Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “large-scale simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Status of Mars Retropropulsion Testing in the Langley Unitary Plan Wind Tunnel

Future Mars human landings will be enabled by a powered descent phase starting at supersonic conditions, something which has never been done before on a Mars mission. Significant aerosciences challenges exist due to jet interactions between the retrorocket engine plumes, freestream flow, and vehicle that will affect the aerodynamic behavior during powered descent. Historically, wind tunnel tests have been used to study the interactions with inert gas exhaust simulants in place of rocket engines. On the computational side, flowfield simulations have been completed at full-scale conditions, but the available ground and flight data are not appropriate for calibrating computational uncertainties for aerodynamic interference on proposed Mars descent vehicles, due to insufficient data, dissimilar vehicle geometries, and disparate operating conditions. A wind tunnel test has been designed to begin addressing powered descent aerodynamics risks for large-scale human Mars entry concepts and to identify gaps in computational predictive capabilities. The test will be conducted in the NASA Langley Unitary Plan Wind Tunnel and is designed with improvements in model design and data products over past tests. The test campaign will be run using sub-scale model geometries derived from NASA powered descent reference vehicles: a blunt low lift-to-drag vehicle and a more slender geometry that generates higher unpowered lift. Both models have been fabricated and are ready for testing. The blunt model is equipped with the flexibility to examine the effects of nozzle pointing direction, number, location, size, and area ratio. The main measurements are heatshield aerodynamic interference forces and moments with a custom flow-through balance, discrete and distributed heatshield pressure, and high-speed flowfield visualization. This paper covers the test objectives, facility, models and instrumentation, and planned test matrix.

Mars↗

Computational Modeling of Mars Retropropulsion Concepts in the Langley Unitary Plan Wind Tunnel

Future human Mars missions will require powered descent starting at supersonic conditions, something which has never been done before at Mars. Computational powered descent flowfield simulations have been completed at full-scale Mars conditions, but the available ground test data are not appropriate for calibrating computational uncertainties for aerodynamic interference on proposed Mars descent vehicles. A test will be conducted in the NASA Langley Unitary Plan Wind Tunnel to begin addressing powered descent aerodynamics risks for large-scale human Mars entry concepts and to identify gaps in computational predictive capabilities. This paper covers pre-test computational flowfield predictions of two different models derived from full-scale reference vehicles: a blunt low lift-to-drag vehicle and a more slender geometry. Calculations of the blunt model include variations in nozzle configuration: nozzle location, size, area ratio, and pointing direction. There exist some significant differences between solvers, but some general trends are observed from simulations of the blunt model. First, aerodynamic axial force from the heatshield decreases with increasing thrust due to expanding plume blockage. Second, nozzles that point along the model axis result in lower aerodynamic axial force compared to nozzles that have a radial thrust component. Finally, placing the nozzles further away from the model nose preserves more heatshield axial force with increasing thrust com- pared to nozzles that are closer to the nose. For the slender model, the axial force from the heatshield is similar to the non-blowing axial force regardless of thrust magnitude, due to the nozzle arrangement on the heatshield. Once the test is completed, direct comparisons between the computations and test data will be made to determine computational uncertainties in a wind tunnel environment, to identify gaps in predictive capabilities, and to inform planning for future ground and flight test programs for Mars powered descent vehicles.

Mars↗

Status of Mars Retropropulsion Testing in the Langley Unitary Plan Wind Tunnel

Future Mars human landings will be enabled by a powered descent phase starting at supersonic conditions, something which has never been done before on a Mars mission. Significant aerosciences challenges exist due to jet interactions between the retrorocket engine plumes, freestream flow, and vehicle that will affect the aerodynamic behavior during powered descent. Historically, wind tunnel tests have been used to study the interactions with inert gas exhaust simulants in place of rocket engines. On the computational side, flowfield simulations have been completed at full-scale conditions, but the available ground and flight data are not appropriate for calibrating computational uncertainties for aerodynamic interference on proposed Mars descent vehicles, due to insufficient data, dissimilar vehicle geometries, and disparate operating conditions. A wind tunnel test has been designed to begin addressing powered descent aerodynamics risks for large-scale human Mars entry concepts and to identify gaps in computational predictive capabilities. The test will be conducted in the NASA Langley Unitary Plan Wind Tunnel and is designed with improvements in model design and data products over past tests. The test campaign will be run using sub-scale model geometries derived from NASA powered descent reference vehicles: a blunt low lift-to-drag vehicle and a more slender geometry that generates higher unpowered lift. Both models have been fabricated and are ready for testing. The blunt model is equipped with the flexibility to examine the effects of nozzle pointing direction, number, location, size, and area ratio. The main measurements are heatshield aerodynamic interference forces and moments with a custom flow-through balance, discrete and distributed heatshield pressure, and high-speed flowfield visualization. This paper covers the test objectives, facility, models and instrumentation, and planned test matrix.

Supersonic Retropropulsion↗

Computational Modeling of Mars Retropropulsion Concepts in the Langley Unitary Plan Wind Tunnel

Future human Mars missions will require powered descent starting at supersonic conditions, something which has never been done before at Mars. Computational powered descent flowfield simulations have been completed at full-scale Mars conditions, but the available ground test data are not appropriate for calibrating computational uncertainties for aerodynamic interference on proposed Mars descent vehicles. A test will be conducted in the NASA Langley Unitary Plan Wind Tunnel to begin addressing powered descent aerodynamics risks for large-scale human Mars entry concepts and to identify gaps in computational predictive capabilities. This paper covers pre-test computational flowfield predictions of two different models derived from full-scale reference vehicles: a blunt low lift-to-drag vehicle and a more slender geometry. Calculations of the blunt model include variations in nozzle configuration: nozzle location, size, area ratio, and pointing direction. There exist some significant differences between solvers, but some general trends are observed from simulations of the blunt model. First, aerodynamic axial force from the heatshield decreases with increasing thrust due to expanding plume blockage. Second, nozzles that point along the model axis result in lower aerodynamic axial force compared to nozzles that have a radial thrust component. Finally, placing the nozzles further away from the model nose preserves more heatshield axial force with increasing thrust compared to nozzles that are closer to the nose. For the slender model, the axial force from the heatshield is similar to the non-blowing axial force regardless of thrust magnitude, due to the nozzle arrangement on the heatshield. Once the test is completed, direct comparisons between the computations and test data will be made to determine computational uncertainties in a wind tunnel environment, to identify gaps in predictive capabilities, and to inform planning for future ground and flight test programs for Mars powered descent vehicles.

Supersonic Retropropulsion↗

Land Surface Modeling Over the Dry Chaco: The Impact of Model Structures, and Soil, Vegetation and Land Cover Parameters

In this study, we tested the impact of a revised set of soil, vegetation and land cover parameters on the performance of three different state-of-the-art land surface models (LSMs) within the NASA Land Information System (LIS). The impact of this revision was tested over the South American Dry Chaco, an ecoregion characterized by deforestation and forest degradation since the 1980s. Most large-scale LSMs may lack the ability to correctly represent the ongoing deforestation processes in this region, because most LSMs use climatological vegetation indices and static land cover information. The default LIS parameters were revised with improved soil parameters, satellite-based interannually varying vegetation indices (leaf area index and green vegetation fraction) instead of climatological vegetation indices, and yearly land cover information instead of static land cover. A relative comparison in terms of water budget components and “efficiency space” for various baseline and revised experiments showed that large regional and long-term differences in the simulated water budget partitioning relate to different LSM structures, whereas smaller local differences resulted from updated soil, vegetation and land cover parameters. Furthermore, the different LSM structures redistributed water differently in response to these parameter updates. A time-series comparison of the simulations to independent satellite-based estimates of evapotranspiration and brightness temperature (Tb) showed that no LSM setup significantly outperformed another for the entire region and that not all LSM simulations improved with updated parameter values. However, the revised soil parameters generally reduced the bias between simulated surface soil moisture and pixel-scale in situ observations and the bias between simulated Tb and regional Soil Moisture Ocean Salinity (SMOS) observations. Our results suggest that the different hydrological responses of various LSMs to vegetation changes may need further attention to gain benefits from vegetation data assimilation.

Michiel Maertens↗

Comparison of SAR and CYNSS surface water extent metrics over the Yucatan Lake wetland site

Wetlands have a major role in the carbon cycle, outgassing large quantities of carbon dioxide and methane through processes that are directly and strongly influenced by the duration and timing of inundation. Therefore, understanding the seasonal pattern of inundation can be a component for regional to global scale carbon models. Measurement of inundation extent also establishes a benchmark for the current status of wetland areas, useful in assessing the future impacts of climate change. The incorporation of frequent measurements of inundation extent into large-scale hydrological models would permit the evaluation of more detailed seasonal and longer-term floodplain dynamics and their associated management implications.The Cyclone GNSS (CYGNSS) constellation of satellites launched in 2016, and carries receivers capable of receiving data from L-band GNSS reflections. Delay Doppler maps (DDM) are generated on board and telemetered to the ground, along with a small number of raw data takes that can be used for special processing on the ground for evaluation purposes. It has been previously shown that these data can be sensitive to inundation.The NASA ISRO Synthetic Aperture Radar, currently planned for launch in January 2023, has both an L-band and S-band SAR for earth imaging. The L-band SAR, which will image the Earth's land mass twice every 12 days, has a requirement for measuring wetland inundation extent at the 1 ha scale. One of the sites that will be used to validate this requirement is Yucatan Lake, Louisiana. This oxbow lake and surrounding area located adjacent to the Mississippi river experiences periodic and extensive flooding in the surrounding forest areas.In 2019, NASA's UAVSAR fully polarimetric airborne L-band SAR conducted a flight campaign to image a dozen sites in the SE USA at approximately 12-day intervals and both in the morning and evening, to simulate the type of data NISAR will obtain. One site imaged during this campaign was the Yucatan Lake area, spanning water stages from low to high flood conditions.It has been demonstrated previously that GNSS reflectometry such as that measured by CYGNSS may be used to characterize surface inundation. It has also been known for decades that L-band SAR may be used to characterize not only the presence of open water, but also the presence of subcanopy inundation in forested areas. In this paper we will present results comparing data from these two types of instruments.

Lavalle, Marco↗

Unique NISTAR-Based Climate GCM Diagnostics of the Earth’s Planetary Albedo and Spectral Absorption Through Longitudinal Data Slicing

Deep Space Climate Observatory (DSCOVR) measurements of Earth’s reflected solar and emitted thermal radiation permit a unique model/data comparison perspective that is not readily available from other satellite data. The key factor is the unique Lissajous orbital viewing geometry from the Lagrangian L1 point, which enables a continuous view of Earth’s sunlit hemisphere. The National Institute of Standards and Technology Advanced Radiometer (NISTAR) is the DSCOVR Mission energy budget instrument, which views the reflected and emitted radiation of the Earth’s sunlit hemisphere by means of single pixel active cavity full-spectrum (Band-A, 0.2–100 μm) and filtered solar wavelength (Band-B, 0.2–4.0 μm; and Band-C, 0.7–4.0 μm) radiometer measurements. An additional solar wavelength photodiode channel (0.3–1.1 μm) provides a calibration reference. The objective of this study is the assessment of climate GCM performance via direct model/data comparisons. Such comparisons are difficult due to quasi-chaotic natural variability present in real-world observational data and in climate GCM simulations. This is where the unique DSCOVR viewing geometry makes possible the longitudinal data slicing methodology for more direct model/data comparison. The key point of the longitudinal slicing approach is that data integration over the entire sunlit hemisphere eliminates the quasi-chaotic meteorological weather-scale noise, while preserving intra-seasonal and planetary-scale variability. The rotation of the Earth that retrieves this climate-style, large-scale longitudinal and seasonal variability. The hemispheric averaging is accomplished automatically in NISTAR measurements with its single-pixel view of the Earth. For climate GCMs, this requires implementing the Sunlit Hemisphere Sampling (SHS) scheme to operate on the GCM run-time output data, utilizing the DSCOVR Satellite Ephemeris data to assure precise viewing geometry between NISTAR measurements and GCM output data, while averaging out the meteorological weather noise. However, GCM generated data are radiative fluxes, while NISTAR (and EPIC) measurements are near-backscattered radiances. Conversing NISTSR measurements into radiative fluxes cannot be accomplished using NISTAR data alone, even with detailed support from conventional satellite data. But the identical viewing geometry of Earth’s sunlit hemisphere, and synergistic analyses of EPIC data make it feasible for this conversion of NISTAR near-backscatter radiances into radiative fluxes.

deep space climate observatory↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

Cameron J. Hines↗

The TRAPPIST-1 Habitable Atmosphere Intercomparison (THAI). I. Dry Cases—The Fellowship of the GCMs

With the commissioning of powerful, new-generation telescopes such as the James Webb Space Telescope (JWST) and the ground-based Extremely Large Telescopes, the first characterization of a high molecular weight atmosphere around a temperate rocky exoplanet is imminent. Atmospheric simulations and synthetic observables of target exoplanets are essential to prepare and interpret these observations. Here we report the results of the first part of the TRAPPIST-1 Habitable Atmosphere Intercomparison (THAI) project, which compares 3D numerical simulations performed with four state-of-the-art global climate models (ExoCAM, LMD-Generic, ROCKE-3D, Unified Model) for the potentially habitable target TRAPPIST-1e. In this first part, we present the results of dry atmospheric simulations. These simulations serve as a benchmark to test how radiative transfer, subgrid-scale mixing (dry turbulence and convection), and large-scale dynamics impact the climate of TRAPPIST-1e and consequently the transit spectroscopy signature as seen by JWST. To first order, the four models give results in good agreement. The intermodel spread in the global mean surface temperature amounts to 7 K (6 K) for the N2-dominated (CO2-dominated) atmosphere. The radiative fluxes are also remarkably similar (intermodel variations less than 5%), from the surface (1 bar) up to atmospheric pressures ∼5 mbar. Moderate differences between the models appear in the atmospheric circulation pattern (winds) and the (stratospheric) thermal structure. These differences arise between the models from (1) large-scale dynamics, because TRAPPIST-1e lies at the tipping point between two different circulation regimes (fast and Rhines rotators) in which the models can be alternatively trapped, and (2) parameterizations used in the upper atmosphere such as numerical damping.

Martin Turbet↗

REACTER: A Versatile Tool for Large-Scale Reactive Molecular Dynamics

Accurately describing reactive events over long length and time scales remains a grand challenge of computational materials science. REACTER is a general protocol for modeling chemical reactions using classical force fields, and is implemented in the popular molecular dynamics software LAMMPS. REACTER has a growing user base and has been used as a model-building tool for a variety of materials, including thermoplastics, thermosets, glassy materials and composites. The method has also been applied to accelerated modeling of reversible chemical reactions, such as the formation of electrochemical components for batteries. Recently, the REACTER protocol has received some major upgrades to enhance its ability to predict when reactions occur and to make it easier to use. Force field parameters can now be automatically assigned to newly created bonds, angles and other interactions. Advanced reaction constraints have also been added, including an Arrhenius constraint to enforce an effective activation energy, a root-mean-square-deviation option for complex geometrical constraints, and a constraint based on the total potential energy of the atoms involved in a reactive site. This potential energy constraint allows for the accurate reproduction of DFT-based tight-binding (DFTB3) predicted bond dissociation curves for mechanically induced bond breaking.

polymer simulations, molecular dynamics↗

Atmospheric Energy Spectra in Global Kilometre-Scale Models

Eleven 40-day long integrations of five different global models with horizontal resolutions of less than 9 km are compared in terms of their global energy spectra. The method of normal-mode function decomposition is used to distinguish between balanced (Rossby wave; RW) and unbalanced (inertia-gravity wave; IGW) circulation. The simulations produce the expected canonical shape of the spectra, but their spectral slopes at mesoscales, and the zonal scale at which RW and IGW spectra intersect differ significantly. The partitioning of total wave energies into RWs an IGWs is most sensitive to the turbulence closure scheme and this partitioning is what determines the spectral crossing scale in the simulations, which differs by a factor of up to two. It implies that care must be taken when using simple spatial filtering to compare gravity wave phenomena in storm-resolving simulations, even when the model horizontal resolutions are similar. In contrast to the energy partitioning between the RWs and IGWs, changes in turbulence closure schemes do not seem to strongly affect spectral slopes, which only exhibit major differences at mesoscales. Despite their minor contribution to the global (horizontal kinetic plus potential available) energy, small scales are important for driving the global mean circulation. Our results support the conclusions of previous studies that the strength of convection is a relevant factor for explaining discrepancies in the energies at small scales. The models studied here produce the major large-scale features of tropical precipitation patterns. However, particularly at large horizontal wavenumbers, the spectra of upper tropospheric vertical velocity, which is a good indicator for the strength of deep convection, differ by factors of three or more in energy. High vertical kinetic energies at small scales are mostly found in those models that do not use any convective parameterisation.

DYAMOND↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boil Off Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Modeling and Simulation of Tank Pressure Control using Zero-Boiloff Active Thermal Control for LOXSAT Technology Demonstration Mission

To-date, research and modeling of cryogenic fluid management technologies (CFM) for spaceflight has been limited to ground tests, short-duration zero-g simulations (e.g. drop towers), and small-scale experiments on-orbit. There has not been a large-scale flight demonstration of a flight-like system. As future NASA missions to take humans further from Earth will require large, in-space cryogenic propulsion vehicles, it is imperative to begin collecting flight data for these systems to accurately model and design future vehicles. To meet this goal, NASA awarded tipping point technology demonstration awards to Eta Space, Lockheed Martin, Space Exploration Technologies (SpaceX), and United Launch Alliance (ULA) to demonstrate on-orbit storage and transfer of cryogenic propellant. For its award, Eta Space is developing LOXSAT-1. It is a small satellite that will be launched on a Rocket Lab Electron rocket. The spacecraft consists of a Rocket Lab Photon spacecraft bus with a primary payload of a spherical liquid oxygen (LOX) storage tank with thermodynamic control systems. The primary objective of the mission is to demonstrate zero-boil-off storage of liquid oxygen. To accomplish this objective, the payload is equipped with an active thermal control system fluid loop that consists of propellant management device (PMD), positive-displacement pump, heat exchanger connected to a cryocooler, and a spray bar mixing injector. When the fluid loop is operating, fluid is drawn from the tank by the PMD and pumped through the heat exchanger, lowering the fluid temperature below the fluid temperature in the tank. This subcooled liquid is then injected back into the tank through the spray bar. The subcooled injected liquid has two effects. If it is sprayed into the ullage space, the injected liquid will form into jets or droplets and exchange heat with the ullage gas. This will cool and condense the gas, reducing the pressure in the tank. Additionally, the liquid that is not sprayed through the ullage, as well as any remaining liquid spray from the ullage, will rejoin the liquid mass of the tank, lowering the bulk temperature of the liquid. These combines effects provide for zero-boil off pressure control by lowering the tank pressure and the liquid saturation pressure simultaneously, ensuring the liquid stays subcooled. To model these complex mechanics and predict the performance of the active thermal control system, NASA is providing Eta Space with 3 parallel models of the tank. The approach of providing 3 different models allows for cross-checking and comparisons between the three to better understand how different modeling assumptions and selection semi-empirical factors affects the modeling result. Additionally, developing 3 models provides three different schemes for numerical simulation, providing confidence that results depict real physical phenomenon and not numerical quirks of the program. Within the tank thermodynamics, there are two primary areas of heat transfer we concern ourselves with: the heat transfer between the ullage space and the droplet spray, and between the ullage space and bulk liquid. For the droplet heat transfer, there are multiple sets of assumptions that can be made and correlations that can be used. Currently, two working models - the TankSIM model and Easy5 model – provide for an overview of the different approaches available. The TankSIM model and Easy5 model use two different models for droplet heating and evaporation that illustrate how the models use different types of mechanisms to arrive at the same answer. For the TankSIM model, droplets are treated as spheres of constant radius. Heat is transferred from the ullage to the droplet and warms the droplet until it reaches saturation, then the droplet begins evaporating and reducing its radius and mass. To calculate the heat transfer coefficient between the droplet and ullage, the Ranz-Marshall correlation is used. To determine the number of droplets in the ullage, a resident mass approach is used. This approach averages the number of droplets such that residuals at the start-up and shut-off of the spray bar cancel out. This same approach is used in the Easy5 model. The GFSSP model implements a linked list to track individual droplet “nodes” within the model. For the Easy5 model, the droplet is assumed to have an interface at a temperature equal to the saturation temperature corresponding to the pressure of the gas phase. The heat transfer from the gas to the interface and the interface to the droplet bulk is then calculated, and the net mass transfer between the droplet and interface is determined by performing an energy balance across the interface. For the gas side of the interface, the Ranz-Marshall correlation is used. For the liquid side of the interface, a variety of correlations were tried, including Kronig and Brink (1950) and effective conductivity models. As a result of these assumptions, the Easy5 model currently predicts faster depressurization, as at saturated vapor conditions, the heat transfer coeffect on the liquid side for the Easy5 model is greater than the heat transfer coefficient predicted by Ranz-Marshall used in the TankSIM code. This greater heat flux translates into faster condensation of the saturated ullage gas. At the bulk liquid to ullage interface, the models are in much closer agreement. Both models model the ullage as a sphere centered within the bulk liquid in the tank, and both use the energy-jumping boundary condition to model heat and mass transfer across the interface. There are slight differences in how the interface temperature is calculated, however. The Easy5 model assumes the temperature of the interface is equal to the saturation temperature associated with the pressure of the gas phase. The TankSIM model calculates this temperature with Alabovskii’s equation, which provides a correction factor for interface temperatures. Analysis tasks are focused on determining rates of depressurization within the tank during active cooling operation. To maintain net positive suction head at the pump inlet, the tank pressure cannot fall faster than the saturation pressure associated with the temperature of the bulk liquid. Additionally, there is interest in analyzing the performance of the loop at different pump speeds and cryocooler input powers. Adjusting the flowrate affects both the performance of the heat exchanger between the cryocooler and pumped liquid, and the heat transfer between the droplet spray and the ullage. Ideally, a pump speed and cryocooler power can be selected that will allow the tank to operate in zero-boil-off mode with a very narrow range of storage pressure.

zero boil-off↗

Numerical Study on the Aerodynamics of an Iced Airfoil With Scale-Resolving Simulations

Scale-resolving simulations of the NACA 23012 airfoil with horn ice accretion on the leading edge are conducted using the hybrid Reynolds-averaged Navier–Stokes/large-eddy simulation (hybrid RANS/LES) and wall-modeled large-eddy simulation (WMLES) approaches implemented in the Launch, Ascent, and Vehicle Aerodynamics (LAVA) framework. Aerodynamic results at the Reynolds number of 1.8 million show good comparison with the experimental measurements at different angles of attack from pre-stall to post-stall regimes. The pressure plateaus caused by the flow separation and the recovery of pressure inside the separation bubble around the iced leading edge are well predicted with the scale-resolving simulations when sufficient grid resolution is used around the accreted ice. The unsteadiness of the turbulent flows around the iced airfoil is also examined through the turbulent kinetic energy with the Reynolds normal stress anisotropy. Kelvin–Helmholtz instability (KHI) arises at the shear layer triggered by the upper ice horn and leads to rapid laminar-to-turbulent transition over a large range of angle of attack. With the increase of the angle of attack, the region with high turbulence intensity induced by the unstable shear layer spreads quickly over the entire upper surface of the airfoil. The coherent KHI modes from the upper and lower ice horns are extracted using the spectral proper orthogonal decomposition (SPOD) technique. The SPOD modes extracted from the upper shear layer have large-scale variations in the spanwise direction and low-rank behavior where the energy of the leading SPOD mode at each Strouhal number of the KHI largely represents the total energy when the mode number in the spanwise direction is small.

ARMD↗

Numerical Study on the Aerodynamics of an Iced Airfoil With Scale-Resolving Simulations

Scale-resolving simulations of the NACA 23012 airfoil with horn ice accretion on the leading edge are conducted using the hybrid Reynolds-averaged Navier–Stokes/large-eddy simulation (hybrid RANS/LES) and wall-modeled large-eddy simulation (WMLES) approaches implemented in the Launch, Ascent, and Vehicle Aerodynamics (LAVA) framework. Aerodynamic results at the Reynolds number of 1.8 million show good comparison with the experimental measurements at different angles of attack from pre-stall to post-stall regimes. The pressure plateaus caused by the flow separation and the recovery of pressure inside the separation bubble around the iced leading edge are well predicted with the scale-resolving simulations when sufficient grid resolution is used around the accreted ice. The unsteadiness of the turbulent flows around the iced airfoil is also examined through the turbulent kinetic energy with the Reynolds normal stress anisotropy. Kelvin–Helmholtz instability (KHI) arises at the shear layer triggered by the upper ice horn and leads to rapid laminar-to-turbulent transition over a large range of angle of attack. With the increase of the angle of attack, the region with high turbulence intensity induced by the unstable shear layer spreads quickly over the entire upper surface of the airfoil. The coherent KHI modes from the upper and lower ice horns are extracted using the spectral proper orthogonal decomposition (SPOD) technique. The SPOD modes extracted from the upper shear layer have large-scale variations in the spanwise direction and low-rank behavior where the energy of the leading SPOD mode at each Strouhal number of the KHI largely represents the total energy when the mode number in the spanwise direction is small.

ARMD↗

Testing Cosmic Microwave Background Anomalies in E-mode Polarization with Current and Future Data

In this paper, we explore the power of the cosmic microwave background (CMB) polarization (E-mode) data to corroborate four potential anomalies in CMB temperature data: the lack of large angular-scale correlations, the alignment of the quadrupole and octupole (Q–O), the point-parity asymmetry, and the hemispherical power asymmetry. We use CMB simulations with noise representative of three experiments—the Planck satellite, the Cosmology Large Angular Scale Surveyor (CLASS), and the LiteBIRD satellite—to test how current and future data constrain the anomalies. We find the correlation coefficients ρ between temperature and E-mode estimators to be less than 0.1, except for the point-parity asymmetry (ρ = 0.17 for cosmic-variance-limited simulations), confirming that E-modes provide a check on the anomalies that is largely independent of temperature data. Compared to Planck component-separated CMB data (smica), the putative LiteBIRD survey would reduce errors on E-mode anomaly estimators by factors of ∼3 for hemispherical power asymmetry and point-parity asymmetry, and by ∼26 for lack of large-scale correlation. The improvement in Q–O alignment is not obvious due to large cosmic variance, but we found the ability to pin down the estimator value will be improved by a factor ≳100. Improvements with CLASS are intermediate to these.

Cosmic microwave background radiation↗

On the Settling Depth of Meltwater Escaping From Beneath Antarctic Ice Shelves

Antarctic glacial meltwater is thought to play an important role in determining large-scale Southern Ocean climate trends, yet recent modeling efforts have proceeded without a good understanding of how its vertical distribution in the water column is set. To rectify this, here we conduct new large-eddy simulations of the ascent of a buoyant meltwater plume after its escape from beneath an Antarctic ice shelf. We find that the meltwater’s settling depth is primarily a function of the buoyancy forcing per unit width of the source and the ambient stratification, consistent with the classical theory of turbulent buoyant plumes and in contrast to previous work that suggested an important role for centrifugal instability. Our results further highlight the significant role played by localized variability in stratification; this helps explain observed interannual variability in the vertical meltwater distribution near Pine Island Glacier. Because of the vast heterogeneity in mass loss rates and ambient conditions at different Antarctic ice shelves, a dynamic parameterization of meltwater settling depth may be crucial for accurately simulating high-latitude climate in a warming world; we discuss how this may be developed following this work, and where the remaining challenges lie.

Antarctic glacial meltwater↗