Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tank testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Data report for tests on the heat transfer effects of the 0.0175 scale Rockwell International Space Shuttle Vehicle model 22-OT in the AEDC 50 inch B wind tunnel (0H4B), volume 1

Results of wind tunnel heat transfer tests of 0.0175-scale Rockwell International Space Shuttle Vehicle configurations for orbiter alone, tank alone, and orbiter plus external tank are presented. Body flap shielding of SSME's during simulated entry was investigated. The tests were conducted at Mach 8 for thirteen Reynolds number.

Foster, T. F.↗

Sinda/Fluint Stratfied Tank Modeling

A general purpose SINDA/FLUINT (S/F) stratified tank model was created and used to simulate the Ksite1 LH2 liquid self-pressurization tests as well as axial jet mixing within the liquid region of the tank. The S/F model employed the use of stratified layers, i.e. S/F lumps, in the vapor ullage as well as in the liquid region. The model was constructed to analyze a general purpose stratified tank that could incorporate the following features: Multiple or singular lumps in the liquid and vapor regions of the tank, Real gases (also mixtures) and compressible liquids, Venting, pressurizing, and draining, Condensation and evaporation/boiling, Wall heat transfer, Elliptical, cylindrical, and spherical tank geometries. Extensive user logic was used to allow for tailoring of the above features to specific cases. Most of the code input for a specific case could be done through the Registers Data Block.

Sinda/Fluint↗

Microgravity Geyser and Flow Field Prediction

Modeling and prediction of flow fields and geyser formation in microgravity cryogenic propellant tanks was investigated. A computational simulation was used to reproduce the test matrix of experimental results performed by other investigators, as well as to model the flows in a larger tank. An underprediction of geyser height by the model led to a sensitivity study to determine if variations in surface tension coefficient, contact angle, or jet pipe turbulence significantly influence the simulations. It was determined that computational geyser height is not sensitive to slight variations in any of these items. An existing empirical correlation based on dimensionless parameters was re-examined in an effort to improve the accuracy of geyser prediction. This resulted in the proposal for a re-formulation of two dimensionless parameters used in the correlation; the non-dimensional geyser height and the Bond number. It was concluded that the new non-dimensional geyser height shows little promise. Although further data will be required to make a definite judgement, the reformulation of the Bond number provided correlations that are more accurate and appear to be more general than the previously established correlation.

Hochstein, J. I.↗

Correlation of inert gas hollow cathode performance

A use of the inert gases argon and xenon as possible alternatives to mercury and cesium is being considered for electrical propulsion applications. Operation up to 200 hours has been demonstrated for hollow cathodes employing argon as propellant. A description is presented of an investigation which has been conducted to obtain basic information for an improvement of hollow cathode performance with inert gases. Neutralizer tests were conducted in a 1.2-m diameter vacuum tank, with a 15-cm multipole thruster. Progress was achieved towards the goal of a generalized description of hollow cathode performance. Extrapolation of the erosion based upon a 200-hour endurance test predicts an ultimate lifetime of 1400 to 10,000 hours.

Rehn, L.↗

Computational Analyses of Pressurization in Cryogenic Tanks

A comprehensive numerical framework utilizing multi-element unstructured CFD and rigorous real fluid property routines has been developed to carry out analyses of propellant tank and delivery systems at NASA SSC. Traditionally CFD modeling of pressurization and mixing in cryogenic tanks has been difficult primarily because the fluids in the tank co-exist in different sub-critical and supercritical states with largely varying properties that have to be accurately accounted for in order to predict the correct mixing and phase change between the ullage and the propellant. For example, during tank pressurization under some circumstances, rapid mixing of relatively warm pressurant gas with cryogenic propellant can lead to rapid densification of the gas and loss of pressure in the tank. This phenomenon can cause serious problems during testing because of the resulting decrease in propellant flow rate. With proper physical models implemented, CFD can model the coupling between the propellant and pressurant including heat transfer and phase change effects and accurately capture the complex physics in the evolving flowfields. This holds the promise of allowing the specification of operational conditions and procedures that could minimize the undesirable mixing and heat transfer inherent in propellant tank operation. In our modeling framework, we incorporated two different approaches to real fluids modeling: (a) the first approach is based on the HBMS model developed by Hirschfelder, Beuler, McGee and Sutton and (b) the second approach is based on a cubic equation of state developed by Soave, Redlich and Kwong (SRK). Both approaches cover fluid properties and property variation spanning sub-critical gas and liquid states as well as the supercritical states. Both models were rigorously tested and properties for common fluids such as oxygen, nitrogen, hydrogen etc were compared against NIST data in both the sub-critical as well as supercritical regimes.

Ahuja, Vineet↗

Space shuttle: Static surface pressures of the 0.004 scale 049 orbiter in the launch configuration

Wing and lower body surface static pressure data for the space shuttle 049 orbiter while in the launch configuration were obtained. The purpose of the test was to determine the optimum incidence position of the orbiter relative to the hydrogen-oxygen (HO) tank and the optimum radial position of the solid rocket motors (SRM) on the HO tank. The orbiter was mounted on the HO tank at incidence angles of 0 and -1.5 degrees to determine the optimum incidence position. The SRM boosters were tested at radial positions of 75, 90, and 135 degrees on the HO tank to determine their optimum position with respect to the loads imposed on the orbiter. The test was conducted in the tunnel over a Mach number range of 0.6 to 4.96. Angle of attack was varied from -8 to +8 degrees at zero degree angle of sideslip, and at sideslip angles varying from -6 to +6 degrees at zero degree angle of attack.

Buchholz, R. E.↗

Initial testing of wave energy powered UV-C LED anti-biofouling system (CRADA 523)

3newable is requesting technical assistance for laboratory testing at the Marine and Coastal Research (MCRL) Laboratory of a UV-C LED anti-biofouling system. Ocean observing sensors provide critical data sources from deployed buoys and other platforms at sea. However, in addition to the availability of reliable power sources, biofouling of sensors and instruments is a limiting factor for operation and maintenance of deployed instruments. In collaboration with the Woods Hole Oceanographic Institute Ocean Observatories Initiative, 3newable has developed a novel solution to overcome these challenges and extend the deployment period of buoy-mounted sensors. The 3newable system co-locates wave energy converters to supply UV-C LED anti-biofouling units on powered buoy arrays. MCRL staff will implement an experiment to evaluate the efficacy of 3newable’s device under test for inhibiting growth of organisms on test coupons in a flow through seawater tank.

42 ENGINEERING↗

Outlet baffles: Effect on liquid residuals from zero-gravity draining of hemispherically ended cylinders

An experimental investigation was conducted to study the relative effectiveness of various outlet baffles in reducing liquid residuals resulting from the draining of hemispherically ended cylindrical tanks in a weightless environment. Three different baffles were employed. The relative effectiveness of each baffle was determined by comparing the results obtained, in the form of liquid residuals, with results for an unbaffled tank. Data indicate that all the baffles tested reduced residuals. Reductions betweem 10 and 60 percent were obtained, depending on baffle geometry and outlfow Weber number.

Symons, E. P.↗

Performance of a 12-coil superconducting bumpy torus magnet facility

The bumpy torus facility consists of 12 superconducting coils, each 19 cm i.d. and capable of 3.0 teslas on their axes. The coils are equally spaced around a toroidal array with a major diameter of 1.52 m, and are mounted with the major axis of the torus vertical in a single vacuum tank 2.6 m in diameter. Final shakedown tests of the facility mapped out its magnetic, cryogenic, vacuum, mechanical, and electrical performance. The facility is now ready for use as a plasma physics research facility. A maximum magnetic field on the magnetic axis of 3.23 teslas was held for a period of more than sixty minutes without a coil normalcy. The design field was 3.00 teslas. The steady-state liquid helium boil-off rate was 87 liters per hour of liquid helium without the coils charged. The coil array was stable when subjected to an impulsive loading, even with the magnets fully charged. When the coils were charged to a maximum magnetic field of 3.35 teslas, the system was driven normal without damage.

Roth, J. R.↗

Reuseable lightweight modular multi-layer insulation for space shuttle

The adaptation of the Self Evacuating Multilayer Insulation System to the space shuttle orbiter liquid hydrogen tanks was investigated. Small scale material screening tests and subscale panel tests demonstrated the potential of the insulation to withstand the anticipated 100 flight cycles. The composition of the material and the process for producing the finished insulation are described. Results of the various tests to determine the durability of the material are presented.

Burr, K. F.↗

Performance of a 12-coil superconducting 'bumpy torus' magnet facility.

The NASA-Lewis 'bumpy torus' facility consists of 12 superconducting coils, each 19 cm ID and capable of 3.0 tesla on their axes. The coils are equally spaced around a toroidal array with a major diameter of 1.52 m, and are mounted with the major axis of the torus vertical in a single vacuum tank 2.6 m in diameter. Final shakedown tests of the facility mapped out its magnetic, cryogenic, vacuum, mechanical, and electrical performance. The facility is now ready for use as a plasma physics research facility. A maximum magnetic field on the magnetic axis of 3.23 teslas has been held for a period of more than sixty minutes without a coil normalcy.

Roth, J. R.↗

Advanced supersonic technology fuel tank sealants

Status of the fuel tank simulation and YF-12A flight tests utilizing a fluorosilicone sealant is described. New elastomer sealant development is detailed, and comparisons of high and low temperature characteristics are made to baseline fluorosilicone sealants.

Rosser, R. W.↗

Prototype solar heating and combined heating and cooling systems

Schedules and technical progress in the development of eight prototype solar heating and combined solar heating and cooling systems are reported. Particular emphasis is given to the analysis and preliminary design for the cooling subsystem, and the setup and testing of a horizontal thermal energy storage tank configuration and collector shroud evaluation.

Source record↗

Pressure-Decay Measurements Improve Bubble-Point Test

Technique reduces by factor of about 100 minimum detectable flaw size in bubble-point test. By measuring rate of slow leakage, flaws as small as about 10-4 in. 2 (0.06mm2) are detected. Since technique does not require observation of screen, tests run on screens already installed inside tanks and pipes.

Silkey, J. S.↗