Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Evaluation of truncation error and adaptive grid generation for the transonic full potential flow calculations

The effects of truncation error on the numerical solution of transonic flows using the full potential equation are studied. The effects of adapting grid point distributions to various solution aspects including shock waves is also discussed. A conclusion is that a rapid change of grid spacing is damaging to the accuracy of the flow solution. Therefore, in a solution adaptive grid application an optimal grid is obtained as a tradeoff between the amount of grid refinement and the rate of grid stretching.

Nakamura, S.↗

Numerical optimization in Hilbert space using inexact function and gradient evaluations

Trust region algorithms provide a robust iterative technique for solving non-convex unstrained optimization problems, but in many instances it is prohibitively expensive to compute high accuracy function and gradient values for the method. Of particular interest are inverse and parameter estimation problems, since function and gradient evaluations involve numerically solving large systems of differential equations. A global convergence theory is presented for trust region algorithms in which neither function nor gradient values are known exactly. The theory is formulated in a Hilbert space setting so that it can be applied to variational problems as well as the finite dimensional problems normally seen in trust region literature. The conditions concerning allowable error are remarkably relaxed: relative errors in the gradient error condition is automatically satisfied if the error is orthogonal to the gradient approximation. A technique for estimating gradient error and improving the approximation is also presented.

Carter, Richard G.↗

On the possibility of observing cosmic ray sources in high energy gamma rays

If cosmic rays are accelerated by strong shocks, then cosmic ray sources should be characterized by spectra, dN/dE alpha E exp -(2.0-2.2), reflecting the strength of those shocks. This is expected from the 'standard leaky box' model of cosmic ray propagation in which the source spectra are harder than the observed spectra because higher energy particles have shorter residence times in the galactic magnetic fields. Furthermore, data on cosmic ray nucleons suggest that these sources might be surrounded by material. If the latter is true, such sources should be observable in gamma rays at energies beyond 1 GeV where the angular resolution of gamma-ray telescopes is optimized and the background is significantly reduced. For identified sources, the source location accuracy can be shown to improve with increasing energy in spite of the decreasing statistics, as long as the gamma-ray spectrum is harder than dN/dE alpha E exp -gamma. A Monte Carlo model is used to predict the photon spectra which would be expected from cosmic ray sources under varying assumptions about the strength of the shocks in the acceleration region.

Ormes, J. F.↗

Extended Finite Element Based Approach in Additive Manufacturing Modeling for Optimizing Highly Complex Manifold in Protonic Ceramic Electrochemical Cells

The objective of this project is to develop a novel numerical approach based on the extended finite element method (XFEM) for modeling moving boundaries of material deposited in additive manufacturing (AM) process with improved accuracy and reduced computational cost. One of the major challenges in simulating AM processes is that the boundaries of the computational domain need to change as material is deposited. Previous approaches have achieved this by activating new finite elements, but this requires a high level of mesh refinement to capture small movement of the boundary. XFEM allows the solution boundary to move independently of the mesh, permitting smooth representation of the evolution of the boundary as material is deposited. As a result, this new method will significantly improve the simulation accuracy while reducing the computational cost compared with existing approaches. Furthermore, this project will bring significant improvements for the design and AM process optimization in an iterative fashion among numerical simuation, parameter optimization, and experimental validation. Specifically, this project will support the protonic ceramic electrochemical cells (PCEC) stack development at INL by providing insights into the density, residual stress, thermal and mechanical properties of the PCEC manifold and interconnect, which is critical in enhancing the system lifetime and reducing the overall cost. Upon the success of proposed development and validation of the proposed approach, simulation will be applied to determine an optimal set of AM process parameters for the PCEC manifold production. This project will consolidate Idaho National Laboratory (INL)’s simulation capabilities provided by the MOOSE framework and the Valhalla AM simulation application, with encouraging expansion to emerging PCEC applications and AM technologies at INL and beyond.

97 MATHEMATICS AND COMPUTING↗

Enhancing EV Motor Design Through Knowledge-Based AI and Hierarchical Fuzzy Logic Model

This work presents a novel approach to optimizing electric vehicle motor design through the integration of Knowledge-Based Artificial Intelligence (KB-AI) and Hierarchical Fuzzy Logic. Traditional motor design processes are time-intensive, relying heavily on iterative simulations and domain-specific expertise. These processes are further complicated by the nonlinear relationships between key design parameters. The proposed framework addresses these challenges by systematically encoding expert knowledge from scientific literature into a fuzzy logic system, allowing for the efficient handling of complex design variables. The hierarchical fuzzy logic model reduces computational complexity by decomposing the nonlinear relationships into manageable rule sets while maintaining design accuracy. The proposed methodology was applied to the design of a 100 kW motor, yielding optimal values for key parameters. This resulted in a compact motor design with a volume of 2.2 liters, showcasing the framework’s ability to deliver high-performance, application-specific motor configurations.

Kumar, Praveen [ORNL] (ORCID:0000000291877857)↗

Ares I Flight Control System Design

The Ares I launch vehicle represents a challenging flex-body structural environment for flight control system design. This paper presents a design methodology for employing numerical optimization to develop the Ares I flight control system. The design objectives include attitude tracking accuracy and robust stability with respect to rigid body dynamics, propellant slosh, and flex. Under the assumption that the Ares I time-varying dynamics and control system can be frozen over a short period of time, the flight controllers are designed to stabilize all selected frozen-time launch control systems in the presence of parametric uncertainty. Flex filters in the flight control system are designed to minimize the flex components in the error signals before they are sent to the attitude controller. To ensure adequate response to guidance command, step response specifications are introduced as constraints in the optimization problem. Imposing these constraints minimizes performance degradation caused by the addition of the flex filters. The first stage bending filter design achieves stability by adding lag to the first structural frequency to phase stabilize the first flex mode while gain stabilizing the higher modes. The upper stage bending filter design gain stabilizes all the flex bending modes. The flight control system designs provided here have been demonstrated to provide stable first and second stage control systems in both Draper Ares Stability Analysis Tool (ASAT) and the MSFC 6DOF nonlinear time domain simulation.

Jang, Jiann-Woei↗

Verification and validation of developed short-term forecasting models

Recent advancements in machine learning (ML) and artificial intelligence (AI) technologies provide an opportunity for leveraging data-driven algorithms to predict future nuclear power plant (NPP) operating conditions by using recorded plant process data. Successfully implementing these models can lead to cost-reducing, conditioned-based predictive maintenance through optimized maintenance schedules and a reduction of unnecessary maintenance activities. This report discusses the verification and validation of short-term forecasting processes (i.e., data cleaning, feature selection, model optimization, and forecasting) developed in previous reports. The verification and validation (V&V) process demonstrates the expected precision and accuracy when the ML model encounters new datasets from different systems. Shapley additive explanations were used as the primary means of feature selection across these different data set. Individual models were trained for each data set, then validated through a cross-validation procedure. In this report, two different ML models were tasked to predict variables from three different plant process data sets with varying prediction horizons. The results indicate that support vector regression (SVR) outperformed long short-term memory (LSTM) neural networks in regard to each data set and each prediction horizon in this study, but further tuning and optimization could improve long short-term memory results. However, each forecasting model showed reduced performance as the prediction horizon was extended from 1 hour to 1 day ahead. Research is ongoing to evaluate the optimal input variable space, which is based on a given set of process parameters, to further improve forecasting accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multigrid nonoscillatory method for computing high speed flows

A multigrid method using different smoothers has been developed to solve the Euler equations discretized by a nonoscillatory scheme up to fourth order accuracy. The best smoothing property is provided by a five-stage Runge-Kutta technique with optimized coefficients, yet the most efficient smoother is a backward Euler technique in factored and diagonalized form. The singlegrid solution for a hypersonic, viscous conic flow is in excellent agreement with the solution obtained by the third order MUSCL and Roe's method. Mach 8 inviscid flow computations for a complete entry probe have shown that the accuracy is at least as good as the symmetric TVD scheme of Yee and Harten. The implicit multigrid method is four times more efficient than the explicit multigrid technique and 3.5 times faster than the single-grid implicit technique. For a Mach 8.7 inviscid flow over a blunt delta wing at 30 deg incidence, the CPU reduction factor from the three-level multigrid computation is 2.2 on a grid of 37 x 41 x 73 nodes.

Li, C. P.↗

Mutual-information based optimal experimental design for hyperpolarized $$^{13}$$C-pyruvate MRI

Abstract A key parameter of interest recovered from hyperpolarized (HP) MRI measurements is the apparent pyruvate-to-lactate exchange rate, $$k_{{\textrm PL}}$$ k P L , for measuring tumor metabolism. This manuscript presents an information-theory-based optimal experimental design approach that minimizes the uncertainty in the rate parameter, $$k_{{\textrm PL}}$$ k P L , recovered from HP-MRI measurements. Mutual information is employed to measure the information content of the HP measurements with respect to the first-order exchange kinetics of the pyruvate conversion to lactate. Flip angles of the pulse sequence acquisition are optimized with respect to the mutual information. A time-varying flip angle scheme leads to a higher parameter optimization that can further improve the quantitative value of mutual information over a constant flip angle scheme. However, the constant flip angle scheme, 35 and 28 degrees for pyruvate and lactate measurements, leads to an accuracy and precision comparable to the variable flip angle schemes obtained from our method. Combining the comparable performance and practical implementation, optimized pyruvate and lactate flip angles of 35 and 28 degrees, respectively, are recommended.

97 MATHEMATICS AND COMPUTING↗

Optimizing near real time accountability for reprocessing.

Near Real Time Accountability (NRTA) of actinides at high precision in reprocessing plants has been a long sought-after goal in the safeguards community. Achieving this goal is hampered by the difficulty of making precision measurements in the reprocessing environment, equipment cost, and impact to plant operations. Thus the design of future reprocessing plants requires an optimization of different approaches. The Separations and Safeguards Performance Model, developed at Sandia National Laboratories, was used to evaluate a number of NRTA strategies in a UREX+ reprocessing plant. Strategies examined include the incorporation of additional actinide measurements of internal plant vessels, more use of process monitoring data, and the option of periodic draining of inventory to key tanks. Preliminary results show that the addition of measurement technologies can increase the overall measurement uncertainty due to additional error propagation, so care must be taken when designing an advanced system. Initial results also show that relying on a combination of different NRTA techniques will likely be the best option. The model provides a platform for integrating all the data. The modeling results for the different NRTA options under various material loss conditions will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Inexact Newton-CG algorithms with complexity guarantees

Abstract We consider variants of a recently developed Newton-CG algorithm for nonconvex problems (Royer, C. W. & Wright, S. J. (2018) Complexity analysis of second-order line-search algorithms for smooth nonconvex optimization. SIAM J. Optim., 28, 1448–1477) in which inexact estimates of the gradient and the Hessian information are used for various steps. Under certain conditions on the inexactness measures, we derive iteration complexity bounds for achieving $\epsilon $-approximate second-order optimality that match best-known lower bounds. Our inexactness condition on the gradient is adaptive, allowing for crude accuracy in regions with large gradients. We describe two variants of our approach, one in which the step size along the computed search direction is chosen adaptively, and another in which the step size is pre-defined. To obtain second-order optimality, our algorithms will make use of a negative curvature direction on some steps. These directions can be obtained, with high probability, using the randomized Lanczos algorithm. In this sense, all of our results hold with high probability over the run of the algorithm. We evaluate the performance of our proposed algorithms empirically on several machine learning models. Our approach is a first attempt to introduce inexact Hessian and/or gradient information into the Newton-CG algorithm of Royer & Wright (2018, Complexity analysis of second-order line-search algorithms for smooth nonconvex optimization. SIAM J. Optim., 28, 1448–1477).

Mathematics↗

Automated registration of multispectral MR vessel wall images of the carotid artery

Purpose: Atherosclerosis is the primary cause of heart disease and stroke. The detailed assessment of atherosclerosis of the carotid artery requires high resolution imaging of the vessel wall using multiple MR sequences with different contrast weightings. These images allow manual or automated classification of plaque components inside the vessel wall. Automated classification requires all sequences to be in alignment, which is hampered by patient motion. In clinical practice, correction of this motion is performed manually. Previous studies applied automated image registration to correct for motion using only nondeformable transformation models and did not perform a detailed quantitative validation. The purpose of this study is to develop an automated accurate 3D registration method, and to extensively validate this method on a large set of patient data. In addition, the authors quantified patient motion during scanning to investigate the need for correction. Methods: MR imaging studies (1.5T, dedicated carotid surface coil, Philips) from 55 TIA/stroke patients with ipsilateral <70% carotid artery stenosis were randomly selected from a larger cohort. Five MR pulse sequences were acquired around the carotid bifurcation, each containing nine transverse slices: T1-weighted turbo field echo, time of flight, T2-weighted turbo spin-echo, and pre- and postcontrast T1-weighted turbo spin-echo images (T1W TSE). The images were manually segmented by delineating the lumen contour in each vessel wall sequence and were manually aligned by applying throughplane and inplane translations to the images. To find the optimal automatic image registration method, different masks, choice of the fixed image, different types of the mutual information image similarity metric, and transformation models including 3D deformable transformation models, were evaluated. Evaluation of the automatic registration results was performed by comparing the lumen segmentations of the fixed image and moving image after registration. Results: The average required manual translation per image slice was 1.33 mm. Translations were larger as the patient was longer inside the scanner. Manual alignment took 187.5 s per patient resulting in a mean surface distance of 0.271 ± 0.127 mm. After minimal user interaction to generate the mask in the fixed image, the remaining sequences are automatically registered with a computation time of 52.0 s per patient. The optimal registration strategy used a circular mask with a diameter of 10 mm, a 3D B-spline transformation model with a control point spacing of 15 mm, mutual information as image similarity metric, and the precontrast T1W TSE as fixed image. A mean surface distance of 0.288 ± 0.128 mm was obtained with these settings, which is very close to the accuracy of the manual alignment procedure. The exact registration parameters and software were made publicly available. Conclusions: An automated registration method was developed and optimized, only needing two mouse clicks to mark the start and end point of the artery. Validation on a large group of patients showed that automated image registration has similar accuracy as the manual alignment procedure, substantially reducing the amount of user interactions needed, and is multiple times faster. In conclusion, the authors believe that the proposed automated method can replace the current manual procedure, thereby reducing the time to analyze the images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multipole Expansion of Atomic Electron Density Fluctuation Interactions in the Density-Functional Tight-Binding Method

The accuracy of the density-functional tight-binding (DFTB) method in describing noncovalent interactions is limited due to its reliance on monopole-based spherical charge densities. In this study, we present a multipole-extended second-order DFTB (mDFTB2) method that takes into account atomic dipole and quadrupole interactions. Furthermore, we combine the multipole expansion with the monopole-based third-order contribution, resulting in the mDFTB3 method. To assess the accuracy of mDFTB2 and mDFTB3, we evaluate their performance in describing noncovalent interactions, proton transfer barriers, and dipole moments. Here, our benchmark results show promising improvements even when using the existing electronic parameters optimized for the original DFTB3 model. Both mDFTB2 and mDFTB3 outperform their monopole-based counterparts, DFTB2 and DFTB3, in terms of accuracy. While mDFTB2 and mDFTB3 perform comparably for neutral and positively charged systems, mDFTB3 exhibits superior performance over mDFTB2 when dealing with negatively charged systems and proton transfers. Overall, the incorporation of the multipole expansion significantly enhances the accuracy of the DFTB method in describing noncovalent interactions and proton transfers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-T-266: Development of Evaluation System of Optimal Synchrotron Controlling Parameter for Spot Scanning Proton Therapy with Multiple Gate Irradiations in One Operation Cycle

Purpose: We have developed a gated spot scanning proton beam therapy system with real-time tumor-tracking. This system has the ability of multiple-gated irradiation in a single synchrotron operation cycle controlling the wait-time for consecutive gate signals during a flat-top phase so that the decrease in irradiation efficiency induced by irregular variation of gate signal is reduced. Our previous studies have shown that a 200 ms wait-time is appropriate to increase the average irradiation efficiency, but the optimal wait-time can vary patient by patient and day by day. In this research, we have developed an evaluation system of the optimal wait-time in each irradiation based on the log data of the real-time-image gated proton beam therapy (RGPT) system. Methods: The developed system consists of logger for operation of RGPT system and software for evaluation of optimal wait-time. The logger records timing of gate on/off, timing and the dose of delivered beam spots, beam energy and timing of X-ray irradiation. The evaluation software calculates irradiation time in the case of different wait-time by simulating the multiple-gated irradiation operation using several timing information. Actual data preserved in the log data are used for gate on and off time, spot irradiation time, and time moving to the next spot. Design values are used for the acceleration and deceleration times. We applied this system to a patient treated with the RGPT system. Results: The evaluation system found the optimal wait-time of 390 ms that reduced the irradiation time by about 10 %. The irradiation time with actual wait-time used in treatment was reproduced with accuracy of 0.2 ms. Conclusion: For spot scanning proton therapy system with multiple-gated irradiation in one synchrotron operation cycle, an evaluation system of the optimal wait-time in each irradiation based on log data has been developed. Funding Support: Japan Society for the Promotion of Science (JSPS) through the FIRST Program.

60 APPLIED LIFE SCIENCES↗

WE-A-BRF-01: Dual-Energy CT Imaging in Diagnostic Imaging and Radiation Therapy

The quantification accuracy of dual-energy imaging is influenced by the fundamentals of x-ray physics, system geometry, data acquisition hardware/protocol, system calibration, and image processing technique. This symposium will provide updates on the following advanced application areas: Mammography. Volumetric breast density techniques based on standard mammograms require estimation of breast thickness, which is difficult to accurately measure. By comparison, calculation of breast density using dual energy mammography does not require measurement of breast thickness. Dual energy mammography has been implemented using both energy integrating flat panel detectors in conjunction with beam energy switching and energy resolved photon counting detectors. These techniques have been optimized using simulation studies and validated using physical phantoms and postmortem breasts. Chemical decomposition was used as the gold standard for volumetric breast density measurement in postmortem breasts. Breast density measurements have also been compared with results from four-category BI-RADS density rankings, standard image thresholding and Fuzzy k-mean clustering techniques. These studies indicate that dual energy mammography can be used to accurately measure volumetric breast density. Cardiovascular CT. The predicative accuracy of risk models for recurrent stroke and cardiac arrest depends heavily on accurate differentiation of thrombus or calcium from iodine in left atrial appendage or coronary arteries. The amount of energy separation is constrained by image noise; therefore, optimal kVp, beam filtration, and balanced flux are essential for the quantification accuracy of iodine and calcium. The basis materials are combined linearly to generate monochromatic energy images, where CT# accuracy and CNR are energy dependent. With optimal monochromatic energy, the mean iodine concentration for the thrombus, circulatory stasis, and control groups are significantly different. Risk classification based on calcium scores shows excellent agreement with classification on the basis of conventional coronary artery calcium scoring. These studies demonstrate dual-energy cardiovascular CT can potentially be a noninvasive and sensitive modality in high risk patients. On-board KV/MV Imaging. To enhance soft tissue contrast and reduce metal artifacts, we have developed a dual-energy CBCT technique and a novel on-board kV/MV imaging technique based on hardware available on modern linear accelerators. We have also evaluated the feasibility of these two techniques in various phantom studies. Optimal techniques (energy, beam filtration, # of overlapping projections, etc) have been investigated with unique calibration procedures, which leads to successful decomposition of imaged material into acrylic-aluminum basis material pair. This enables the synthesis of virtual monochromatic (VM) CBCT images that demonstrate much less beam hardening, significantly reduced metal artifacts, and/or higher soft tissue CNR compared to single-energy CBCT. Adaptive Radiation Therapy. DECT could actually contribute to the area of Dose-Guided Radiation Therapy (or Adaptive Therapy). The application of DECT imaging using 80kV and 140 kV combinations could potentially increase the image quality by reducing the bone or high density material artifacts and also increase the soft tissue contrast by a light contrast agent. The result of this higher contrast / quality images is beneficial for deformable image registration / segmentation algorithm to improve its accuracy hence to make adaptive therapy less time consuming in its recontouring process. The real time re-planning prior to per treatment fraction could become more realistic with this improvement especially in hypofractional SBRT cases. Learning Objectives: Learn recent developments of dual-energy imaging in diagnosis and radiation therapy; Understand the unique clinical problem and required quantification accuracy in each application; Understand the different approaches to optimize dual-energy imaging techniques for different applications.

60 APPLIED LIFE SCIENCES↗

Multidimensional sum-up rounding for integer programming in optimal experimental design

Here we present a numerical method for approximating the solution of convex integer programs stemming from optimal experimental design. The statistical setup consists of a Bayesian framework for linear inverse problems for which the direct relationship is described by a discretized integral equation. Specifically, we aim to find the optimal sensor placement from a set of candidate locations where data are collected with measurement error. The convex objective function is a measure of the uncertainty, described here by the trace or log-determinant of the posterior covariance matrix, for the discretized linear inverse problem solution. The resulting convex integer program is relaxed, producing a lower bound. An upper bound is obtained by extending the sum-up rounding approach to multiple dimensions. For this extension, we analyze its accuracy as a function of the discretization mesh size for a rectangular domain. We show asymptotic optimality of the integer solution defining the upper bound for different experimental design criteria (A- and D-optimal), by proving the convergence to zero of the gap between the upper and lower bounds as the mesh size goes to zero. The technique is illustrated on a two-dimensional gravity surveying problem for both A-optimal and D-optimal sensor placement where our designs yield better results compared with a thresholding rounding approach.

97 MATHEMATICS AND COMPUTING↗

BENCHMARK TESTS FOR MARKOV CHAIN MONTE CARLO FITTING OF EXOPLANET ECLIPSE OBSERVATIONS

Ground-based observations of exoplanet eclipses provide important clues to the planets' atmospheric physics, yet systematics in light curve analyses are not fully understood. It is unknown if measurements suggesting near-infrared flux densities brighter than models predict are real, or artifacts of the analysis processes. We created a large suite of model light curves, using both synthetic and real noise, and tested the common process of light curve modeling and parameter optimization with a Markov Chain Monte Carlo algorithm. With synthetic white noise models, we find that input eclipse signals are generally recovered within 10% accuracy for eclipse depths greater than the noise amplitude, and to smaller depths for higher sampling rates and longer baselines. Red noise models see greater discrepancies between input and measured eclipse signals, often biased in one direction. Finally, we find that in real data, systematic biases result even with a complex model to account for trends, and significant false eclipse signals may appear in a non-Gaussian distribution. To quantify the bias and validate an eclipse measurement, we compare both the planet-hosting star and several of its neighbors to a separately chosen control sample of field stars. Re-examining the Rogers et al. Ks-band measurement of CoRoT-1b finds an eclipse 3190{sup +370}{sub -440} ppm deep centered at {phi}{sub me} = 0.50418{sup +0.00197}{sub -0.00203}. Finally, we provide and recommend the use of selected data sets we generated as a benchmark test for eclipse modeling and analysis routines, and propose criteria to verify eclipse detections.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimum element density studies for finite-element thermal analysis of hypersonic aircraft structures

Different finite element models previously set up for thermal analysis of the space shuttle orbiter structure are discussed and their shortcomings identified. Element density criteria are established for the finite element thermal modelings of space shuttle orbiter-type large, hypersonic aircraft structures. These criteria are based on rigorous studies on solution accuracies using different finite element models having different element densities set up for one cell of the orbiter wing. Also, a method for optimization of the transient thermal analysis computer central processing unit (CPU) time is discussed. Based on the newly established element density criteria, the orbiter wing midspan segment was modeled for the examination of thermal analysis solution accuracies and the extent of computation CPU time requirements. The results showed that the distributions of the structural temperatures and the thermal stresses obtained from this wing segment model were satisfactory and the computation CPU time was at the acceptable level. The studies offered the hope that modeling the large, hypersonic aircraft structures using high-density elements for transient thermal analysis is possible if a CPU optimization technique was used.

Ko, William L.↗