Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “time measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Jarzynski Equality for Conditional Stochastic Work

It has been established that the inclusive work for classical, Hamiltonian dynamics is equivalent to the two-time energy measurement paradigm in isolated quantum systems. However, a plethora of other notions of quantum work has emerged, and thus the natural question arises whether any other quantum notion can provide motivation for purely classical considerations. In the present analysis, we propose the conditional stochastic work for classical, Hamiltonian dynamics, which is inspired by the one-time measurement approach. This novel notion is built upon the change of expectation value of the energy conditioned on the initial energy surface. As main results, we obtain a generalized Jarzynski equality and a sharper maximum work theorem, which account for how non-adiabatic the process is. Our findings are illustrated with the parametric harmonic oscillator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of Impedance Measurement Using Spread Spectrum Time Domain Reflectometry

We evaluate the feasibility of spectral time domain reflectometry (STDR) and spread spectrum time domain reflectometry (SSTDR) as a new modality for impedance measurement to test energized/noisy systems over a very broad frequency spectrum (near dc to gigahertz) as well as multiple channels in parallel. We simulate how the S/SSTDR signal parameters (signal-to-noise ratio (SNR) frequency and length of the pseudo-noise (PN) signals) affect the accuracy and usable frequency band for reflection coefficient and impedance measurement. An initial measurement validation is included. Here, we conclude with a recommendation of what will be required for a viable multichannel impedance (and reflection, transmission coefficient) measurement system for either energized or nonenergized systems, in noisy environments, that can test multiple channels simultaneously.

14 SOLAR ENERGY↗

Measurement of the time-integrated 𝐶⁢𝑃 asymmetry in 𝐷 0 → 𝐾$^{0}_{S}$𝐾$^{0}_{S}$ decays using opposite-side flavor tagging at Belle and Belle II

We measure the time-integrated 𝐶⁢𝑃 asymmetry in 𝐷 0 → 𝐾$^{0}_{S}$𝐾$^{0}_{S}$ decays reconstructed in 𝑒 + ⁢𝑒 − → $c\bar{c}$ events collected by the Belle and Belle II experiments. The corresponding data samples have integrated luminosities of 980 and 428 fb −1 , respectively. To infer the flavor of the 𝐷 0 meson, we exploit the correlation between the flavor of the reconstructed decay and the electric charges of particles reconstructed in the rest of the 𝑒 + ⁢𝑒 − → $c\bar{c}$ event. This results in a sample which is independent from any other previously used at Belle or Belle II. The result, 𝐴 𝐶⁢𝑃 ⁡(𝐷 0 → 𝐾$^{0}_{S}$𝐾$^{0}_{S}$)=(1.3±2.0±0.2)%, where the first uncertainty is statistical and the second systematic, is consistent with previous determinations and with 𝐶⁢𝑃 symmetry.

CP violation↗

DARHT Axis 1 Time-Resolved Injector Energy Measurement

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using electron Linear Induction Accelerators (LIA’s). The strict requirements for flash radiography require a detailed understanding of the LIA’s performance, including precision measurements of the injected electron beam energy. The DARHT Axis 1 injector of produces a 3-4 MeV, 1-2 kA, 80-ns-FWHM electron beam. Injector capacitive monitors (EVACSUM) are summed to give the injector beam energy. Calibration of EVACSUM was last done in 1999 and is needed. In addition, the flatness of the injector drive voltage is controlled by a peaking capacitor in a Blumlien that is charged by the prime power tank. Time resolved measurements are used to optimize the value of this capacitor.

47 OTHER INSTRUMENTATION↗

Lamb Wave Stiffness Characterization of Composites Undergoing Thermal-Mechanical Aging

The introduction of new, advanced composite materials into aviation systems requires a thorough understanding of the long term effects of combined thermal and mechanical loading upon those materials. Analytical methods investigating the effects of intense thermal heating combined with mechanical loading have been investigated. The damage mechanisms and fatigue lives were dependent on test parameters as well as stress levels. Castelli, et al. identified matrix dominated failure modes for out-of-phase cycling and fiber dominated damage modes for in-phase cycling. In recent years, ultrasonic methods have been developed that can measure the mechanical stiffness of composites. To help evaluate the effect of aging, a suitably designed Lamb wave measurement system is being used to obtain bending and out-of-plane stiffness coefficients of composite laminates undergoing thermal-mechanical loading. The system works by exciting an antisymmetric Lamb wave and calculating the velocity at each frequency from the known transducer separation and the measured time-of-flight. The same peak in the waveforms received at various distances is used to measure the time difference between the signals. The velocity measurements are accurate and repeatable to within 1% resulting in reconstructed stiffness values repeatable to within 4%. Given the material density and plate thickness, the bending and out-of-plane shear stiffnesses are calculated from a reconstruction of the dispersion curve. A mechanical scanner is used to move the sensors over the surface to map the time-of-flight, velocity, or stiffnesses of the entire specimen. Access to only one side of the material is required and no immersion or couplants are required because the sensors are dry coupled to the surface of the plate. In this study, the elastic stiffnesses D(sub 11), D(sub 22), A(sub 44), and A(sub 55) as well as time-of-flight measurements for composite samples that have undergone combined thermal and mechanical aging for a duration of 10,000 hours are reported.

Seale, Michael D.↗

Quiet-time electron increases, a measure of conditions in the outer solar system

One possible explanation for quiet-time electron increases, increases in the intensity of 3-12 MeV interplanetary electrons that have been reported by McDonald, Cline and Simnett, is discussed. It is argued that the electrons in quiet-time increases are galactic in origin, but that the observed increases are not the result of any variation in the modulation of these particles in the inner solar system. It is suggested instead that quiet-time increases may occur when more electrons than normal penetrate a modulating region that lies far beyond the orbit of earth. The number of electrons penetrating this region may increase when field lines that have experienced an unusually large random walk in the photosphere are carried by the solar wind out to the region. As evidence for this increased random walk, it is shown that five solar rotations before most of the quiet-time increases there is an extended period when the amplitude of the diurnal anisotropy, as is measured by the Deep River neutron monitor, is relatively low. Five rotations delay time implies that the proposed modulating region lies at approximately 30 AU from the Sun, assuming that the average solar wind speed is constant over this distance at approximately 400 km/sec.

Fisk, L. A.↗

Using GPS Receiver 1PPS Output to Verify Time Stamp Accuracy and Measure Propagation Delay

A simple pulse overlay circuit using a logic OR gate was developed to overlay a precise leading edge 1 pulse per second time reference marker from a global positioning system receiver onto a non-return -to- zero-level pulse code modulation telemetry data stream to validate time stamp accuracy and measure propagation delay in telemetry equipment.

time stamp offset↗

Standardizing reverberation-measured Mg II time-lag quasars, by using the radius–luminosity relation, and constraining cosmological model parameters

ABSTRACT We use 78 reverberation-measured Mg II time-lag quasars (QSOs) in the redshift range 0.0033 ≤ z ≤ 1.89 to constrain cosmological parameters in six different cosmological models. The basis of our method is the use of the radius–luminosity or R−L relation to standardize these 78 Mg II QSOs. In each cosmological model, we simultaneously determine R−L relation and cosmological model parameters, thus avoiding the circularity problem. We find that the R−L relation parameter values are independent of the cosmological model used in the analysis, thus, establishing that current Mg II QSOs are standardizable candles. Cosmological constraints obtained using these QSOs are significantly weaker than, but consistent with, those obtained from a joint analysis of baryon acoustic oscillation (BAO) observations and Hubble parameter [H(z)] measurements. So, we also analyse these QSOs in conjunction with the BAO + H(z) data and find cosmological constraints consistent with the standard spatially flat ΛCDM model as well as with mild dark energy dynamics and a little spatial curvature. A larger sample of higher quality reverberation-measured QSOs should have a smaller intrinsic dispersion and so should provide tighter constraints on cosmological parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Intermediate term frequency measurements with the HP computing counter in the USNO clock time system

High precision frequency measurements with various integration times can be made with conventional counters by using variable gate times. The Hewlett-Packard (HP) computing counter allows such measurements over a wide range of frequencies and measurement times. This instrument can also convert period measurements into frequency by means of its arithmetic capabilities: The program library contains programs to facilitate frequency stability measurements in the most direct and convenient way. This method was used as the basis for all time scale computations, until requirements for highest resolution justified the development of an automatic data acquisition system. The phase measurements are now being made with the HP computing counter (with time interval plug-in unit) under program control from the HP System Programmer.

Winkler, G. M. R.↗

Effect of Time Window and Spectral Measurement Options on Empirical Green’s Function Analysis Using DAS Array and Seismic Stations

The recorded seismic waveform is a convolution of event source term, path term, and station term. Removing high-frequency attenuation due to path effect is a challenging problem. Empirical Green’s function (EGF) method uses nearly collocated small earthquakes to correct the path and station terms for larger events recorded at the same station. However, this method is subject to variability due to many factors. Here, we focus on three events that were well recorded by the seismic network and a rapid response distributed acoustic sensing (DAS) array. Using a suite of high-quality EGF events, we assess the influence of time window, spectral measurement options, and types of data on the spectral ratio and relative source time function (RSTF) results. Increased number of tapers (from 2 to 16) tends to increase the measured corner frequency and reduce the source complexity. Extended long time window (e.g., 30 s) tends to produce larger variability of corner frequency. The multitaper algorithm that simultaneously optimizes both target and EGF spectra produces the most stable corner-frequency measurements. The stacked spectral ratio and RSTF from the DAS array are more stable than two nearby seismic stations, and are comparable to stacked results from the seismic network, suggesting that DAS array has strong potential in source characterization.

58 GEOSCIENCES↗

Non-Idealities in Lab-Scale Kinetic Testing: A Theoretical Study of a Modular Temkin Reactor

The Temkin reactor can be applied for industrial relevant catalyst testing with unmodified catalyst particles. It was assumed in the literature that this reactor behaves as a cascade of continuously stirred tank reactors (CSTR). However, this assumption was based only on outlet gas composition or inert residence time distribution measurements. The present work theoretically investigates the catalytic CO2 methanation as a test case on different catalyst geometries, a sphere, and a ring, inside a single Temkin reaction chamber under isothermal conditions. Axial gas-phase species profiles from detailed computational fluid dynamics (CFD) are compared with a CSTR and 1D plug-flow reactor (PFR) model using a sophisticated microkinetic model. In addition, a 1D chemical reactor network (CRN) model was developed, and model parameters were adjusted based on the CFD simulations. Whereas the ideal reactor models overpredict the axial product concentrations, the CRN model results agree well with the CFD simulations, especially under low to medium flow rates. This study shows that complex flow patterns greatly influence species fields inside the Temkin reactor. Although residence time measurements suggest CSTR-like behavior, the reactive flow cannot be described by either a CSTR or PFR model but with the developed CRN model.

Wehinger, Gregor D. (ORCID:0000000217743391)↗

Strong and Weak C P Tests in Sequential Decays of Polarized Σ 0 Hyperons

The J / ψ , ψ ( 3686 ) → Σ 0 Σ ¯ 0 processes and subsequent decays are studied using the world’s largest J / ψ and ψ ( 3686 ) data samples collected with the BESIII detector. The parity-violating decay parameters of the decays Σ 0 → Λ γ and Σ ¯ 0 → Λ ¯ γ , α Σ 0 = − 0.0017 ± 0.0021 ± 0.0018 and α ¯ Σ 0 = 0.0021 ± 0.0020 ± 0.0022 , are measured for the first time. The strong C P symmetry is tested in the decays of the Σ 0 hyperons for the first time by measuring the asymmetry A C P Σ = α Σ 0 + α ¯ Σ 0 = ( 0.4 ± 2.9 ± 1.3 ) × 10 − 3 . The weak C P test is performed in the subsequent decays of their daughter particles Λ and Λ ¯ . Also for the first time, the transverse polarizations of the Σ 0 hyperons in J / ψ and ψ ( 3686 ) decays are observed with opposite directions, and the ratios between the S -wave and D -wave contributions of the J / ψ , ψ ( 3686 ) → Σ 0 Σ ¯ 0 decays are obtained. These results are crucial to understand the decay dynamics of the charmonium states and the production mechanism of the Σ 0 − Σ ¯ 0 pairs. Published by the American Physical Society 2024

Physics↗

Improved temporal resolution in ultrafast electron diffraction measurements through THz compression and time-stamping

We present an experimental demonstration of ultrafast electron diffraction (UED) with THz-driven electron bunch compression and time-stamping that enables UED probes with improved temporal resolution. Through THz-driven longitudinal bunch compression, a compression factor of approximately four is achieved. Moreover, the time-of-arrival jitter between the compressed electron bunch and a pump laser pulse is suppressed by a factor of three. Simultaneously, the THz interaction imparts a transverse spatiotemporal correlation on the electron distribution, which we utilize to further enhance the precision of time-resolved UED measurements. We use this technique to probe single-crystal gold nanofilms and reveal transient oscillations in the THz near fields with a temporal resolution down to 50 fs. These oscillations were previously beyond reach in the absence of THz compression and time-stamping.

43 PARTICLE ACCELERATORS↗

High sensitivity pump–probe measurements of magnetic, thermal, and acoustic phenomena with a spectrally tunable oscillator

We describe an optical pump/probe system for sensitive measurements of time-resolved optical measurements of material dynamics. The instrument design is optimized for time-resolved magneto-optic Kerr effect (TR-MOKE) measurements of dynamics in magnetic materials. The system also allows for time-domain thermoreflectance (TDTR) measurements of thermal transport properties and picosecond acoustic measurements of film thickness and/or elastic constants. The system has several advantages over the conventional designs for TRMOKE and/or TDTR systems. Measurements of pump-induced changes to the probe beam intensity are shot-noise limited. The system’s design allows for MOKE and/or thermoreflectance measurements of both sides of a sample. Pumping and probing the sample on opposite sides allows nanoscale flash diffusivity measurements of transport properties. The wavelengths of the pump and probe beams are straightforward to tune between 350–525 nm and 690–1050 nm. A tunable wavelength allows for optical resonances in a wide array of materials to be excited and/or probed. Finally, the setup is calibrated to allow for the real and imaginary components of Kerr signals to be separately quantified.

47 OTHER INSTRUMENTATION↗

Search for CME in U+U and Au+Au collisions in STAR with different approaches of handling backgrounds

We report the chiral magnetic effect (CME) refers to charge separation along a strong magnetic field between left- and right-handed quarks, caused by interactions with topological gluon fields from QCD vacuum fluctuations. We present two approaches to handle the dominant elliptic flow (v 2 ) background in the three-particle correlator (Δγ 112 ), sensitive to CME. In the first approach, we present the Δγ 112 and Δγ 123 measurements in U+U and Au+Au collisions. While hydrodynamic simulations including resonance decays and local charge conservation predict that Δγ 112 scaled by N part /ν 2 will be similar in U+U and Au+Au collisions, the projected B-field exhibits a distinct difference between the two systems and with varying N part . Therefore, U+U and Au+Au collisions provide configurations with different expectations for both CME signal and background. Moreover, the three-particle observable Δγ 123 scaled by N part /ν 3 provide baseline measurement for only the background. In the second approach, we handle the ν 2 background by measuring Δγ 112 with respect to the planes of spectators measured by Zero Degree Calorimeters and participants measured by Time Projection Chamber. These measurements contain different amounts of contributions from CME signal (along B-field, due to spectators) and ν 2 background (determined by the participant geometry). With the two Δγ 112 measurements, the possible CME signal and the background contribution can be determined. We report such a measurement in Au+Au collisions at $\sqrt{s_{NN}}$ = 27GeV with the newly installed event plane detector, and report the new findings in U+U system where the spectator-participant plane correlations are expected to differ from those in Au+Au collisions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mapping of lanthanide-tagged proteins on western blot paper using microextraction-inductively coupled plasma-mass spectrometry

A microextraction (ME) sampling system, paired with inductively coupled plasma-mass spectrometry (ICP-MS), was employed to spatially analyze proteins tagged with lanthanum (La), gadolinium (Gd), or terbium (Tb) on the surface of western blot paper. The proteins were covalently tagged, separated via gel electrophoresis, and transferred to western blot paper for analysis by ME-ICP-MS. The ME-ICP-MS method enables the direct sampling of the tagged species on the western blot paper, without any sample preparation. Traditionally, the tagged analyte would need to be stained, excised, and digested to be analyzed by ICP-MS for its elemental and isotopic characterization. Preliminary detection limits for the ME-ICP-MS method applied to western blot paper were established to be 564, 54, and 2.5 fg for La, Gd, and Tb, respectively. The developed ME-ICP-MS method was compared to laser ablation (LA) ICP-MS, another direct solid sampling technique; it was readily determined that ME-ICP-MS can effectively map the elemental constituents on the western blot paper with comparable analysis time and measurement sensitivity. The analysis time per 2 × 4 mm extraction is ∼1 minute; if protein spots are directly targeted (rather than systematically mapping the entire blot paper), the analysis time per protein spot is ∼1 min. This developed method proved to be fast, effective, and accessible for correlating protein molecular weight with the detection of the inorganic tagant. The ME-ICP-MS approach could be widely applicable in research areas that involve metal-tagged protein bioconjugates, such as in the development of diagnostic and therapeutic agents and other biochemical probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Instrumentation development and testing of a wind turbine blade for sub-scale wake studies

Wind turbine blade aerodynamics and the resulting wake flow are complex, and wind tunnel testing of these flows can provide critical insight. The data from such tests are also valuable for validation of numerical models. For experiments using sub-scale turbines to be useful, the blade aerodynamics and wakes must exhibit the important features observed in utility-scale turbine flows. In this work, ~1 m blades designed to produce physics relevant to larger scale turbines were manufactured and affixed to an existing turbine. One of the blades was instrumented for blade surface pressure measurements. Time-dependent surface pressure measurements coupled with instantaneous measurements of the inflow with Cobra probes and the wake with particle image velocimetry allowed for characterization of the inflow, blade flow, and near wake. The results demonstrate that the instrumentation was effective in characterizing the blade loading and the flow field. For the one test case discussed in this paper, the measurements of inflow, blade loading, and wake properties facilitate understanding of the wake's behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗