo-STEM is exceptionally challenging, primarily due to sample drifts arising from temperature changes and noises associated with LHe bubbling, turbulent gas flow, etc. In this work, we demonstrate atomic resolution cryo-STEM imaging at LHe temperatures using a commercial side-entry LHe cooling holder. Firstly, we examine STEM imaging performance as a function of He gas flow rate, identifying two primary noise sources: He-gas pulsing and He-gas bubbling. Secondly, we propose two strategies to achieve low noise conditions for atomic resolution STEM imaging: either by temporarily suppressing He gas flow rate using the needle valve or by acquiring images during the natural warming process. Lastly, we show the applications of image acquisition methods and image processing techniques in investigating structural phase transitions in Cr 2 Ge 2 Te 6 , CuIr 2 S 4 , and CrCl 3 . In conclusion, our findings represent an advance in the field of atomic resolution electron microscopy imaging for quantum materials and devices at LHe temperatures, which can be applied to other commercial side-entry LHe cooling TEM holders.

36 MATERIALS SCIENCE↗

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave↗

py4DSTEM: A Software Package for Four-Dimensional Scanning Transmission Electron Microscopy Data Analysis

Scanning transmission electron microscopy (STEM) allows for imaging, diffraction, and spectroscopy of materials on length scales ranging from microns to atoms. By using a high-speed, direct electron detector, it is now possible to record a full two-dimensional (2D) image of the diffracted electron beam at each probe position, typically a 2D grid of probe positions. These 4D-STEM datasets are rich in information, including signatures of the local structure, orientation, deformation, electromagnetic fields, and other sample-dependent properties. However, extracting this information requires complex analysis pipelines that include data wrangling, calibration, analysis, and visualization, all while maintaining robustness against imaging distortions and artifacts. In this paper, we present py4DSTEM, an analysis toolkit for measuring material properties from 4D-STEM datasets, written in the Python language and released with an open-source license. We describe the algorithmic steps for dataset calibration and various 4D-STEM property measurements in detail and present results from several experimental datasets. We also implement a simple and universal file format appropriate for electron microscopy data in py4DSTEM, which uses the open-source HDF5 standard. We hope this tool will benefit the research community and help improve the standards for data and computational methods in electron microscopy, and we invite the community to contribute to this ongoing project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗