Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “photon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Effect of micron-scale manufacturing flaws on the tensile response of centimeter sized two-photon polymerization microlattices

Two-photon polymerization (TPP) is a unique fabrication technique that enables sub-micron scale resolution. Herein, we report on uniaxial tensile tests on millimeter-sized TPP log-pile structures that were fabricated using a recently developed interdigitated stitching strategy. As expected, the Young’s modulus increased with laser intensity, however elastic modulus, ultimate strength and strain-at-failure varied widely, even for nominally identical samples. Post-mortem analysis revealed a series of print defects resulting from various sources including misalignments, resin shrinkage, laser beam shadowing, and local depletion of the oxygen inhibitor. While some of the defects can be eliminated, such as misalignments due to insufficient precision of the mechanical stage, others are more intrinsic to TPP and thus more difficult to address.

36 MATERIALS SCIENCE↗

Dark Energy Studies with LSST using the Photon Simulator (Final Report)

This grant funded the development and dissemination of the Photon Simulator (PhoSim) for the purpose of studying dark energy at high precision with the upcoming Large Synoptic Survey Telescope (LSST) astronomical survey. The work was in collaboration with the Dark Energy Science Collaboration (DESC). Several detailed physics improvements were made in the optics, atmosphere and sensor, a number of validation studies were performed, and a significant number of usability features were implemented. Future work in DESC will use PhoSim as the image simulation tool for data challenges used by the analysis groups.

79 ASTRONOMY AND ASTROPHYSICS↗

The MicroBooNE Single-Photon Low-Energy Excess Search (Public Note 1087)

MicroBooNE is a short baseline neutrino experiment at Fermilab designed to address the low energy excess observed by the MiniBooNE experiment. This note describes and presents preliminary results for the MicroBooNE analysis developed to address this excess as a single photon plus one or zero protons in the final state. The analysis assumes neutrino neutral current Δ resonance production followed by Δ radiative decay on argon (NC Δ → Nγ ) as the "signal model"; event reconstruction and selection have been developed and optimized in order to maximize efficiency and reduce cosmogenic and other beam-related backgrounds to the NC Δ → Nγ signal. We present the analysis methodology and validation checks performed on limited-statistics open data sets, corresponding to 5 x10 19 protons on target (POT), following a blind analysis, as well as the projected sensitivities for testing the Standard Model (SM) predicted rate for the NC Δ → Nγ process and for testing the interpretation of the previously observed MiniBooNE low energy excess as NC Δ → Nγ events, using the full anticipated MicroBooNE data set of 12.25 x 10 20 POT.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First observation of the production of three massive vector bosons and search for long-lived particles using delayed photons in pp collisions at $\sqrt{s}=13\text{ TeV}$

This thesis presents the first observation of the production of three massive vector bosons (VVV with V = W, Z) in proton-proton collisions at the LHC at $\sqrt{s}=13\text{ TeV}$. The search was performed in final states with two same-sign charged leptons (electrons or muons) plus one or two jets, and three, four, five, or six leptons from WWW, WWZ, WZZ and ZZZ decays, with a data sample corresponding to an integrated luminosity of 137 fb -1 collected by the CMS experiment during 2016-2018. The observed (expected) significance of the combined VVV production is 5.7 (5.9) standard deviations, and the production cross section is measured to be 1010$^{+210}_{-200}$(stat) $^{+150}_{-120}$(syst) fb, corresponding to a signal strength of 1.02$^{+0.26}_{-0.23}$. We also found evidence for WWW and for WWZ production, with observed significances of 3.3 and 3.4 standard deviations, respectively. The measured production cross sections for individual VVV processes are also reported. The establishment of VVV production opens a new program of many standard model studies (such as gauge-gauge and Higgs-gauge couplings), and provides a new tool for many new physics searches (such as anomalous gauge coupling searches, new resonance searches). This thesis also reports a search for long-lived supersymmetry particles decaying to photons in proton-proton collisions at the LHC at $\sqrt{s} = 13 TeV$, with a data sample corresponding to an integrated luminosity of 77.4 fb -1 collected by CMS during 2016-2017. Results are interpreted with a gauge-mediated supersymmetry breaking model, where the long-lived particle is a neutralino and the lightest supersymmetry particle is a gravitino. For neutralino proper decay lengths of 0.1, 1, 10, and 100 m, masses up to 320, 525, 360, and 215 GeV are excluded at 95% confidence level, respectively. This result extends the limits from previous searches by one order of magnitude for the neutralino proper decay length and up to 100 GeV more for the neutralino mass. Motivated by the need for precision timing measurements for long-lived particle searches, as well as for improvements in general object reconstruction performance, the timing performance of two types of sensors are studied in this thesis: one with a Cerium doped Lutetium Yttrium Orthosilicate (LYSO:Ce) crystal as the scintillator and a silicon photomultiplier (SiPM) as the photodetector, another with a Cadmium-Telluride sensor as the active material for a sampling calorimeter. Both setups have been demonstrated with test beams to be able to provide timing measurements of particles with a resolution below 30 ps.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A New MCNP6 Electron-Photon Transport Validation Test: The Lockwood Energy Deposition Experiment (V.1.0)

This memo announces the availability of a new validation test for quantifying the accuracy of the MCNP6 electron-photon transport algorithm for use in energy-deposition calculations. Specifically, energy-deposition results are compared with the Lockwood energy-deposition experiment. The comparison includes energy-deposition profiles in a variety of different single-element materials including beryllium, aluminum, carbon, copper, iron, molybdenum, tantalum, and uranium for pencil beam electron sources with energies including 0.05-, 0.1-, 0.3-, 0.5, and 1-MeV and angles of incidence including normal, 30°, and 60° off-normal. The purpose of this memo is to discuss the contents of the Lockwood validation directory and to outline the procedure for generating the input files, running the tests, processing the results, and comparing results to the experimental and numerical benchmark. Each step is mostly automated by a makefile that executes the necessary perl script.

74 ATOMIC AND MOLECULAR PHYSICS↗

Photonic Doppler Velocimetry for Valve Analysis and Surveillance

This study is an experimental evaluation to measure and surveil the velocity of stainless steel (Carpenter 455) pistons within a forged 21-6-9 stainless steel valve body. The velocity of the piston “stroke” will be identified using Photonic Doppler Velocimetry (PDV). The piston velocity will be the measured variable of interest. The outcome of this testing series provides further understanding to whether the extracted piston velocity can provide enough information to determine valve integrity. PDV has been identified as a diagnostic of interest as it can detect surface motion at high speeds with reliable accuracy. Through preliminary studies conducted with velocity interferometer system for any reflector (VISAR), the velocity of the piston is expected to stroke with a speed of 135 m/s. The PDV technique is much more reliable and repeatable than the VISAR technique because of its high-speed precision and accuracy, so it will not only validate the preliminary data, but also provide a testing technique that is capable of being used in future valve qualification efforts. The initial testing was completed using valves that were assembled per qualified procedures in a pristine condition. These initial tests were conducted to provide baseline data. This baseline data was then compared to data collected from valves where man-made defects were introduced. These defects are discussed in later sections. Lastly, actuators used to operate the valves were loaded with varied amounts of high explosives to identify if velocity is a function of the amount of explosive in an actuator. These parameters were adjusted to conclusively determine and identify if PDV can be used as a method to assess valve integrity. It was concluded through the testing discussed in this paper that in fact, PDV is capable of measuring the differences in piston velocities based on varied parameters. As far as understanding the PDV accuracy of the measured differences, this is ongoing and will have to be assessed in continued testing series.

42 ENGINEERING↗

Three-Photon Optical Pumping for Trapped Ion Quantum Computing

In this report we describe the testing of a novel scheme for state preparation of trapped ions in a quantum computing setup. This technique optimally would allow for similar precision and speed of state preparation while allowing for individual addressability of single ions in a chain using technology already available in a trapped ion experiment. As quantum computing experiments become more complicated, mid-experiment measurements will become necessary to achieve algorithms such as quantum error correction. Any mid-experiment measurement then requires the measured qubit to be re-prepared to a known quantum state. Currently this involves the protected qubits to be moved a sizeable distance away from the qubit being re-prepared which can be costly in terms of experiment length as well as introducing errors. Theoretical calculations predict that a three-photon process would allow for state preparation without qubit movement with similar efficiencies to current state preparation methods.

97 MATHEMATICS AND COMPUTING↗

Synthesis and Photonic Sintering of Proton Conducting Lanthanide Nickelates

Lanthanide nickelate perovskites are known proton conductors at intermediate temperatures (350-600°C). They are attractive targets for proton conducting fuel cells and electrolyzers due to their operational temperature range and their stability in the presence of CO 2 . These materials have the formula LNiO 3 , with the lanthanide L = La, Ce, Pr, Nd, or Sm. Sintering is challenging due to phase transformations that occur at lower temperatures than those required for sintering. In this project, a series of lanthanide nickelate perovskites was synthesized via both a precursor solid solution method and the glycine nitrate process. Powders derived from the precursor solid solution method for LaNiO 3 and NdNiO 3 were sintered at Utility Global Inc. at various temperatures utilizing fast photonic sintering. LaNiO 3 was successfully sintered while maintaining the perovskite phase. NdNiO 3 underwent a phase transformation at all the conditions tested. The stability of the perovskite phase decreases moving right across the lanthanides in the periodic table, while the expected proton conductivity increases. These results will inform further investigations into lanthanide nickelate perovskites toward the goal of producing a free-standing, sintered, proton-conducting membrane.

36 MATERIALS SCIENCE↗

Single-Photon Detector & Counter for Transduction

Over the recent years, quantum computers have procured the attention of the public, largely due to their fast factoring capabilities and potential for efficient simulation of quantum dynamics \cite{RevModPhys.79.135}. This interest, coupled with advances in quantum transduction, could lead to the realization of a quantum distributed network, effectively linking dilution fridges across vast distances. Presently, there are several qubit systems developed for encoding quantum information. They primarily fall into two categories: those exploiting optical frequencies for excitation, and those operating at microwave frequencies. Optical frequency qubit systems include trapped ions, neutral atoms, quantum dots, and solid-state defects. Microwave frequency qubit system encompass superconducting qubits (transmon) and spins in crystals. Among these, transmons are particularly intriguing due to their low-loss of photons at microwave frequencies. The Josephson effect within a superconducting circuit enables high-fidelity quantum operations \cite{Microwave-optical_quantum_frequency_conversion}. Thus, it is non-trivial to develop an apparatus for efficiently bridging microwave and optical frequency regimes.

Bautista-Cortezano, Pablo↗

FY23 Status Report of the Activated Materials Laboratory at the Advanced Photon Source

The Activated Materials Laboratory (AML) is a new radiological facility located at the Advanced Photon Source (APS) in Argonne National Laboratory (ANL), adjacent to the high-energy x-ray microscopy (HEXM) beamline in the long beamline building (LBB) constructed under the APS-upgrade (APS-U) project. The AML is a centralized facility to facilitate the safe conduct of experiments on activated materials at the APS. This report provides an overview of the status of the AML as a Nuclear Science User Facilities (NSUF) partner user facility in preparation for the general user access in 2024 upon the commissioning of the APS-U beamlines. Specifically, details are provided regarding the laboratory's scope, functionality, components, operational blueprint, and data management approach. The plans on augmenting the instrumentation, refining operational procedures and developing a robust data management strategy for FY24 and beyond are also discussed.

43 PARTICLE ACCELERATORS↗

Abstract for CRADA between National Energy Technology Laboratory and TOPTICA Photonics, Inc.

The National Energy Technology Laboratory (NETL) and Toptica Photonics (Participant) will collaborate to demonstrate the application of a frequency-comb laser (dual-comb spectroscopy) in an optically accessible rotating detonation engine (RDE). RDEs are a next-generation energy conversion technology which are well-suited to hydrogen usage and have the potential to significantly increase the efficiency of gas turbine engine power cycles. However, critical information is needed about the high temperature and pressure detonation wave, which represents an extremely challenging diagnostic environment. Dual-comb spectroscopy can be used to characterize the pressure-broadened IR absorption features at MHz rates, providing information not possible with conventional tunable diode laser (TDL) technologies. This collaboration will, for the first time, demonstrate application of dual-comb spectroscopy within the combustion annulus of a hydrogen-air RDE. If successful, the data generated will help to accelerate commercialization of RDE technologies in support of decarbonizing our nation’s energy sector.

08 HYDROGEN↗

The MicroBooNE Single-Photon Low-Energy Excess Search

MicroBooNE is a short baseline neutrino experiment at Fermilab designed to address the low energy excess observed by the MiniBooNE experiment. This note describes and presents preliminary results for the MicroBooNE analysis developed to address this excess as a single photon plus one or zero protons in the final state. The analysis assumes neutrino neutral current Δ resonance production followed by Δ radiative decay on argon (NC Δ → $N_γ$) as the “signal model”; event reconstruction and selection have been developed and optimized in order to maximize efficiency and reduce cosmogenic and other beam-related backgrounds to the NC Δ → $N_γ$ signal. We present the analysis methodology and validation checks performed on limited-statistics open data sets, corresponding to 5×10 19 protons on target (POT), following a blind analysis, as well as the projected sensitivities for testing the Standard Model (SM) predicted rate for the NC Δ → $N_γ$ process and for testing the interpretation of the previously observed MiniBooNE low energy excess as NC Δ → $N_γ$ events, using the full anticipated MicroBooNE data set of 12.25×10 20 POT.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon Doppler Velocimetry to Spatially Resolve Plasma Density in a Power Flow Gap

The understanding of power flow plasmas is important as we look towards next generation pulsed power (NGPP) as current losses could prohibit the goals of that facility. Therefore, it is important to have accurate diagnostics of the plasma parameters on the current machines, which can be used to help inform and improve simulations. Having these plasma parameters will help validate models and simulations to provide confidence when they are expanded to conditions relevant to NGPP. One important plasma parameter that can be measured is the electron density, which can be measured by photonic Doppler velocimetry (PDV). A PDV system has several key advantages over other interferometers by measuring relatively low densities (> 1 × 10 15 cm -2 ) with both spatial and temporal resolution. Experiments were performed on the Mykonos pulsed power machine, which is a 1 MA sub scale machine in which recent platforms have been developed to explore current densities relevant to the inner magnetically insulated transmission line (MITL) on the Z machine. Experiments were performed on two different platforms, the thin foil platform and the Mykonos parallel plate platform (MP3). In addition, a combination of both single-point and multi-point measurements were used. The single-point measurements proved to be very promising, providing a clear increase in density at about 70 ns into the current rise on thin foil experiments up to about 5 × 10 17 cm -3 before the probe stopped providing signal. While we did also see returns from multi-point measurements on both platforms, the signals were not as easy to interpret due to strong background effects. However, they do show initial promise for this diagnostic to measure density at several points across a 1 mm gap. These measurements provide insights in how to improve the diagnostic so that it can provide useful information on power flow relevant experiments.

47 OTHER INSTRUMENTATION↗