Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sterilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

The Screwworm Eradication Data System (SEDS)

One of the objectives of the SEDS was to build a versatile, yet economical, interactive system on the existing digital PDP 11/45 computers used in the Skylab production processing system. Previous experience on various interactive systems gave some background in the best methods of handling image data, registering and correcting the data, and extracting useful information from the images. The screwworm was eliminated in many parts of the United States by air-dropping sterile screwworms in areas where screwworms breed. The reproduction of the screwworm can be more or less predicted based on weather conditions -- cold weather slows the breeding, warm weather fosters it, and some moisture appears to enhance breeding conditions which, in turn, improves the chances of screwworm population growth. To obtain temperature and moisture conditions from remote areas, the NOAA improved TIROS operational satellite was selected to give data from the very high resolution radiometer (VHRR). The VHRR is a two-channel scanning instrument sensitive to energy in the visible spectrum from 0.6 to 0.7 micrometers and the infrared spectrum from 10.5 to 12.5 micrometers.

Quinn, M. J.↗

Studies related to the development of the Viking 1975 labeled release experiment

The labeled release life detection experiment on the Viking 1975 Mars mission is based on the concept that microorganisms will metabolize radioactive organic substrates in a nutrient medium and release radioactive carbon dioxide. Several experiments, using laboratory equipment, were carried out to evaluate various aspects of the concept. Results indicate: (1) label is released by sterilization-treated soil, (2) substantial quantities of label are retained in solution under basic conditions, (3) the substrate used, as well as position of label in the molecule, affect release of label, (4) label release is depressed by radiolytic decomposition of substrates, and (5) About 100,000 organisms are required to produce a detectable response. These results, suggest additional areas for testing, add to the data base for interpretation of flight results, and have significance for broader application of this technique for assessing microbial activity.

Devincenzi, D. L.↗

Health protection and food preservation by gamma irradiation

Results of several major studies on food systems for space missions beginning with Apollo 12 through Apollo-Soyuz and investigations of the application of irradiation to food for manned space flight are reported. The study of flight food systems involved the application of radurization (pasteurizing levels) doses of gamma irradiation to flour and bread supplied by Pepperidge Farms in advance of the missions. All flights from Apollo 12 through 17 carried irradiated fresh bread. On Apollo 17, cooperation with Natick Laboratories permitted the introduction of a ham sandwich using irradiated bread and irradiated sterile ham. Investigations centered on irradiated bread were conducted during the course of these missions. Studies were applied to the concept of improving fresh bread from the point of view of mold inhibition. The studies considered how irradiation could best be applied at what levels and on a variety of bread types. Throughout the studies of the application of gamma irradiation the emphasis was placed upon using low levels of irradiation in the pasteurizing or radurizing doses--under a Megarad. The primary goal was to determine if a public health benefit could be demonstrated using radurization along with food preservation and food quality improvements. The public health benefit would be parallel to that of pasteurization of milk as a concept. Publications are included providing the details of these observations, one dealing with the flour characteristics and the other dealing with the influence on fresh bread types. These demonstrate the major findings noted during the period of the studies examining bread.

Source record↗

The Evolution of the Viking Landing Gear

The primary function of the landing gear is to dissipate touchdown energy in a controlled fashion that minimizes the landing shock for onboard components while maximizing ground clearance and the probability of landing stability over the range of possible surface and touchdown parameter variations. Many other mission requirements and constraints were translated into the evolving Viking landing gear design as they arose. Hence, design considerations included such factors as prelaunch heat sterilization and noncontamination of the Martian landing site, gear stowage and deployment, terminal descent engine shutdown initiation, structural load attenuation, hard/soft landing surface capability, reliability, weight, and post-landed stability.

Pohlen, J. C.↗

Detailed results of ASTP experiment MA-011

This experiment was developed in order to conduct engineering and operational tests of electrokinetic equipment in a micro-gravity environment. The experimental hardware in general functioned as planned and electrophoretic separations were obtained in space. The results indicated the development of satisfactory sample collection, return, and preservation techniques. The application of a near-zero zeta potential interior wall coating to the experimental columns, confirmation of biocompatibility of all appropriate hardware components, and use of a sterile operating environment provided a significant step forward in the development of a biological processing facility in space. A separation of a test of aldehyde-fixed rabbit, human, and horse red blood cells was obtained. Human kidney cells were separated into several components and viable cells returned to earth. The isotachophoretic separation of red cells was also demonstrated. Problems associated with the hardware led to a lack of success in the attempt to separate subpopulations of human lymphocytes.

Seaman, G. V. F.↗

Viking lander spacecraft battery

The Viking Lander was the first spacecraft to fly a sterilized nickel-cadmium battery on a mission to explore the surface of a planet. The significant results of the battery development program from its inception through the design, manufacture, and test of the flight batteries which were flown on the two Lander spacecraft are documented. The flight performance during the early phase of the mission is also presented.

Newell, D. R.↗

Screwworm Eradication Data System (SEDS) applications program documentation, part 2

National Oceanic and Atmospheric Administration (NOAA) satellite data, which is in analog tape form, is converted into output data products. These products are used by investigators in determining optimum areas for airdrops of steril screwworm flies over Mexico. The output product of SEDS takes the form of imagery data film slides showing Mexico and the lower southwest portion of the United States. The area analog preprocessing phase of the SEDS task is covered.

Source record↗

Viking labeled release biology experiment - Interim results

All results of the labeled-release life-detection experiment conducted on Mars prior to conjunction are summarized. Tests at both landing sites provide remarkably similar evolution of radioactive gas upon addition of a radioactive nutrient to the Mars sample. The 'active' agent in the sample is stable to 18 C, but is substantially inactivated by heat treatment for 3 hours at 50 C and completely inactivated at 160 C, as would be anticipated if the active response were caused by microorganisms. Results from test and heat-sterilized control samples are compared with those obtained from terrestrial soils and a lunar sample. Possible nonbiological explanations of the Mars data are reviewed. Although such explanations of the labeled-release data depend on UV irradiation, the labeled-release response does not appear to depend on recent direct UV activation of surface material. Available facts do not yet permit a conclusion regarding the existence of life on Mars.

Levin, G. V.↗

Effect of 30 months in a locked environment on the microbial flora of dogs

It has been proposed that the microbial flora of mammals would simplify to a few microbial species if the host animal was confined to a 'locked' environment and provided with sterile food, water, and air. This paper updates information on the microbial profile (feces, nose and throat) of purebred beagles housed in the above-mentioned conditions through a 30-month study period and demonstrates that no drastic decrease or simplification of the microbial profile occurred in isolated or control dogs.

Balish, E.↗

Fibre evaluation for spacecraft cleaning

The employment of vacuum brushes utilizing sable tail hair for the physical removal of particulates from spacecraft surfaces has become problematical in connection with a lack of compatibility of the bristle with sterilization and biological decontamination procedures required for spacecraft cleaning. An investigation was, therefore, conducted to find a suitable fiber which can replace sable bristle. Felor fiber was found to have the best properties for use in a motorized cleaning brush.

Jensen, W. M.↗

Microbiological profiles of the Viking spacecraft

Planetary quarantine requirements associated with the launch of two Viking spacecraft necessitated microbiological assessment during assembly and testing at Cape Canaveral and the Kennedy Space Center. Samples were collected from the Viking Lander Capsules (VLC), Orbiters (VO), and Shrouds at predetermined intervals during assembly and testing. Levels of bacterial spores per square meter on the VLC-1 and VLC-2 were 1.6 x 10 squared and 9.7, respectively, prior to dry-heat sterilization. The ranges of aerobic mesophilic microorganisms detected on the VO-1 and VO-2 were 4.2 x 10 squared to 4.3 x 10 cubed and 2.3 x 10 squared to 8.9 x 10 cubed/sq m, respectively. Approximately 1300 colonies were picked from culture plates, identified, lyophilized, and stored for future reference. About 75% of all isolates were microorganisms considered indigenous to humans; the remaining isolates were associated with soil and dust. The percentage of microorganisms of human origin was consistent with results obtained with previous automated spacecraft but slightly lower than those observed for manned (Apollo) spacecraft.

Puleo, J. R.↗

Automated electrochemical selection of coliforms

Computer-controlled sensor system monitors and quantifies coliform organisms in waste water samples through molecular hydrogen detection techniques. System includes cleanup procedures, external sterilization of each sensor interface with working fluid as well as incubation cell interiors. Sensor system may also be operated manually.

Taylor, R. E.↗

Microbial load monitor

Design analysis of a microbial load monitor system flight engineering model was presented. Checkout of the card taper and media pump system was fabricated as well as the final two incubating reading heads, the sample receiving and card loading device assembly, related sterility testing, and software. Progress in these areas was summarized.

Caplin, R. S.↗

Recent results from the Viking Labeled Release experiment on Mars

The Labeled Release (LR) life detection experiment seeks detection of heterotrophic metabolism by monitoring radio-active gas evolution following the addition of a radioactive nutrient containing seven C-14 labeled organic substrates to surface material. LR results obtained on Mars prior to conjunction showed rapid evolution of radioactive counts upon addition of the nutrient to a fresh surface sample. The responses at both landing sites were quite similar. The additional results summarized in the present paper provide further information on the gas kinetics following a second injection of nutrient and on the effect of 'cold sterilization' of the Martian surface material. Specifically, it is shown that the production of gas from the LR nutrient is remarkably uniform; after reaction approaches completion, addition of more nutrient results in a net loss of the radioactive gas; the reactant in the Mars soil is completely inhibited by heating the soil to 160 C, and is largely inhibited by heating to 46 C. In contrast, exposure to 18 C for 2 sol (1 sol = 24.6 hr) does not appear to inhibit the reaction.

Levin, G. V.↗

Survival and reversion of a stable L form in soil

The stable L form of Agromyces ramosus reverted to a bacterial form when incubated in sterilized soil. The cellular and colonial morphology of this bacterial form resembled that of the original parent bacterial form. The two forms differed, however, in that the revertant maintained its bacterial form when transferred onto a low-salt (NaCl) medium but was virtually completely induced into the L-form state on a high-salt medium. The original parent bacterial form was not sensitive to salt. The possibility is discussed that an L-form - bacterial-form cycle for this bacterium might occur naturally in soil. This cycle would be mediated by fluctuations in local salt concentrations in the soil.

Horwitz, A. H.↗

A subcutaneous channeling probe for implanting long leads

The channeling probe described in the present paper was designed to overcome surgical problems of the type that were encountered when a multichannel radio transmitter had to be implanted in a cow. The probe was made of a flexible but sufficiently stiff 9.5-mm-diam nylon rod, consisting of 46-cm sections for convenience in sterilization and surgical handling. Stainless steel sleaves reinforced the threaded connecting joints. At one end, arrowhead-shaped channeling heads could be attached to produce wide channels for large sensors. The other end was tapered for narrow channels. Postoperative problems were not encountered in the use of this probe in cows, sheep, and dogs.

Lund, G. F.↗

Operational Loopwheel Suspension System for Mars Rover Demonstration Model

The loopwheel (or elastic loop) mobility concept, appears to be uniquely qualified to provide a high degree of mobility at low weight and stowage requirements for the next Mars mission now in the early planning stage. Traction elements compatible with sterilization and Mars surface environmental constraints were designed and are compatible with the rover mass, range and stowage requirements of JPL's point design Mars rover. In order to save cost, the loopwheel suspensions for the demonstration model were made of S-glass/epoxy instead of titanium, alloy specified for flight units. The load carrying fiberglass loop core is covered by a rubber tread on the outside. Reinforced rubber gear belts bonded along the inside edges provide positive engagement and transmission drive torques. A 12 Vdc drive motor with a 167:1 gear head is installed in the payload section of the hull. A chain drive transmits the motor power to the rear sprocket in the demonstration model, whereas future flight units would be directly driven by brushless hub motors within each sprocket and independent four-leg height control.

Trautwein, W.↗

Infrared analysis of polyethylene wear specimens using attenuated total reflection spectroscopy

Attenuated total reflection infrared spectroscopy was used to analyze ultrahigh molecular weight polyethylene wear test specimens. Three different specimens were analyzed. One specimen was gamma irradiated to a dose of 5.0 MRad, another to a dose of 2.5 MRad, and the final specimen was unirradiated. There was no conclusive evidence of chemical changes (i.e., unsaturation or oxidation) in the surface regions of any of the polyethylene samples. Therefore, it was concluded that the gamma irradiation sterilization procedure shoud not alter the boundary lubricating properties of the polyethylene.