Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Corrugated Membrane Fuel Cell Structures

One of the most challenging aspects of traditional PEM fuel cell stacks is the difficulty achieving the platinum catalyst utilization target of 0.2 gPt/kWe set forth by the DOE. Good catalyst utilization can be achieved with state-of-the-art catalyst coated membranes (CCM) when low catalyst loadings (<0.3 mg/cm 2 ) are used at a low current. However, when low platinum loadings are used, the peak power density is lower than conventional loadings, requiring a larger total active area and a larger bipolar plate. This results in a lower overall stack power density not meeting the DOE target. By corrugating the fuel cell membrane electrode structure, Ion Power’s goal is to realize both the Pt utilization targets as well as the power density targets of the DOE. This will be achieved by demonstrating a fuel cell single cell (50 cm 2 ) with a twofold increase in the membrane active area over the geometric area of the cell by corrugating the MEA structure. The corrugating structure must be able to demonstrate the target properties of < 10 mOhm-cm 2 electrical resistance at > 20 psi compressive strength over the active area, in combination with offering at least 80% of power density that can be achieved by using the same MEA in a flat plate structure. Corrugated membrane fuel cell structures also have the potential to meet DOE power density targets by essentially packaging more membrane area into the same fuel cell volume as compared to conventional stack constructions.

08 HYDROGEN↗

SiC MOSFET Based Modular Universal Power Electronics Regulator

A modular and scalable SiC MOSFET based universal power electronics regulator (UPER) allows coordinated integration of energy resources and loads, elimination of extra power conversion stages, and allowance of more sources or loads added with a simple plug and play feature. A comprehensive investigation has been conducted in term of the typical distributed generations and loads employed in buildings, in order to outline a detailed specification for UPER. Thus, a common DC bus voltage of 500 V and power rating of 3 kW are dedicatedly selected. The UPER hardware design and implementation are completely illustrated, including the static and dynamic characterization of the employed SiC MOSFET. The dedicated universal power cell and Plug-and-Play gate driver performs reliable continuous operation even exposed to an extreme fast switching speed (> 100 V/ns). The continuous operation of buck mode verified the UPER hardware development at 50 kHz with an overall efficiency of 98.19%. A new voltage polarity reversal phenomenon was also discovered in the verification of the isolated DAB stage with planar transformers.

Zheng, Sheng↗

Integrated Pulse Detonation Propulsion and Magnetohydrodynamic Power

The prospects for realizing an integrated pulse detonation propulsion and magnetohydrodynamic (MHD) power system are examined. First, energy requirements for direct detonation initiation of various fuel-oxygen and fuel-air mixtures are deduced from available experimental data and theoretical models. Second, the pumping power requirements for effective chamber scavenging are examined through the introduction of a scavenging ratio parameter and a scavenging efficiency parameter. A series of laboratory experiments were carried out to investigate the basic engineering performance characteristics of a pulse detonation-driven MHD electric power generator. In these experiments, stoichiometric oxy-acetylene mixtures seeded with a cesium hydroxide/methanol spray were detonated at atmospheric pressure in a 1-m-long tube having an i.d. of 2.54 cm. Experiments with a plasma diagnostic channel attached to the end of the tube confirmed the attainment of detonation conditions (p2/p1 approximately 34 and D approximately 2,400 m/sec) and enabled the direct measurement of current density and electrical conductivity (approximately = 6 S/m) behind the detonation wave front, In a second set of experiments, a 30-cm-long continuous electrode Faraday channel, having a height of 2.54 cm and a width of 2 cm, was attached to the end of the tube using an area transition duct. The Faraday channel was inserted in applied magnetic fields of 0.6 and 0.95 T, and the electrodes were connected to an active loading circuit to characterize power extraction dependence on load impedance while also simulating higher effective magnetic induction. The experiments indicated peak power extraction at a load impedance between 5 and 10 Omega. The measured power density was in reasonable agreement with a simple electrodynamic model incorporating a correction for near-electrode potential losses. The time-resolved thrust characteristics of the system were also measured, and it was found that the NM interaction exerted a negligible influence on system thrust and that the measured I(sub sp) of the system (200 see) exceeded that computed for an equivalent nozzleless rocket (120 see).

Litchford, Ron J.↗

A survey on wind power ramp forecasting.

The increasing use of wind power as a source of electricity poses new challenges with regard to both power production and load balance in the electricity grid. This new source of energy is volatile and highly variable. The only way to integrate such power into the grid is to develop reliable and accurate wind power forecasting systems. Electricity generated from wind power can be highly variable at several different timescales: sub-hourly, hourly, daily, and seasonally. Wind energy, like other electricity sources, must be scheduled. Although wind power forecasting methods are used, the ability to predict wind plant output remains relatively low for short-term operation. Because instantaneous electrical generation and consumption must remain in balance to maintain grid stability, wind power's variability can present substantial challenges when large amounts of wind power are incorporated into a grid system. A critical issue is ramp events, which are sudden and large changes (increases or decreases) in wind power. This report presents an overview of current ramp definitions and state-of-the-art approaches in ramp event forecasting.

17 WIND ENERGY↗

Active Dopant Optical Spectroscopy via Laser Ablation for High Resolution Spectral Measurements

The goal of this exploratory express LDRD is to demonstrate a reproducible laser activated doping diagnostic for eventual use on the Z machine by producing consistent spectral line emission with radiances above 10 5 W sr -1 nm -1 111 -2 from a variety of dopant materials. Here we show that while such radiances are achieved, the line emission is from regions with high electron densities, and close to the laser ablation surface. Therefore, it would be more ideal to improve current optical spectroscopy capabilities on Z to view radiances around 10 4 W sr -l nm -l m -2 . We also discuss the viability of a modular beam path that can be remotely aligned and used on the Z machine. This technique can be used to make spatially resolved measurements of electric and magnetic field strengths and electron densities within the Z power flow and load regions. The measurements can also be used to inform theory and simulation efforts needed to design the next generation of pulsed power capabilities. This was funded as an exploratory LDRD project, number: 214278

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydropower Black Start: A Guidebook for Retrofitting Grid Dependent Hydropower

Not all United States (US) hydropower plants were designed to provide black start, but they are increasingly needed to uphold resilience in the evolving electric grid. This guidance is designed to help understand the minimal retrofits required for grid dependent hydropower (GDH) plants behind the point of interconnection (POI). For distribution connected hydropower plants or those with dedicated cranking paths, such upgrades can be sufficient for the plant to provide black start. For others, more coordination with the transmission system operator will be needed. This guidebook answers a number of questions relevant to retrofitting hydropower plants with black start capabilities. For example, the guidebook answers: • How flexible do the wicket gate controls need to be? • Who needs to do hydro governor model validation, why, and how? • How robust and flexible do the excitation and AVR controls need to be? • What protection settings need to be adjusted? • What relay(s) will need to be bypassed or overridden and at what risk? • What is the electrical energy demand of the station load or auxiliary power systems? • What should the strategy to energize transformer(s) along cranking path to address inrush currents be? • How should the critical load restoration be sequenced? In addition to outlining the specifications that hydropower plants need to meet for each component to be able to perform black start, this guidebook provides a set of case studies for specific upgrades needed at actual plants. Between the case studies of plants that have already performed black start retrofits and the examples of how this guidebook can be applied to scope future retrofits, five key themes have been identified for retrofit needs. 1. Protection needs “black start” mode: hydropower plants that are not designed with black start capabilities will have protections that prevent them from interconnecting to a “dead bus.” These protections will need to be overridden in every retrofit case and a separate black start mode should be established so that operators can safely switch between black start and grid connected modes, minimizing the risk to the plant. 2. Wicket gates need modern controls: digital governors accelerate the parameter tuning process and gate position sensors improve controllability, so plants with mechanical governors should be upgraded. Furthermore, a black start and islanding mode should be established for controls to maximize plant performance. 3. Robust excitation support: the DC system or excitation generator needs to be reliable enough to form and sustain the rotor electromagnetic field. These systems are typically undersized in plants that were not designed for black start, so they will need to be upgraded. 4. Turbine-governor model validation and operator training: validation of a standard hydro governor model is needed to characterize the dynamic response (i.e., inertial and primary frequency response) of the GDH. This is required for control development and old hydropower plants often have outdated or incorrect models. Operator training is also typically required to ensure the hardware retrofits are utilized correctly during the black start process. 5. Transformer and cranking path energization: any upgradation and control adjustment in front of the POI will depend upon the existing interconnection. Coordination with the transmission or distribution operator may be required.

13 HYDRO ENERGY↗

Bioresearch Module Design Definition and Space Shuttle Vehicle Integration Study. Volume 1: Basic Report

Preliminary designs of the Bioexplorer spacecraft, developed in an earlier study program, are analyzed and updated to conform to a new specification which includes use of both the Scout and the space shuttle vehicle for launch. The updated spacecraft is referred to as bioresearch module. It is capable of supporting a variety of small biological experiments in near-earth and highly elliptical earth orbits. The baseline spacecraft design is compatible with the Scout launch vehicle. Inboard profile drawings, weight statements, interface drawings, and spacecraft parts and aerospace ground equipment lists are provided to document the design. The baseline design was analyzed to determine the design and cost impact of a set of optional features. These include reduced experiment power and thermal load, addition of an experiment television monitor, and replacement of VHF with S-band communications. The impact of these options on power required, weight change and cost is defined.

Lang, A. L., Jr.↗

Electrical power generation subsystem for Space Shuttle Orbiter

The requirements, capabilities, and design of the Space Shuttle Orbiter electrical power generation (EPG) subsystem are presented. The Orbiter EPG subsystem is designed to have the flexibility to supply the basic Orbiter electrical loads and the power requirements of the payloads which, in some cases, are completely dependent on the Orbiter for both power and heat rejection. These needs are supplied by three hydrogen/oxygen fuel cell powerplants (FCPs), having the capability of providing a total of 14 kW average and up to 24 kW peak in the basic Orbiter configuration. Kits permit dedication of one FCP to the payload by providing an additional reactant tank pair for a seven-day mission and additional heat rejection capability.

Blaski, M. F.↗

Integrated Pulse Detonation Propulsion and Magnetohydrodynamic Power

The prospects for realizing an integrated pulse detonation propulsion and magnetohydrodynamic (MHD) power system are examined. First, energy requirements for direct detonation initiation of various fuel-oxygen and fuel-air mixtures are deduced from available experimental data and theoretical models. Second, the pumping power requirements for effective chamber scavenging are examined through the introduction of a scavenging ratio parameter and a scavenging efficiency parameter. A series of laboratory experiments were carried out to investigate the basic engineering performance characteristics of a pulse detonation-driven MHD electric power generator. In these experiments, stoichiometric oxy-acetylene mixtures seeded with a cesium hydroxide/methanol spray were detonated at atmospheric pressure in a 1-m-long tube having an i.d. of 2.54 cm. Experiments with a plasma diagnostic channel attached to the end of the tube confirmed the attainment of detonation conditions (p(sub 2)/p(sub 1) approx. 34 and D approx. 2,400 m/sec) and enabled the direct measurement of current density and electrical conductivity (=6 S/m) behind the detonation wave front. In a second set of experiments, a 30-cm-long continuous electrode Faraday channel, having a height of 2.54 cm and a width of 2 cm, was attached to the end of the tube using an area transition duct. The Faraday channel was inserted in applied magnetic fields of 0.6 and 0.95 T. and the electrodes were connected to an active loading circuit to characterize power extraction dependence on load impedance while also simulating higher effective magnetic induction. The experiments indicated peak power extraction at a load impedance between 5 and 10 Ohm. The measured power density was in reasonable agreement with a simple electrodynamic model incorporating a correction for near-electrode potential losses. The time-resolved thrust characteristics of the system were also measured, and it was found that the MHD interaction exerted a negligible influence on system thrust and that the measured I(sub sp) of the system (200 sec) exceeded that computed for an equivalent nozzleless rocket (120 sec).

Litchford, R. J.↗

Deep Analysis Net with Causal Embedding for Coal-fired Power Plant Fault Detection and Diagnosis (DANCE4CFDD)

Fault detection and diagnosis is critical to power plant operation to ensure attaining high reliability while reducing operation cost. As more renewable power is introduced to the power grid, traditional fossil power plants take on the extra burden of excessive load cycling to compensate the generation variability from renewable power. Such load cycling will pose more reliability challenges to power plant operation. There are a number of challenges faced by today’s asset health management system in coal- fired (or gas) power plants: 1) high-dimensional nonlinear interaction among multiple time series measurements; 2) high measurement variance induced by operational conditions/modes; 3) variation among asset types and plant configurations; and 4) a small number of faulty events to learn from. To cope with these challenges, today’s fielded asset health management systems rely heavily on manual efforts from domain experts and hand-crafted features or rules based on domain knowledge. Despite its role in plant reliability, such a practice is costly and hinders its scalability and sustainability, particularly when a plant undergoes modifications. The objective of this project is to develop a novel end-to-end AI learning system that is trainable (i.e., the AI representation of a complex system behavior can be directly learned from properly labeled data) for accurate fault detection and root cause analysis. The ability to create a fault detection model directly from time series could alleviate the efforts associated with today’s asset management solution development. In the course of this project, we have achieved the following: Created an AI model development environment incorporating state-of-the-art neural network architectures for rapid model development and evaluation; Developed novel learning strategies for training of fault detection model; Developed special-purpose neural network architecture embedded with variable association graph aiming for better interpretability; Developed a learning strategy to leverage a small number of faulty events for enhanced fault detection capability; Conducted detailed experimental study based on public benchmark datasets and demonstrated the effectiveness of the proposed solution; and Validated the developed system with data from both a coal-fired plant boiler dynamic simulation model and real-world coal-fired power plant covering multiple asset and fault types. Overall, the project attained a technology readiness level of TRL 5 from TRL 2 at the beginning of the project.

20 FOSSIL-FUELED POWER PLANTS↗

21-Year Modeled Spatiotemporal Low-Level Jet Climatology Along the U.S. Mid-Atlantic Coast

Offshore wind farms are influenced by a variety of meteorological phenomena, ranging in spatial and temporal extent. One of these phenomena, the low-level jet (LLJ), is defined as a local maximum in wind speed with height in the planetary boundary layer, exhibiting a "nose-like" structure usually in the lowest few hundred meters above the surface. This vertical extent of LLJs may coincide with the rotor-swept area of a wind turbine, thus having implications for potential power production and mechanical loading. Previous studies in this area based on observations have confirmed the prevalence of LLJs here, with implications on power generation, wind turbine loads, and wake recovery depending on the LLJ characteristics, such as nose height and what part of the wind turbine power curve is being impacted.

LLJ↗

Distributionally Robust Building Load Control to Compensate Fluctuations in Solar Power Generation

This paper investigates the use of a collection of dispatchable heating, ventilation and air conditioning (HVAC) systems to absorb low-frequency fluctuations in renewable energy sources, especially in solar photo-voltaic (PV) generation. Given the uncertain and time-varying nature of solar PV generation, its probability distribution is difficult to be estimated perfectly, which poses a challenging problem of how to optimally schedule a fleet of HVAC loads to consume as much as local PV generation. We formulate a distributionally robust chance-constrained (DRCC) model to ensure that PV generation is consumed with a desired probability for a family of probability distributions, termed as an ambiguity set, built upon mean and covariance information. We benchmark the DRCC model with a deterministic optimization model and a stochastic programming model in a one-day simulation. We show that the DRCC model achieves constantly good performance to consume most PV generation even in the case with the presence of probability distribution ambiguity.

Zhang, Yiling↗

Thermal desalination via supercritical CO 2 Brayton cycle: Optimal system design and techno-economic analysis without reduction in cycle efficiency

The supercritical carbon dioxide (sCO 2 ) Brayton cycle is an upcoming power cycle potentially providing higher energy efficiency and more compact turbomachinery compared to traditionally used Brayton and Rankine cycles. The heat rejected from the sCO 2 Brayton cycle is quite hot (>70 degrees C) and must be cooled before flowing back to the compressor. However, this heat is ideal for producing fresh water with a thermal desalination system. This paper focuses on integrating multi-effect distillation (MED) with the sCO 2 stream exiting the recuperator. A new methodology for integration of MED with the sCO 2 Brayton cycle is proposed for simultaneous production of power and fresh water. The distillate produced does not affect the sCO 2 cycle efficiency, i.e., distillate is produced without being a parasitic load to the power plant compared to conventional integration of MED with steam Rankine cycle. To maximize the energy recovery from the waste heat stream exiting the sCO 2 cycle, a new methodology is formulated and discussed in the Appendix. Integration of MED with a 115 MW e sCO 2 power plant (49.2% efficient) produces 2813 m3/day of distillate and the cost of distilled water is 1.1 $/m 3 . Further, to enhance the distillate production, an innovative MED configuration is proposed, and for the same cycle operating condition with an electrical output 115 MW e , the net distillate production increases by 59% to 4472 m 3 /day at 1 $/m 3 . The cost of desalinated water for the integrated system is 17.8% lower than that of a standalone reverse-osmosis plant having the same capacity. Parametric analysis is performed to calculate the optimal design parameters for the integrated MED-sCO 2 system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Local control of reactive power by distributed photovoltaic generators

High penetration levels of distributed photovoltaic (PV) generation on an electrical distribution circuit may severely degrade power quality due to voltage sags and swells caused by rapidly varying PV generation during cloud transients coupled with the slow response of existing utility compensation and regulation equipment. Although not permitted under current standards for interconnection of distributed generation, fast-reacting, VAR-capable PV inverters may provide the necessary reactive power injection or consumption to maintain voltage regulation under difficult transient conditions. As side benefit, the control of reactive power injection at each PV inverter provides an opportunity and a new tool for distribution utilities to optimize the performance of distribution circuits, e.g. by minimizing thermal losses. We suggest a local control scheme that dispatches reactive power from each PV inverter based on local instantaneous measurements of the real and reactive components of the consumed power and the real power generated by the PVs. Using one adjustable parameter per circuit, we balance the requirements on power quality and desire to minimize thermal losses. Numerical analysis of two exemplary systems, with comparable total PV generation albeit a different spatial distribution, show how to adjust the optimization parameter depending on the goal. Overall, this local scheme shows excellent performance; it's capable of guaranteeing acceptable power quality and achieving significant saving in thermal losses in various situations even when the renewable generation in excess of the circuit own load, i.e. feeding power back to the higher-level system.

14 SOLAR ENERGY↗

Thermal Hydraulics Safety Analyses of TRIGA Reactor Upon Fuel Reconfiguration

Safety analyses of the Training, Research, Isotope, General Atomics (TRIGA) reactor at Kansas State University(KSU) is performed using thermal hydraulic simulations based on changes to reactivity or the volumetric heat generation rate due to changes in the positioning of the enriched fuel elements in the reactor core. If the reactivity or neutronics parameters are known, then they can be used to simulate the thermal energy state of the material which is crucial to assess the safety of the nuclear fuel inside a nuclear reactor. Several thermal hydraulics models and codes have been developed in the past to assess reactor safety. RELAP (Reactor Excursion and Leak Analysis Program) is one such tool widely used throughout the world for safety analyses. Although RELAP is considered a reliable tool by regulators, vendors, and operators, it lacks the numerical fidelity provided by 3-D computational fluid dynamics (CFD) models. This work involves the critical task of assessing safety of a research reactor upon fuel reconfiguration based on models developed in RELAP and comparing them with a commercially available 3-D CFD program. The TRIGA Mark-II reactor, designed by General Atomics and located at Kansas State University, is a class of small pool type inherently safe research reactor licensed to operate at steady state power of up to 1.25 MW. It has a cylindrical core measuring 0.45 meters diametrically and 0.38 meters axially positioned in a tank measuring 1.98 meters diametrically and 6.25 meters axially. It has uranium zirconium hydride (UZrH) fuel rods housed in stainless steel cladding material arranged in five concentric rings (B,C,D,E and F rings, in that order, moving outwards from the center). TRIGA fuel is nominally 20% enriched, but the reactivity of the fuel can be changed by using burnable poisons (not used at KSU), or by varying the total weight percent of uranium in the UZrH fuel meat. The TRIGA reactor is designed to be an inherently safe reactor and is designed to be cooled by natural convection. Thus it is of paramount importance to avoid the film boiling regime; failing to do so will subject the fuel to severe conditions, possibly resulting in its failure due to fuel/clad interactions. A high DNBR ratio is a primary consideration in the reactor core design and thus any modification in the core should ensure that this criteria is always met. In order to fully utilize the capabilities of KSU TRIGA reactor facility, it should be operated at its full capacity, i.e. 1.25 MW, which requires increasing the fuel loading in some of the E- and F-ring elements from 8.5% U (nominal) to 12.0% U (nominal). Only four elements are to be switched to 12% loading, causing local power peaking in these elements. The degree of power peaking to be expected in these 12%-loaded fuel elements was calculated based on a detailed MCNP (Monte Carlo N-Particle code) model of the reactor core. Some preliminary results of the calculations are presented in this paper based on changes in peaking factors and power levels. To predict reactor thermal behavior, axial changes in the peaking factors obtained from MCNP models were used to calculate volumetric energy density functions for a single channel one dimensional RELAP model and a three dimensional COMSOL model of the TRIGA MARK-II reactor. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Power Testing of A Fused Quartz-based Dielectric-Loaded Accelerating Structure

We report on the most recent results from a series of high power tests being carried out on rf-driven dielectric loaded accelerating (DLA) structures. The purpose of these tests is to determine the viability of the DLA as a traveling-wave accelerator and is a collaborative effort between Argonne National Laboratory (ANL), Naval Research Laboratory (NRL), and Stanford Linear Accelerator Center (SLAC). In this paper, we report on the recent high power tests of a fused quartz-based DLA structure that was carried out at incident powers of up to 12 MW at NRL and 37 MW at SLAC. We also report on test results of a TiN coated quartz structure, that exhibits good multipactor suppression.

36 MATERIALS SCIENCE↗

Reliability of emergency and standby diesel generators: Impact on energy resiliency solutions

Emergency diesel generators are the most common form of backup power for critical loads when the grid fails and are most often deployed as stand-alone generators (<2000 kW) tied to individual buildings for hospitals, emergency services, military bases, ports, airports, industries, and commercial facilities. Understanding the finite reliability of emergency diesel generators during continuous operation is critical for energy planners, managers, and end-users. A new analysis of two large non-public emergency diesel generator operational data sets shows that commonly used reliability metrics are inadequate to predict the performance during a grid outage. Additional metrics addressing the likelihood of an emergency diesel generator to be available at the time an outage starts, successfully start and carry load, and constantly run for the duration of the outage are needed to predict the continuous run-time reliability of emergency diesel generators during a grid outage. This is the first analysis of the reliability of modern generators that follow standard maintenance protocols commonly used for backup power and these new metrics are shown to be dependent on the level of emergency diesel generator maintenance with values that can vary by more than an order of magnitude. Even using the new metrics for well-maintained emergency diesel generators, the analysis shows that the single emergency diesel generators configurations are only 80% likely to provide power for the duration of a two-week grid outage.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗