Fiscal Year 2018 Sodium-CO2 Interaction Test

An experiment campaign was continued in Fiscal Year 2018 in the Argonne National Laboratory (Argonne) SNAKE facility that investigated the interactions between supercritical carbon dioxide (sCO 2 ) and sodium through injection of sCO 2 into an open surface sodium pool. Two of fifteen previous SNAKE tests revealed that self-plugging of the leakage path/nozzle occurs at higher initial sodium temperatures of about 500 ºC due to chemical reactions involving CO 2 , sodium, and sodium-CO 2 reaction products. At lower sodium temperatures, the interaction phenomena involve consumption of injected CO 2 and formation of an agglomerated mass of reaction products without self-plugging. The FY 2018 test investigated interactions at an intermediate initial sodium temperature of about 411 ºC, representative of the interior of a sodium-to-CO 2 heat exchanger in a Sodium-Cooled Fast Reactor (SFR) sCO 2 Brayton Cycle energy conversion system. The experiment was successfully conducted and did not show self-plugging as evidenced by a sustained chemical reaction between the injected CO 2 and sodium and consumption of CO 2 .

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CX-100 Manufacturing (Final Project Report)

This report details the work completed under the CX-100 blade manufacturing project. It presents the tooling design and manufacturing, blade production, blade instrumentation, blade shipping and adapter plate design and fabrication. The CX-100 blade was designed to demonstrate the efficient use of carbon fiber in the spar cap of a wind turbine blade. The baseline blade used for this project was the ERS-100 (Revision D) wind turbine blade. ERS-100 master plugs – for both the high pressure and low pressure skins – were modified to create plugs for the CX-100. Using the new CX-100 master skin plugs, high pressure and low pressure molds were fabricated. Similar modifications were also completed on the shear web plug/mold, the blade assembly fixture and the root stud insertion fixture. Once all of the tooling modifications were complete, a production run of seven CX-100 prototype blades was undertaken. Of those seven blades, four were instrumented with strain gauges before final assembly. After production at the TPI facility in Rhode Island, the blades were shipped to various test sites: two blades to the NWTC at NREL, two blades to Sandia National Laboratory and three blades to the USDA-ARS turbine field test facility located in Bushland, Texas. An adapter plate was designed to allow the CX-100 blades to be installed on existing Micron 65/13M turbines at the USDA site. The conclusion of this program is the kick-off of the blade testing at the three testing facilities.

42 ENGINEERING↗

Quantifying the Tangible Value of Public Electric Vehicle Charging Infrastructure

The lack of an extensive public recharging infrastructure is an important barrier to the growth of the plug-in electric vehicle (PEV) market. Because charging infrastructure is likely to be underutilized during the early stages of market development, it is difficult for decision makers to decide how much to invest in public charging stations. Quantifying the value of public charging infrastructure to current and potential future owners of PEVs is essential for estimating the benefits of charging stations to current PEV owners and for predicting the impact on future PEV sales. This paper estimates consumers’ willingness to pay for public charging infrastructure in the context of utility maximization. The objective is to provide a method for valuing charging infrastructure that can inform investment decisions and be used in forecasting models to predict the impacts on future PEV sales. A basic theory of the tangible value of charging infrastructure is developed as a function of PEV type, range, recharging time and existing infrastructure. Existing simulation studies provide functional relationships that quantify the ability of charging infrastructure to enable additional miles of electrified travel. The enabled travel functions are used to predict impact of infrastructure deployment on incremental electrified travel for 1) plug-in hybrids and 2) intra-regional and 3) inter-regional travel by all-electric vehicles. The willingness to pay for increased electrified miles is derived from the willingness to pay for increased electric driving range, based on econometric studies of plug-in vehicle choice. The result is a set of three functions that can be used to calculate the marginal willingness-to-pay for public charging infrastructure as a function of vehicle attributes, existing charging infrastructure, energy prices and annual vehicle travel.

33 ADVANCED PROPULSION SYSTEMS↗

Accidental Disassembly of a Multi Branch Outlet Strip with Surge Protector (Investigation Report)

On December 16 a worker attempted to disconnect a computer plug from a multi outlet surge protector strip. The plastic housing of the surge protector disintegrated while the plug was pulled exposing the bare conductors of the internal wiring. The worker disconnected the wall plug on the multi outlet strip and de-energized the outlet strip. The worker contacted the FOD and the FOD called the ISR DESO for advice. The DESO collected the pieces and performed an autopsy on the device.

42 ENGINEERING↗

Development and Demonstration of Medium-Heavy Duty PHEV Work Trucks

The heavy-duty vehicle market (Class 6-8) has been a difficult segment for the introduction of plug-in vehicles due to the large energy storage requirement (with corresponding cost), challenging duty cycles, and the diversity of vehicle configurations. The Work Truck market represents a significant opportunity for Heavy-Duty PHEV adoption. (1) The usage cycle includes driving and stationary/worksite power requirements, ensuring full daily usage of the grid-charged battery (battery size: 15-30kWhr). Though daily driving can often be short (an average of 26 miles per day), worksite power includes substantial demand (hydraulics, exportable 110/220V power, 12V support, HVAC). (2) Worksite power demands for conventional vehicles require continuous loaded engine operation, resulting in significant emissions, fuel consumption and noise impacts. (3) These trucks serve an industry that is highly diverse in final vehicle duty cycle, configuration, and jobsite power demands resulting in the need for a modular, configurable hybrid solution. Through this program, Odyne has developed and demonstrated a medium/heavy duty plug-in hybrid solution capable of meeting the needs of the work truck market while delivering fuel and emissions reductions of 50% or greater when evaluated against the full-day work truck duty cycle. The Odyne system developed in this project was released for commercial sale as the G2V7 Odyne Plug-in Hybrid and ePTO systems. The testing and field demonstration proved that the Odyne hybrid system is capable of reducing work truck fuel use and emissions by over 50% while subsequent commercial sales demonstrate the flexibility of the modular design and the capability to support electric systems of 12 – 30 kW and hydraulic based systems of 60 kW (80 HP) or greater. Odyne is continuing to work with suppliers on reducing component costs and working with supporting agencies to initiate projects to increase the driving and full day fuel and emissions savings in order to continue to improve the customer value and return on investment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Seal Strength Calculations for Low Mass DDT Vessel

Lawrence Livermore National Laboratory (LLNL) is collaborating with Colorado School of Mines (Mines), to field the first dynamic experiments on the 3-ring flash radiography system (3-ring). One set of experiments for 3-ring concerns the deflagration to detonation transition (DDT), within a sealed column of high-explosives. The high-explosive material is ignited at one end with a BK-80, an igniter made from Boron Potassium-Nitrate (BKNO 3 ). The initial deflagration reaction will increase the pressure in the sealed vessel, resulting in the formation of a dense "plug" of material ahead of the deflagration front. The transition to detonation is thought to be related to the plug formation. Previous experiments have been able to resolve the plug geometry, but only in a two dimensional radio-graph. 3-ring offers a novel diagnostic tool which could provide three dimensional density fields via few-view reconstruction algorithms and computed tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enabling Low-Temperature (LTP) Ignition Technologies for Multi-Mode Engines through the Development of a Validated High-Fidelity LTP Model for Predicative Simulations Tools

The goal of multi-mode engine architectures is to extend current lean-burn dilution limits with renewable fuels, which requires spark plugs to deposit high energies (hundreds of mJ) in order to initiate ignition and complete combustion. At elevated energy deposition rates, spark plugs experience increased electrode erosion and thermal losses, which ultimately shortens the spark-plug lifetime and lowers ignition efficiency. As such, in order to safeguard the efficiency gains of multi-mode concepts, new and improved ignition technologies are required. Recently, non-equilibrium low-temperature plasmas (LTP) have been shown to promote energy-efficient ignition via quenching and transport of electronically excited atoms and molecules, selective radical production and fast heating of hydrocarbon/air mixtures [1-2]. Thus, LTP is seen as a technology that can potentially improve the energy extraction efficiency of fuels, while enabling kinetically controlled combustion modes towards fuel leaner conditions to realize current DOE VTO goals of improving the sustainability of future mobility [3]. Although many previous studies have demonstrated the efficacy of plasma-assisted ignition to enhance combustion, the detailed enhancement mechanisms remain largely unknown, especially for oxygenated fuels and at elevated pressures that are most relevant to practical engine conditions. These barriers hinder the development of accurate and comprehensive numerical models that seek to describe LTP-based ignition in existing engine design software tools and methods. Current state-of-the-art simulation capabilities for LTP ignition systems are in need of improvements since they deliver qualitative results only due to important limitations of existing approaches. Firstly, validated kinetic models with elementary steps for plasma discharges in oxygenated fuel/air mixtures of relevance to the transportation sector are required. Such kinetic models do not exist at present and will be developed and validated within this project. Secondly, plasma discharges and reactive mixture ignition are multi-scale, unsteady processes requiring high-performance numerical methods and software that execute efficiently on DOE supercomputers. Such software does not exist at present and will be developed and applied to practical LTP ignition scenarios as part of this project. Thirdly, experimental databases that are tailored to serve as benchmark in support of the development of predictive computational models of LTP ignition do not exist and will be part of this project.

33 ADVANCED PROPULSION SYSTEMS↗

Deposition Velocities of Newtonian and Non-Newtonian Slurries in Pipelines

The WTP pipe plugging issue, as stated by the External Flowsheet Review Team (EFRT) Executive Summary, is as follows: “Piping that transports slurries will plug unless it is properly designed to minimize this risk. This design approach has not been followed consistently, which will lead to frequent shutdowns due to line plugging.” A strategy was employed to perform critical-velocity tests on several physical simulants. Critical velocity is defined as the point where a stationary bed of particles deposits on the bottom of a straight horizontal pipe during slurry transport operations. Results from the critical velocity testing provide an indication of slurry stability as a function of fluid rheological properties and transport conditions. The experimental results are compared to the WTP design guide on slurry transport velocity in an effort to confirm minimum waste velocity and flushing velocity requirements as established by calculations and critical line velocity correlations in the design guide. The major findings of this testing is discussed below. Experimental results indicate that the use of the Oroskar and Turian (1980) correlation in the design guide is conservative—Slurry viscosity has a greater affect on particles with a large surface area to mass ratio. The increased viscous forces on these particles result in a decrease in predicted critical velocities from this traditional industry derived equations that focus on particles large than 100 μm in size. Since the Hanford slurry particles generally have large surface area to mass ratios, the reliance on such equations in the Hall (2006) design guide is conservative. Additionally, the use of the 95% percentile particle size as an input to this equation is conservative. However, test results indicate that the use of an average particle density as an input to the equation is not conservative. Particle density has a large influence on the overall result returned by the correlation. Lastly, the viscosity correlation used in the WTP design guide has been shown to be inaccurate for Hanford waste feed materials. The use of the Thomas (1979) correlation in the design guide is not conservative—In cases where 100% of the particles are smaller than 74 μm or particles are considered to be homogeneous due to yield stress forces suspending the particles the homogeneous fraction of the slurry can be set to 100%. In such cases, the predicted critical velocity based on the conservative Oroskar and Turian (1980) correlation is reduced to zero and the design guide returns a value from the Thomas (1979) correlation. The measured data in this report show that the Thomas (1979) correlation predictions often fall below that measured experimental values. A non-Newtonian deposition velocity design guide should be developed for the WTP— Since the WTP design guide is limited to Newtonian fluids and the WTP expects to process large quantities of such materials, the existing design guide should be modified address such systems. A central experimental finding of this testing is that the flow velocity required to reach turbulent flow increases with slurry rheological properties due to viscous forces dampening the formation of turbulent eddies. The flow becomes dominated by viscous forces rather than turbulent eddies. Since the turbulent eddies necessary for particle transport are not present, the particles will settle when crossing this boundary called the transitional deposition boundary. This deposition mechanism should be expected and designed for in the WTP.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resource Characterization and Quantification of Natural Gas-Hydrate and Associated Free-Gas Accumulations in the Prudhoe Bay - Kuparuk River Area on the North Slope of Alaska

Natural gas hydrates have long been considered a nuisance by the petroleum industry. Hydrates have been hazards to drilling crews, with blowouts a common occurrence if not properly accounted for in drilling plans. In gas pipelines, hydrates have formed plugs if gas was not properly dehydrated. Removing these plugs has been an expensive and time-consuming process. Recently, however, due to the geologic evidence indicating that in situ hydrates could potentially be a vast energy resource of the future, research efforts have been undertaken to explore how natural gas from hydrates might be produced. This study investigates the relative permeability of methane and brine in hydrate-bearing Alaska North Slope core samples. In February 2007, core samples were taken from the Mt. Elbert site situated between the Prudhoe Bay and Kuparuk oil fields on the Alaska North Slope. Core plugs from those core samples have been used as a platform to form hydrates and perform unsteady-steady-state displacement relative permeability experiments. The absolute permeability of Mt. Elbert core samples determined by Omni Labs was also validated as part of this study. Data taken with experimental apparatuses at the University of Alaska Fairbanks, ConocoPhillips laboratories at the Bartlesville Technology Center, and at the Arctic Slope Regional Corporation's facilities in Anchorage, Alaska, provided the basis for this study. This study finds that many difficulties inhibit the ability to obtain relative permeability data in porous media-containing hydrates. Difficulties include handling unconsolidated cores during initial core preparation work, forming hydrates in the core in such a way that promotes flow of both brine and methane, and obtaining simultaneous two-phase flow of brine and methane necessary to quantify relative permeability using unsteady-steady-state displacement methods.

02 PETROLEUM↗

Numerical and Experimental Study of an Aircraft Igniter Plasma Jet Discharge

The spark discharge of an aircraft plasma jet igniter is studied using high-fidelity numerical simulations and X-ray radiography measurements. The target problem here features the thermal expansion of hot gas introduced by the electric spark within a confined igniter cavity, which eventually evolves into a pulsed jet of a high-temperature kernel. A comprehensive set of models adapted from existing strategies for internal combustion engine spark plug discharge is extended to the target problem, including the modeling of energy deposition, plasma reactions, thermodynamic properties, and heat losses. A series of validation and parameter studies are performed and presented. The kernel size is found to be sensitive to heat losses arising from radiation and hot gas remained within the discharge cavity, rather than heat conduction to the wall in the discharge cavity. Depending on the enforced shape of the post-breakdown electric arc, the spark kernel can be off-centered, tilted, and considerably asymmetric. These features have been previously not considered when studying such igniter configurations and may have a first-order impact on the ignition process. Provided a proper setup of the heat loss models and electric arc shape, the numerical results are quantitatively comparable to the experimental results in terms of the kernel size, shape, and velocity throughout different stages after the spark discharge.

Tang, Yihao↗

Demand-Side Grid (dsgrid) TEMPO Light-Duty Vehicle Charging Profiles v2022

Simulated hourly electric vehicle charging profiles for light-duty household passenger vehicles in the contiguous United States, 2018-2050. Profiles are differentiated by scenario, county, household and vehicle types, and charging type. Data was produced in 2022 using the Transportation Energy & Mobility Pathway Options (TEMPO) model and published in demand-side grid (dsgrid) toolkit format. Data are available for three adoption scenarios: "AEO Reference Case", which is aligned with the U.S. EIA Annual Energy Outlook 2018 (linked below), "EFS High Electrification", which is aligned with the High Electrification scenario of the Electrification Futures Study (linked below), and "All EV Sales by 2035", which assumes that average passenger light-duty EV sales reach 50% in 2030 and 100% in 2035. The charging shapes are derived from two key assumptions of which data users should be aware: "ubiquitous charger access", meaning that drivers of vehicles are assumed to have access to a charger whenever a trip is not in progress, and "immediate charging", meaning that immediately after trip completion, vehicles are plugged in and charge until they are either fully recharged or taken on another trip. These assumptions result in a bounding case in which vehicles' state of charge is maximized at all times. This bounding case would minimize range anxiety, but is unrealistic from the point of view of both electric vehicle service equipment (EVSE) (i.e., charger) access, and plug-in behavior as it can result in dozens of charging sessions per week for battery electric vehicles (BEVs) that in reality are often only plugged in a few times per week.

Array↗

Assessing the release, transport, and retention of radioactive aerosols from hypothetical breaches in spent fuel storage canisters

Interim dry storage of spent nuclear fuel involves storing the fuel in welded stainless-steel canisters. Under certain conditions, the canisters could be subjected to environments that may promote stress corrosion cracking leading to a risk of breach and release of aerosol-sized particulate from the interior of the canister to the external environment through the crack. Research is currently under way by several laboratories to better understand the formation and propagation of stress corrosion cracks, however little work has been done to quantitatively assess the potential aerosol release. The purpose of the present work is to introduce a reliable generic numerical model for prediction of aerosol transport, deposition, and plugging in leak paths similar to stress corrosion cracks, while accounting for potential plugging from particle deposition. The model is dynamic (changing leak path geometry due to plugging) and it relies on the numerical solution of the aerosol transport equation in one dimension using finite differences. The model’s capabilities were also incorporated into a Graphical User Interface (GUI) that was developed to enhance user accessibility. Model validation efforts presented in this paper compare the model’s predictions with recent experimental data from Sandia National Laboratories (SNL) and results available in literature. We expect this model to improve the accuracy of consequence assessments and reduce the uncertainty of radiological consequence estimations in the remote event of a through-wall breach in dry cask storage systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

Shock-operated valve would automatically protect fluid systems

Glandless valve shuts down high-pressure fluid systems when severe shock from an explosion or earthquake occurs. The valve uses a pendulum to support the valve closure plug in the open position. When jarred, the valve body is moved relative to the pendulum and the plug support is displaced, allowing the plug to seat and be held by spring pressure.

Branum, L. W.↗

Gas turbine exhaust nozzle

An elongated hollow string is disposed in an exhaust nozzle combustion chamber and communicates with an air source through hollow struts at one end. The other end of the string is bell-mouth shaped and extends over the front portion of a nozzle plug. The bell-mouth may be formed by pivotally mounted flaps or leaves which are used to vary the exhaust throat area and the area between the plug and the leaves. Air from the engine inlet flows into the string and also between the combustion chamber and a housing disposed around the chamber. The air cools the plug and serves as a low velocity inner core of secondary gas to provide noise reduction for the primary exhaust gas while the other air, when it exits from the nozzle, forms an outer low velocity layer to further reduce noise. The structure produces increased thrust in a turbojet or turbofan engine.

Straight, D. M.↗

Thermocouple installation

A thermocouple assembly which includes a plug having a pair of small diameter holes near one end thereof which are spaced a small distance apart to leave a thin quantity of plug material between the holes is presented. There are a pair of thermocouple wires extending through the different holes and with the outer ends of the wires joined to the thin quantity of plug material which lies between the holes to form a thermocouple junction.

Powell, W. B.↗

Hydrogen-fueled diesel engine without timed ignition

Experiments were carried out to investigate the feasibility of converting a diesel engine to hydrogen-fueled operation without providing a timed ignition system. Use was made of a glow plug and a multiple-strike spark plug. The glow plug was found to provide reliable ignition and smooth engine operation. It caused the hydrogen to ignite almost immediately upon the start of injection. Indicated mean effective pressures were on the order of 1.3 MPa for equivalence ratios between 0.1 and 0.4 at a compression ratio of 18. This is significantly higher than the corresponding result obtained with diesel oil (about 0.6 MPa for equivalence ratios between 0.3 and 0.9). Indicated thermal efficiencies were on the order of 0.4 for hydrogen and 0.20-0.25 for diesel oil. Operation with the multiple-strike spark system yielded similar values for IMEP and efficiency, but gave rise to large cycle-to-cycle variations in the delay between the beginning of injection and ignition. Large ignition delays were associated with large amplitude pressure waves in the combustion chamber. The measured NO(x) concentrations in the exhaust gas were of the order of 50-100 ppm. This is significantly higher than the corresponding results obtained with premixed hydrogen and air at low equivalence ratios. Compression ignition could not be achieved even at a compression ratio of 29.