Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Data for Evaluation of Strategies to Narrow the Product Chain-Length Distribution of Microbially Synthesized Free Fatty Acids

The dominant strategy for tailoring the chain-length distribution of free fatty acids (FFA) synthesized by heterologous hosts is expression of a selective acyl-acyl carrier protein (ACP) thioesterase. However, few of these enzymes can generate a precise (greater than 90% of a desired chain-length) product distribution when expressed in a microbial or plant host. The presence of alternative chain-lengths can complicate purification in situations where blends of fatty acids are not desired. We report the assessment of several strategies for improving the dodecanoyl-ACP thioesterase from the California bay laurel to exhibit more selective production of medium-chain free fatty acids to near exclusivity. We demonstrated that matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS) was an effective library screening technique for identification of thioesterase variants with favorable shifts in chain-length specificity. This strategy proved to be a more effective screening technique than several rational approaches discussed herein. With this data, we isolated four thioesterase variants which exhibited a more selective FFA distribution over wildtype when expressed in the fatty acid accumulating E. coli strain, RL08. We then combined mutations from the MALDI isolates to generate BTE-MMD19, a thioesterase variant capable of producing free fatty acids consisting of 90% of C12 products. Of the four mutations which conferred a specificity shift, we noted that three affected the shape of the binding pocket, while one occurred on the positively charged acyl carrier protein landing pad. Finally, we fused the maltose binding protein (MBP) from E. coli to the N – terminus of BTE-MMD19 to improve enzyme solubility and achieve a titer of 1.9 g per L of twelve-carbon fatty acids in a shake flask.

Conversion↗

Half-life and gamma abundance ratio measurements of Sm-153

The measurement of the decay of 153Sm was observed by gamma spectrometry, liquid scintillation counting and gas proportional counting in an attempt to confirm the half life and gamma abundance ratios for this isotope. Recent changes in the published nuclear decay data indicate that historical literature values may be biased. The 153Sm was made by the neutron activation of ultrapure isotopically enriched 152Sm to create 153Sm. The decay measurements were made over a three week period and no other isotopes were detected during this time. The gamma abundance ratio for the 103 keV gamma was measured to be (27.9%) which is 4% lower than the published data. In addition, the half life was 1.9308 days, which is 0.34% lower than the published data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of Blast Overpressure on the Pharmacokinetics of Various Antibiotics in Sprague Dawley Rats

ABSTRACT Introduction Combat injuries are complex and multimodal. Most injuries to the extremities occur because of explosive devices such as improvised explosive devices. Blast exposure dramatically increases the risk of infection in combat wounds, and there is limited available information on the best antibiotic treatments for these injuries. We previously demonstrated that mice exposed to blast displayed a delayed clearance of cefazolin from the plasma and liver; further semi-mechanistic modeling determined that cefazolin concentrations in the skin of these mice were reduced. Our objective was to investigate the effects of blast on the pharmacokinetics of antibiotics of different types used for the treatment of combat wounds in the rat model. Materials and Methods Male Sprague Dawley rats were exposed to blast overpressure followed by injection of a bolus of animal equivalent doses of an antibiotic (cefazolin, cefepime, ertapenem, or clindamycin) into the tail vein at 1-hour post-blast exposure. Blood was collected at predetermined time points via repeated sampling from the tail vein. Animals were also euthanized at predetermined time points, at which time liver, kidney, skin, and blood via cardiac puncture were collected. Antibiotic concentrations were determined by ultra-performance liquid chromatography–tandem mass spectrometry. Results Blast-exposed rats exhibited a similar rate of clearance compared to non-blasted rats in the blood, liver, kidney, and skin, which is inconsistent with the data regarding cefazolin in blast-exposed mice. Conclusions Our results in rats do not recapitulate our previous observation of delayed cefazolin clearance in mice following the blast overpressure exposure. Although using rats permitted us to collect multiple blood samples from the same animals, rats may not be a suitable model for measuring the pharmacokinetics of antibiotics following blast. The interpretation of the results may be challenging because of variation in data among rat subjects in the same sample groups.

General & Internal Medicine↗

Experiments with the LECO Pegasus® Gas Chromatograph/ Time-of-Flight Mass Spectrometer Phase 1: Fast GC Separations and Comparison of the GC/TOF-MS with Conventional Quadrupole GC/MS and Fast Quadrupole GC/MS

Conventional analysis by gas chromatography/quadrupole mass spectrometry (GC/MS) can be time-consuming (30 – 60 minutes) and prone to interferences. The use of fast gas chromatography coupled with time-of-flight mass spectrometry (GC/TOF-MS) offers the advantages of faster (13 min) analysis times, improved GC resolution afforded by the use of narrower (0.1– 0.18 mm i.d.) columns, and improved mass resolution and data acquisition speed provided by the TOF-MS. In addition, GC/TOF-MS offers the promise of better detection limits than quadrupole GC/MS, while still providing the full mass spectral data which offers an additional level of confidence in analyte identification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fuel Fabrication Capability (FFC) Scrap Recycle Report

The Global Threat Reduction Initiative (GTRI) is currently engaged in the development of an ultra-high density low enriched uranium (LEU) fuel for its high-performance research reactors. The fuel consists of a monolithic uranium-molybdenum alloy containing 10% (weight/weight, or w/w) Mo (U-10Mo) enclosed in Al-6061 cladding with a Zr bonding layer. Significant losses are expected in the manufacturing of the LEU fuel, so a means to recycle uranium from the scrap pieces is needed. Uranium can also be recovered from irradiated U-10Mo fuels. As a result, Argonne National Laboratory (Argonne) is assisting by developing an aqueous processing flowsheet for scrap recovery in the fuel fabrication process and for spent fuel recovery. Experiments are being done to verify predicted dissolution conditions and optimize HNO 3 and HF concentrations for timely dissolution of the fuel without the formation of precipitates, while meeting the requirements needed for further processing by a tributyl phosphate solvent extraction procedure to recover uranium from a nitric acid–based media. Dissolution conditions will be discussed first for the U-10Mo foils, followed by the U-10Mo foils with Al cladding, and finally the U-10Mo foils with Al cladding and a Zr bonding layer. The goal of the dissolution experiments is to test predicted conditions from earlier reports; these conditions were based on literature data and make the necessary adjustments to successfully dissolve the LEU fuels without the formation of precipitates. Final concentrations of all fuel components were determined by Inductively Coupled Plasma Mass Spectrometry (ICP-MS), and the error associated with the values is ±10%.

Youker, Amanda J.↗

New Constraints on the Abundance of 60 Fe in the Early Solar System

Establishing the abundance of the extinct radionuclide 60 Fe (half-life 2.62 Ma) in the early solar system is important for understanding the astrophysical context of solar system formation. While bulk measurements of early solar system phases show a low abundance consistent with galactic background, some in situ measurements by secondary ion mass spectrometry (SIMS) imply a higher abundance, which would require injection from a nearby supernova (SN). In this paper, we present in situ nickel isotopic analyses by resonance ionization mass spectrometry (RIMS) in a chondrule from the primitive meteorite Semarkona (LL3.00). The same chondrule had been previously analyzed by SIMS. Despite improved precision compared to SIMS, the RIMS nickel isotopic data do not reveal any resolved excesses of 60 Ni that could be unambiguously ascribed to in situ 60 Fe decay. Linear regression of 60 Ni/ 58 Ni versus 56 Fe/ 58 Ni yields an initial 60 Fe/ 56 Fe ratio for this chondrule of (3.8 ± 6.9) × 10 -8 , which is consistent with both the low initial value found by bulk measurements and the low end of the range of initial ratios inferred from some in situ work. The same regression also gives a solar initial 60 Ni/ 58 Ni ratio, which shows that this sample was not disturbed by nickel mobilization, thus agreeing with a low initial 60 Fe/ 56 Fe ratio. These findings agree with a re-evaluation of previous SIMS measurements of the same sample. Finally, supernova injection of 60 Fe into the solar system or its parental cloud material is therefore not necessary to account for the measured solar system's initial amount of 60 Fe.

79 ASTRONOMY AND ASTROPHYSICS↗

Carbonyl Formation during High Efficiency Clean Combustion of FACE Fuels

The low temperature conditions that occur during high efficiency clean combustion (HECC) often lead to the formation of partially oxidized HC species such as aldehydes, ketones and carboxylic acids. Using the diesel fuels specified by the Fuels for Advanced Combustion Engines (FACE) working group, carbonyl species were collected from the exhaust of a light duty diesel engine operating under HECC conditions. High pressure liquid chromatography - mass spectrometry (LC-MS) was used to speciate carbonyls as large as C 9 . A relationship between carbonyl species formed in the exhaust and fuel composition and properties was determined. Data were collected at the optimum fuel efficiency point for a typical road load condition. Results of the carbonyl analysis showed changes in formaldehyde and acetaldehyde formation, formation of higher molecular weight carbonyls and the formation of aromatic carbonyls. Details of these changes in carbonyl formation and discussion of formation mechanisms will be presented.

Lewis Sr, Samuel Arthur↗

Experimental vaporization of the Holbrook chondrite

The vapor phase composition obtained by heating samples of the Holbrook L6 chondrite to 1300 C was determined quantitatively by Knudsen cell-quadrupole mass spectrometry. Maximum observed vapor pressures, produced at 1200 C, are reported for Na, K, Fe, and Ni, and the implications of the Na/K ratio are considered. The Fe and Ni data are discussed with attention to their migration in individual equilibrated chondrites. S2 (with minor SO2), H2O, and CO2 were also present in the high-temperature gas phase. Vesicles formed by the release of intrinsically derived volatiles are compared with vesicles in the Ibitira eucrite. Chondrite evolution is briefly discussed.

Gooding, J. L.↗

,* Copper transport and accumulation in spruce stems (picea abies(L.) Karsten) revelaed by laser-induced breakdown spectroscopy

Laser-Induced Breakdown Spectroscopy (LIBS) in double pulse configuration (DP LIBS) was used for scanning elemental spatial distribution in annual terminal stems of spruce (Picea abies (L.) Karsten). Cross sections of stems cultivated in Cu2+ solution of different concentrations were prepared and analyzed by DP LIBS. Raster scanning with 150 μm spatial resolution was set and 2D (2-dimentional) maps of Cu and Ca distribution were created on the basis of the data obtained. Stem parts originating in the vicinity of the implementation of the cross sections were mineralized and subsequently Cu and Ca contents were analyzed by inductively coupled plasma mass spectrometry (ICP-MS). The results provide quantitative information about overall concentration of the elements in places, where LIBS measurements were performed. The fluorescence pictures were created to compare LIBS distribution maps and the fluorescence intensity (or the increase in autofluorescence) was used for the comparison of ICP-MS quantitative results. Results from these three methods can be utilized for quantitative measurements of copper ions transport in different plant compartments in dependence on the concentration of cultivation medium and/or the time of cultivation.

Krajcarova, Lucie↗

Radiation Tolerance Studies of Commercial Strippable Coatings and Fixatives used for Decontamination - 18642

A number of commercially available products, designed for use as strippable coating and fixatives for decontamination purposes, were tested to determine their tolerability to high radiation fields and how they potentially degrade. Each product was cured and exposed to γ-radiation from a Co-60 source, up to a total dose of 500 kGy. Obvious physical colour changes and deformities were detected by visual inspection, and images captured by scanning electron microscope (SEM) showed major differences post-irradiation in some coatings. Other physical changes to the coatings were measured using Fourier-transform infrared spectroscopy (FT-IR), Raman spectroscopy, and energy-dispersive X-ray spectroscopy (EDS); both pre- and post-irradiation. FT-IR suggested that some chemical changes were taking place in the coatings, in particular the C-H bonds and the fingerprint region appeared to be drastically altered in some coatings. EDS data indicated an increase in surface oxygen content as a result of irradiation in the majority of the samples. Additionally, coating samples were subjected to analysis by gas chromatography mass spectrometry (GCMS) in order to determine the evolved gases. The GC-MS results show that short chain hydrocarbons are produced to some degree in all the coatings during irradiation. Finally, three of the best performing coatings were selected and were irradiated using an ion beam, mimicking Pu alpha particles (with energy of around 5.25 MeV). Using the Dalton Cumbrian Facility's 5 MV tandem accelerator, coating samples were irradiated by ∼5.25 MeV He{sup 2+} particles to total dose of approximately 500 kGy. Samples were analysed using SEM, FT-IR, Raman and EDS, as was done for the gamma irradiated samples, allowing a comparison to be made between α-particle and γ-ray damage. Results from the alpha and gamma irradiations showed many similarities for the comparable assessments. A number of spectral changes observed in the FT-IR analysis were consistent across both γ-ray and α-particle irradiated samples. While there were some differences, these may be attributed to the conditions under which the irradiations were carried out. The observed similarities may allow for the inference of alpha degradation by Co-60 gamma irradiation as a more easily accessible method for determining the extent of radiolytic damage. Furthermore, gamma irradiation allows for additional analysis that is currently otherwise not possible to achieve with ion-beam exposure. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spatially Resolved Mass Spectrometry at the Single Cell: Recent Innovations in Proteomics and Metabolomics

Biological systems are composed of heterogeneous populations of cells that intercommunicate to form a functional living tissue. Biological function varies greatly across populations of cells, as each single cell has a unique transcriptome, proteome, and metabolome that translates to functional differences within single species and across kingdoms. Over the past decade, substantial advancements in our ability to characterize omic profiles on a single cell level have occurred, including in multiple spectroscopic and mass spectrometry (MS)-based techniques. Of these technologies, spatially resolved mass spectrometry approaches, including mass spectrometry imaging (MSI), have shown the most progress for single cell proteomics and metabolomics. For example, reporter-based methods using heavy metal tags have allowed for targeted MS investigation of the proteome at the subcellular level, and development of technologies such as laser ablation electrospray ionization mass spectrometry (LAESI-MS) now mean that dynamic metabolomics can be performed in situ. In this Perspective, we showcase advancements in single cell spatial metabolomics and proteomics over the past decade and highlight important aspects related to high-throughput screening, data analysis, and more which are vital to the success of achieving proteomic and metabolomic profiling at the single cell scale. Finally, using this broad literature summary, we provide a perspective on how the next decade may unfold in the area of single cell MS-based proteomics and metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

ToF-SIMS spectral data analysis of Paenibacillus sp. 300A biofilms and planktonic cells

Analysis of bacterial biofilms is particularly challenging and important with diverse applications from systems biology to biotechnology. Among the variety of techniques that have been applied, time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying the surface characteristics of biofilms. ToF-SIMS offers high spatial resolution and high mass accuracy, which permit surface sensitive analysis of biofilm components. Thus, ToF-SIMS provides a powerful solution to addressing the challenge of bacterial biofilm analysis. This dataset covers ToF-SIMS analysis of Paenibacillus sp. 300A (300A) isolated from the Hanford site in Richland, WA. The strain is known to have metal and sulfur reducing properties and can be used for bioremediation, wastewater treatment, bioengineering and technology development. There is a current need to identify small molecules and fragments produced from bacterial biofilms. Static ToF-SIMS spectra of 300A were obtained using an IONTOF TOF-SIMS V instrument equipped with a 25 keV Bi 3 + metal ion gun. Identified molecules and molecular fragments are compared against known biological databases and the reported peaks have at least 65 ppm mass accuracy. These molecules range from lipids and fatty acids to flavonoids, quinolones, and other naturally occurring organic compounds. It is anticipated that the spectral identification of key peaks will assist detection of metabolites, extracellular polymeric substance molecules like polysaccharides, and biologically relevant small molecules using ToF-SIMS in future surface and interface research of bacterial biofilms.

Biofilms↗

Theoretical Analysis of Experimental Data of Sodium Diffusion in Oxidized Molybdenum Thin Films

In this work, the diffusion process of sodium (Na) in molybdenum (Mo) thin films while it was deposited on soda lime glass (SLG) was studied. A small amount of oxygen was present in the chamber while the direct-current (DC) magnetron sputtering was used for the deposition. The substrate temperatures were varied to observe its effect. Such molybdenum films, with or without oxidations, are often used in thin film solar cells, either as back contact or as hole transport layers. Secondary ion mass spectrometry (SIMS) was used to quantify the concentration of the species. A grain diffusion mechanistic model incorporating the effect of grain and grain boundary geometrical shape and size was developed. The model was used to provide an in-depth theoretical analysis of the sodium diffusion in molybdenum thin films that lead to the measured SIMS data. It was observed that not only diffusion coefficients should be considered when analyzing diffusion processes in thin films but also the ratio of grain boundary size to grain size. Both depend on substrate temperature and directly affect the amount of diffused species in the film. The data were analyzed under the light of the film growth speed versus diffusion front speed, the effect of oxygen content, and the effect of substrate temperature on the overall diffusion process. The temperature inversely affects the ratio of grain boundary size and grain size and directly affects the diffusion coefficient, which leads to a preferable temperature at which the highest amount of alkali can be found in the film.

36 MATERIALS SCIENCE↗

Surface-Induced Dissociation of Protein Complexes in a Hybrid Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

Mass spectrometry continues to develop as a valuable tool in the analysis of proteins and protein complexes. In protein complex mass spectrometry studies, surface-induced dissociation (SID) has been successfully applied in quadrupole time-of-flight (Q-TOF) instruments. SID provides structural information on non-covalent protein complexes that is complementary to other techniques. However, the mass resolution of Q-TOF instruments can limit the information that can be obtained for protein complexes by SID. Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) provides ultrahigh resolution and ultrahigh mass accuracy measurements. In this study, an SID device was designed and successfully installed in a hybrid FT-ICR instrument in place of the standard gas collision cell. The SID-FT-ICR platform has been tested with several protein complex systems (homooligomers, a heterooligomer, and a protein-ligand complex, ranging from 53 kDa to 85 kDa), and the results are consistent with data previously acquired on Q-TOF platforms, matching predictions from known protein interface information. SID fragments with the same m/z but different charge states are well-resolved based on distinct spacing between adjacent isotope peaks, and the addition of metal cations and ligands can also be isotopically resolved with the ultrahigh mass resolution available in FT-ICR.

Environmental Molecular Sciences Laboratory↗

Isotopic yield measurement in the heavy mass region for {sup 239}Pu thermal neutron induced fission

Despite the huge number of fission yield data available in the different evaluated nuclear data libraries, such as JEFF-3.1.1, ENDF/B-VII.0, and JENDL-4.0, more accurate data are still needed both for nuclear energy applications and for our understanding of the fission process itself. It is within the framework of this that measurements on the recoil mass spectrometer Lohengrin (at the Institut Laue-Langevin, Grenoble, France) was undertaken, to determine isotopic yields for the heavy fission products from the {sup 239}Pu(n{sub th},f) reaction. In order to do this, a new experimental method based on {gamma}-ray spectrometry was developed and validated by comparing our results with those performed in the light mass region with completely different setups. Hence, about 65 fission product yields were measured with an uncertainty that has been reduced on average by a factor of 2 compared to that previously available in the nuclear data libraries. In addition, for some fission products, a strongly deformed ionic charge distribution compared to a normal Gaussian shape was found, which was interpreted as being caused by the presence of a nanosecond isomeric state. Finally, a nuclear charge polarization has been observed in agreement, with the one described on other close fissioning systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated Pest Management (IPM) for Early Detection Algal Crop Protection. Final Report

During large-scale, outdoor algal biomass growth, production strain(s) are subject to attack by pathogens, predators, and non-productive competitors, compromising the biomass yield. The project team at UCSD developed and demonstrated the effectiveness of Volatile Organic Compound, VOC, analysis via mass spectrometry (MS) as an early detection system for the presence of production algal ponds infection. The MS detection can then trigger high-resolution melt analysis (HRMA) and enhanced quantitative PCR (qPCR) to identify predatory or pathogenic species precisely. This study gathered the foundational data informing how wholly automated systems monitor the health of production ponds. By detecting the presence of low molecular weight VOCs in the air space above ponds, the instrument was able to mimic “sniffing” the health of the algae pond. This early warning system will be free growers from time-consuming and costly regular surveillance of ponds with the current techniques, such as qPCR and flow-cam assays, which are slower, less sensitive, and not easily fully automated, resulting in increased production efficiency through the reduction of crop loss. This project demonstrated that Chemical Ionization Mass Spectrometry, CIMS, could serve as a real-time monitor of ponds health tracking up to 100 different VOCs simultaneously for continuous periods up to 60 days without interruption, signaling infection within an algal crop 24 to 36 hours prior to techniques such as qPCR and microscopy. While mass spectrometry is an expensive tool, this simple VOC sampling system proved not only to be sensitive and robust but could to multiplexed to monitor several ponds, lowering the overall cost serially. This technology demonstrated a reduction in biomass production cost by approximately 50% compared to growers not employing any detection methodology.

09 BIOMASS FUELS↗

Mass spectrometry imaging: Towards mapping the elemental and molecular composition of the rhizosphere

This short review will discuss and provide perspective into the utilization of mass spectrometry imaging (MSI) in studying the rhizosphere. It also serves to compliment the multi-omic focused review by White et al. in this journal issue, as MSI is capable of elucidating chemical distributions within samples of interest in an in situ fashions, and thus can provide spatial context to MS omics data in complementary experimental endeavors. The majority of reported MSI-based studies of plant-microbe interactions have focused on the phyllosphere and ‘associated rhizosphere’ (e.g., material that is not removed during harvesting), as sample preparation for these in situ analyses tends to be a limiting factor. These studies have provided valuable insight into the spatial arrangement of proteins, peptides, lipids, and other metabolites within these systems. We intend for this short review to be a primer about the history of MSI and its role in plant-microbe analysis. Along the way we reference many comprehensive reviews for the interested reader. Lastly, we offer a perspective on the future of MSI and its use in understanding the molecular transformations beyond what we coined as the ‘associated rhizosphere’ to the rest of rhizosphere zone and into the bulk soil.

54 ENVIRONMENTAL SCIENCES↗

IsoForma: An R Package for Quantifying and Visualizing Positional Isomers in Top-Down LC-MS/MS Data

Proteoforms, the different forms of a protein with sequence variations including post-translational modifications (PTMs), execute vital functions in biological systems such as cell signaling and epigenetic regulation. Precisely defining the stoichiometry of PTMs has been challenging because, in the widely used bottom-up proteomics methods, the detection occurs at the peptide level and thus the link between peptides and their specific modification site is lost, resulting in proteoform ambiguity. Advances in top-down mass spectrometry (MS) technology have permitted the direct characterization of intact proteoforms and their exact number of modification sites, allowing for the relative quantification of positional isomers (PI). Proteins with positional isomers refers to proteoforms with identical total mass and set of modifications but varying PTM site combinations. The relative abundance of PI can be estimated by matching proteoform-specific fragment ions to top-down tandem MS (MS2) data to localize and quantify modifications. However, current approaches heavily rely on manual annotation. Here, we present IsoForma, an open-source R package for relative quantification of PI within a single tool. We benchmarked IsoForma’s performance against two existing workflows and highlight the similarity of the results and improvements in speed. Overall, IsoForma provides a streamlined process, reduces the time of conducting isoform-based analyses, and offers an essential framework for developing customized proteoform analysis workflows. Finally, the software is open source and available at https://github.com/EMSL-Computing/isoforma-lib.

59 BASIC BIOLOGICAL SCIENCES↗