Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Figures of merit for focusing mega-electron-volt ion beams in biomedical imaging and proton beam writing

A figure of merit (FOM) has been developed for focusing quadrupole multiplet lenses for ion micro- and nanobeam systems. The method which is based on measurement of the central peak of the two-dimensional autocorrelation function of an image provides separate FOM for the horizontal and vertical directions. The approach has been tested by comparison with the edge widths obtained by nonlinear fitting the edge widths of a Ni grid and found to be reliable. The FOM has the important advantage for ion beam imaging of biomedical samples that the fluence needed is considerably lower than for edge fitting.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Double-shot MeV electron diffraction and microscopy

Here in this paper, we study by numerical simulations a time-resolved MeV electron scattering mode where two consecutive electron pulses are used to capture the evolution of a material sample on 10 ps time scales. The two electron pulses are generated by illuminating a photocathode in a radiofrequency photogun by two short laser pulses with adjustable delay. A streak camera/deflecting cavity is used after the sample to project the two electron bunches on two well separated regions of the detector screen. By using sufficiently short pulses, the 2D spatial information from each snapshot can be preserved. This “double-shot” technique enables the efficient capture of irreversible dynamics in both diffraction and imaging modes. Finally, in this work, we demonstrate both modes in start-to-end simulations of the UCLA Pegasus MeV microscope column.

36 MATERIALS SCIENCE↗

Two-phase accurate multiplexed structured image capture (2pAc-MUSIC)

Multiplexed Structural Image Capture (MUSIC) technique uses modulation of light from a scene prior to imaging to encode the temporal evolution of target into spatial frequency shifts, with each shift corresponding to a unique time and resulting in individual distinct snapshots. Computational-processing of the multiplexed single-shot image can recover the nanosecond-resolution scene evolution. One of the limitations is the loss of spatial resolution of the recovered image due to limitations of the low-pass spatial frequency filtering depth. Here we demonstrated that two images with complementary spatial phases can be used to enhance the spatial resolutions. For this application, 2 Phase Accurate (2pAc)-MUSIC is implemented that a scene is encoded with two complementary phases. The increased spatial information captured reduces the lower frequency noise in the Fourier domain found in single-phase MUSIC. A recovery algorithm combines the 180-degree spatial frequency shifted images into a single scene and applies a spatial filter in the Fourier domain that has a larger depth than previously possible to achieve a scene with increased spatial resolution. The 2pAc-MUSIC can effectively enhance the spatial resolution by removing the overlapping zero-order spatial frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New approach to terahertz diagnostics of human psychoemotional state

A new approach to terahertz (THz) diagnostics of the human psychoemotional state is proposed, based on the analysis of the THz contribution to the total signal while simultaneously recording the IR and THz emissions from the human body (hereinafter referred to as the IR – THz image). The developed image-processing algorithm allows extraction of the informative contribution determined by the THz radiation from the total signal perceived by the recording system. Simultaneous registration of the IR – THz images of the human face and the psychophysiological indicators are carried out in situations of physical stress (short-term intense physical exercise – squats functional test), electrical stimulation, and information stress (cognitive load – simple arithmetic mental calculations). The obtained data are compared with those of similar measurements at rest. It is shown that using cluster analysis of IR – THz images it is possible to divide the test subjects into classes according to the type of reaction of the circulatory system under stressful conditions. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Communication: Imaging the effects of the antisymmetric-stretching excitation in the O({sup 3}P) + CH{sub 4}(v{sub 3} = 1) reaction

Effects of one-quantum excitation of the antisymmetric-stretching mode of CH{sub 4}(v{sub 3} = 1) on the O({sup 3}P) + CH{sub 4} reaction were studied in a crossed-beam, ion-imaging experiment. In the post-threshold region, we found that (1) the product state distributions are dominated by the CH{sub 3}(0{sub 0}) + OH(v{sup ′} = 1) pair, (2) the product angular distributions extend toward sideways from the backward dominance of the ground-state reaction, and (3) vibrational excitation exerts a positive effect on reactivity, but translational energy is more efficient in promoting the rate of this central-barrier reaction. All major findings agree reasonably well with recent theoretical results. Some remaining questions are pointed out.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantum confining excitons with an electrostatic moiré superlattice

Quantum confining excitons has been a persistent challenge in the pursuit of strong exciton interactions and quantum light generation. Unlike electrons, which can be readily controlled via electric fields, imposing strong nanoscale potentials on excitons to enable quantum confinement has proven challenging. In this study, we utilize piezoelectric force microscopy to image the domain structures of twisted hexagonal boron nitride (h – BN), revealing evidence of strong in-plane electric fields at the domain boundaries. By placing a monolayer MoSe 2 only one to two nanometers away from the twisted h – BN interface, we observe energy splitting of neutral excitons and Fermi polarons by several millielectronvolts at the moiré domain boundaries. By directly correlating local structural and optical properties, we attribute such observations to excitons confined in a nanoscale one-dimensional electrostatic potential created by the strong in-plane electric fields at the moiré domain boundaries. Intriguingly, this 1D quantum confinement results in pronounced polarization anisotropy in the excitons’ reflection and emission, persistent to temperatures as high as ~80 Kelvins. Furthermore, these findings open new avenues for exploring and controlling strongly interacting excitons for classical and quantum optoelectronics.

2-dimensional systems↗

Application of tomographic particle image velocimetry to studies of transport in complex (dusty) plasma

Over the past twelve years, two-dimensional and stereoscopic particle image velocimetry (PIV) techniques have been used to obtain detailed measurements of the thermal and transport properties of the microparticle component of dusty plasma systems. This letter reports on an extension of these techniques to obtain a volumetric, three-dimensional velocity vector measurement using tomographic PIV. Initial measurements using the tomographic PIV diagnostic are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SISGR: Atom chip microscopy: A novel probe for strongly correlated materials

Microscopy techniques co-opted from nonlinear optics and high energy physics have complemented solid-state probes in elucidating the order manifest in condensed matter materials. Up until now, however, no attempts have been made to use modern techniques of ultracold atomic physics to directly explore properties of strongly correlated or topologically protected materials. Our current program is focused on introducing a novel magnetic field microscopy technique into the toolbox of imaging probes. Our prior DOE ESPM program funded the development of a novel instrument using a dilute gas Bose-Einstein condensate (BEC) as a scanning probe capable of measuring tiny magnetic (and electric) DC and AC fields above materials. We successfully built the world's first “scanning cryogenic atom chip microscope”, and we now are in the process of characterizing its performance before using the instrument to take the first wide-area images of transport flow within unconventional superconductors, pnictides and oxide interfaces (LAO/STO), topological insulators, and colossal magnetoresistive manganites. We will do so at temperatures outside the capability of scanning SQUIDs, with ~10x better resolution and without 1/f-noise. A notable goal will be to measure the surface-to-bulk conductivity ratio in topological insulators in a relatively model-independent fashion. We have completed the construction of this magnetic microscope. The instrument uses atom chips—substrates supporting micron-sized current-carrying wires that create magnetic microtraps near surfaces for ultracold thermal gases and BECs—to enable single-shot and raster-scanned large-field-of-view detection of magnetic fields. The fields emanating from electronic transport may be detected at the 10 -7 flux quantum (Φ0) level and below; that is, few to sub-micron resolution of sub-nanotesla fields over single-shot, millimeter-long detection lengths. By harnessing the extreme sensitivity of atomic clocks and BECs to external perturbations, we are now in a position to use atom chips for imaging transport in new regimes. Scanning quantum gas atom chip microscopy introduces three very important features to the toolbox of high-resolution scanning microscopy of strongly correlated or topological materials: simultaneous detection of magnetic and electric fields (down to the sub-single electron charge level; no invasive large magnetic fields or gradients; simultaneous micro- and macroscopic spatial resolution; DC to MHz detection bandwidth; freedom from 1/ƒ flicker noise at low frequencies; and, perhaps most importantly, the complete decoupling of probe and sample temperatures. The atom chip microscope can operate at maximum sensitivity and resolution without regard to the substrate temperature. While the BEC is among the coldest objects realizable (100 nK temperatures are typical), the atom chip substrate can be positioned 1 μm away from the BEC and be as hot as 400 K or as cold as the cryostat can cool. This is because unlike superconducting probes, whose temperature is closely coupled to nearby materials, quantum gases are immune to radiative heating. The energy gap between a Rb atom’s ground state and first excited state far exceeds the typical energy of room-temperature blackbody radiation; such atoms are therefore transparent to radiation heating by materials at room temperature or below. We experimentally demonstrated a new atom chip trapping system that allows the placement and high-resolution imaging of ultracold atoms within microns from any ≤100 μm-thin, UHV-compatible material, while also allowing sample exchange with minimal experimental downtime. The sample is not connected to the atom chip, allowing rapid exchange without perturbing the atom chip or laser cooling apparatus. Exchange of the sample and retrapping of atoms has been performed within a week turnaround, limited only by chamber baking. Moreover, the decoupling of sample and atom chip provides the ability to independently tune the sample temperature and its position with respect to the trapped ultracold gas, which itself may remain in the focus of a high-resolution imaging system. We confine 100-nK BECs of 104 87Rb atoms near a gold-mirrored 100-μm-thick silicon substrate. The substrate can be cooled to 35 K without use of a heat shield, while the atom chip, 120-μm away, remains at room temperature. Atoms may be imaged with 1-μm resolution and retrapped every 16 s, allowing rapid data collection. Straightforward improvements will allow us to push sample temperatures close to 4 K, and improve imaging resolution from 1 μm down to a few-100 nm, thereby providing 10 -9 Φ0 detection sensitivity. We will test the utility of this technique by imaging the magnetic fields emanating from electronic transport and domain percolation in several interesting examples of strongly correlated or topologically protected materials. STM, transport, and x-ray scattering experiments have, among others, revealed the existence of a quantum liquid crystal state in iron (pnictide) and cuprate superconductors. This strongly correlated state of matter could also be detected by imaging the fluctuating transport (spatially and in time) of electrons as the phase/regime boundary is crossed between the pnictide non-Fermi liquid (cuprate strange metal) and the pnictide magnetic phase (cuprate pseudogap regime). Our ability to image wide-area inhomogeneous current flow from room-temperature to <10 K will allow us to study the developing domain structure and transport near twin boundary interfaces through the T N ≈50–150 K nematic transition recently identified in bulk transport experiments by Ian Fisher's group in underdoped Fe-arsinide superconductors. Again, this highlights a main feature of our cryogenic atom chip microscope: the ability to image transport regardless of the sample temperature since the BEC, at nK temperatures, is transparent to blackbody radiation, even when held a microns from the surface.

36 MATERIALS SCIENCE↗

Polarization of Coronal Forbidden Lines

Since the magnetic field is responsible for most manifestations of solar activity, one of the most challenging problems in solar physics is the diagnostics of solar magnetic fields, particularly in the outer atmosphere. To this end, it is important to develop rigorous diagnostic tools to interpret polarimetric observations in suitable spectral lines. This paper is devoted to analyzing the diagnostic content of linear polarization imaging observations in coronal forbidden lines. Although this technique is restricted to off-limb observations, it represents a significant tool to diagnose the magnetic field structure in the solar corona, where the magnetic field is intrinsically weak and still poorly known. We adopt the quantum theory of polarized line formation developed in the framework of the density matrix formalism, and synthesize images of the emergent linear polarization signal in coronal forbidden lines using potential-field source-surface magnetic field models. The influence of electronic collisions, active regions, and Thomson scattering on the linear polarization of coronal forbidden lines is also examined. It is found that active regions and Thomson scattering are capable of conspicuously influencing the orientation of the linear polarization. These effects have to be carefully taken into account to increase the accuracy of the field diagnostics. We also found that linear polarization observation in suitable lines can give valuable information on the long-term evolution of the magnetic field in the solar corona.

79 ASTRONOMY AND ASTROPHYSICS↗

Joint spatio-spectral based edge detection for multispectral infrared imagery.

Image segmentation is one of the most important and difficult tasks in digital image processing. It represents a key stage of automated image analysis and interpretation. Segmentation algorithms for gray-scale images utilize basic properties of intensity values such as discontinuity and similarity. However, it is possible to enhance edge-detection capability by means of using spectral information provided by multispectral (MS) or hyperspectral (HS) imagery. In this paper we consider image segmentation algorithms for multispectral images with particular emphasis on detection of multi-color or multispectral edges. More specifically, we report on an algorithm for joint spatio-spectral (JSS) edge detection. By joint we mean simultaneous utilization of spatial and spectral characteristics of a given MS or HS image. The JSS-based edge-detection approach, termed Spectral Ratio Contrast (SRC) edge-detection algorithm, utilizes the novel concept of matching edge signatures. The edge signature represents a combination of spectral ratios calculated using bands that enhance the spectral contrast between the two materials. In conjunction with a spatial mask, the edge signature give rise to a multispectral operator that can be viewed as a three-dimensional extension of the mask. In the extended mask, the third (spectral) dimension of each hyper-pixel can be chosen independently. The SRC is verified using MS and HS imagery from a quantum-dot in a well infrared (IR) focal plane array, and the Airborne Hyperspectral Imager.

99 GENERAL AND MISCELLANEOUS↗

Statistical CT noise reduction with multiscale decomposition and penalized weighted least squares in the projection domain

Purposes: The suppression of noise in x-ray computed tomography (CT) imaging is of clinical relevance for diagnostic image quality and the potential for radiation dose saving. Toward this purpose, statistical noise reduction methods in either the image or projection domain have been proposed, which employ a multiscale decomposition to enhance the performance of noise suppression while maintaining image sharpness. Recognizing the advantages of noise suppression in the projection domain, the authors propose a projection domain multiscale penalized weighted least squares (PWLS) method, in which the angular sampling rate is explicitly taken into consideration to account for the possible variation of interview sampling rate in advanced clinical or preclinical applications. Methods: The projection domain multiscale PWLS method is derived by converting an isotropic diffusion partial differential equation in the image domain into the projection domain, wherein a multiscale decomposition is carried out. With adoption of the Markov random field or soft thresholding objective function, the projection domain multiscale PWLS method deals with noise at each scale. To compensate for the degradation in image sharpness caused by the projection domain multiscale PWLS method, an edge enhancement is carried out following the noise reduction. The performance of the proposed method is experimentally evaluated and verified using the projection data simulated by computer and acquired by a CT scanner. Results: The preliminary results show that the proposed projection domain multiscale PWLS method outperforms the projection domain single-scale PWLS method and the image domain multiscale anisotropic diffusion method in noise reduction. In addition, the proposed method can preserve image sharpness very well while the occurrence of 'salt-and-pepper' noise and mosaic artifacts can be avoided. Conclusions: Since the interview sampling rate is taken into account in the projection domain multiscale decomposition, the proposed method is anticipated to be useful in advanced clinical and preclinical applications where the interview sampling rate varies.

60 APPLIED LIFE SCIENCES↗

Influence of Magnetically Conjugate Fragments of Auroral Emission Images on the Accuracy of Determining E{sub av} of Precipitating Electrons

Results of magnetic conjugation of image fragments of auroral emissions at different altitudes along the magnetic field lines and preliminary results of evaluation of their influence on the accuracy of remote mapping of energy characteristics of precipitating electrons are presented. The results are obtained using the code of tracing being an integral part of the software Vector M intended for calculation of accompanying, geophysical, and astronomical information for the center of mass of a space vehicle (SV) and remote observation of aurora by means of Aurovisor-VIS/MP imager onboard the SV Meteor-MP to be launched.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Solutions to remove a boundary image sticking in an ac plasma display panel

When displaying a square-type image with peak luminance for approximately 500 h in a 42 in. plasma display panel TV with high Xe (15%) content, halo-type boundary image sticking was observed in the nondischarge region adjacent to the discharge region. The halo-type boundary image sticking phenomenon is due mainly to the redeposit of the Mg species on the MgO layer in the nondischarge region adjacent to the discharge region, which is verified by measuring the redeposited Mg species in the boundary image sticking region using a cross-sectional scanning electron microscope. Based on this result, three kinds of solution to remove the boundary image sticking of an ac plasma display panel are introduced. First, we completely recover the boundary image sticking cells by using a full-white aging process. Second, we prohibit the inherent production of boundary image sticking by sealing the plasma display panel under vacuum. The final solution is to prohibit the inherent production of boundary image sticking by use of lower gas pressure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High resolution for confocal fluorescence microscopy via extending zero-region of super-oscillation

Superoscillation is the phenomenon that is observed when a wave oscillates locally faster than its highest Fourier component. Although previous reports have been shown that the superoscillation is highly attractive for imaging, however, the small zero-region area of the superoscillation increases the remarkable effect of the outsidelobes. In this work, we introduce a method using a binary phase mask with radial polarization to extend the zero-region of the superoscillation for high numerical aperture objectives. We successfully design a binary phase mask combining with a radial polarization to obtain a big zero-region of the superoscillation. Evaluation methods rely on point spread function and simulation images are presented. The results demonstrate that our proposed method is very effective for suppressing the outsidelobes. In addition, we show that our technique becomes more effective by adding an amplitude mask.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time-stretch microscopy based on time-wavelength sequence reconstruction from wideband incoherent source

Time-stretch microscopy has emerged as an ultrafast optical imaging concept offering the unprecedented combination of the imaging speed and sensitivity. However, dedicated wideband and coherence optical pulse source with high shot-to-shot stability has been mandated for time-wavelength mapping—the enabling process for ultrahigh speed wavelength-encoded image retrieval. From the practical point of view, exploiting methods to relax the stringent requirements (e.g., temporal stability and coherence) for the source of time-stretch microscopy is thus of great value. In this paper, we demonstrated time-stretch microscopy by reconstructing the time-wavelength mapping sequence from a wideband incoherent source. Utilizing the time-lens focusing mechanism mediated by a narrow-band pulse source, this approach allows generation of a wideband incoherent source, with the spectral efficiency enhanced by a factor of 18. As a proof-of-principle demonstration, time-stretch imaging with the scan rate as high as MHz and diffraction-limited resolution is achieved based on the wideband incoherent source. We note that the concept of time-wavelength sequence reconstruction from wideband incoherent source can also be generalized to any high-speed optical real-time measurements, where wavelength is acted as the information carrier.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Objective models of compressed breast shapes undergoing mammography

Purpose: To develop models of compressed breasts undergoing mammography based on objective analysis, that are capable of accurately representing breast shapes in acquired clinical images and generating new, clinically realistic shapes. Methods: An automated edge detection algorithm was used to catalogue the breast shapes of clinically acquired cranio-caudal (CC) and medio-lateral oblique (MLO) view mammograms from a large database of digital mammography images. Principal component analysis (PCA) was performed on these shapes to reduce the information contained within the shapes to a small number of linearly independent variables. The breast shape models, one of each view, were developed from the identified principal components, and their ability to reproduce the shape of breasts from an independent set of mammograms not used in the PCA, was assessed both visually and quantitatively by calculating the average distance error (ADE). Results: The PCA breast shape models of the CC and MLO mammographic views based on six principal components, in which 99.2% and 98.0%, respectively, of the total variance of the dataset is contained, were found to be able to reproduce breast shapes with strong fidelity (CC view mean ADE = 0.90 mm, MLO view mean ADE = 1.43 mm) and to generate new clinically realistic shapes. The PCA models based on fewer principal components were also successful, but to a lesser degree, as the two-component model exhibited a mean ADE = 2.99 mm for the CC view, and a mean ADE = 4.63 mm for the MLO view. The four-component models exhibited a mean ADE = 1.47 mm for the CC view and a mean ADE = 2.14 mm for the MLO view. Paired t-tests of the ADE values of each image between models showed that these differences were statistically significant (max p-value = 0.0247). Visual examination of modeled breast shapes confirmed these results. Histograms of the PCA parameters associated with the six principal components were fitted with Gaussian distributions. The six-component model was also used to generate CC and MLO view mammogram breast shapes, using the mean PCA parameter values of these distributions and randomly generated values based on the fitted Gaussian distributions, which resemble clinically encountered breasts. A spreadsheet with the data necessary to apply this model is provided as the supplementary material. Conclusions: Our PCA models of breast shapes in both mammographic views successfully reproduce analyzed breast shapes and generate new clinically relevant shapes. This work can aid in research applications which incorporate breast shape modeling, such as x-ray scatter correction, dosimetry, and image registration.

60 APPLIED LIFE SCIENCES↗

Short-circuit current density imaging of crystalline silicon solar cells via lock-in thermography: Robustness and simplifications

Spatially resolved determination of solar cell parameters is beneficial for loss analysis and optimization of conversion efficiency. One key parameter that has been challenging to access by an imaging technique on solar cell level is short-circuit current density. This work discusses the robustness of a recently suggested approach to determine short-circuit current density spatially resolved based on a series of lock-in thermography images and options for a simplified image acquisition procedure. For an accurate result, one or two emissivity-corrected illuminated lock-in thermography images and one dark lock-in thermography image have to be recorded. The dark lock-in thermography image can be omitted if local shunts are negligible. Furthermore, it is shown that omitting the correction of lock-in thermography images for local emissivity variations only leads to minor distortions for standard silicon solar cells. Hence, adequate acquisition of one image only is sufficient to generate a meaningful map of short-circuit current density. Beyond that, this work illustrates the underlying physics of the recently proposed method and demonstrates its robustness concerning varying excitation conditions and locally increased series resistance. Experimentally gained short-circuit current density images are validated for monochromatic illumination in comparison to the reference method of light-beam induced current.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A relative radiometric correction method for airborne SWIR hyperspectral image using the side-slither technique

Stripe noise still remains in airborne short-wave infrared (SWIR) hyperspectral (HS) images after laboratory calibration due to the stray light of HS imager, nonlinear response of infrared focal plane array, and the distinct difference of equivalent color temperature between the integrating sphere and the sun. It is difficult to get a sun-like radiation source, and we apply the side-slither technique for relative radiometric correction of HS images. The calibration data corresponding to different irradiance were obtained by the side-slither technique of imager. Then, the two-point multi-section method is used for relative radiometric correction of HS images. This paper presents the principle, the experimental results, and the analysis of the proposed method. To validate the effectiveness of this method, it was compared with other methods and evaluated by quantitative quality indices. The results reveal that this method has a good performance in relative radiometric correction of HS image and is superior to the laboratory calibration based on integrating sphere. Consequently, the proposed method can successfully eliminate the adverse effect caused by the difference of equivalent color temperature between radiation sources, and also can improve the accuracy of HS applications such as absolute radiation correction and target recognition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗