Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Effect of flight loads on turbofan engine performance deterioration

A significant percentage of high-bypass-ratio turbofan engine performance deterioration is caused by an increase in operating clearance between fan/compressor and turbine blades and their outer air seals. These increased clearances result from rubs induced by a combination of engine power transients and aircraft flight loads. An analytical technique for predicting the effect of quasi-steady state aircraft flight loads on engine performance deterioration has been developed and is presented. Thrust, aerodynamic and inertia loads are considered. Analytical results are shown and compared to actual engine test experience.

Stakolich, E. G.↗

Tension-mode loading for bend specimens in cryogens

Special fixture permits use of tension-loading apparatus in fracture-toughness tests on standard bend specimens. Specimen is held in place by spacer blocks and wire clips. Central, load-application roller bends specimen between lateral, reaction-load rollers.

Pierce, W. S.↗

Characteristics of lightly loaded fan rotor blade wakes

Low subsonic and incompressible wake flow downstream of lightly loaded rotor was studied. Measurements of mean velocity, turbulence intensity, Reynolds stress, and static variations across the rotor wake at various axial and radial locations were investigated. Wakes were measured at various rotor blade incidences to discern the effect of blade loading on the rotor wake. Mean velocity and turbulence measurements were carried out with a triaxial hot wire probe both rotating with the rotor and stationary behind the rotor. Results indicate that increased loading slows the decay rates of axial and tangential mean velocity defects and radial velocities in the wake. The presence of large radial velocities in the rotor wake indicate the extent of the interactions between one radius and another. Appreciable static pressure variations across the rotor wake were found in the near wake region. Similarity in the profile shape was found for the axial and tangential components of the mean velocity and in the outer layer for axial, tangential, and radial turbulence intensities.

Reynolds, B.↗

Analysis of surface cracks in finite plates under tension or bending loads

Stress-intensity factors calculated with a three-dimensional, finite-element analysis for shallow and deep semielliptical surface cracks in finite elastic isotropic plates subjected to tension or bending loads are presented. A wide range of configuration parameters was investigated. The ratio of crack depth to plate thickness ranged from 0.2 to 0.8 and the ratio of crack depth to crack length ranged from 0.2 to 2.0. The effects of plate width on stress-intensity variations along the crack front was also investigated. A wide-range equation for stress-intensity factors along the crack front as a function of crack depth, crack length, plate thickness, and plate width was developed for tension and bending loads. The equation was used to predict patterns of surface-crack growth under tension or bending fatigue loads. A modified form of the equation was also used to correlate surface-crack fracture data for a brittle epoxy material within + or - 10 percent for a wide range of crack shapes and crack sizes.

Newman, J. C., Jr.↗

Dielectric-loaded waveguide circulator for cryogenically cooled and cascaded maser waveguide structures

A dielectrically loaded four port waveguide circulator is used with a reflected wave maser connected to a second port between first and third ports to form one of a plurality of cascaded maser waveguide structures. The fourth port is connected to a waveguide loaded with microwave energy absorbing material. The third (output signal) port of one maser waveguide structure is connected by a waveguide loaded with dielectric material to the first (input) port of an adjacent maser waveguide structure, and the second port is connected to a reflected wave maser by a matching transformer which passes the signal to be amplified into and out of the reflected wavemaser and blocks pumping energy in the reflected wave maser from entering the circulator. A number of cascaded maser waveguide structures are thus housed in a relatively small volume of conductive material placed within a cryogenically cooled magnet assembly.

Clauss, R. C.↗

Effect of graded physical load on the state of the liver from morphometric data and biochemical blood indices of rats against a background of hypokinesia

Tests were conducted on 100 sexually immature inbred August and Wistar male rats in order to determine the effects hypokinesia, physical load and phenamine on the liver. Weight and linear dimension fell in hypokinesia; total serum protein lowered and aldolase and cholesterol and beta-lipoprotein levels rose. Blood sugar content rose and liver glycogen fell. Interlinear differences of these indices are found. Rehabilitated physical loading against hypokinesia background diminished and at times completely prevented its negative effect. Extent of correction depended on animal species. Evidence of genotypical conditionality of organism adaptation to physical load in hypokinesia was found.

Nikityuk, B. A.↗

A Study of Panel Loads and Centers of Pressure of Three Different Cruciform Aft-Tail Control Surfaces of a Wingless Missile from Mach 1.60 to 3.70

An investigation was made of the forces and moments on the cruciform aft-tail control surfaces of a wingless missile model to determine the variation of panel load and center of pressure with angle of attack, tail deflection, model roll angle, and Mach number. Also, a limited force-moment and surface-pressure investigation was made on a noncircular aft end. These investigations were made in a unitary plan wind tunnel at Mach numbers of 1.60, 2.36, and 3.70 and at a Reynolds number per meter of 6,600,000. The cruciform aft-tail results indicate very little variation in the center of pressure for the highly loaded windward tail. The noncircular aft-end test results indicate no significant effect of the fin unporting on the fin loads.

Lamb, M.↗

The effect of transverse shear in a cracked plate under skew-symmetric loading

The problem of an elastic plate containing a through crack and subjected to twisting moments or transverse shear loads is considered. By using a bending theory which allows the satisfaction of the boundary conditions on the crack surface regarding the normal and the twisting moments and the transverse shear load separately, it is found that the resulting asymptotic stress field around the crack tip becomes identical to that given by the elasticity solutions of the plane strain and antiplane shear problems. The problem is solved for uniformly distributed or concentrated twisting moment or transverse shear load and the normalized Mode II and Mode III stress-intensity factors are tabulated. The results also include the effect of the Poisson's ratio and material orthotropy for specially orthotropic materials on the stress-intensity factors.

Delale, F.↗

Ultimate strength of high-load-capacity composite bolted joints

Presented are the results of a series of tests initiated to obtain baseline data on the load-carrying capacity of bolted joints designed to carry large loads, specifically up to 222 kN (50 kips). The major testing purposes were to determine the load carrying capacity as a function of the width and thickness of the joint and the diameter and number of bolts, and to observe the failure mode. A total of 100 tests were conducted on three different specimen configurations. The specimens were fabricated from a T300/5208 fiber/resin system in a quasi-isotropic lay-up. The results presented indicate that for a given ratio of specimen width to hole diameter, the specimens with the smaller holes sustained a higher net-section tensile stress before failure. In addition, for a given ratio of specimen width to hole diameter, the thinner specimens withstood a higher net-section stress. No attempt has been made to correlate the results with theoretical predictions.

Hyer, M. W.↗

Delamination crack growth in unidirectional fiber-reinforced composites under static and cyclic loading

An investigation of delamination crack growth in a unidirectional composite laminate under static and fatigue loading conditions is presented. An experimental program was conducted to study failure mechanisms and characterize the crack growth rate; analytical modeling based on microscopic observations was carried out using an advanced singular finite element method of the hybrid-stress model. Using a mixed-mode failure criterion, the delamination growth under a monotonically increasing load can be predicted; the rate of delamination crack propagation under fatigue loading is directly related to the amplitudes of cyclic opening and shearing mode stress intensity factors by a power law relationship.

Wang, S. S.↗

Fracture modes of high modulus graphite/epoxy angleplied laminates subjected to off-axis tensile loads

Angleplied laminates of high modulus graphite fiber/epoxy were examined in several ply configurations at various tensile loading angles to the zero ply direction to determine the effects of ply orientations on tensile properties, fracture modes, and fracture surface characteristics of the various plies. Experimental results consist of stress-strain data, selected plots, fracture stresses and strains, and scanning electron microscope (SEM) photographs of fracture surfaces. It was found that the stress-strain curves were linear to fracture, and that although fracture surface characteristics for a given fracture mode are similar to those for the same fracture mode in uniaxial specimens, no simple load angle range can be associated with a given fracture mode. It was also concluded that SEM results must be supplemented with ply stress calculations in order to identify ranges of fracture modes occurring as a function of ply orientation with respect to the load direction.

Sinclair, J. H.↗

Load transfer in composite bolted joints

The study deals with composite bolted joints, specifically those required to transmit primary loads. Consideration is given to the ultimate load capacity of quasi-isotropic bolted joint specimens as a function of the width of the joint, the diameter of the bolt, the joint thickness, and the number of bolts. Emphasis is placed on the effect of adding a second bolt, in tandem, on the load capacity of the joint.

Hyer, M. W.↗

Jet decay rate effects on hover jet-induced loads

The paper explains the mechanisms for observed jet decay rate effects on jet-induced loads on a flat plate for cross-flow and hover configurations. Examples are presented for the influence of the decay rate on integrated loads on a flat plate induced by the jet issuing at a right angle from the plate into still air; knowledge of these jet-induced loadings is of particular importance for VTOL aircraft design because they produce an effective loss in the lift force available in hover. The apparent inconsistency between existing lift loss vs jet decay rate trends is explained in light of the different mechanism which determine the jet mixing and trajectory, i.e., entrainment, blockage, and the vortex pair associated with a jet in crossflow.

Kuhlman, J. M.↗

A modified T-value method for selection of strain gages for measuring loads on a low aspect ratio wing

A technique which may be useful for selecting strain gages for use in load equations is described. The technique is an adaptation of the previously used T-value method and is applied to a multispar structure. The technique, called the modified T-value method, is used to reduce the number of strain gages used in a load equation from twelve to two. A parallel reduction is made by calculating relative equation accuracies from three applied load distributions. The equations developed from the modified T-value method proved to be accurate more consistently than the T-value method.

Tang, M. H.↗

Evaluation of integral exposure energy load on aural analyzer of miners

The individual exposure integral noise load on workers before the beginning of hearing impairment was determined for a group of 20 male miners who had worked with drilling equipment and harvesters for 8 to 20 years before the onset of the disability. Results show that the total exposure energy load of about 4 kw x h sq m, obtained by miners in the examined group, resulted in occupational injury to the auditory organ (cochlear neuritis) in 75% of the cases. The equivalent energy level of noise computed according to the date of total energy load is roughly 99 db A, which significantly exceeds the permissible amount of 85 db A. There is a correlation (r = 0.77) between the integral exposure energy noise on the aural analyzer in the degree of increase in the total threshold for the mean speech range.

Kornilov, A. N.↗

Wind loads on flat plate photovoltaic array fields

The results of an experimental analysis (boundary layer wind tunnel test) of the aerodynamic forces resulting from winds acting on flat plate photovoltaic arrays are presented. Local pressure coefficient distributions and normal force coefficients on the arrays are shown and compared to theoretical results. Parameters that were varied when determining the aerodynamic forces included tilt angle, array separation, ground clearance, protective wind barriers, and the effect of the wind velocity profile. Recommended design wind forces and pressures are presented, which envelop the test results for winds perpendicular to the array's longitudinal axis. This wind direction produces the maximum wind loads on the arrays except at the array edge where oblique winds produce larger edge pressure loads. The arrays located at the outer boundary of an array field have a protective influence on the interior arrays of the field. A significant decrease of the array wind loads were recorded in the wind tunnel test on array panels located behind a fence and/or interior to the array field compared to the arrays on the boundary and unprotected from the wind. The magnitude of this decrease was the same whether caused by a fence or upwind arrays.

Miller, R. D.↗

An approximate solution to improve computational efficiency of impedance-type payload load prediction

The computational efficiency of the impedance type loads prediction method was studied. Three goals were addressed: devise a method to make the impedance method operate more efficiently in the computer; assess the accuracy and convenience of the method for determining the effect of design changes; and investigate the use of the method to identify design changes for reduction of payload loads. The method is suitable for calculation of dynamic response in either the frequency or time domain. It is concluded that: the choice of an orthogonal coordinate system will allow the impedance method to operate more efficiently in the computer; the approximate mode impedance technique is adequate for determining the effect of design changes, and is applicable for both statically determinate and statically indeterminate payload attachments; and beneficial design changes to reduce payload loads can be identified by the combined application of impedance techniques and energy distribution review techniques.

White, C. W.↗

Effect of load eccentricity and substructure deformation on ultimate strength of shuttle orbiter thermal protection system

The effect of load eccentricity and substructure deformation on the ultimate strength and stress displacement properties of the shuttle orbiter thermal protection system (TPS) was determined. The LI-900 Reusable Surface Insulation (RSI) tiles mounted on the .41 cm thick Strain Isolator Pad (SIP) were investigated. Substructure deformations reduce the ultimate strength of the SIP/tile TPS and increase the scatter in the ultimate strength data. Substructure deformations that occur unsymmetric to the tile can cause the tile to rotate when subjected to a uniform applied load. Load eccentricity reduces SIP/tile TPS ultimate strength and causes tile rotation.

Sawyer, J. W.↗