Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system frequency response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Three-Dimensional Vibration Isolator for Suppressing High-Frequency Responses for Sage III Contamination Monitoring Package (CMP)

The Stratospheric Aerosol and Gas Experiment (SAGE) III - International Space Station (ISS) instrument will be used to study ozone, providing global, long-term measurements of key components of the Earth's atmosphere for the continued health of Earth and its inhabitants. SAGE III is launched into orbit in an inverted configuration on SpaceX;s Falcon 9 launch vehicle. As one of its four supporting elements, a Contamination Monitoring Package (CMP) mounted to the top panel of the Interface Adapter Module (IAM) box experiences high-frequency response due to structural coupling between the two structures during the SpaceX launch. These vibrations, which were initially observed in the IAM Engineering Development Unit (EDU) test and later verified through finite element analysis (FEA) for the SpaceX launch loads, may damage the internal electronic cards and the Thermoelectric Quartz Crystal Microbalance (TQCM) sensors mounted on the CMP. Three-dimensional (3D) vibration isolators were required to be inserted between the CMP and IAM interface in order to attenuate the high frequency vibrations without resulting in any major changes to the existing system. Wire rope isolators were proposed as the isolation system between the CMP and IAM due to the low impact to design. Most 3D isolation systems are designed for compression and roll, therefore little dynamic data was available for using wire rope isolators in an inverted or tension configuration. From the isolator FEA and test results, it is shown that by using the 3D wire rope isolators, the CMP high-frequency responses have been suppressed by several orders of magnitude over a wide excitation frequency range. Consequently, the TQCM sensor responses are well below their qualification environments. It is indicated that these high-frequency responses due to the typical instrument structural coupling can be significantly suppressed by a vibration passive control using the 3D vibration isolator. Thermal and contamination issues were also examined during the isolator selection period for meeting the SAGE III-ISS instrument requirements.

Li, Y.↗

SC-228 Inclusion of DAA Warning Alert for TCAS Interoperability

This white paper summarizes NASA research results that have informed Special Committee 228 (SC-228) discussions and decisions regarding the inclusion of a warning-level alert within the detect and avoid (DAA) alerting structure for unmanned aircraft systems (UAS). For UAS, the removal of the pilot from onboard the aircraft has eliminated the ability of the ground-based pilot in command (PIC) to use out-the-window visual information to make judgments about a potential threat of a loss of well clear with another aircraft. As a result, the DAA traffic display will be the primary source of information that the PIC can use to execute the three primary well clear functions: 1) detect a potential loss of well clear, 2) determine a resolution maneuver, and 3) upload that maneuver to the aircraft via the ground control station (GCS). In addition, pilots are required to coordinate with air traffic control (ATC) prior to maneuvering off of their approved flight plan. In determining an appropriate resolution maneuver to avoid a loss of well clear, the PIC must decide both when and how to maneuver, and both the timeliness and the accuracy (i.e., correctness) of the maneuver are critical to reducing the likelihood and/or severity of a loss of well clear. Alerting information is one of three critical components of the DAA display, along with traffic information elements (e.g., relative heading, speed and altitude) and maneuver guidance. Alerting information and maneuver guidance, in particular, have been found to have a significant impact, both statistically and practically, on pilots' ability to avoid and minimize the severity of losses of well clear While all three display components are key to pilots performing the traffic avoidance task of remaining well clear, in general, alerting information provides crucial information about when a resolution maneuver is required while maneuver guidance assists the pilot in determining how best to maneuver. A fundamental task of the DAA alerting system is to provide critical timing information to the pilot about the potential for a loss of well clear with another aircraft. This is done by employing both temporal and spatial thresholds that indicate to the pilot the likelihood and imminence of a loss of well clear. The design of the DAA alerting thresholds is a balancing act between eliciting the desired pilot response in real loss of well clear threat events and reducing excessive, unnecessary, and/or uncoordinated UAS maneuvering within the air traffic environment; larger thresholds, both spatially and temporally, may increase the likelihood of a pilot avoiding a loss of well clear, but it can also increase the frequency of maneuvering - especially in cases where a maneuver is not actually needed to maintain well clear. A series of human in the loop (HITL) simulations have been conducted as part of NASA's Unmanned Aircraft Systems (UAS) Integration in the National Airspace System (NAS) project. The purpose of these HITLs has been to provide empirical results in order to inform development of the minimum human-machine interface requirements for the DAA system. This white paper will present those results which provide evidence of a human performance benefit (in terms of response times and ability to remain well clear of other aircraft) of the DAA warning alert both with and without a collision avoidance system on board the aircraft.

TCAS interoperability↗

Effect of low-frequency ambient magnetic fields on the control unit and RF head of a commercial SQUID magnetometer

The control unit and RF head of the SHE model 330XRFSQUID system are shown to be sensitive to ambient ac magnetic fields below 1 HZ, which cause the appearance of false signals corresponding to a magnetometer signal of 0.000001 phi(0) per gauss of field applied. The control unit shows a sensitivity that is linear with frequency, suggesting that the signal is generated by Faraday induction. In contrast, the RF head response is independent of frequency and shows a strong second-harmonic coversion. This response may be due to the magnetic field sensitivity of the ferrite core inductor in the tuned amplifier of the RF head. These signals induced by ambient fields are a potential source of error in Stanford's Relativity Gyroscope experiment, which uses SQUID's on board a rolling satellite as part of the gyroscope readout system. The extent of the magnetic field sensitivity in these components necessitates the use of additional magnetic shielding aboard the satellite.

Marcus, C. M.↗

Low-cost gradient amplifiers for small MRI systems

Here, we describe low-cost gradient amplifiers for small MRI systems, such as those based on small/medium permanent magnets. The requirements for MRI gradient amplifiers are quite similar to those of modestly priced audio stereo power amplifiers. Such amplifiers for sound service can be modified to be DC coupled, extending their response down to zero frequency, as needed for MRI gradient service. We describe such modifications to one unit (Samson Servo 600) and mention a commercially available modification of another. The 600 is capable of an output greater than ±8 A and ±60 V, much greater than our needs for a greenhouse MRI. Audio amplifiers can be used this way as controlled voltage (CV) gradient amplifiers, with acceptable performance because the gradient coils typically have short L/R time constants. Superior performance can be had by using a controlled current (CC) “front end”; the circuit of our simple front end is included. The complete 3-axis CC system costs about $1200.

47 OTHER INSTRUMENTATION↗

Steady-state dynamic behavior of an auxiliary bearing supported rotor system

This paper investigates the steady-state responses of a rotor system supported by auxiliary bearings in which there is a clearance between the rotor and the inner race of the bearing. A simulation model based upon the rotor of a production jet engine is developed and its steady-state behavior is explored over a wide range of operating conditions for various parametric configurations. Specifically, the influence of rotor imbalance, support stiffness, and damping is studied. It is found that imbalance may change the rotor responses dramatically in terms of frequency contents at certain operating speeds. Subharmonic responses of 2nd order through 10th order are all observed except the 9th order. Chaotic phenomenon is also observed. Jump phenomena (or double-valued responses) of both hard-spring type and soft-spring type are shown to occur at low operating speeds for systems with low auxiliary bearing damping or large clearance even with relatively small imbalance. The effect of friction between the shaft and the inner race of the bearing is also discussed.

Xie, Huajun↗

Model Based Predictive Control for Frequency Support in Multi-port Autonomous Reconfigurable Solar Plants

Primary frequency support functionality can be an added advantage for any new grid integrated power electronics resource. With increased penetration of power electronics resources, inertial and primary frequency response capabilities are decreasing. In this research paper, an advanced model-based predictive control (MBPC) algorithm for providing frequency support to a new topology of integrated photovoltaic(PV), batterybased energy storage systems (ESS), and high-voltage direct current (HV dc) systems called multi-port autonomus reconfigurable solar (MARS) plants is based on the synchronverter-based control. The simulation of MARS-HV dc system with proposed control strategy is simulated and validated for MARS connected to low short circuit ratio (SCR) grids in PSCAD/EMTDC simulation environment. The control algorithm proposed showcases better performance in terms of frequency nadir improvement and frequency steady state improvemnt with respect to no frequency control.

Marthi, Phani Ratna Vanamali↗

Design of the PIP-II 650 MHz Low Beta Cryomodule

The Proton Improvement Plan II (PIP-II) that will be installed at Fermilab is the first U.S. accelerator project that will have significant contributions from international partners. CEA joined the international collaboration in 2018, and is responsible of the 650 MHz low-beta section made of 9 cryomodules, with the design of the cryostat (i.e the cryomodule without the cavities, the power couplers and the frequency tuning systems) and the manufacturing of its components, the assembly and tests of the pre-production cryomodule and the 9 series ones. This paper will present the design of the 650 MHz low-beta cryomodule.

43 PARTICLE ACCELERATORS↗

Lower Snake River Dams Contribution to Grid Services

Hydroelectric generation and water storage have long been components of the clean energy mix, providing both reliable steady output and operational flexibility. As variable renewable energy sources such as wind and solar increasingly replace traditional generation, the role of all flexible resources—including hydropower—in balancing supply and demand continues to evolve. This study examined the contribution of the Lower Snake River (LSR) Dam plants to Bonneville Power Administration grid services in maintaining power system reliability within the Western Interconnection. By analyzing publicly available data, the study evaluated various reliability services through performance metrics including energy capacity, balancing and ramping, voltage and reactive power support, frequency response, and transmission impact. Results indicated that the LSR plants deliver services as expected based on their size, contributing to the balancing process, ramping capabilities, and operational reserves, particularly during peak load conditions and weather events, while also providing measurable frequency and voltage support to the grid.

13 HYDRO ENERGY↗

Finite Element Analysis of the TRUST Nonlinear Dynamics Testbed

This paper builds on prior work conducted within the Los Alamos National Laboratory (LANL) Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) program. Specifically, it builds on finite element (FE) modeling efforts for the TRUST program’s Nonlinear Dynamics (ND) testbed. Historically, the FE model for the ND testbed has exclusively utilized a Lanczos eigensolver that linearly extracts the system’s natural frequencies. This paper investigates the Abaqus 2024’s explicit dynamic solver, which implements a central difference explicit solver. The central difference method used in Abaqus can capture nonlinear material responses in structural dynamic simulations making it suitable for the ND FE model.

42 ENGINEERING↗

Concepts for a theoretical and experimental study of lifting rotor random loads and vibrations. Phase 5C: Development of experimental methods

Test equipment which was built and the calibration tests are described. The test equipment consists of a two-bladed rotor of 16-in. diameter, the blades of which are elastically hinged in flapping. The feathering shaft of the blades can be harmonically rotated with the help of a cam mechanism located inside the hollow rotor shaft. The frequency range measured in the rotating system can be adjusted between 0 and 80 cps and the rotor speed between 0 and 40 cps. The test equipment is for measuring the flapping response of the blades to harmonic feathering excitation.

Hohenemser, K. H.↗

Optical detection of pulsed surface particle displacements

The detection of acoustic surface wave pulses by a wideband differential interferometric laser technique which is insensitive to low frequency noise is described. System bandwidth is determined by the relationship between acoustic wavelength and the variable spacing between two laser probe beams focused on the solid surface which supports the waves. Response to an ideal step function displacement is analyzed and experimental measurements of gated 2.5 MHz pulses generated on an aluminized pyrex plate are discussed.

Zewekh, P. S.↗

In Search of a Visual-cortical Describing Function: a Summary of Work in Progress

The thrust of the present work is to explore the utility of using a sum of sinusoids (seven or more) to obtain an evoked response and, furthermore, to see if the response is sensitive to changes in cognitive processing. Within the field of automatic control system technology, a mathematical input/output relationship for a sinusoidally stimulated nonlinear system is defined as describing function. Applying this technology, sum of sines inputs to yield describing functions for the visual-cortical response have been designed. What follows is a description of the method used to obtain visual-cortical describing functions. A number of measurement system redesigns were necessary to achieve the desired frequency resolution. Results that guided and came out of the redesigns are presented. Preliminary results of stimulus parameter effects (average intensity and depth of modulation) are also shown.

Junker, A. M.↗

Low-frequency dynamics of quasi-geostrophic waves in a midlatitude channel and the effects of tropical influence

Both zonal mean flow and stationary waves in the stratosphere have large variabilities from month to month and from year to year. One plausible mechanism that can account for these variabilities is the interaction between the forced stationary waves and the mean zonal flow. Given the large energy source contained in the stationary waves which are forced in the lower atmosphere, they are probably responsible for inducing the bulk of the variability in the mean flow in the stratosphere. Variability in the mean flow can in turn produce variability in the stationary wave amplitudes due to the possible sensitivity of wave response in the stratosphere to the configuration of the wave guide determined by the mean flow. The likely causes for the low-frequency variability of the stationary waves-mean flow system in extratropical latitudes are assessed. The causes of variability are divided into internal and external ones. Internal mechanisms include transition between equilibria and vacillation cycles, while mechanisms external to the midlatitude system include eddy heat and momentum fluxes from the tropics and the Hadley circulation forced in the tropics.

Tung, K. K.↗

A microprocessor based anti-aliasing filter for a PCM system

Described is the design and evaluation of a microprocessor based digital filter. The filter was made to investigate the feasibility of a digital replacement for the analog pre-sampling filters used in telemetry systems at the NASA Ames-Dryden Flight Research Facility (DFRF). The digital filter will utilize an Intel 2920 Analog Signal Processor (ASP) chip. Testing includes measurements of: (1) the filter frequency response and, (2) the filter signal resolution. The evaluation of the digital filter was made on the basis of circuit size, projected environmental stability and filter resolution. The 2920 based digital filter was found to meet or exceed the pre-sampling filter specifications for limited signal resolution applications.

Morrow, D. C.↗

Modulation transfer function measurement technique for small-pixel detectors

A modulation transfer function (MTF) measurement technique suitable for large-format, small-pixel detector characterization has been investigated. A volume interference grating is used as a test image instead of the bar or sine wave target images normally used. This technique permits a high-contrast, large-area, sinusoidal intensity distribution to illuminate the device being tested, avoiding the need to deconvolve raw data with imaging system characteristics. A high-confidence MTF result at spatial frequencies near 200 cycles/mm is obtained. We present results at several visible light wavelengths with a 6.8-micron-pixel CCD. Pixel response functions are derived from the MTF results.

Marchywka, Mike↗

A Patch Density Recommendation based on Convergence Studies for Vehicle Panel Vibration Response resulting from Excitation by a Diffuse Acoustic Field

Producing fluid structural interaction estimates of panel vibration from an applied pressure field excitation are quite dependent on the spatial correlation of the pressure field. There is a danger of either over estimating a low frequency response or under predicting broad band panel response in the more modally dense bands if the pressure field spatial correlation is not accounted for adequately. It is a useful practice to simulate the spatial correlation of the applied pressure field over a 2d surface using a matrix of small patch area regions on a finite element model (FEM). Use of a fitted function for the spatial correlation between patch centers can result in an error if the choice of patch density is not fine enough to represent the more continuous spatial correlation function throughout the intended frequency range of interest. Several patch density assumptions to approximate the fitted spatial correlation function are first evaluated using both qualitative and quantitative illustrations. The actual response of a typical vehicle panel system FEM is then examined in a convergence study where the patch density assumptions are varied over the same model. The convergence study results illustrate the impacts possible from a poor choice of patch density on the analytical response estimate. The fitted correlation function used in this study represents a diffuse acoustic field (DAF) excitation of the panel to produce vibration response.

Smith, Andrew↗

Mitigating Grazing Flow Impedance Eduction Errors in Additively Manufactured Porous Liners

Additively manufactured porous metamaterials, including triply periodic minimal surface (TPMS) cores, are promising candidates for aeroengine liners but often behave as extended-reacting treatments under grazing flow. Standard impedance eduction procedures assume locally-reacting behavior and can yield physically inconsistent results for such materials. This study evaluates internal partitions (thin solid walls inserted at regular intervals along the liner’s streamwise extent) as a means of suppressing internal streamwise propagation to improve eduction consistency. Six TPMS configurations were tested in the NASA Langley Grazing Flow Impedance Tube (GFIT) at partition spacings of 4′′, 2′′, and 1′′, as well as unpartitioned, and at Mach numbers up to 0.3. For most geometries, 2′′ partition spacing eliminated impedance discontinuities and substantially improved Prony correlation, though effectiveness varied with core topology. Partitions also altered the acoustic response of the liners: resistance increased, resonance frequencies shifted downward, and peak attenuation decreased while bandwidth broadened in some cases. Because partitions modify the liner itself, the educed impedance characterizes the partitioned system rather than the original unpartitioned core. These results establish partitioning as a practical pathway toward liners that are more compatible with standard eduction methods, while demonstrating that the intervention is itself an acoustic design change.

liners↗

Integrating Cybersecurity with System Operations and Restoration

This presentation covers the interaction of the discipline of system operations with the discipline of cybersecurity. First is discussion of a number of fundamental concepts for system operators - organizational division of responsibilities, human and machine cooperation, goals, and priorities. The next section covers the importance of cybersecurity for a system operator organization and explains different risk management approaches based on the consequence and frequency of events. Finally the role of system operators in the security of the grid categorized by the NIST Cybersecurity Framework is discussed to present recommendations and ideas for future work.

24 POWER TRANSMISSION AND DISTRIBUTION↗