Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation detection systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

The X-ray binary, UW CMa

The UW CMa is a close, eclipsing binary composed of an O7f primary with a stron wind and a less luminous O-type companion. It was found that UW CMa a variable X-ray source, whose X-ray variations are in phase with its optical light curve. Since both components of the binary system are O stars, accretion by a compact object is ruled out as a mechanism for generating X-rays. The UW CMa represents a new class of X-ray binaries, in which X-rays result from the collision of a wind from one star with the surface or wind of the other star. It is hypothesised that the impact of a wind against a star generates a shock wave about 0.25 stellar radii above the stellar surface, and material behind the shock front, heated to bout 10 million degrees, radiates the X-ray apparent X-ray variability is due to its location between the two stars, where it undergoes eclipses. The high temperature region maintains an ionization cavity in the wind, as detected with IUE. The ionization cavity is the source of depletion of absorbing ions in the wind between the two stars.

Heap, S. R.↗

Properties of cirrus from multispectral AVHRR imagery data

The discovery that the 11 and 12 microns window channels of AVHRR could be used to detect and even characterize the properties of cirrus stimulated the present study which reexamines the general multispectral approach for retrieving cirrus cloud top temperature and emissivity. The generalized multispectral approach described compliments the CO2 slicing method used by Wylie and the bispectral threshold methods used by Minnis et al. While the results shown were for 11 and 12 micron radiances, better definition of the cloud top temperature is probably obtainable using 3.7 micron radiances in combination with the 11 and 12 micron radiances. During the day reflection of solar radiation at 3.7 micron by low level water clouds makes the analysis untenable. At night, at least with the NOAA-9 AVHRR, instrument noise in the 3.7 micron channel also makes the analysis untenable. The identification of semitransparent systems using 3.7 micron radiances has been noted elsewhere.

Coakley, James A., Jr.↗

A Novel Segmentation Algorithm for the ARM User Facility All-Sky Imagers Using Machine Learning Applications

Cloud cover plays a pivotal role in modulating the Earth's energy budget through the reflection of incoming solar radiation and the trapping of outgoing longwave radiation. Ground-based all-sky imagers offer an objective assessment of cloud cover that can be used to estimate solar irradiance, classify cloud types, track cloud movement, and serve as a benchmark 10 for the evaluation of satellite and reanalysis data products. The Atmospheric Radiation Measurement (ARM) user facility has utilized all-sky imagers for more than 25 years to monitor cloud cover and augment its comprehensive suite of atmospheric measurements. Following the retirement of its Total Sky Imager (TSI), ARM recently deployed the TSI’s successor, the All Sky Imager (ASI-16 camera systems). To provide a smooth transition and continuity to the vast amount of knowledge gathered by the TSI over the years, while addressing typical deployment issues, we developed a novel pixel segmentation algorithm, 15 the ASI Sky Cover (ASISKYCOVER). ASISKYCOVER builds on the different strengths and properties of the TSI processing algorithm while integrating machine learning techniques, ensuring data validity and accuracy across diverse atmospheric conditions. It enhances cloud cover characterization with new features such as artifact detection and uncertainty quantification. ASISKYCOVER also includes cloud cover estimates for near-zenith (narrow field-of-view) and reduces susceptibility to false detections. This study introduces ASISKYCOVER, details its algorithm framework, and demonstrates its capabilities using a 20 year-long dataset from the ARM Southern Great Plains site. Comparisons with co-located TSI data and other ARM measurements, such as zenith-pointing radars and lidars, are presented, underscoring the ASISKYCOVER’s potential to improve cloud cover analyses and data evaluation efforts, as well as to be integrated into higher-level data products that synergize instrument suites to generate new and insightful information

Silber, Israel↗

Deuterated methane observed on Saturn

The detection of CH3D in the 5-micron spectrum of Saturn, as obtained by a Fourier transform spectrometer, is reported. A CH3D abundance of 2.6 plus or minus 0.8 centimeter-amagat has been found along with a temperature of 175 plus or minus 30 K for the mean level of spectroscopic line formation. This suggests that the observed flux is due to thermal radiation from relatively deep levels within the atmosphere. This CH3D abundance indicates a deuterium/hydrogen ratio of approximately 2 x 10 to the -5th power, which is of a magnitude similar to that of Jupiter. This value is considerably lower than the terrestrial and meteoritic value of 15 x 10 to the -5th power. If stellar processing of the deuterium that formed the solar system is minimal, this ratio may be representative of the primordial ratio at the time of the formation of the universe.

Fink, U.↗

Light output quenching in response to deuterium-ions and alpha particles and pulse shape discrimination in deuterated trans-stilbene

We characterized the light output response of a new 140 cm 3 stilbene-d 12 crystal up to 14.1 MeV neutron energies using a coincidence neutron scattering system. We also characterized its light output response to alpha particles in the 5 to 6 MeV energy range. The excellent PSD capability of the stilbene-d 12 detector allowed us to select light pulses produced by particles of increasing ionization density, namely electrons, protons, deuterium-ions, and alpha particles. The measured fast decay component of the light pulses is increasingly quenched as the ionization density of the particle in the crystal increases. Consistently with this finding, the Birks’ quenching parameter of alpha particles is approximately 8.5 times larger compared to the quenching of deuterium ions, produced by neutron scattering interactions. The reported experimental characterization will allow high-fidelity modeling of the detector enabling its application for fast-neutron detection and spectroscopy in nuclear physics, radiation protection, nuclear security, and non-proliferation.

36 MATERIALS SCIENCE↗

A teleoperated system for remote site characterization

The detection and characterization of buried objects and materials is an important step in the restoration of burial sites containing chemical and radioactive waste materials at Department of Energy (DOE) and Department of Defense (DOD) facilities. By performing these tasks with remotely controlled sensors, it is possible to obtain improved data quality and consistency as well as enhanced safety for on-site workers. Therefore, the DOE Office of Technology Development and the US Army Environmental Center have jointly supported the development of the Remote Characterization System (RCS). One of the main components of the RCS is a small remotely driven survey vehicle that can transport various combinations of geophysical and radiological sensors. Currently implemented sensors include ground-penetrating radar, magnetometers, an electromagnetic induction sensor, and a sodium iodide radiation detector. The survey vehicle was constructed predominantly of non-metallic materials to minimize its effect on the operation of its geophysical sensors. The system operator controls the vehicle from a remote, truck-mounted, base station. Video images are transmitted to the base station by a radio link to give the operator necessary visual information. Vehicle control commands, tracking information, and sensor data are transmitted between the survey vehicle and the base station by means of a radio ethernet link. Precise vehicle tracking coordinates are provided by a differential Global Positioning System (GPS).

Sandness, Gerald A.↗

Measuring Black Hole Light Echoes with Very Long Baseline Interferometry

Light passing near a black hole can follow multiple paths from an emission source to an observer due to strong gravitational lensing. Photons following different paths take different amounts of time to reach the observer, which produces an echo signature in the image. The characteristic echo delay is determined primarily by the mass of the black hole, but it is also influenced by the black hole spin and inclination to the observer. In the Kerr geometry, echo images are demagnified, rotated, and sheared copies of the direct image and lie within a restricted region of the image. Echo images have exponentially suppressed flux, and temporal correlations within the flow make it challenging to directly detect light echoes from the total light curve. In this Letter, we propose a novel method to search for light echoes by correlating the total light curve with the interferometric signal at high spatial frequencies, which is a proxy for indirect emission. We explore the viability of our method using numerical general relativistic magnetohydrodynamic simulations of a near-face-on accretion system scaled to M87-like parameters. We demonstrate that our method can be used to directly infer the echo delay period in simulated data. An echo detection would be clear evidence that we have captured photons that have circled the black hole, and a high-fidelity echo measurement would provide an independent measure of fundamental black hole parameters. Our results suggest that detecting echoes may be achievable through interferometric observations with a modest space-based very long baseline interferometry mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of spatial, radiometric and spectral thematic mapper performance for coastal studies

An area along the southeastern shore of the Chesapeake Bay was subsetted from TM imagery. The subsetted image was then enhanced and classified using an ERDAS 400 system. Results obtained were compared with a chart showing the distribution of both Zolsters marina and Rupplia martime in the Vaucluse Shores and which supports a large community of SAV. Radiative transfer models describing the irradiance reflectance of a water column containing SAV are being refined. Radiative transfer theory was used to model upwelling radiance for an orbiting sensor viewing an estuarine environment. Upwelling radiance was calculated for a clear maritime atmosphere, an optically shallow estuary of either clear or turbid water, and one of three bottom types: vegetation, sand, or mud using TM bands 1, 2, and 3 and MSS bands 4 and 5. A spectral quality index was defined similar to the equation for apparent contrast and used to evaluate the relative effectiveness of TM and MSS bands in detecting submerged vegetation.

Klemas, V.↗

Advanced Microwave Precipitation Radiometer (AMPR) for remote observation of precipitation

The design, development, and tests of the Advanced Microwave Precipitation Radiometer (AMPR) operating in the 10 to 85 GHz range specifically for precipitation retrieval and mesoscale storm system studies from a high altitude aircraft platform (i.e., ER-2) are described. The primary goals of AMPR are the exploitation of the scattering signal of precipitation at frequencies near 10, 19, 37, and 85 GHz together to unambiguously retrieve precipitation and storm structure and intensity information in support of proposed and planned space sensors in geostationary and low earth orbit, as well as storm-related field experiments. The development of AMPR will have an important impact on the interpretation of microwave radiances for rain retrievals over both land and ocean for the following reasons: (1) A scanning instrument, such as AMPR, will allow the unambiguous detection and analysis of features in two dimensional space, allowing an improved interpretation of signals in terms of cloud features, and microphysical and radiative processes; (2) AMPR will offer more accurate comparisons with ground-based radar data by feature matching since the navigation of the ER-2 platform can be expected to drift 3 to 4 km per hour of flight time; and (3) AMPR will allow underflights of the SSM/I satellite instrument with enough spatial coverage at the same frequencies to make meaningful comparisons of the data for precipitation studies.

Galliano, J. A.↗

Development of a Comprehensive Physics-Based Model for Study of NASA Gateway Lunar Dust Contamination

NASA is committed to landing the first woman and first person of color on the Moon by 2025 to begin a sustaining presence. A major component of this mission is NASA’s orbiting lunar outpost, Gateway, that will be subjected to the harsh environment of space during its 7-day orbit around the Moon. One aspect of this environment that is not well quantified is microscopic lunar regolith particles, or simply, lunar dust. As Apollo 17 Mission Commander Eugene Cernan said, “I think dust is probably one of our greatest inhibitors to a nominal operation on the moon. I think we can overcome other physiological or physical or mechanical problems except dust” [1]. These dust particles, most of which are smaller than the width of two human hairs and of highly irregular shape, are composed mainly of dielectric materials. Such characteristics can allow the dust particles to collect electric charge from the surrounding environment, resulting in electrostatic interactions between the dust, electromagnetic fields, and electrically charged surfaces [2-3]. Due to the nature of these fields, dust can collect on and contaminate charged surfaces. Lunar dust introduced into the Gateway environment by a lunar ascent vehicle element returning from the surface of the Moon presents risks to Gateway hardware such as radiators, solar arrays, antennae, and docking mechanisms. To quantify this risk and inform NASA, International Partner, and Commercial Provider stakeholders, Booz Allen, in partnership with NASA, is developing a toolset to model the interaction of charged lunar dust particles with the cis-lunar and deep-space environments. This includes a comprehensive physics model of the space plasma and solar radiation environment and electromagnetic interaction of spacecraft and lunar dust. Spacecraft charging and plasma environment are solved using the open-source code from The French Aerospace Lab (ONERA) and the European Space Agency (ESA), known as Spacecraft Plasma Interaction Software (SPIS) [4]. The physics of particle charging and motion is handled by a time-dependent implementation of Orbital-Motion-Limited (OML) theory which accounts for plasma flows and positive potential grains [5-7], using Siemens STAR-CCM+ as the framework. Model validation includes lab experiments by NASA experts and academia, as well as future on-orbit dust detecting payloads on the exterior of Gateway and Commercial Lunar Payload Services (CLPS) missions to the lunar surface [7-9]. The results and analyses will inform Gateway Program system owners at risk for lunar dust contamination.

Complex Plasma↗

Assessment of Cloud Mask Forecasts from the WRF-Solar Ensemble Prediction System: Preprint

Numerical weather prediction (NWP) models are important tools used by government agencies and the renewable energy enterprise to forecast solar radiation. Cloud prediction, a key process of NWP models, has the highest impact on the accuracy of solar forecasting. This study uses satellite observations from the National Solar Radiation Data Base (NSRDB) to evaluate the cloud mask forecast by the WRF-Solar Ensemble Prediction System (WRF-Solar EPS). Preliminary analysis of the data in 2018 demonstrates the need of further improvement in predicting thin and low-level clouds. The information obtained from this work will be used to enhance the WRF-Solar EPS in reproducing the cloud field over the contiguous U.S. and reducing solar forecasting errors.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Natural attenuation of uranium in a fluvial Wetland: Importance of hydrology and speciation

A nuclear fuel fabrication facility released 43,500 kg of uranium into a riparian wetland located on the Savannah River Site between 1955 and 1988. Studies were undertaken to evaluate hydrological and geochemical processes influencing uranium accumulation in the wetland. Gamma-radiation-mapping surveys were conducted by systematically walking over the contaminated wetland with backpacks equipped with global positioning systems and NaI gamma detectors. Based on maps compiled from >700,000 gamma spectra and eight sediment uranium depth profiles, it was determined that 94% of the released uranium remained in the wetland. The uranium in the wetland is concentrated in five multi-hectare areas along the stream, accounting for ~11% of the land area adjacent to the stream. While land type (upland or wetland) and topography provided a reasonable first approximation of where much of the uranium was deposited, hydrological watershed modeling revealed that the stream velocity was especially slow through many of the hot spots. Here, using autoradiography combined with SEM/EDX measurements of contaminated sediments, surprisingly few hot particles were detected. Instead, uranium was evenly distributed throughout the sampled sediment, suggesting that dissolved uranium had bound to sediment particles that became suspended and later deposited in low energy (low flow velocity) portions of the stream. EXAFS suggested that U atoms were present as individual ions in disordered complexes within the sediment. Furthermore, linear combination analyses suggested that the predominant component of the U(VI) was adsorbed to sediment minerals (~70%) and a minor component (~30%) was associated with organic matter phases. Furthermore, these studies show that wetlands can be extraordinarily effective at binding and retaining uranium, thereby providing a natural barrier to the transport of uranium out of a watershed. However, significant anthropogenic or climatic changes to wetlands, such as those associated with flooding, forest fires, or land use, may disrupt the complex hydrological and biogeochemical balance necessary to maintain long-term immobilization of uranium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Two-color, intracavity pump–probe, cavity ringdown spectroscopy

Here, we report a proof-of-principle demonstration of intracavity pump–probe, cavity ringdown (CRD) detection in a three-mirror, traveling-wave cavity. With cavity-enhanced pump power and probe absorption path length, the technique is a generally applicable, high-sensitivity, high-selectivity detection method. In our experiments, the pump radiation is switched off during every other probe ringdown, which allows uncorrelated measurements of analyte and background cavity decay rates. The net, two-color signal from the difference between the pump-on and pump-off decay rates is immune to empty-CRD drifts and spectral overlaps from non-target molecular transitions. The immunity to the ringdown drifts allows longer signal-averaging and, thus, higher detection sensitivity. The ability to compensate for the background absorption enhances the detection selectivity in spectrally congested regions. Our technique is well-suited for trace-detection in the mid-IR region, where pump–probe schemes based on strong rovibrational transitions can be applied. In this work, two-color CRD detection is implemented on a ladder-type, three-level system based on the N 2 O, ν 3 = 1 ← 0, P(19) (pump) and ν 3 = 2 ← 1, R(18) (probe), rovibrational transitions. By frequency-locking two-quantum cascade lasers to the p-polarization (pump, Finesse = 5280) and s-polarization (probe, Finesse = 67 700) cavity modes, we achieve high intracavity pump power (36 W) and high probe ringdown rates (>2 kHz). The observed two-color spectra are simulated by a density-matrix, three-level system model that is solved under the constraints of the cavity resonance conditions. In addition to its background compensation capability, experimental flexibility in the selection of pump–probe schemes and signal insensitivity to intracavity laser power are further features that enhance the utility of our technique for mid-IR trace-detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman-shifting an ArF excimer laser to generate new lines for obtaining optical diagnostic based information in flow fields

The application of tunable excimer lasers in combustion and flow diagnostics is almost routine nowadays. The properties of this laser system that enable density and temperature measurements in supersonic and hypersonic flow fields to be conducted are its high power, high repetition rate, and high spectral brightness. The limitation imposed by this system on these measurements is the paucity of lines in the wavelength region, the vacuum-ultraviolet, where species of interest, such as OH, N2, O2, H2, H2O, CO, NO, etc., are susceptible to electronic excitation to high-lying states. To circumvent this problem one normally resorts to nonlinear optical techniques such as frequency conversion via stimulated Raman scattering (SRS), more commonly known as Raman shifting or Raman mixing, to extend these nonintrusive and nonperturbing techniques to the shorter wavelengths in the VUV region and, for that matter, to longer wavelengths in the infrared region, if the need arises. The theoretical basis of SRS and its application are well documented in the literature. In essence, the Raman shift is a consequence of the inelastic scattering of the incident radiation by the sample. Most of the scattered radiation from the molecules of the sample is unchanged in frequency. However, a small fraction of the incident radiation is changed in frequency. This shift is a result of the fact that some of the incident photons on colliding with the molecules of the sample give up some of their energy and emerge with a lower energy resulting in the lower-frequency Stokes radiation. Other incident photons may increase their energy by colliding with the vibrationally excited molecules of the medium and emerge as higher-frequency antistokes radiation. The generation of the latter is the main objective of this project. The process, however, depends on several factors, including the beam quality of the pump laser, the cross-section of the gaseous medium, the gas pressure, and the ambient temperature of the gas near the focal region. Furthermore, since the Raman shifting process is polarization sensitive, it is necessary to have all of the laser energy in a single polarization. These factors were taken into consideration in the execution of the project. The implementation of the Raman shift was accomplished by focusing the 193 nm output of an ArF excimer laser (Lamda-Physik LPX 150) into a 1-meter long high pressure recirculating Raman cell filled with H2 gas. The laser system was modified in order to improve the mode quality of the pump beam to enhance the Raman shifting. To accomplish this feat, a prism beam expander and grating on the oscillator discharge provided wavelength tuning over the excimer gain profile. Furthermore, a triple-pass configuration, as opposed to unstable resonator optics, was employed in the operation of the amplifier cavity so that when the oscillator output radiation, focused by a 51-cm focal length fused silica lens through a 50 micron pinhole (serving as a spatial filter) and recollimated with a 25-cm focal length lens, was fed into the amplifier, it was injection locked, thereby providing tunable radiation with relatively low divergence. The forward scattered radiation emanating from the impingement of the modified pump beam on the Raman cell was detected using an energy meter after the latter had been separated from it using a dispersing prism.

Koker, Edmond B.↗

Airborne Spectral Measurements of Ocean Directional Reflectance

During summer of 2001 NASA's Cloud Absorption Radiometer (CAR) obtained measurement of ocean angular distribution of reflected radiation or BRDF (bidirectional reflectance distribution function) aboard the University of Washington Convair CV-580 research aircraft under cloud-free conditions. The measurements took place aver the Atlantic Ocean off the eastern seaboard of the U.S. in the vicinity of the Chesapeake Light Tower and at nearby National Oceanic and Atmospheric Administration (NOAA) Buoy Stations. The measurements were in support of CLAMS, Chesapeake Lighthouse and Aircraft Measurements for Satellites, field campaign that was primarily designed to validate and improve NASA's Earth Observing System (EOS) satellite data products being derived from three sensors: MODIS (MODerate Resolution Imaging Spectro-Radiometer), MISR (Multi-angle Imaging Spectro-Radiometer) and CERES (Clouds and Earth s Radiant Energy System). Because of the high resolution of the CAR measurements and its high sensitivity to detect weak ocean signals against a noisy background, results of radiance field above the ocean are seen in unprecedented detail. The study also attempts to validate the widely used Cox-Munk model for predicting reflectance from a rough ocean surface.

Gatebe, Charles K.↗

Circuit and Method for Communication Over DC Power Line

A circuit and method for transmitting and receiving on-off-keyed (OOK) signals with fractional signal-to-noise ratios uses available high-temperature silicon- on-insulator (SOI) components to move computational, sensing, and actuation abilities closer to high-temperature or high-ionizing radiation environments such as vehicle engine compartments, deep-hole drilling environments, industrial control and monitoring of processes like smelting, and operations near nuclear reactors and in space. This device allows for the networking of multiple, like nodes to each other and to a central processor. It can do this with nothing more than the already in-situ power wiring of the system. The device s microprocessor allows it to make intelligent decisions within the vehicle operational loop and to effect control outputs to its associated actuators. The figure illustrates how each node converts digital serial data to OOK 18-kHz in transmit mode and vice-versa in receive mode; though operations at lower frequencies or up to a megahertz are within reason using this method and these parts. This innovation s technique modulates a DC power bus with millivolt-level signals through a MOSFET (metal oxide semiconductor field effect transistor) and resistor by OOK. It receives and demodulates this signal from the DC power bus through capacitive coupling at high temperature and in high ionizing radiation environments. The demodulation of the OOK signal is accomplished by using an asynchronous quadrature detection technique realized by a quasi-discrete Fourier transform through use of the quadrature components (0 and 90 phases) of the carrier frequency as generated by the microcontroller and as a function of the selected crystal frequency driving its oscillator. The detected signal is rectified using an absolute-value circuit containing no diodes (diodes being non-operational at high temperatures), and only operational amplifiers. The absolute values of the two phases of the received signal are then summed and hard limited (digitized) by comparing them to a reference level and are then input into a microprocessor as a serial bit stream. The quasi-discrete Fourier transform is performed in high-temperature components (operational amplifiers, analog switches, resistors, and capacitors). The demodulated signal is a serial data stream that is input to the UART (universal asynchronous receiver transmitter) receiver pin of the microprocessor. The OOK of the carrier frequency uses the output of the UART pin as an enabling signal that drives the gate of the MOSFET. Logic low bits enable the carrier frequency (realized by using the 0 phase signal from the microcontroller, though either phase may be used) to be DC-coupled to the power supply bus through a current-limiting resistor mounted between the MOSFET drain and the supply rail. The presence of logic lows on the power supply rail is realized by carrier bursts while logic highs are realized by the absence of bursts.

Krasowski, Michael J.↗

In-situ Detection of Glovebox Glove Degradation Prior to Glove Failure; Effects on Safety, Waste, and Operational Costs - 20402

Glovebox glove pressure decay leak testing and analysis of the data can greatly improve glovebox safety, minimize Transuranic (TRU) glove waste, and minimize operational cost. It is well known, the weakest point of containment on a glovebox is the glove. Mitigating unplanned openings in gloves is critical to minimizing operational and safety costs in glovebox operations. Mitigating unplanned glove openings due to glove failures will be discussed in this paper. The lack of an engineered solution to determine a gloves operational life in nuclear operations, has lead to use of theoretical and manual subjective methods to determine the life and safety of a glovebox glove. Whether the glove is inspected visually prior to use, or gloves are changed regularly to theoretically avoid failure, both the operators PPE and the room are being exposed to contamination, or un-necessary amounts of TRU glove waste are being generated. Millions of dollars yearly in operational costs are spent on glove failures due to loss of production, incident analysis, regulatory audits, clean up, and paperwork. In a nuclear application, a glove failure could contaminate an operator and laboratory, shut down the operation for weeks, potentially create a regulatory audit, and potentially create a media frenzy; the damages to the organization can be astronomical. Elimination of glove failures is possible by tracking glove material degradation and setting limits to allow glove change when it becomes necessary, prior to glove failure. Analytical pressure decay leak testing allows the detection of material degradation, and in turn the ability to limit operational glove failures. A German based company called MK Versuchsanlagen, e.K., has developed an advanced Glove Integrity Testing System. The system, with its use of proprietary RFID and special software technology, is unique in its capabilities. The system is capable to perform highly accurate regular glove testing on any size glovebox line in minimal time. The system records and can analyze a tremendous amount of system data that in turn can determine, for example, a safe glove change time prior to a glove material failure. This paper will show how an advanced Glove Integrity Testing System can detect glove material degradation and help determine a safe change point prior to glove failure. Pressure decay curves of new gloves and recorded effects of accelerated aging on the glove over time will be shown. The use of this technology in nuclear facilities can greatly improve glovebox operational safety, minimize glovebox glove TRU waste, and save organizations tremendous costs in downtime, clean up, documentation, and potential regulatory review. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Technology Development of Miniaturized Far-Infrared Sources for Biomolecular Spectroscopy

The objective of this project was to develop a purely solid-state based, thus miniaturized, far-infrared (FIR) (also known as terahertz (THz)) wave source using III-V semiconductor nanostructures for biomolecular detection and sensing. Many biomolecules, such as DNA and proteins, have distinct spectroscopic features in the FIR wavelength range as a result of vibration-rotation-tunneling motions and various inter- and intra-molecule collective motions. Spectroscopic characterization of such molecules requires narrow linewidth, sufficiently high power, tunable (in wavelength), and coherent FIR sources. Unfortunately, the FIR frequency is one of the least technologically developed ranges in the electromagnetic spectrum. Currently available FIR sources based on non-solid state technology are bulky, inefficient, and very often incoherent. In this project we investigated antimonide based compound semiconductor (ABCS) nanostructures as the active medium to generate FIR radiation. The final goal of this project was to demonstrate a semiconductor THz source integrated with a pumping diode laser module to achieve a compact system for biomolecular applications.

Kono, Junichiro↗