At least 1,081 records · Page 60

Fission Surface Power Technology Demonstration Unit Test Results

The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7% resulting in a net system power of 8.1 kW and a system level efficiency of 17.2%. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to GRC. The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3%. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 %.

fission power technology↗

Zero Boil-Off Methods for Large Scale Liquid Hydrogen Tanks Using Integrated Refrigeration and Storage

NASA has completed a series of tests at the Kennedy Space Center to demonstrate the capability of using integrated refrigeration and storage (IRAS) to remove energy from a liquid hydrogen (LH2) tank and control the state of the propellant. A primary test objective was the keeping and storing of the liquid in a zero boil-off state, so that the total heat leak entering the tank is removed by a cryogenic refrigerator with an internal heat exchanger. The LH2 is therefore stored and kept with zero losses for an indefinite period of time. The LH2 tank is a horizontal cylindrical geometry with a vacuum-jacketed, multi-layer insulation system and a capacity of 125,000 liters. The closed-loop helium refrigeration system was a Linde LR1620 capable of 390W cooling at 20K (without any liquid nitrogen pre-cooling). Three different control methods were used to obtain zero boil-off: temperature control of the helium refrigerant, refrigerator control using the tank pressure sensor, and duty cycling (on/off) of the refrigerator as needed. Summarized are the IRAS design approach, zero boil-off control methods, and results of the series of zero boil-off tests.

ZBO↗

Ultralow noise performance of an 8.4-GHz maser-feedhorn system

A total system noise temperature of 6.6 K was demonstrated with an 8.4-GHz traveling wave maser and feedhorn operating in a cryogenic environment. Both the maser and feedhorn were inserted in the helium cryostat, with the maser operating in the 1.6-K liquid bath and the feedhorn cooled in the helium gas, with a temperature gradient along the horn ranging from the liquid bath temperature at its lower end to room temperature at its top. The ruby maser exhibited 43 dB of gain with a bandwidth of 76 MHz(-3 dB) centered at 8400 MHz. Discussions of the maser, cooled feedhorn, and cryostat designs are presented along with a discussion of the noise temperature measurements.

Johnson, D. L.↗

Integrated cooling (i-Cool) textile of heat conduction and sweat transportation for personal perspiration management

Perspiration evaporation plays an indispensable role in human body heat dissipation. However, conventional textiles tend to focus on sweat removal and pay little attention to the basic thermoregulation function of sweat, showing limited evaporation ability and cooling efficiency in moderate/profuse perspiration scenarios. Here, we propose an integrated cooling (i-Cool) textile with unique functional structure design for personal perspiration management. By integrating heat conductive pathways and water transport channels decently, i-Cool exhibits enhanced evaporation ability and high sweat evaporative cooling efficiency, not merely liquid sweat wicking function. In the steady-state evaporation test, compared to cotton, up to over 100% reduction in water mass gain ratio, and 3 times higher skin power density increment for every unit of sweat evaporation are demonstrated. Besides, i-Cool shows about 3 °C cooling effect with greatly reduced sweat consumption than cotton in the artificial sweating skin test. The practical application feasibility of i-Cool design principles is well validated based on commercial fabrics. Owing to its exceptional personal perspiration management performance, we expect the i-Cool concept can provide promising design guidelines for next-generation perspiration management textiles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Vaporization Would Cool Primary Battery

Temperature of discharging high-power-density primary battery maintained below specified level by evaporation of suitable liquid from jacket surrounding battery, according to proposal. Pressure-relief valve regulates pressure and boiling temperature of liquid. Less material needed in cooling by vaporization than in cooling by melting. Technique used to cool batteries in situations in which engineering constraints on volume, mass, and location prevent attachment of cooling fins, heat pipes, or like.

Bhandari, Pradeep↗

Surface Instability of Liquid Propellant under Vertical Oscillatory Forcing

Fluid motion in a fuel tank produced during thrust oscillations can circulate sub-cooled hydrogen near the liquid-vapor interface resulting in increased condensation and ullage pressure collapse. The first objective of this study is to validate the capabilities of a Computational Fluid Dynamics (CFD) tool, CFD-ACE+, in modeling the fundamental interface transition physics occurring at the propellant surface. The second objective is to use the tool to assess the effects of thrust oscillations on surface dynamics. Our technical approach is to first verify the CFD code against known theoretical solutions, and then validate against existing experiments for small scale tanks and a range of transition regimes. A 2D axisymmetric, multi-phase model of gases, liquids, and solids is used to verify that CFD-ACE+ is capable of modeling fluid-structure interaction and system resonance in a typical thrust oscillation environment. Then, the 3D mode is studied with an assumed oscillatory body force to simulate the thrust oscillating effect. The study showed that CFD modeling can capture all of the transition physics from solid body motion to standing surface wave and to droplet ejection from liquid-gas interface. Unlike the analytical solutions established during the 1960 s, CFD modeling is not limited to the small amplitude regime. It can extend solutions to the nonlinear regime to determine the amplitude of surface waves after the onset of instability. The present simulation also demonstrated consistent trends from numerical experiments through variation of physical properties from low viscous fluid to high viscous fluids, and through variation of geometry and input forcing functions. A comparison of surface wave patterns under various forcing frequencies and amplitudes showed good agreement with experimental observations. It is concluded that thrust oscillations can cause droplet formation at the interface, which results in increased surface area and enhanced heat transfer between the liquid and gas phases as the ejected droplets travel well into the warmer gas region.

Yang, H. Q.↗

Assessment of Gaseous Helium Cooling in a Superconducting Coil Test Rig

An experimental rig was designed and constructed at the NASA Glenn Research Center to measure the alternating current (AC) losses of round, multifilament, superconducting (SC), magnesium diboride (MgB2) wire in the temperature range from 20 to 30 K. The rig resembles a permanent magnet (PM) motor with the stator windings omitted. Experiment packs containing the superconductor samples will be placed in the annular space between the rotor and the stator back iron. The original plan was to measure the AC losses by calorimetry using nonboiling liquid hydrogen as the cooling fluid. The present plan is to use helium gas (GHe) under a few bar pressure instead. This report summarizes the calculations that indicate that reasonable results can be obtained, even though the mass density of the GHe will be only a fraction of that of liquid hydrogen. It is necessary to show that the heat transfer coefficient from SC wire to GHe can be high enough, that the temperature rise of the He between the experiment inlet and outlet can be small enough, and that sufficient He flow can be driven by a commercially available He fan. Both straight wire samples to validate loss models and coils to simulate motor stator coils can be tested in the rig. The lowest superconductor temperature that is feasible to reach in the rig is estimated. The temperature range available for samples will be wider with the gaseous He system than it would have been with liquid hydrogen.

supeconductors↗

A CONDUCTION-BASED HEAT PIPE MODEL FOR ANALYZING THE ENTIRE PROCESS OF LIQUID-METAL HEAT PIPE STARTUP

The Heat Pipe-cooled Microreactor (HPM) is one of the micro nuclear reactor designs under active study at the U.S. Idaho National Laboratory. Among the major concerns of HPM research is to understand the startup behavior of the heat pipe-cooled system associated with the startup of the liquid-metal heat pipes initialing from frozen state. The startup of liquid-metal heat pipes typically involves a number of nonlinear mass and heat transport processes including the phase change from solid to liquid and vapor. Hence, it is still a huge challenge to simulate the liquid-metal heat pipe startup using conventional CFD methods and software. The major difficulties of numerical CFD modeling come from the phase-change process, multiphase interaction, microporous wick flow, and compressible gas dynamics that occur during startup of the liquid-metal heat pipes. This paper proposes a simplified conduction-based method to provide practical insights into the entire startup process of the liquid-metal heat pipes while mitigating the challenges of addressing all the complex physics. We discuss the theoretical basis and modeling assumptions to analyze the liquid-metal heat pipe startup from frozen state based solely on heat-conduction equations. Then, the proposed model is implemented into the commercial CFD software to verify the model performance. The model prediction results are discussed via the comparison with the experimental data obtained from sodium heat-pipe startup experiments.

42 ENGINEERING↗

Compact Liquid Deaerator

Gases are removed from liquids by a new deaerator that takes up only 5 inches (12.7 cm) at top of a medium-sized storage tank. Deaerator has a multiple cascading header that exposes more fluid at lower pressures than typical commercial deaerators. Potential applications are in hydraulic systems for aircraft and heavy machinery, in cooling systems where deaerated liquid is needed to prevent cavitation of pump.

Yamauchi, S. T.↗

Testing Bearing Balls For Ignition In Liquid Oxygen

Inexpensive, safe apparatus built to test cooling by, ignition in, and nucleate boiling to film boiling of liquid oxygen flowing around ball bearings. Provides for heating of bearing specimens, direct observations, and measurements of temperatures and temperature distributions by thermocouples and infrared sensors. Used to evaluate suitability of various materials and surface treatments for ball bearings in high-pressure liquid-oxygen turbopumps. Ball rests in fixture while liquid oxygen flows around it. Flow reversed so observer or infrared sensor can view phenomena on trailing or leading side of ball.

Wagner, William R.↗

Porous Plug Phase Separator and Superfluid Film Flow Suppression System for the Soft X-Ray Spectrometer Onboard Hitomi

When using superfluid helium in low gravity environments, porous plug phase separators are commonly used to vent boiloff gas while confining the bulk liquid to the tank. Invariably, there is a flow of superfluid film from the perimeter of the porous plug down the vent line. For the Soft X-ray Spectrometer onboard ASTRO-H (Hitomi), its approximately 30-liter helium supply has a lifetime requirement of more than 3 years. A nominal vent rate is estimated as ~ 30 ug/s, equivalent to ~ 0.7 mW heat load. It is therefore critical to suppress any film flow whose evaporation would not provide direct cooling of the remaining liquid helium. That is, the porous plug vent system must be designed to both minimize film flow and to ensure maximum extraction of latent heat from the film. The design goal for Hitomi is to reduce the film flow losses to <2 ug/s, corresponding to a loss of cooling capacity of <40 uW. The design adopts the same general design as implemented for Astro-E and E2, using a vent system composed of a porous plug, combined with an orifice, a heat exchanger, and knife-edge devices. In this paper, design, on-ground testing results and in-orbit performance are described.

Porous↗

Boiling incipience and convective boiling of neon and nitrogen

Forced convection and subcooled boiling heat transfer data for liquid nitrogen and liquid neon were obtained in support of a design study for a 30 tesla cryomagnet cooled by forced convection of liquid neon. The cryogen data obtained over a range of system pressures, fluid flow rates, and applied heat fluxes were used to develop correlations for predicting boiling incipience and convective boiling heat transfer coefficients in uniformly heated flow channels. The accuracy of the correlating equations was then evaluated. A technique was also developed to calculate the position of boiling incipience in a uniformly heated flow channel. Comparisons made with the experimental data showed a prediction accuracy of + or - 15 percent.

Papell, S. S.↗

Boiling incipience and convective boiling of neon and nitrogen

Forced convection and subcooled boiling heat transfer data for liquid nitrogen and liquid neon were obtained in support of a design study for a 30 tesla cryomagnet cooled by forced convection of liquid neon. This design precludes nucleate boiling in the flow channels as they are too small to handle vapor flow. Consequently, it was necessary to determine boiling incipience under the operating conditions of the magnet system. The cryogen data obtained over a range of system pressures, fluid flow rates, and applied heat fluxes were used to develop correlations for predicting boiling incipience and convective boiling heat transfer coefficients in uniformly heated flow channels. The accuracy of the correlating equations was then evaluated. A technique was also developed to calculate the position of boiling incipience in a uniformly heated flow channel. Comparisons made with the experimental data showed a prediction accuracy of plus or minus 15 percent

Papell, S. S.↗

Pumped, Two-Phase Heat-Transfer Loop

Two-phase heat-transfer system delivers coolant to equipment as liquid and removes it as vapor. Alternatively, system heats equipment by delivering vapor and removing condensed liquid. Two-phase scheme effective for heat transfer over long distances. Heat-transfer plates remove heat from or supply heat to equipment. If temperature of plate is high, valve opens liquid-supply line to plate, and cooling results. If plate temperature is low, valve opens liquid-suction line to plate, and heating ensues.

Edelstein, F.↗

U-gas +Cool GTL™ - A New Integrated Process for Direct Biomass Conversion to Liquid Fuels

The U-Gas gasification technology, marketed by Sungas, is a proven fluid bed gasification technology for biomass conversion. U-Gas has been tested on a wide variety of biomass feeds including wood and waste streams. The U-Gas Technology has successfully converted wood for more than 20 years in a gasification plant in Skive Denmark at the 150t/d size. GTI has also recently developed the Cool GTL process for converting biogas to high quality gasoline, jet, and diesel fuels. The technoeconomics and LCA for the combination of the two technologies results an integrated optimized process, which will be discussed. The Cool GTL process is still in development and the development should be complete by 2023. Cool GTL converts high CO2 content feeds to synthesis gas with a 2-2.4/1 H2/CO ratio suitable for fuels synthesis. The process is based on a novel, highly stabile CO2/steam reforming catalyst. The 2.0-2.4/1 H2/CO synthesis gas ratio is always achieved, independently of feed CO2 content, by adjusting the amount of water added according to the amount of CO2 in the feed. The reformer catalyst has been tested for 500 hours and shows no measurable deactivation. The product from the reformer then goes directly to a low temperature slurry bed Fischer Tropsch reactor with an integrated finishing hydroisomerization reactor which makes hydrocarbon liquids from the synthesis gas. With this configuration no wax is produced. The technoeconomics and carbon intensity for the integration of UGas and the Cool GTL processes will be compared to other biomass conversion approaches. The use of electrolysis to boost H2 in the feed and increase liquid production will also be analyzed as a potential process improvement with sensitivities to the cost of electricity and the use of renewable electricity.

09 BIOMASS FUELS↗

Noncontact Flow Rate Using Laser Ultrasonics

Several types of advanced nuclear reactors are cooled with high-temperature liquid metal or molten salt flows. There is a critical need to measure flow velocity in flow channels for test purposes, and eventually in operational reactors. In conventional ultrasonic flow sensors, ultrasonic waves traveling in both the upstream and downstream directions are generated and detected by transducers that must contact the flow channels. A shift in the frequency or transit time between the two ultrasonic waves is measured to determine flow velocity. We describe here an initial effort to apply that sensing concept when the contact transducers are replaced by laser-based generation and detection instrumentation. This noncontact sensing avoids many practical problems associated with contact transducers when implemented on flow channels at high temperature. Laser-based flow monitoring can also be applied to hot-process piping in the geothermal energy, chemical-processing and petroleum-refining industries. Our effort has included theoretical simulation of noncontact laser-based flow monitoring, indicating capability of measuring flow velocities relevant to reactor cooling. It also included a room-temperature experimental demonstration using water as the flow liquid, and indicating capability of measuring flow velocity at a responsivity roughly consistent with simulation predictions. Plans were made for an experimental demonstration at Oregon State University using liquid metal at 110 degrees C.

02 PETROLEUM↗

Melt Crystallization of CsF from Alkali Fluorides

Fractional melt-crystallization is a technique used to separate components in a multicomponent liquid mixture through controlled cooling. In fiscal year (FY) 2023, this technique was successfully used to separate CsCl from LiCl-KCl. This demonstrated a potential route for concentrating electrorefiner fission product waste streams in pyrochemical fuel cycles, building on previous work that developed the melt-crystallization system for fission product removal from LiCl-based electrolytes used for oxide reduction. This work investigated whether a thermally controlled process of a solid-liquid separation process could effectively remove CsF from LiF-NaF-KF (FLiNaK)-CsF salt for MSR fuel cycle applications. The designed process aimed to recover purified LiF-NaF-KF salt as solid precipitates while concentrating CsF to a remaining salt heel. This concentrated CsF can then be immobilized during a salt waste stream treatment operation, minimizing waste volume.

36 MATERIALS SCIENCE↗

A turnkey gaseous helium-cooled superconducting CORC ® dc power cable with integrated current leads

Abstract High-temperature superconducting (HTS) direct current (dc) power cable systems, capable of delivering power exceeding 10 MW while being cooled with cryogenic helium gas, have been developed for applications on naval electric ships, electric aircraft and in data centers. Current injection from room temperature into the superconducting power cable causes by far the greatest heat load to the cryogenic system. Efficient current leads with integrated helium gas heat exchangers were developed to inject a current exceeding 1 kA from room temperature into a superconducting Conductor on Round Core (CORC ® ) power cable, without the need for liquid nitrogen pre-cooling. A 2 m long single-pole CORC ® power cable system that included current leads was cooled using a Stirling cryocooler with a closed-loop helium gas circulation system. The turnkey power cable system allowed cool down from room temperature to its operating temperature of 60 K–70 K within 5 h, after which continuous operation at 1.2 kA was demonstrated. The successful development and demonstration of a CORC ® power cable with current leads containing integrated helium gas heat exchangers enables widespread implementation of HTS MW-class, high current density superconducting dc power cables in many applications with constrained space that require a power dense solution.

Physics↗